HL7 Europe Imaging Study Report
0.1.0-build - ci-build 150

HL7 Europe Imaging Study Report, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 0.1.0-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/imaging/ and changes regularly. See the Directory of published versions

Logical Model: Imaging study model

Official URL: https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingStudy Version: 0.1.0
Draft as of 2025-08-05 Computable Name: EHDSImagingStudy

Copyright/Legal: Used by permission of HL7 Europe, all rights reserved Creative Commons License

EHDS refined base model for Imaging study

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. EHDSImagingStudy 0..* EHDSDataSet
Elements defined in Ancestors:header, presentedForm
Imaging study model
Instances of this logical model can be the target of a Reference
... header 1..1 Base Common header for all patient-related data
.... subject 1..1 EHDSPatient Subject
.... identifier 1..* Identifier Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier.
.... authorship 1..* Base Authorship
..... author[x] 1..1 Author
...... authorEHDSHealthProfessional EHDSHealthProfessional
...... authorEHDSOrganisation EHDSOrganisation
...... authorEHDSDevice EHDSDevice
..... datetime 1..1 dateTime Date and time of authoring/issuing
.... lastUpdate 0..1 dateTime Date and time of the last update to the resource
.... status 1..1 CodeableConcept Status of the resource
.... statusReason[x] 0..1 Reason for the current status of the resource.
..... statusReasonCodeableConcept CodeableConcept
..... statusReasonString string
.... language 0..1 CodeableConcept Language
Binding Description: (preferred): BCP 47
.... version 0..1 string Version
... presentedForm 0..* EHDSAttachment A narrative easy-to-read representation of the full data set, e.g. PDF-version of a document
... modality 0..* CodeableConcept All of the distinct values for series' modalities
Binding Description: (preferred): DICOM CID029
... started 0..1 dateTime Date and time the study started.
... basedOn 0..* EHDSServiceRequest References to the diagnostic requests that resulted in this imaging study being performed.
... numberOfSeries 0..1 integer Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
... numberOfInstances 0..1 integer Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
... description 0..1 string The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
... studyCustodian 0..1 EHDSOrganisation Organisation name, address, contact information.
... studyEndpoint 0..1 EHDSEndpoint Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
... series 0..* Base Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed
.... seriesUid 1..1 Identifier DICOM Series Instance UID for the series
.... number 0..1 integer Numeric identifier of this series
.... acquisitionModality 1..1 CodeableConcept Acquisition modality - the modality used for this series
Binding Description: (preferred): DICOM CID029
.... description 0..1 string A short human readable summary of the series
.... numberOfInstances 0..1 integer Number of Series Related Instances
.... seriesEndpoint 0..1 EHDSEndpoint Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
.... bodySite 0..1 EHDSBodyStructure Body part (with laterality) examined
.... specimen 0..* EHDSSpecimen Specimen imaged
.... started 0..1 dateTime When the series started
.... instancesInTheSeries 0..* Base Each series has one or more instances, but they may be absent when no instance information needs to be conveyed
..... instanceTitle 0..1 string Instance title that is the description of the instance.
..... instanceUid 1..1 Identifier DICOM SOP Instance UID
..... sopClass 1..1 uri SOP class - DICOM class type
..... instanceNumber 0..1 integer The number of this instance in the series
..... numberOfFrames 0..1 integer The number of frames in a multiframe instance

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
EHDSImagingStudy.header.languagepreferred
EHDSImagingStudy.modalitypreferred
EHDSImagingStudy.series.acquisitionModalitypreferred

