AU Core Implementation Guide
1.0.0-ci-build - CI Build Australia flag

AU Core Implementation Guide, published by HL7 Australia. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7au/au-fhir-core/ and changes regularly. See the Directory of published versions

Comparison with other national and international IGs

Page standards status: Informative

AU Core aligns to, and leverages, international standards and other national standards, in particular:

Relationships between AU Core, AUCDI, and the above key implementation guides is described in Relationship with other IGs.

Corresponding profiles, conformance requirements, and capability statements included in the key FHIR implementation guides were reviewed and considered during AU Core's development to ensure alignment, and to facilitate adoption of, this standard.

The below comparison evaluates AU Core conformance requirements with the key implementation guides identifying where compliance with AU Core satisfies the expectations established by the referenced implementation guide.

At this time only profile comparison is available. Future versions of AU Core will compare capability statements.

Profile comparison

As part of profile comparison, the requirements, constraints, and standards specified in a particular FHIR profile are evaluated. These requirements can include mandatory elements, cardinality constraints, data types, terminology bindings, usage rules, extensions, rules on missing or suppressed data.

The table below provides a profile only comparison from AU Core to profiles in key implementation guides. Compliance in the reverse direction is not guaranteed, i.e. a resource that is compliant with an International Patient Access profile MAY NOT be compliant with AU Core.

Legend:

Compliant: An AU Core compliant resource meets all requirements of the compared profile.

Additional requirements: An AU Core compliant resource is compatible, but additional changes may be needed to meet all requirements of the compared profile. Where additional requirements are identified, more information is provided in the sections below.

Incompatible: An AU Core compliant resource is incompatible with the compared profile. A resource cannot be compliant to both. Where incompatible requirements are identified, more information is provided in the sections below.

No equivalent profile: No equivalent profile for comparison.

AU Core International Patient Access 1.0.0 International Patient Summary 1.1.0 US Core 7.0.0
AU Core AllergyIntolerance
AU Core Blood Pressure
AU Core Body Height
AU Core Body Temperature
AU Core Body Weight
AU Core Condition
AU Core Diagnostic Result Observation
AU Core Encounter
AU Core Heart Rate
AU Core Immunization
AU Core Location
AU Core Medication
AU Core MedicationRequest
AU Core Organization
AU Core Pathology Result Observation
AU Core Patient
AU Core Practitioner
AU Core PractitionerRole
AU Core Procedure
AU Core Respiration Rate
AU Core Smoking Status
AU Core Waist Circumference

International Patient Access

International Patient Access 1.0.0 describes how an application acting on behalf of a patient can access patient information from a clinical records system using a FHIR-based API.

Incompatible requirements

The following IPA profile(s) contain incompatible requirements with the equivalent AU Core profile. Implementers are advised to note that substantial code changes may be required to support these profiles.

AU Core International Patient Access 1.0.0 Element Incompatible requirements
AU Core MedicationRequest IPA-MedicationRequest MedicationRequest.requester IPA prohibits reference to Organization and RelatedPerson resources.
Missing Data

AU Core compliant resources are compliant with IPA requirements for Missing Data.

Suppressed Data

IPA does not include requirements for Suppressed Data.

Additional profiles

This version of AU Core has no equivalent profile for the following IPA profiles:

  • IPA-DocumentReference
  • IPA-MedicationStatement

International Patient Summary

International Patient Summary Implementation Guide 1.1.0 describes how to represent the International Patient Summary (IPS) using HL7 FHIR. An International Patient Summary document is an electronic health record extract containing essential healthcare information about a subject of care.

Additional requirements

The following IPS profile(s) contain additional requirements. Implementers are advised to note that some code changes may be required to support these profiles.

AU Core International Patient Summary 1.1.0 Element Additional requirements
AU Core AllergyIntolerance Allergy Intolerance (IPS) AllergyIntolerance.patient.reference IPS requires minimum of 1.
AU Core Condition Condition (IPS) Condition.clinicalStatus IPS requires minimum of 1.
Condition.subject.reference IPS requires minimum of 1.
AU Core Diagnostic Result Observation Observation Results (IPS) Observation.status IPS requires value 'final'.
Observation.subject.reference IPS requires minimum of 1.
AU Core Immunization Immunization (IPS) Immunization.patient.reference IPS requires minimum of 1.
AU Core Medication Medication (IPS) Medication.ingredient.strength IPS requires UCUM for coded quantity units.
AU Core MedicationRequest Medication Request (IPS) MedicationRequest.subject.reference IPS requires minimum of 1.
AU Core Pathology Result Observation Observation Results: laboratory (IPS) Observation.status IPS requires value 'final'.
Observation.subject.reference IPS requires minimum of 1.
Observation.performer IPS requires minimum of 1.
Observation.value IPS requires UCUM for coded quantity units.
Observation Results: pathology (IPS) Observation.status IPS requires value 'final'.
Observation.subject.reference IPS requires minimum of 1.
Observation.performer IPS requires minimum of 1.
Observation.value IPS requires UCUM for coded quantity units.
AU Core Procedure Procedure (IPS) Procedure.subject.reference IPS requires minimum of 1.
Procedure.performed[x] IPS requires minimum of 1.
AU Core Smoking Status Observation - SH: tobacco use Observation.subject.reference IPS requires minimum of 1.
Observation.code IPS requires LOINC code 72166-2.
Observation.value[x] IPS requires value from Current Smoking Status - IPS.
Missing Data

AU Core compliant resources are compliant with IPS requirements for Missing Data.

