HL7 FHIR Implementation Guide: DK Core, published by HL7 Denmark. This guide is not an authorized publication; it is the continuous build for version 3.5.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7dk/dk-core/ and changes regularly. See the Directory of published versions

ValueSet: Dk Core IEEE Basic Observation

Official URL: http://hl7.dk/fhir/core/ValueSet/dk-core-IEEEBasicObservation Version: 3.5.0
Draft as of 2025-11-24 Computable Name: IEEEBasicObservation

Copyright/Legal: This material contains content from IEEE-SA (https://standards.ieee.org/), copyright © the Insitute of Electrical and Electronics Engineers, Inc.

IEEE MDC codes for Basic Observations usable in Denmark

Purpose of this ValueSet

This ValueSet comprises the most common IEEE MDC codes used to represent observations that are considered "basic" by this profile. This ValueSet is not meant to be exhaustive!

The origin of an MDC code is usually the equipment used to perform the measurement, and often the code carries supplemental information about how (or where on the body) the observation was performed.

References

Logical Definition (CLD)

  • Include these codes as defined in urn:iso:std:iso:11073:10101 version Not Stated (use latest from terminology server)
    CodeDisplayFully specified name
    151562MDC_RESP_RATERate of breathing; method not specified.
    151570MDC_AWAY_RESP_RATERate of breathing; method: direct airway flow measurement.
    151578MDC_TTHOR_RESP_RATERate of breathing; method: transthoracic impedance variations.
    151594MDC_CO2_RESP_RATERate of breathing; method: carbon dioxide measurement.
    151602MDC_PRESS_RESP_RATERate of breathing; method: non-airway pressure measurement, e.g. central venous blood pressure (CVP).
    151650MDC_ACOUSTIC_RESP_RATERate of breathing; method: acoustic.
    151658MDC_PULS_OXIM_PLETH_RESP_RATERate of breathing; method: SpO2 plethysmography.
    8410992MDC_SABTE_RESP_RATEValue of respiration rate. [measured by sleep apnoea breathing therapy equipment]
    149514MDC_PULS_RATERate of blood pulse in an artery.
    149522MDC_BLD_PULS_RATE_INVRate of blood pulse in an artery, measured invasively.
    149546MDC_PULS_RATE_NON_INVRate of blood pulse in an artery, measured non-invasively.
    149530MDC_PULS_OXIM_PULS_RATERate of blood pulse as obtained by pulse oximetry.
    147842MDC_ECG_HEART_RATERate of cardiac beats (ECG).
    8410590MDC_ECG_HEART_RATE_INSTANTInstantaneous heart rate.
    149554MDC_TTHOR_HEART_RATEHeart rate obtained from the variation of transthoracic impedance.
    149562MDC_PALPATION_HEART_RATEHeart rate obtained from an artery that is close to the surface and a pulse can be felt.
    8454258MDC_HF_HRThis is an object representing the heart rate over a period of time. [Exercise / fitness equipment]
    150324MDC_SAT_O2_ARTArterial oxygen saturation. [no method]
    150456MDC_PULS_OXIM_SAT_O2Oxygen saturation. [using pulse oximetry]
    150364MDC_TEMP_BODYBody temperature. [unspecified]
    150368MDC_TEMP_CORECore temperature.
    150388MDC_TEMP_SKINSkin temperature.
    150392MDC_TEMP_TYMPTympanic temperature.
    188420MDC_TEMP_RECTRectal temperature.
    188424MDC_TEMP_ORALOral temperature.
    188428MDC_TEMP_EAREar temperature.
    188452MDC_TEMP_AXILLAAxillary (armpit) temperature.
    188456MDC_TEMP_GITGastro-intestinal tract temperature.
    188740MDC_LEN_BODY_ACTUALThe actual height of the patient.
    153856MDC_CIRCUM_HEADCircumference of the head.
    188736MDC_MASS_BODY_ACTUALThe measurement of the mass of patient.
    188752MDC_RATIO_MASS_BODY_LEN_SQThe individual's body weight, in kilograms, divided by the square of height, in meters.
    150020MDC_PRESS_BLD_NONINVPressure of the blood, obtained noninvasively.
    150021MDC_PRESS_BLD_NONINV_SYSPressure of the blood, obtained noninvasively, at the systolic phase.
    150022MDC_PRESS_BLD_NONINV_DIAPressure of the blood, obtained noninvasively, at the diastolic phase.
    150023MDC_PRESS_BLD_NONINV_MEANPressure of the blood, obtained noninvasively, as computed by averaging on one cycle.

 

Expansion

Expansion from tx.fhir.org based on codesystem ISO 11073-10101 Health informatics - Point-of-care version 2024-12-05

This value set contains 36 concepts

SystemCodeDisplay (da)statusJSONXML
urn:iso:std:iso:11073:10101  151562http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  151570http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  151578http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  151594http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  151602http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  151650http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  151658http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  8410992http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  149514http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  149522http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  149546http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  149530http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  147842http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  8410590http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  149554http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  149562http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  8454258http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150324http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150456http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150364http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150368http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150388http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150392http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188420http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188424http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188428http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188452http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188456http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188740http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  153856http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188736http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  188752http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150020http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150021http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150022http://devices.fhir.org/CodeSystem/MDC-concept-status#published
urn:iso:std:iso:11073:10101  150023http://devices.fhir.org/CodeSystem/MDC-concept-status#published

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code