This structure is derived from EHDSDataSet

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. EHDSImagingStudy 0..* EHDSDataSet
Elements defined in Ancestors:header, presentedForm
Imaging study model
Instances of this logical model can be the target of a Reference
... header
.... identifier 1..* Identifier Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier.
... modality 0..* CodeableConcept All of the distinct values for series' modalities
Binding Description: (preferred): DICOM CID029
... encounter 0..1 EHDSEncounter Reference to the encounter with which this imaging study is associated
... basedOn 0..* EHDSServiceRequest References to the diagnostic requests that resulted in this imaging study being performed.
... numberOfSeries 0..1 integer Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
... numberOfInstances 0..1 integer Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
... description 0..1 string The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
... studyCustodian 0..1 EHDSOrganisation Organisation name, address, contact information.
... studyEndpoint 0..1 EHDSEndpoint Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
... series 0..* Base Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed
.... seriesUid 1..1 Identifier DICOM Series Instance UID for the series
.... number 0..1 integer Numeric identifier of this series
.... acquisitionModality 1..1 CodeableConcept Acquisition modality - the modality used for this series
Binding Description: (preferred): DICOM CID029
.... description 0..1 string A short human readable summary of the series
.... numberOfInstances 0..1 integer Number of Series Related Instances
.... seriesEndpoint 0..1 EHDSEndpoint Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
.... bodySite 0..1 EHDSBodyStructure Body part (with laterality) examined
.... specimen 0..* EHDSSpecimen Specimen imaged
.... started 0..1 dateTime When the series started
.... instancesInTheSeries 0..* Base Each series has one or more instances, but they may be absent when no instance information needs to be conveyed
..... instanceTitle 0..1 string Instance title that is the description of the instance.
..... instanceUid 1..1 Identifier DICOM SOP Instance UID
..... sopClass 1..1 uri SOP class - DICOM class type
..... instanceNumber 0..1 integer The number of this instance in the series
..... numberOfFrames 0..1 integer The number of frames in a multiframe instance

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
EHDSImagingStudy.modalitypreferred
EHDSImagingStudy.series.acquisitionModalitypreferred
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. EHDSImagingStudy 0..* EHDSDataSet
Elements defined in Ancestors:header, presentedForm
Imaging study model
Instances of this logical model can be the target of a Reference
... header 1..1 Base Common header for all patient-related data
.... subject 1..1 EHDSPatient Subject
.... identifier 1..* Identifier Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier.
.... authorship 1..* Base Authorship
..... author[x] 1..1 Author
...... authorEHDSHealthProfessional EHDSHealthProfessional
...... authorEHDSOrganisation EHDSOrganisation
...... authorEHDSDevice EHDSDevice
..... datetime 1..1 dateTime Date and time of authoring/issuing
.... lastUpdate 0..1 dateTime Date and time of the last update to the resource
.... status 1..1 CodeableConcept Status of the resource
.... statusReason[x] 0..1 Reason for the current status of the resource.
..... statusReasonCodeableConcept CodeableConcept
..... statusReasonString string
.... language 0..1 CodeableConcept Language
Binding Description: (preferred): BCP 47
.... version 0..1 string Version
... presentedForm 0..* EHDSAttachment A narrative easy-to-read representation of the full data set, e.g. PDF-version of a document
... modality 0..* CodeableConcept All of the distinct values for series' modalities
Binding Description: (preferred): DICOM CID029
... started 0..1 dateTime Date and time the study started.
... basedOn 0..* EHDSServiceRequest References to the diagnostic requests that resulted in this imaging study being performed.
... numberOfSeries 0..1 integer Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
... numberOfInstances 0..1 integer Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
... description 0..1 string The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
... studyCustodian 0..1 EHDSOrganisation Organisation name, address, contact information.
... studyEndpoint 0..1 EHDSEndpoint Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
... series 0..* Base Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed
.... seriesUid 1..1 Identifier DICOM Series Instance UID for the series
.... number 0..1 integer Numeric identifier of this series
.... acquisitionModality 1..1 CodeableConcept Acquisition modality - the modality used for this series
Binding Description: (preferred): DICOM CID029
.... description 0..1 string A short human readable summary of the series
.... numberOfInstances 0..1 integer Number of Series Related Instances
.... seriesEndpoint 0..1 EHDSEndpoint Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
.... bodySite 0..1 EHDSBodyStructure Body part (with laterality) examined
.... specimen 0..* EHDSSpecimen Specimen imaged
.... started 0..1 dateTime When the series started
.... instancesInTheSeries 0..* Base Each series has one or more instances, but they may be absent when no instance information needs to be conveyed
..... instanceTitle 0..1 string Instance title that is the description of the instance.
..... instanceUid 1..1 Identifier DICOM SOP Instance UID
..... sopClass 1..1 uri SOP class - DICOM class type
..... instanceNumber 0..1 integer The number of this instance in the series
..... numberOfFrames 0..1 integer The number of frames in a multiframe instance

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
EHDSImagingStudy.header.languagepreferred
EHDSImagingStudy.modalitypreferred
EHDSImagingStudy.series.acquisitionModalitypreferred

This structure is derived from EHDSDataSet

Summary

Mandatory: 1 element(4 nested mandatory elements)

