Quality Checks |
Publisher Version: | IG Publisher Version: v1.8.1 |
Publication Code: | n/a . PackageId = hl7.fhir.dk.core, Canonical = http://hl7.dk/fhir/core |
Realm Check for n/a: | |
Publication Request: | Error parsing publication-request.json: Error parsing JSON source: Unexpected JSON syntax at Line 12 (path=[/_title]) from '/scratch/repo/publication-request.json' |
Supressed Messages: | 12 Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
hl7.fhir.dk.core | 3.5.0 | R4 | http://hl7.dk/fhir/core | | |
hl7.terminology.r4 | 6.1.0 M | R4 | http://terminology.hl7.org | http://terminology.hl7.org/6.1.0 | |
hl7.fhir.uv.extensions.r4 | 5.1.0 M | R4 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/5.1.0 | |
hl7.fhir.uv.phd | 1.0.0 O | R4 | http://hl7.org/fhir/uv/phd | http://hl7.org/fhir/uv/phd/STU1 | Latest Release is 1.1.0 |
hl7.terminology.r4 | 3.1.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/3.1.0 | Latest Release is 6.1.0 |
Templates: hl7.dk.fhir.template#0.0.1 -> fhir.base.template#current. Tools: 0.3.0 |
Dependent IGs: | 15 guides |
Global Profiles: | (none declared) |
Terminology Server(s): | http://tx.fhir.org/r4 (details) |
HTA Analysis: | 6 issues |
R5 Dependencies: | |
Draft Dependencies: |
-
hl7.fhir.r4.core#4.0.1: GuideParameterCode
(15 uses), observation-vitalsigns
(4 uses), observation-bp
(1 uses), observation-heartrate
(2 uses), CareTeamStatus
(1 uses), ConsentState
(1 uses), EpisodeOfCareStatus
(1 uses), RequestStatus
(1 uses), observation-bodyweight
(1 uses), Organization
(23 uses), CommonLanguages
(10 uses), CarePlan
(2 uses), DeviceRequest
(2 uses), ImmunizationRecommendation
(2 uses), MedicationRequest
(2 uses), NutritionOrder
(2 uses), ServiceRequest
(2 uses), MedicationAdministration
(2 uses), MedicationDispense
(2 uses), MedicationStatement
(2 uses), Procedure
(2 uses), Immunization
(2 uses), ImagingStudy
(4 uses), ObservationCategoryCodes
(2 uses), LOINCCodes
(4 uses), Group
(3 uses), Location
(3 uses), Device
(5 uses), Encounter
(3 uses), PractitionerRole
(9 uses), CareTeam
(3 uses), SNOMEDCTBodyStructures
(3 uses), ObservationMethods
(2 uses), Specimen
(2 uses), DeviceMetric
(2 uses), ObservationReferenceRangeMeaningCodes
(2 uses), ObservationReferenceRangeAppliesToCodes
(2 uses), QuestionnaireResponse
(4 uses), MolecularSequence
(4 uses), DocumentReference
(2 uses), Media
(2 uses), Condition
(6 uses), ConditionClinicalStatusCodes
(1 uses), ConditionVerificationStatus
(1 uses), ConditionCategoryCodes
(1 uses), Condition/DiagnosisSeverity
(1 uses), Condition/Problem/DiagnosisCodes
(3 uses), ConditionStage
(1 uses), ClinicalImpression
(1 uses), DiagnosticReport
(1 uses), ConditionStageType
(1 uses), ManifestationAndSymptomCodes
(1 uses), ContactEntityType
(1 uses), Endpoint
(1 uses), Practitioner
(3 uses), RelatedPerson
(1 uses)
-
hl7.fhir.uv.phd#1.0.0: PhdImplementationGuide
(1 uses), PhdPatient
(2 uses), PhgDevice
(2 uses), ContinuaDeviceIdentifiers
(8 uses), ContinuaPHD
(5 uses), ContinuaHFS
(2 uses), ASN1ToHL7
(12 uses), PhdDevice
(3 uses), PhdNumericObservation
(4 uses), PhdCoincidentTimeStampObservation
(2 uses), PhdCompoundNumericObservation
(1 uses), PhdBitsEnumerationObservation
(1 uses)
-
hl7.fhir.uv.tools.r4#0.3.0: ResourceSortExt
(108 uses)
|
Modifier Extensions: | (none) |
Previous Version Comparison: | Comparison with version 3.3.0 |
IPA Comparison: | Comparison with version 1.0.0 |
IPS Comparison: | n/a |
Validation Flags: | On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings |
Summary: | errors = 0, warn = 84, info = 32, broken links = 0 |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Device/BPMonitor.C4F312FFFE53F2C9. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/CoincidentTimeStamp.0222. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseBloodPressure. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseBodyTemperature. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseConsciousness. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseHeartRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseRespirationRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElseUrinStix. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ElsesTOBSscore. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/HeartRate.Poul.1974654. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/ObservationOxySatBasicObservationOrg. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxBloodPressure. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxBodyTemperature. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxConsciousness. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxGlasgowComaScale. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxHeartRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxRespirationRate. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxSaturation. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Observation/MaxVitalSignsPanel. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Patient/Poul. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
| warning | Unable to find ImplementationGuide.definition.resource.description for the resource Device/Telma.FEEDDADADEADBEEF. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list. |
Path | Severity | Message |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.identifier[0].type (l64/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[0].valueCode[0] (l155/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[0].valueCode[1] (l164/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[0].valueCode[2] (l173/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[1].valueCode[0] (l196/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS|1.0.0 |
