HL7 Europe Imaging Study Report
0.1.0 - ci-build 150

HL7 Europe Imaging Study Report, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/imaging/ and changes regularly. See the Directory of published versions

ConceptMap: Mapping of B Imaging study manifest data set (Experimental)

Official URL: http://hl7.eu/fhir/imaging/ConceptMap/B-ImagingstudyMnifestDataset Version: 0.1.0
Draft as of 2025-03-18 Computable Name: B

Copyright/Legal: Used by permission of HL7 Europe, all rights reserved Creative Commons License

This concept map defines the mapping between the eHN B Comparison Study section and the FHIR profiles.

Generated Narrative: ConceptMap B-ImagingstudyMnifestDataset

Mapping from B Imaging study manifest data set (eHN) to (not specified)


Group 1 Mapping from B Imaging study manifest data set (eHN) to ImagingStudy

Source CodeRelationshipTarget Code
studyInstanceUid (B.1.1 Study instance UID)is equivalent toidentifier[studyInstanceUid]
description (B.1.2 Description)is equivalent todescription
studyCustodian (B.1.3 Study custodian)is equivalent toperformer[custodian].actor
organizationName (B.1.3.1 Organization name)is equivalent toperformer[custodian].actor->name
address (B.1.3.2 Address)is equivalent toperformer[custodian].actor->address
contact (B.1.3.3 Contact information)is equivalent toperformer[custodian].actor->telecom
series (B.1.4 List of Series)is equivalent toseries
seriesDescription (B.1.4.1 Series Description)is equivalent toseries.description
seriesInstanceUid (B.1.4.2 Series Unique Identifier)is equivalent toseries.uid
modality (B.1.4.3 Modality)is equivalent toseries.modality
seriesNumber (B.1.4.5.1 Series Number)is equivalent toseries.number
seriesEndpoint (B.1.4.6 Series endpoint)is narrower thanendpoint (when all series use the same endpoint.)
seriesEndpoint (B.1.4.6 Series endpoint)is equivalent toseries.endpoint (when the endpoint is specific for the series.)
instance (B.1.4.7 List of Instances in the series)is equivalent toseries.instance
instanceGlobalUid (B.1.4.7.1 Instance Globally Unique Identifier)is equivalent toseries.instance.uid
instanceClassUid (B.1.4.7.2 Instance Class Globally Unique Identifier)is equivalent toseries.instance.sopClass
instanceNumber (B.1.4.7.3 Instance Number)is equivalent toseries.instance.number

Group 2 Mapping from B Imaging study manifest data set (eHN) to Radiation Dose Observation

Source CodeRelationshipTarget Code
radiationDoseInformation (B.1.4.4 Radiation dose information)is broader thancode (Code the radiation dose.)
radiationDoseInformation (B.1.4.4 Radiation dose information)is broader thanvalueQuantity (Dose value.)