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. EHDSImagingStudy 0..* EHDSDataSet
Elements defined in Ancestors:header, presentedForm
Imaging study model
Instances of this logical model can be the target of a Reference
... header 1..1 Base Common header for all patient-related data
.... subject 1..1 EHDSPatient Subject
.... identifier 1..* Identifier Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier.
.... authorship 1..* Base Authorship
..... author[x] 1..1 Author
...... authorEHDSHealthProfessional EHDSHealthProfessional
...... authorEHDSOrganisation EHDSOrganisation
...... authorEHDSDevice EHDSDevice
..... datetime 1..1 dateTime Date and time of authoring/issuing
.... lastUpdate 0..1 dateTime Date and time of the last update to the resource
.... status 1..1 CodeableConcept Status of the resource
.... statusReason[x] 0..1 Reason for the current status of the resource.
..... statusReasonCodeableConcept CodeableConcept
..... statusReasonString string
.... language 0..1 CodeableConcept Language
Binding Description: (preferred): BCP 47
.... version 0..1 string Version
... presentedForm 0..* EHDSAttachment A narrative easy-to-read representation of the full data set, e.g. PDF-version of a document
... modality 0..* CodeableConcept All of the distinct values for series' modalities
Binding Description: (preferred): DICOM CID029
... started 0..1 dateTime Date and time the study started.
... basedOn 0..* EHDSServiceRequest References to the diagnostic requests that resulted in this imaging study being performed.
... numberOfSeries 0..1 integer Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
... numberOfInstances 0..1 integer Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
... description 0..1 string The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
... studyCustodian 0..1 EHDSOrganisation Organisation name, address, contact information.
... studyEndpoint 0..1 EHDSEndpoint Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
... series 0..* Base Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed
.... seriesUid 1..1 Identifier DICOM Series Instance UID for the series
.... number 0..1 integer Numeric identifier of this series
.... acquisitionModality 1..1 CodeableConcept Acquisition modality - the modality used for this series
Binding Description: (preferred): DICOM CID029
.... description 0..1 string A short human readable summary of the series
.... numberOfInstances 0..1 integer Number of Series Related Instances
.... seriesEndpoint 0..1 EHDSEndpoint Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
.... bodySite 0..1 EHDSBodyStructure Body part (with laterality) examined
.... specimen 0..* EHDSSpecimen Specimen imaged
.... started 0..1 dateTime When the series started
.... instancesInTheSeries 0..* Base Each series has one or more instances, but they may be absent when no instance information needs to be conveyed
..... instanceTitle 0..1 string Instance title that is the description of the instance.
..... instanceUid 1..1 Identifier DICOM SOP Instance UID
..... sopClass 1..1 uri SOP class - DICOM class type
..... instanceNumber 0..1 integer The number of this instance in the series
..... numberOfFrames 0..1 integer The number of frames in a multiframe instance

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
EHDSImagingStudy.header.languagepreferred
EHDSImagingStudy.modalitypreferred
EHDSImagingStudy.series.acquisitionModalitypreferred

Differential View

This structure is derived from EHDSDataSet

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. EHDSImagingStudy 0..* EHDSDataSet
Elements defined in Ancestors:header, presentedForm
Imaging study model
Instances of this logical model can be the target of a Reference
... header
.... identifier 1..* Identifier Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier.
... modality 0..* CodeableConcept All of the distinct values for series' modalities
Binding Description: (preferred): DICOM CID029
... encounter 0..1 EHDSEncounter Reference to the encounter with which this imaging study is associated
... basedOn 0..* EHDSServiceRequest References to the diagnostic requests that resulted in this imaging study being performed.
... numberOfSeries 0..1 integer Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
... numberOfInstances 0..1 integer Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
... description 0..1 string The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
... studyCustodian 0..1 EHDSOrganisation Organisation name, address, contact information.
... studyEndpoint 0..1 EHDSEndpoint Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
... series 0..* Base Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed
.... seriesUid 1..1 Identifier DICOM Series Instance UID for the series
.... number 0..1 integer Numeric identifier of this series
.... acquisitionModality 1..1 CodeableConcept Acquisition modality - the modality used for this series
Binding Description: (preferred): DICOM CID029
.... description 0..1 string A short human readable summary of the series
.... numberOfInstances 0..1 integer Number of Series Related Instances
.... seriesEndpoint 0..1 EHDSEndpoint Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
.... bodySite 0..1 EHDSBodyStructure Body part (with laterality) examined
.... specimen 0..* EHDSSpecimen Specimen imaged
.... started 0..1 dateTime When the series started
.... instancesInTheSeries 0..* Base Each series has one or more instances, but they may be absent when no instance information needs to be conveyed
..... instanceTitle 0..1 string Instance title that is the description of the instance.
..... instanceUid 1..1 Identifier DICOM SOP Instance UID
..... sopClass 1..1 uri SOP class - DICOM class type
..... instanceNumber 0..1 integer The number of this instance in the series
..... numberOfFrames 0..1 integer The number of frames in a multiframe instance

