DK EER Endpoint Register (EER)
0.8.0 - ci-build Denmark flag

DK EER Endpoint Register (EER), published by . This guide is not an authorized publication; it is the continuous build for version 0.8.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/medcomdk/dk-ehmi-eer/ and changes regularly. See the Directory of published versions

Resource Profile: EER EndpointDevice - EUA

Official URL: http://medcomehmi.dk/ig/dk-ehmi-eer/StructureDefinition/EerDeviceEUA Version: 0.8.0
Draft as of 2024-12-12 Computable Name: EerDeviceEUA

An EerDeviceEUA profile of the EerDevice resource.

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* EerDevice Item used in healthcare
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... identifier S 1..1 Identifier Instance identifier
ele-1: All FHIR elements must have a @value or children
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.


ele-1: All FHIR elements must have a @value or children
... manufacturer S 1..1 string Name of device manufacturer
ele-1: All FHIR elements must have a @value or children
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
ele-1: All FHIR elements must have a @value or children
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... name 1..1 string The name of the device
ele-1: All FHIR elements must have a @value or children
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.


ele-1: All FHIR elements must have a @value or children
... owner S 0..1 Reference(Organization) Organization responsible for device
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* EerDevice Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier S 1..1 Identifier Instance identifier
... definition S 1..1 Reference(DeviceDefinition) The reference to the definition for the device
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier 0..1 string The distinct identification string
... manufacturer S 1..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... owner S 0..1 Reference(Organization) Organization responsible for device
... note 0..* Annotation Device notes and comments

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
Device.udiCarrier.entryTyperequiredUDIEntryType
http://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1
from the FHIR Standard
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.statusReasonextensibleFHIRDeviceStatusReason
http://hl7.org/fhir/ValueSet/device-status-reason
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from EerDevice

Summary

Differential View

This structure is derived from EerDevice

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* EerDevice Item used in healthcare
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... identifier S 1..1 Identifier Instance identifier
ele-1: All FHIR elements must have a @value or children
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.


ele-1: All FHIR elements must have a @value or children
... manufacturer S 1..1 string Name of device manufacturer
ele-1: All FHIR elements must have a @value or children
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
ele-1: All FHIR elements must have a @value or children
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... name 1..1 string The name of the device
ele-1: All FHIR elements must have a @value or children
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.


ele-1: All FHIR elements must have a @value or children
... owner S 0..1 Reference(Organization) Organization responsible for device
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* EerDevice Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier S 1..1 Identifier Instance identifier
... definition S 1..1 Reference(DeviceDefinition) The reference to the definition for the device
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier 0..1 string The distinct identification string
... manufacturer S 1..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... owner S 0..1 Reference(Organization) Organization responsible for device
... note 0..* Annotation Device notes and comments

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
Device.udiCarrier.entryTyperequiredUDIEntryType
http://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1
from the FHIR Standard
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.statusReasonextensibleFHIRDeviceStatusReason
http://hl7.org/fhir/ValueSet/device-status-reason
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from EerDevice

Summary

 

Other representations of profile: CSV, Excel, Schematron