Healthy Route Implementation Guide, published by Savannah Informatics. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/savannahghi/healthy-route-ig/ and changes regularly. See the Directory of published versions

Visit and measurement

The screening visit, and everything measured during it.

One visit, one encounter

The protocols describe a single cross-sectional contact. A participant attending a routine clinic is approached, consented, interviewed, has three blood pressure readings taken, gives a urine sample for dipstick, gives blood and urine for the laboratory, and has both eyes photographed. There is no follow-up visit and no admission.

HREncounter is the spine everything else hangs from. Observation, ServiceRequest, DiagnosticReport and ImagingStudy all require one, because a result that cannot be placed at a visit cannot be placed against the consent that was in force, or against the clinic the participant was recruited from.

The clinic matters. Both protocols recruit from general out-patient, hypertension, diabetes and renal clinics, and a cohort drawn mostly from a renal clinic has a different disease prevalence from one drawn mostly from general out-patients. Predictive values move with prevalence, so Encounter.location is where an analysis finds out which population it is actually looking at.

One profile for every measurement

HRObservation carries creatinine, eGFR, HbA1c, the urine albumin-to-creatinine ratio, the urine dipstick, height, weight, body mass index, and the additional investigations one country collects.

They differ in code, unit and value type. They do not differ in shape, and a profile for each analyte would mean a new StructureDefinition and a new release of this guide every time a laboratory adds a test. What distinguishes one measurement from another is Observation.code, which is what a consumer filters on.

The rule this follows: profile where the datatype alone does not constrain the value; do not where it does. A creatinine is a Quantity with a UCUM unit and the datatype has already done the work.

The one exception, and we did not write it

Blood pressure puts its two readings in component rather than in value[x]. FHIR core already profiles that as http://hl7.org/fhir/StructureDefinition/bp, with the components sliced, their LOINC codes fixed and their units fixed to mmHg. HRBloodPressure derives from it and adds only tenancy and the encounter requirement.

FHIR is single-inheritance, so the tenant extension is restated there rather than inherited from HRObservation. Three lines of duplication is a better trade than reimplementing a profile HL7 maintains.

Three readings and a derived value

This is where the two protocols visibly differ, and where the guide's architecture was tested.

One times three readings around the retinal photography — sixty minutes before, fifteen minutes either side, sixty minutes after — and averages them. The other takes a triplicate after five minutes of rest and uses the mean of the last two, discarding the first.

Those are different procedures, not different thresholds. They are nevertheless instance data, because of how the readings are modelled:

  • each reading is its own HRBloodPressure, with its own effectiveDateTime
  • the value carried to analysis is a fourth resource, whose derivedFrom names the readings it actually used

Three readings and their mean are four resources, not one resource with four values. What differs between countries is which readings derivedFrom points at, and that is data. The averaging rule itself belongs to the study, not to the resource — so the profile deliberately does not encode it, and a consumer can check the arithmetic instead of trusting it.

The dipstick scale is defined and bound to nothing

HRDipstickProteinVS lists Negative, Trace, +1, +2 and +3.

It is not bound to HRObservation.value[x], and that is deliberate. The scale is printed on the protocols' own data collection tool as fixed options, so values reach the record by transcription from a form. The constraint that matters is on the entry screen, not on a StructureDefinition. LOINC publishes an answer list for 5804-0, but it is not expandable on the public terminology server, so a binding would have meant inventing a local scale and requiring it of every site.

The value set exists so that whoever builds the form has a canonical list, and so a consumer knows what the values mean.

It matters more than its size suggests: in one protocol the dipstick gates eligibility, and in the other it is the comparator the algorithm's sensitivity and specificity are computed against.

eGFR is calculated, and says so

An eGFR is a number produced by an equation, and the equation is not recoverable from the number.

The example records derivedFrom naming the creatinine it was computed from, and method naming the equation. The LOINC code is 98979-8, the CKD-EPI 2021 revision with the race coefficient removed. 62238-1 is the generic CKD-EPI code and would understate what was done.

Where a laboratory reports eGFR directly rather than the platform deriving it, the same profile applies and derivedFrom is simply absent.

Orders and reports

HRServiceRequest records that an investigation was asked for, by whom and when. authoredOn is required: samples are drawn during a routine clinical visit where the participant's ordinary care is also happening, and a result with no request behind it cannot be told apart from one belonging to that other episode. intent is fixed to order — nothing here is a proposal awaiting authorisation.

HRDiagnosticReport gathers the results a laboratory issued together. The individual values are HRObservation resources and stand on their own; the report ties them to one issuing laboratory and one point in time. issued is kept distinct from effective[x], because the interval between a sample being drawn and a result being released is what a site is asked about once the participant has gone home.

Imaging: one series per eye

HRImagingStudy is metadata. It records which eye, when, and where the pixel data is held — it is not the images.

series.laterality is required, where the base resource leaves it optional. It is the only thing distinguishing two otherwise identical series, and a prediction attributed to the wrong eye is not detectable after the fact.

series is 1..* rather than 2..*. The protocols photograph both eyes, so a conforming study ordinarily carries two — but a capture can fail on the day, and a study recording a single usable eye is a truthful record where one asserting two would not be.

started is required because one protocol times its blood pressure readings relative to this moment. The interval is meaningless unless both carry a time.

What is not here

Specimen is referenced by Observation.specimen, ServiceRequest.specimen and DiagnosticReport.specimen, and is not yet profiled — those references point at the base resource. Device is likewise unprofiled, so the instrument on a blood pressure reading or a retinal camera can be referenced but not constrained.

Eligibility is absent deliberately. Encoding it needs a contradiction in one protocol resolved first: its screen-failure rule excludes a negative dipstick, while its recruitment target requires a control group most of whom will have one.