HL7 Europe Imaging Report R4
0.1.1-build - 150

HL7 Europe Imaging Report R4, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 0.1.1-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/imaging-r4/ and changes regularly. See the Directory of published versions

Resource Profile: Device: Imaging Device

Official URL: http://hl7.eu/fhir/imaging-r4/StructureDefinition/DeviceEuImaging Version: 0.1.1-build
Standards status: Draft Draft as of 2025-10-20 Maturity Level: 1 Computable Name: DeviceEuImaging

Copyright/Legal: Copyright HL7 Europe. Licensed under Creative Commons public domain (CC0 1.0).

The device the made the image.

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description Differentials, Snapshots, and other representations.

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... Slices for extension 1..* Extension Extension
Slice: Unordered, Open by value:url
.... extension:imagingCategory 1..1 (Complex) Indicates a high-level grouping of the device
URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category
Constraints: ext-1
..... extension 0..0
..... url 1..1 uri "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category"
..... value[x] 0..1 CodeableConcept Indicates a high-level grouping of the device
Binding: R5_device_category_for_R4 (0.0.1-snapshot-2) (example): Categories of medical devices.
Required Pattern: At least the following
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
...... coding 1..* Coding Code defined by a terminology system
Fixed Value: (Complex)
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
....... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
....... version 0..1 string Version of the system - if relevant
....... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 314789007
....... display 0..1 string Representation defined by the system
....... userSelected 0..1 boolean If this coding was chosen directly by the user
...... text 0..1 string Plain text representation of the concept
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... status ?!Σ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... manufacturer 0..1 string Name of device manufacturer
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... type 0..1 CodeableConcept The kind or type of device
Binding: ValueSet: Imaging Device Type (extensible)
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... value 1..1 string The version text

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.extension:imagingCategory.​value[x] Base example Cross-version VS for R5.FHIRDeviceCategory for use in FHIR R4 📍0.0.1-snapshot-2 FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 v0.0
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base extensible ValueSet: Imaging Device Type 📦0.1.1-build This IG

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... Slices for extension 1..* Extension Extension
Slice: Unordered, Open by value:url
.... extension:imagingCategory 1..1 (Complex) Indicates a high-level grouping of the device
URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category
..... extension 0..0
..... value[x] 0..1 CodeableConcept Indicates a high-level grouping of the device
Required Pattern: At least the following
...... coding 1..* Coding Code defined by a terminology system
Fixed Value: (Complex)
....... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
....... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 314789007
... identifier 0..* Identifier Instance identifier
... udiCarrier
.... deviceIdentifier 0..1 string Mandatory fixed portion of UDI
... manufacturer 0..1 string Name of device manufacturer
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
... type 0..1 CodeableConcept The kind or type of device
Binding: ValueSet: Imaging Device Type (extensible)
... version 0..* BackboneElement The actual design of the device or software version running on the device

doco Documentation for this format

Terminology Bindings (Differential)

Path Status Usage ValueSet Version Source
Device.type Base extensible ValueSet: Imaging Device Type 📦0.1.1-build This IG
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... Slices for extension 1..* Extension Extension
Slice: Unordered, Open by value:url
.... extension:imagingCategory 1..1 (Complex) Indicates a high-level grouping of the device
URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category
Constraints: ext-1
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..0
..... url 1..1 uri "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category"
..... value[x] 0..1 CodeableConcept Indicates a high-level grouping of the device
Binding: R5_device_category_for_R4 (0.0.1-snapshot-2) (example): Categories of medical devices.
Required Pattern: At least the following
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
...... coding 1..* Coding Code defined by a terminology system
Fixed Value: (Complex)
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
....... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
....... version 0..1 string Version of the system - if relevant
....... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 314789007
....... display 0..1 string Representation defined by the system
....... userSelected 0..1 boolean If this coding was chosen directly by the user
...... text 0..1 string Plain text representation of the concept
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier Σ 0..* BackboneElement Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ 0..1 string Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF Σ 0..1 string UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.
... status ?!Σ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
... distinctIdentifier 0..1 string The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber 0..1 string Lot number of manufacture
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type 0..1 CodeableConcept The kind or type of device
Binding: ValueSet: Imaging Device Type (extensible)
... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient 0..1 Reference(Patient) Patient to whom Device is affixed
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.extension:imagingCategory.​value[x] Base example Cross-version VS for R5.FHIRDeviceCategory for use in FHIR R4 📍0.0.1-snapshot-2 FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 v0.0
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base extensible ValueSet: Imaging Device Type 📦0.1.1-build This IG

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

Summary

Mandatory: 3 elements
Prohibited: 1 element

Extensions

This structure refers to these extensions:

Maturity: 1

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... Slices for extension 1..* Extension Extension
Slice: Unordered, Open by value:url
.... extension:imagingCategory 1..1 (Complex) Indicates a high-level grouping of the device
URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category
Constraints: ext-1
..... extension 0..0
..... url 1..1 uri "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category"
..... value[x] 0..1 CodeableConcept Indicates a high-level grouping of the device
Binding: R5_device_category_for_R4 (0.0.1-snapshot-2) (example): Categories of medical devices.
Required Pattern: At least the following
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
...... coding 1..* Coding Code defined by a terminology system
Fixed Value: (Complex)
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
....... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
....... version 0..1 string Version of the system - if relevant
....... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 314789007
....... display 0..1 string Representation defined by the system
....... userSelected 0..1 boolean If this coding was chosen directly by the user
...... text 0..1 string Plain text representation of the concept
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... status ?!Σ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... manufacturer 0..1 string Name of device manufacturer
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... type 0..1 CodeableConcept The kind or type of device
Binding: ValueSet: Imaging Device Type (extensible)
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... value 1..1 string The version text

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.extension:imagingCategory.​value[x] Base example Cross-version VS for R5.FHIRDeviceCategory for use in FHIR R4 📍0.0.1-snapshot-2 FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 v0.0
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base extensible ValueSet: Imaging Device Type 📦0.1.1-build This IG

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

Differential View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... Slices for extension 1..* Extension Extension
Slice: Unordered, Open by value:url
.... extension:imagingCategory 1..1 (Complex) Indicates a high-level grouping of the device
URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category
..... extension 0..0
..... value[x] 0..1 CodeableConcept Indicates a high-level grouping of the device
Required Pattern: At least the following
...... coding 1..* Coding Code defined by a terminology system
Fixed Value: (Complex)
....... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
....... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 314789007
... identifier 0..* Identifier Instance identifier
... udiCarrier
.... deviceIdentifier 0..1 string Mandatory fixed portion of UDI
... manufacturer 0..1 string Name of device manufacturer
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
... type 0..1 CodeableConcept The kind or type of device
Binding: ValueSet: Imaging Device Type (extensible)
... version 0..* BackboneElement The actual design of the device or software version running on the device

doco Documentation for this format

Terminology Bindings (Differential)

Path Status Usage ValueSet Version Source
Device.type Base extensible ValueSet: Imaging Device Type 📦0.1.1-build This IG

Snapshot ViewView

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. Device 0..* Device Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... Slices for extension 1..* Extension Extension
Slice: Unordered, Open by value:url
.... extension:imagingCategory 1..1 (Complex) Indicates a high-level grouping of the device
URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category
Constraints: ext-1
..... id 0..1 string Unique id for inter-element referencing
..... extension 0..0
..... url 1..1 uri "http://hl7.org/fhir/5.0/StructureDefinition/extension-Device.category"
..... value[x] 0..1 CodeableConcept Indicates a high-level grouping of the device
Binding: R5_device_category_for_R4 (0.0.1-snapshot-2) (example): Categories of medical devices.
Required Pattern: At least the following
...... id 0..1 string Unique id for inter-element referencing
...... extension 0..* Extension Additional content defined by implementations
...... coding 1..* Coding Code defined by a terminology system
Fixed Value: (Complex)
....... id 0..1 string Unique id for inter-element referencing
....... extension 0..* Extension Additional content defined by implementations
....... system 1..1 uri Identity of the terminology system
Fixed Value: http://snomed.info/sct
....... version 0..1 string Version of the system - if relevant
....... code 1..1 code Symbol in syntax defined by the system
Fixed Value: 314789007
....... display 0..1 string Representation defined by the system
....... userSelected 0..1 boolean If this coding was chosen directly by the user
...... text 0..1 string Plain text representation of the concept
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier Σ 0..* BackboneElement Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ 0..1 string Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF Σ 0..1 string UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.
... status ?!Σ 1..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
... distinctIdentifier 0..1 string The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate 0..1 dateTime Date when the device was made
... expirationDate 0..1 dateTime Date and time of expiry of this device (if applicable)
... lotNumber 0..1 string Lot number of manufacture
... serialNumber 0..1 string Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type 0..1 CodeableConcept The kind or type of device
Binding: ValueSet: Imaging Device Type (extensible)
... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient 0..1 Reference(Patient) Patient to whom Device is affixed
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.extension:imagingCategory.​value[x] Base example Cross-version VS for R5.FHIRDeviceCategory for use in FHIR R4 📍0.0.1-snapshot-2 FHIR Cross-Version Extensions package for FHIR R4 from FHIR R5 v0.0
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base extensible ValueSet: Imaging Device Type 📦0.1.1-build This IG

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

Summary

Mandatory: 3 elements
Prohibited: 1 element

Extensions

This structure refers to these extensions:

Maturity: 1

 

Other representations of profile: CSV, Excel, Schematron