HL7 FHIR Implementation Guide: DK Core
1.0.0 - trial-use
HL7 FHIR Implementation Guide: DK Core, published by HL7 Denmark. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7dk/dk-core/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.dk/fhir/core/StructureDefinition/dk-core-producent-id | Version: 1.0.0 | |||
Draft as of 2024-09-23 | Computable Name: ProducentId |
Offical MedCom code describing the producer of lab results
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Identifier
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | Identifier | |||
use | 0..1 | code | usual | official | temp | secondary | old (If known) Fixed Value: official | |
system | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID | |
value | 1..1 | string | The value that is unique | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | C | 0..* | Identifier | An identifier intended for computation ident-1: Identifier with no value has limited utility. If communicating that an identifier value has been suppressed or missing, the value element SHOULD be present with an extension indicating the missing semantic - e.g. data-absent-reason |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | ΣC | 1..1 | string | The value that is unique Example General: 123456 |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|5.0.0 from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | C | 0..* | Identifier | An identifier intended for computation ident-1: Identifier with no value has limited utility. If communicating that an identifier value has been suppressed or missing, the value element SHOULD be present with an extension indicating the missing semantic - e.g. data-absent-reason |
id | 0..1 | id | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: IdentifierTypeCodes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | ΣC | 1..1 | string | The value that is unique Example General: 123456 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|5.0.0 from the FHIR Standard | |
Identifier.type | extensible | IdentifierTypeCodeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard |
This structure is derived from Identifier
Differential View
This structure is derived from Identifier
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | Identifier | |||
use | 0..1 | code | usual | official | temp | secondary | old (If known) Fixed Value: official | |
system | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID | |
value | 1..1 | string | The value that is unique | |
Documentation for this format |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | C | 0..* | Identifier | An identifier intended for computation ident-1: Identifier with no value has limited utility. If communicating that an identifier value has been suppressed or missing, the value element SHOULD be present with an extension indicating the missing semantic - e.g. data-absent-reason |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | ΣC | 1..1 | string | The value that is unique Example General: 123456 |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|5.0.0 from the FHIR Standard |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | C | 0..* | Identifier | An identifier intended for computation ident-1: Identifier with no value has limited utility. If communicating that an identifier value has been suppressed or missing, the value element SHOULD be present with an extension indicating the missing semantic - e.g. data-absent-reason |
id | 0..1 | id | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: IdentifierTypeCodes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | ΣC | 1..1 | string | The value that is unique Example General: 123456 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|5.0.0 from the FHIR Standard | |
Identifier.type | extensible | IdentifierTypeCodeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard |
This structure is derived from Identifier
Other representations of profile: CSV, Excel, Schematron