CH LAB-Report (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-report/ and changes regularly. See the Directory of published versions
Changelog
All significant changes to this FHIR implementation guide will be documented on this page.
STU 1 Sequence - v1.0.0 (2024-12-17)
Changed / Updated
- #91: Missing slice of value[x] and component.value[x] in observation: value.ofType(boolean)
- #70: Limit image size to 20 megabytes: Add menu point and page 'Guidance'.
- #73: Results Blood Group: Add more examples
- #77: The graphic 'Resource Overview' has been removed.
- #78: CH LAB-Report Observation Blood Group - Definitions
- add example Bloodgroup panel with 2 dependent hasMember elements
- #92: Add Profile ChLabObservationBloodGroup with additional valueSets as candidates
- #93: Outcomment SetFmmandStatusRule in all profiles to set them to active.
- #94: Bundle 2-electrophoresis – JSON: section "Laboratory examinations" empty? no amendment: contains subsection "Chemistry studies (set)
- #95: Specimen.type: reduce the minimum cardinality of Specimen.type to 0.
- #96: Duplicate from #95, no amendment
- #99: Insert 'imposeProfile extension (to EU LAB)' into the ChLabReportServiceRequest profile'
- #100: Use Cases in English and other langs: Remove Fig. 1 Resource Overview diagram and place a link to Resource Overview in CH ELM on the profiles page.
- #102: Move referenceRanges from dGFR profiles into examples
- #103: Merge CDK-EPI profiles for males and females, parent is ChLabObservation_eGFR
- #104: Merge Erythrocytes distribuition width, MDRD and CDK-EPI profiles, take codes from valueSet. eGFR calculation uses different formulas with different parameters, the implementation guide uses 3 calculation methods.
- #108: Home: replace sex with (administrative) gender.
- #109: External links to FHIR spec: replace https://www.hl7.org/fhir/ with https://www.hl7.org/fhir/r4/
- #106: CodeableConcept.text with fixed value: remove code.text from all profiles
- #110: Terminology: empty sections: outcomment empty sections in terminology page
- #111: Terminology: Replace Profile name SpecimenAdditiveSubstance with ChLabSpecimenAdditiveSubstance
- #113: ChLab BloodGroup Antibody Screen Tests; 3 Value Sets are used by the Blood Group profile: CH LAB-Report BloodGroup Antibody Result (SNOMED CT coded substances), CH LAB-Report BloodGroup Immunohematology Tests (SNOMED CT coded procedures), CH LAB-Report BloodGroup Antibody Screen Test Result (LOINC codes)
- #114: Profiles: add links to LOINC Codes and NEJM in text of eGFR-CKD-EPI(ASR) 2021 Profile
- #115: Use Cases in English: No amendment, duplicate of #100
- #116: Changelog, refactor bloodgroup examples
Issues resolved without amendment (in IG)
- #97: Typo generated in narrative (tooling side)
STU 1 Sequence - v1.0.0-ballot (2024-05-17)
- #48: Exchange the conformsTo rules with the imposeProfile extension
- #49: Add the FHIR flame to the IG header
DSTU 1 Sequence - v0.1.1 (2023-12-28)
- #270: Technical correction for invalid package
- #52: Update to Version 0.2.0-ci of HL7 Europe Laboratory Report
- #73: Results Blood Group
- #76: eGFR CKD-EPI 2009 or 2021 formula:
- #68: Do we need Observation Panel Profiles?
- #92: Profile: ChLabObservationBloodGroup
- Add Antibody ValueSets:
- ValueSet: ChLabBloodGroupAntibody
- ValueSet: ChLabBloodGroupAntibodyScreen
- ValueSet: ChLabBloodGroupAntibodyScreen