Target Code System http://snomed.info/sct is only supported on the terminology server, so the target codes are not validated for performance reasonsCONCEPTMAP_GROUP_TARGET_SERVER_SIDE
The code 'C64432' comes from the system https://www.cdisc.org/standards/terminology/controlled-terminology which could not be found, so it's not known whether it's valid in the value set 'null'
The code 'C64433' comes from the system https://www.cdisc.org/standards/terminology/controlled-terminology which could not be found, so it's not known whether it's valid in the value set 'null'
The code 'C64467' comes from the system https://www.cdisc.org/standards/terminology/controlled-terminology which could not be found, so it's not known whether it's valid in the value set 'null'
The code '274161010000103' in the system http://snomed.info/sct is not valid in the value set 'null'CONCEPTMAP_VS_INVALID_CONCEPT_CODE
--
Resource
information
The resource ConceptMap/CdiscToSnomed could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Target Code System http://snomed.info/sct is only supported on the terminology server, so the target codes are not validated for performance reasonsCONCEPTMAP_GROUP_TARGET_SERVER_SIDE
The code '274161010000103' in the system http://snomed.info/sct is not valid in the value set 'null'CONCEPTMAP_VS_INVALID_CONCEPT_CODE
--
Resource
information
The resource ConceptMap/LoincToSnomed could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Source Code System http://snomed.info/sct is only supported on the terminology server, so the source codes are not validated for performance reasonsCONCEPTMAP_GROUP_SOURCE_SERVER_SIDE
The code 'C64432' comes from the system https://www.cdisc.org/standards/terminology/controlled-terminology which could not be found, so it's not known whether it's valid in the value set 'null'
The code 'C64433' comes from the system https://www.cdisc.org/standards/terminology/controlled-terminology which could not be found, so it's not known whether it's valid in the value set 'null'
The code 'C64467' comes from the system https://www.cdisc.org/standards/terminology/controlled-terminology which could not be found, so it's not known whether it's valid in the value set 'null'
--
Resource
information
The resource ConceptMap/SnomedToCdisc could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
Source Code System http://snomed.info/sct is only supported on the terminology server, so the source codes are not validated for performance reasonsCONCEPTMAP_GROUP_SOURCE_SERVER_SIDE
The code '274161010000103' in the system http://snomed.info/sct is not valid in the value set 'null'CONCEPTMAP_VS_INVALID_CONCEPT_CODE
--
Resource
information
The resource ConceptMap/SnomedToLoinc could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
ImplementationGuide/hl7.eu.fhir.xshare-ips-plus: ImplementationGuide: Validated against fhir.ImplementationGuide
Path
Severity
Message
Validating
Resource
information
The resource ImplementationGuide/hl7.eu.fhir.xshare-ips-plus could usefully have an OID assigned (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
The resource ValueSet/cdisc-all should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)
--
ValueSet.where(id = 'cdisc-all')
warning
Error from https://tx.fhir.org/r4: Error: A definition for CodeSystem 'https://www.cdisc.org/standards/terminology/controlled-terminology' could not be found, so the value set cannot be expanded (from server, see log)
The resource ValueSet/snomed-all should have an OID assigned to cater for possible use with OID based terminology systems e.g. CDA usage (OIDs are easy to assign - see https://build.fhir.org/ig/FHIR/fhir-tools-ig/CodeSystem-ig-parameters.html#ig-parameters-auto-oid-root)