EU Imaging Report R5
1.0.0-ballot - ci-build 150

EU Imaging Report R5, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/imaging-r5/ and changes regularly. See the Directory of published versions

: ImagingSelection: DICOM key image instance

Raw xml | Download


<ImagingSelection xmlns="http://hl7.org/fhir">
  <id value="KeyImageImagingSelectionDicomInstanceExample"/>
  <meta>
    <profile
             value="http://hl7.eu/fhir/imaging-r5/StructureDefinition/ImagingSelectionKeyImageEuImaging"/>
  </meta>
  <language value="en"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ImagingSelection KeyImageImagingSelectionDicomInstanceExample</b></p><a name="KeyImageImagingSelectionDicomInstanceExample"> </a><a name="hcKeyImageImagingSelectionDicomInstanceExample"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-ImagingSelectionKeyImageEuImaging.html">ImagingSelection: Key Image</a></p></div><p><b>Artifact Description</b>: </p><div><p>Representative ultrasound key image</p>
</div><p><b>Artifact Title</b>: Frame selected by the reporting radiologist for follow-up comparison.</p><p><b>status</b>: Available</p><p><b>subject</b>: <a href="Patient-PatientStructuredReport.html">3D TEE 2D(official) (no stated gender), DoB: 1976-04-29 ( 00 CARDIAC 2)</a></p><blockquote><p><b>performer</b></p><p><b>function</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v3-ParticipationType PRF}">Performer</span></p><p><b>actor</b>: <a href="PractitionerRole-PractitionerRoleStructuredReportAuthor.html">Ph.D. Philips van de JOCHEMSEN, Prof.(official): Cardiology at Ultrasound centrum</a></p></blockquote><blockquote><p><b>performer</b></p><p><b>function</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v3-ParticipationType DEV}">Device</span></p><p><b>actor</b>: <a href="Device-UltrasoundScannerExample.html">Device: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.113619.6.184.3.20260831.1; manufacturer = Example Medical Imaging; serialNumber = US-2026-0001; category = Diagnostic imaging equipment; type = Ultrasound</a></p></blockquote><p><b>code</b>: <span title="Codes:{http://dicom.nema.org/resources/ontology/DCM 113000}">Of Interest</span></p><p><b>studyUid</b>: 1.2.840.113619.2.5.1762583153.215519.978957063.110</p><p><b>derivedFrom</b>: <a href="ImagingStudy-ImagingStudyStructuredReport.html">ImagingStudy: extension = Upper trunk; identifier = Study Instance UID: DICOM Unique Id#urn:oid:1.3.46.670589.58.10.10562925256214266678.11674839624289915183; status = available; modality = Ultrasound; started = 2025-04-29</a></p><p><b>seriesUid</b>: 1.2.840.113619.2.5.1762583153.215519.978957063.120</p><h3>Instances</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Uid</b></td></tr><tr><td style="display: none">*</td><td>1.2.840.113619.2.5.1762583153.215519.978957063.121</td></tr></table></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/artifact-description">
    <valueMarkdown value="Representative ultrasound key image"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/artifact-title">
    <valueString
                 value="Frame selected by the reporting radiologist for follow-up comparison."/>
  </extension>
  <status value="available"/>
  <subject>🔗 
    <reference value="Patient/PatientStructuredReport"/>
  </subject>
  <performer>
    <function>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/>
        <code value="PRF"/>
        <display value="Performer"/>
      </coding>
    </function>
    <actor>🔗 
      <reference
                 value="PractitionerRole/PractitionerRoleStructuredReportAuthor"/>
    </actor>
  </performer>
  <performer>
    <function>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/>
        <code value="DEV"/>
        <display value="Device"/>
      </coding>
    </function>
    <actor>🔗 
      <reference value="Device/UltrasoundScannerExample"/>
    </actor>
  </performer>
  <code>
    <coding>
      <system value="http://dicom.nema.org/resources/ontology/DCM"/>
      <code value="113000"/>
      <display value="Of Interest"/>
    </coding>
  </code>
  <studyUid value="1.2.840.113619.2.5.1762583153.215519.978957063.110"/>
  <derivedFrom>🔗 
    <reference value="ImagingStudy/ImagingStudyStructuredReport"/>
  </derivedFrom>
  <seriesUid value="1.2.840.113619.2.5.1762583153.215519.978957063.120"/>
  <instance>
    <uid value="1.2.840.113619.2.5.1762583153.215519.978957063.121"/>
  </instance>
</ImagingSelection>