Suppressed Data

IPS does not include requirements for Suppressed Data.

Additional profiles

This version of AU Core has no equivalent profile for the following IPS profiles:

  • Bundle - IPS
  • Composition (IPS)
  • Device (IPS)
  • Device - performer, observer
  • Device - performer, observer
  • DiagnosticReport (IPS)
  • Imaging Study (IPS)
  • Media observation (Results: laboratory, media)
  • Medication Statement (IPS)
  • Observation - Pregnancy: EDD
  • Observation - Pregnancy: outcome
  • Observation - Pregnancy: status
  • Observation - SH: alcohol use
  • Observation Results: radiology (IPS)
  • Specimen (IPS)

US Core

US Core Implementation Guide 7.0.0 serves as the foundation for FHIR implementation guides in the US Realm. It establishes the minimum constraints on FHIR resources to define US Core Profiles, specifying the required elements, extensions, vocabularies, and value sets, as well as their usage. It also outlines the minimum FHIR RESTful interactions needed to access patient data for each US Core Profile.

Additional requirements

The following US Core profile(s) contain additional requirements. Implementers are advised to note that some code changes may be required to support these profiles.

AU Core US Core 7.0.0 Element Additional requirements
AU Core Condition US Core Condition Problems and Health Concerns Profile Condition.category US Core requires category of 'problem-list-item' or 'health-concern'.
US Core Condition Encounter Diagnosis Profile Condition.category US Core requires category of 'encounter-diagnosis'.
AU Core Diagnostic Result Observation US Core Observation Clinical Result Profile Observation.code US Core extensible binding to LOINC Codes.
Observation.value[x] US Core requires UCUM for coded quantity units.
AU Core Encounter US Core Encounter Profile Encounter.type US Core requires minimum of 1.
AU Core Immunization US Core Immunization Profile Immunization.vaccineCode US Core extensible binding to CVX Vaccines Administered Vaccine Set.
AU Core Location US Core Location Profile Location.name US Core requires minimum of 1.
AU Core Medication US Core Medication Profile Medication.code US Core extensible binding to Medication Clinical Drug.
AU Core MedicationRequest US Core MedicationRequest Profile MedicationRequest.medicationCodeableConcept US Core extensible binding to Medication Clinical Drug.
AU Core Organization US Core Organization Profile Organization.active US Core requires minimum of 1.
AU Core Pathology Result Observation US Core Laboratory Result Observation Profile Observation.code US Core extensible binding to US Core Laboratory Test Codes.
Observation.referenceRange US Core requires UCUM for coded quantity units.
AU Core Patient US Core Patient Profile Patient.identifier US Core requires all identifiers to have system and value.
Patient.name US Core requires all name to have family or given or Data Absent Reason extension.
Gender identity US Core requires US Core Gender Identity extension.
Patient.telecom US Core requires all telecom to have system and value.
AU Core Practitioner US Core Practitioner Profile Practitioner.identifier US Core requires minimum of 1, and all identifiers to have system and value.
AU Core PractitionerRole US Core PractitionerRole Profile PractitionerRole.telecom, PractitionerRole.endpoint US Core requires telecom or endpoint to be present (pd-1).
PractitionerRole.telecom US Core requires all telecom to have system and value.
AU Core Smoking Status US Core Smoking Status Observation Profile Observation.status US Core requires status of 'final' or 'entered-in-error'.
Observation.code US Core extensible binding to Smoking Status Type.
Observation.value[x]:valueCodeableConcept US Core extensible binding to Smoking status comprehensive.
Missing Data

AU Core compliant resources are compliant with US Core requirements for Missing Data.

Suppressed Data

US Core does not include requirements for Suppressed Data.

Additional profiles

This version of AU Core has no equivalent profile for the following US Core profiles:

  • US Core CarePlan Profile
  • US Core CareTeam Profile
  • US Core Coverage Profile
  • US Core Implantable Device Profile
  • US Core DiagnosticReport Profile for Laboratory Results Reporting Profile
  • US Core DiagnosticReport Profile for Report and Note Exchange Profile
  • US Core DocumentReference Profile
  • US Core Goal Profile Profile
  • US Core MedicationDispense Profile
  • US Core Average Blood Pressure Profile
  • US Core Care Experience Preference Profile
  • US Core Observation Occupation Profile
  • US Core Observation Pregnancy Intent Profile
  • US Core Observation Pregnancy Status Profile
  • US Core Observation Screening Assessment Profile
  • US Core Observation Sexual Orientation Profile
  • US Core Simple Observation Profile
  • US Core Treatment Intervention Preference Profile
  • US Core Provenance Profile
  • US Core QuestionnaireResponse Profile
  • US Core ServiceRequest Profile
  • US Core Specimen Profile