CH EMS (R4)
2.1.0-ci-build - ci-build Switzerland flag

CH EMS (R4), published by IVR Interverband für Rettungswesen. This guide is not an authorized publication; it is the continuous build for version 2.1.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-ems/ and changes regularly. See the Directory of published versions

: EMS Handover to FHIR Mapping - XML Representation

Active as of 2025-09-01

Raw xml | Download


<ConceptMap xmlns="http://hl7.org/fhir">
  <id value="EmsHandover2Fhir"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ConceptMap EmsHandover2Fhir</b></p><a name="EmsHandover2Fhir"> </a><a name="hcEmsHandover2Fhir"> </a><p>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-document.html">CH EMS Document</a></p><br/><p><b>Group 1 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-composition.html">CH EMS Composition</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Composition.section:handover</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-observation-statuspriority.html">CH EMS Observation: Status Priority</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover.priority</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.valueCodeableConcept</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-observation-conditionchange.html">CH EMS Observation: Condition Change</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover.conditionChange</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.valueCodeableConcept</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-observation-naca.html">CH EMS Observation: NACA</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover.injurySeverity</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.valueCodeableConcept</td></tr></table><hr/><p><b>Group 5 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-observation-gcs.html">CH EMS Observation: GCS</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover.gcs.total</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.valueQuantity</td></tr><tr><td>EMSProtocol.handover.gcs.eyeOpening.score</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.component:eyeOpening.valueCodeableConcept.coding.extension:itemWeight</td></tr><tr><td>EMSProtocol.handover.gcs.eyeOpening.description</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.component:eyeOpening.valueCodeableConcept</td></tr><tr><td>EMSProtocol.handover.gcs.verbalResponse.score</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.component:verbal.valueCodeableConcept.coding.extension:itemWeight</td></tr><tr><td>EMSProtocol.handover.gcs.verbalResponse.description</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.component:verbal.valueCodeableConcept</td></tr><tr><td>EMSProtocol.handover.gcs.motorResponse.score</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.component:motor.valueCodeableConcept.coding.extension:itemWeight</td></tr><tr><td>EMSProtocol.handover.gcs.motorResponse.description</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Observation.component:motor.valueCodeableConcept</td></tr></table><hr/><p><b>Group 6 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-organization.html">CH EMS Organization</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover.recipient.organisation</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Organization</td></tr></table><hr/><p><b>Group 7 </b>Mapping from <a href="StructureDefinition-logicalmodel-ems-protocol.html">EMS Protocol</a> to <a href="StructureDefinition-ch-ems-practitioner.html">CH EMS Practitioner</a></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>EMSProtocol.handover.recipient.practitioner</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Practitioner</td></tr></table></div>
  </text>
  <url value="http://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir"/>
  <version value="2.1.0-ci-build"/>
  <name value="EmsHandover2Fhir"/>
  <title value="EMS Handover to FHIR Mapping"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2025-09-01T13:45:24+00:00"/>
  <publisher value="IVR Interverband für Rettungswesen"/>
  <contact>
    <name value="IVR Interverband für Rettungswesen"/>
    <telecom>
      <system value="url"/>
      <value value="https://www.ivr-ias.ch/"/>
    </telecom>
  </contact>
  <description
               value="This map shows how the handover section from the EMS Protocol is represented using FHIR."/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="CH"/>
    </coding>
  </jurisdiction>
  <copyright value="CC0-1.0"/>
  <sourceUri
             value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
  <targetUri
             value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-document"/>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-composition"/>
    <element>
      <code value="EMSProtocol.handover"/>
      <target>
        <code value="Composition.section:handover"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-statuspriority"/>
    <element>
      <code value="EMSProtocol.handover.priority"/>
      <target>
        <code value="Observation.valueCodeableConcept"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-conditionchange"/>
    <element>
      <code value="EMSProtocol.handover.conditionChange"/>
      <target>
        <code value="Observation.valueCodeableConcept"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-naca"/>
    <element>
      <code value="EMSProtocol.handover.injurySeverity"/>
      <target>
        <code value="Observation.valueCodeableConcept"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-gcs"/>
    <element>
      <code value="EMSProtocol.handover.gcs.total"/>
      <target>
        <code value="Observation.valueQuantity"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="EMSProtocol.handover.gcs.eyeOpening.score"/>
      <target>
        <code
              value="Observation.component:eyeOpening.valueCodeableConcept.coding.extension:itemWeight"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="EMSProtocol.handover.gcs.eyeOpening.description"/>
      <target>
        <code value="Observation.component:eyeOpening.valueCodeableConcept"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="EMSProtocol.handover.gcs.verbalResponse.score"/>
      <target>
        <code
              value="Observation.component:verbal.valueCodeableConcept.coding.extension:itemWeight"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="EMSProtocol.handover.gcs.verbalResponse.description"/>
      <target>
        <code value="Observation.component:verbal.valueCodeableConcept"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="EMSProtocol.handover.gcs.motorResponse.score"/>
      <target>
        <code
              value="Observation.component:motor.valueCodeableConcept.coding.extension:itemWeight"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
    <element>
      <code value="EMSProtocol.handover.gcs.motorResponse.description"/>
      <target>
        <code value="Observation.component:motor.valueCodeableConcept"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-organization"/>
    <element>
      <code value="EMSProtocol.handover.recipient.organisation"/>
      <target>
        <code value="Organization"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
  <group>
    <source
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol"/>
    <target
            value="http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-practitioner"/>
    <element>
      <code value="EMSProtocol.handover.recipient.practitioner"/>
      <target>
        <code value="Practitioner"/>
        <equivalence value="equivalent"/>
      </target>
    </element>
  </group>
</ConceptMap>