Bundle.entry[1].resource/*Device/Telma.FEEDDADADEADBEEF*/.property[3].type (l233/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.identifier[0].type (l275/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.identifier[1].type (l288/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[0].valueCode[0] (l395/c16) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[2].type (l431/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[3].type (l453/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[2].resource/*Device/BPMonitor.C4F312FFFE53F2C9*/.property[4].type (l475/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.code.coding[2].system (l636/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.component[0].code.coding[2].system (l667/c14) | warning | A definition for CodeSystem 'http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes' could not be found, so the code cannot be validated (from http://tx.fhir.org/r4) |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.component[1].code.coding[2] (l695/c14) | warning | A definition for CodeSystem 'http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes' could not be found, so the code cannot be validated |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.code.coding[2] (l636/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[5].resource/*Observation/BloodPressure.Poul.643992*/.component[0].code.coding[2] (l667/c14) | warning | A definition for CodeSystem 'http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes' could not be found, so the code cannot be validated |
Bundle.entry[6].resource/*Observation/HeartRate.Poul.1974654*/.code.coding[2] (l794/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.1' could not be found, so the code cannot be validated |
Bundle.entry[7].resource/*Observation/BloodPressureStatus.Poul.133527*/.component[0].code (l890/c14) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Bundle.entry[1].resource/*Observation/MaxConsciousness*/ (l50/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[2].resource/*Observation/MaxBloodPressure*/.code.coding[1] (l120/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[2].resource/*Observation/MaxBloodPressure*/ (l102/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[3].resource/*Observation/MaxBodyTemperature*/.code.coding[1] (l210/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[3].resource/*Observation/MaxBodyTemperature*/ (l192/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[4].resource/*Observation/MaxHeartRate*/.code.coding[1] (l264/c10) | warning | A definition for CodeSystem 'urn:oid:1.2.208.176.2.4' could not be found, so the code cannot be validated |
Bundle.entry[4].resource/*Observation/MaxHeartRate*/ (l246/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[5].resource/*Observation/MaxRespirationRate*/ (l300/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/ (l354/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.value.ofType(Quantity) (l374/c10) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[0].high (l381/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[1].low (l391/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[1].high (l396/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[6].resource/*Observation/MaxGlasgowComaScale*/.referenceRange[2].low (l406/c14) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Bundle.entry[1].resource (l50/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[2].resource (l102/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[3].resource (l192/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[4].resource (l246/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[5].resource (l300/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Bundle.entry[6].resource (l354/c8) | warning | Best Practice Recommendation: In general, all observations should have a performer |
Path | Severity | Message |
Device.identifier[0].type (l12/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.identifier[1].type (l25/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.property[0].valueCode[0] (l132/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[2].type (l168/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[3].type (l190/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[4].type (l212/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Device.identifier[0].type (l12/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.property[0].valueCode[0] (l103/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[0].valueCode[1] (l112/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[0].valueCode[2] (l121/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[1].valueCode[0] (l144/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS|1.0.0 |
Device.property[3].type (l181/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Device.identifier[0].type (l12/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.identifier[1].type (l25/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers|1.0.0 |
Device.property[0].valueCode[0] (l132/c10) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD|1.0.0 |
Device.property[2].type (l168/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[3].type (l190/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Device.property[4].type (l212/c8) | information | Reference to experimental CodeSystem http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7|1.0.0 |
Path | Severity | Message |
Observation.value.ofType(Quantity) (l21/c4) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[0].high (l28/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[1].low (l38/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[1].high (l43/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation.referenceRange[2].low (l53/c8) | warning | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
Observation (l1/c2) | warning | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-ElsePainVRS.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-ElseUrinStix.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxBloodPressure.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxBodyTemperature.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxConsciousness.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxHeartRate.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxRespirationRate.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxSaturation.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Observation-MaxVitalSignsPanel.json | Best Practice Recommendation: In general, all observations should have a performer |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Bundle-MaxTOKS.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |
fsh-generated/resources/Observation-MaxGlasgowComaScale.json | UCUM Codes that contain human readable annotations like {score} can be misleading (e.g. they are ignored when comparing units). Best Practice is not to depend on annotations in the UCUM code, so this usage should be checked, and the Quantity.unit SHOULD contain the annotation |