<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="f203"/> 
  <identifier> 
    <system value="https://intranet.aumc.nl/labvalues"/> 
    <!--   Does not exist   -->
    <value value="1304-03720-Bicarbonate"/> 
  </identifier> 
  <!--   Bicarbonate was measured on April fourth   -->
  <status value="final"/> 
  <code> 
    <!--   Kind of observation = Bicarbonate LOINC and SNOMED CT translations here - Note
     in the US the primary code will be LOINC per meaningful use.  Further SNOMED CT
      has acceeded to LOINC being the primary coding system for vitals and anthropromorphic
     measures.  SNOMED CT is required in some countries such as the UK.  -->
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="1963-8"/> 
      <display value="Bicarbonate [Moles/volume] in Serum or Plasma"/> 
    </coding> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="365722008"/> 
      <display value="Bicarbonate level"/> 
    </coding> 
  </code> 
  <subject> 
    <reference value="Patient/f201"/> 
    <display value="Roel"/> 
  </subject> 
  <issued value="2013-04-04T14:34:00+01:00"/> 
  <performer> 
    <reference value="Practitioner/f202"/> 
    <display value="Luigi Maas"/> 
  </performer> 
  <valueQuantity> 
    <!--   Bicarbonate=28mmol/L   -->
    <value value="28"/> 
    <unit value="mmol/L"/> 
    <system value="http://snomed.info/sct"/> 
    <code value="258813002"/> 
  </valueQuantity> 
  <interpretation> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="166698001"/> 
      <display value="Serum bicarbonate level normal"/> 
    </coding> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> 
      <code value="N"/> 
    </coding> 
  </interpretation> 
  <!--   The observation is complete   -->
  <!--   No reliability concerns   -->
  <method> 
    <!--   Method was enzymatic method   -->
    <text value="enzymatic method"/> 
  </method> 
  <referenceRange> 
    <!--   Healthy bicarbonate level ranges from 22mmol/L to 29mmol/L   -->
    <low> 
      <value value="22"/> 
    </low> 
    <high> 
      <value value="29"/> 
    </high> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/referencerange-meaning"/> 
        <code value="normal"/> 
        <display value="Normal Range"/> 
      </coding> 
    </type> 
  </referenceRange> 
</Observation> 