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
EHDSImagingStudy.modalitypreferred
EHDSImagingStudy.series.acquisitionModalitypreferred

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. EHDSImagingStudy 0..* EHDSDataSet
Elements defined in Ancestors:header, presentedForm
Imaging study model
Instances of this logical model can be the target of a Reference
... header 1..1 Base Common header for all patient-related data
.... subject 1..1 EHDSPatient Subject
.... identifier 1..* Identifier Identifiers for the Imaging Study such as DICOM Study Instance UID. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier.
.... authorship 1..* Base Authorship
..... author[x] 1..1 Author
...... authorEHDSHealthProfessional EHDSHealthProfessional
...... authorEHDSOrganisation EHDSOrganisation
...... authorEHDSDevice EHDSDevice
..... datetime 1..1 dateTime Date and time of authoring/issuing
.... lastUpdate 0..1 dateTime Date and time of the last update to the resource
.... status 1..1 CodeableConcept Status of the resource
.... statusReason[x] 0..1 Reason for the current status of the resource.
..... statusReasonCodeableConcept CodeableConcept
..... statusReasonString string
.... language 0..1 CodeableConcept Language
Binding Description: (preferred): BCP 47
.... version 0..1 string Version
... presentedForm 0..* EHDSAttachment A narrative easy-to-read representation of the full data set, e.g. PDF-version of a document
... modality 0..* CodeableConcept All of the distinct values for series' modalities
Binding Description: (preferred): DICOM CID029
... started 0..1 dateTime Date and time the study started.
... basedOn 0..* EHDSServiceRequest References to the diagnostic requests that resulted in this imaging study being performed.
... numberOfSeries 0..1 integer Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
... numberOfInstances 0..1 integer Number of Service-Object Pairs (SOP) Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
... description 0..1 string The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
... studyCustodian 0..1 EHDSOrganisation Organisation name, address, contact information.
... studyEndpoint 0..1 EHDSEndpoint Study endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
... series 0..* Base Series. Each study has one or more series of instances, but they may be absent when no series information needs to be conveyed
.... seriesUid 1..1 Identifier DICOM Series Instance UID for the series
.... number 0..1 integer Numeric identifier of this series
.... acquisitionModality 1..1 CodeableConcept Acquisition modality - the modality used for this series
Binding Description: (preferred): DICOM CID029
.... description 0..1 string A short human readable summary of the series
.... numberOfInstances 0..1 integer Number of Series Related Instances
.... seriesEndpoint 0..1 EHDSEndpoint Series endpoint describing the technical details of a location that can be connected to for the delivery/retrieval of information. Sufficient information is required to ensure that a connection can be made securely, and appropriate data transmitted as defined by the endpoint owner. These may be locally hosted services, regional services, or national service.
.... bodySite 0..1 EHDSBodyStructure Body part (with laterality) examined
.... specimen 0..* EHDSSpecimen Specimen imaged
.... started 0..1 dateTime When the series started
.... instancesInTheSeries 0..* Base Each series has one or more instances, but they may be absent when no instance information needs to be conveyed
..... instanceTitle 0..1 string Instance title that is the description of the instance.
..... instanceUid 1..1 Identifier DICOM SOP Instance UID
..... sopClass 1..1 uri SOP class - DICOM class type
..... instanceNumber 0..1 integer The number of this instance in the series
..... numberOfFrames 0..1 integer The number of frames in a multiframe instance

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
EHDSImagingStudy.header.languagepreferred
EHDSImagingStudy.modalitypreferred
EHDSImagingStudy.series.acquisitionModalitypreferred

This structure is derived from EHDSDataSet

Summary

Mandatory: 1 element(4 nested mandatory elements)

 

Other representations of profile: CSV, Excel