DK EHMI Endpoint Register (EER)
1.0.0-draft - ci-build Denmark flag

DK EHMI Endpoint Register (EER), published by MedCom. This guide is not an authorized publication; it is the continuous build for version 1.0.0-draft built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/medcomdk/dk-ehmi-eer/ and changes regularly. See the Directory of published versions

Resource Profile: EER Device - AP

Official URL: http://medcomehmi.dk/ig/eer/StructureDefinition/EerDeviceAP Version: 1.0.0-draft
Draft as of 2025-10-15 Computable Name: EerDeviceAP

An EerDeviceAP profile of the EerDevice resource.

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* EerDevice Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier S 1..1 Identifier Instance identifier
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... manufacturer S 1..1 string Name of device manufacturer
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... owner S 0..1 Reference(Organization) Organization responsible for device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from EerDevice

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* EerDevice Item used in healthcare

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* EerDevice Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier S 1..1 Identifier Instance identifier
... definition S 1..1 Reference(DeviceDefinition) The reference to the definition for the device
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
... distinctIdentifier 0..1 string The distinct identification string
... manufacturer S 1..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... owner S 0..1 Reference(Organization) Organization responsible for device
... note 0..* Annotation Device notes and comments

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from EerDevice

Summary

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* EerDevice Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier S 1..1 Identifier Instance identifier
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... manufacturer S 1..1 string Name of device manufacturer
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... owner S 0..1 Reference(Organization) Organization responsible for device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

Differential View

This structure is derived from EerDevice

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* EerDevice Item used in healthcare

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* EerDevice Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier S 1..1 Identifier Instance identifier
... definition S 1..1 Reference(DeviceDefinition) The reference to the definition for the device
... status ?!SΣ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
... distinctIdentifier 0..1 string The distinct identification string
... manufacturer S 1..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... deviceName S 1..1 BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... owner S 0..1 Reference(Organization) Organization responsible for device
... note 0..* Annotation Device notes and comments

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from EerDevice

Summary

 

Other representations of profile: CSV, Excel, Schematron