Profile Comparison between http://hl7.eu/fhir/hdr/StructureDefinition/deviceUseStatement-obl-eu-hdr vs http://hl7.eu/fhir/hdr/StructureDefinition/deviceUseStatement-obl-eu-hdr

Left:DeviceUseStatement: obligations (http://hl7.eu/fhir/hdr/StructureDefinition/deviceUseStatement-obl-eu-hdr)
Right:DeviceUseStatement: obligations (http://hl7.eu/fhir/hdr/StructureDefinition/deviceUseStatement-obl-eu-hdr)

Messages

ErrorStructureDefinition.versionValues for version differ: '0.1.0-ballot' vs '1.0.0-ci'
InformationStructureDefinition.dateValues for date differ: '2025-06-03T12:48:49+02:00' vs '2026-06-26T06:41:56+00:00'
InformationStructureDefinition.copyrightValues for copyright differ: 'Used by permission of HL7 Europe, all rights reserved Creative Commons License' vs 'Copyright HL7 Europe. Licensed under creative commons public domain (CC0 1.0).'
InformationDeviceUseStatement.languageExample/preferred bindings differ at DeviceUseStatement.language using binding from DeviceUseStatementEuHdrObligation
InformationStructureDefinition.definitionValues for definition differ: 'The patient using the device.' vs 'The patient who used the device.'
InformationDeviceUseStatement.timing[x]Element minimum cardinalities differ: '1' vs '0'
InformationStructureDefinition.shortValues for short differ: 'Why is used (code)' vs 'Why device was used'
InformationStructureDefinition.shortValues for short differ: 'Why is used (details)' vs 'Why was DeviceUseStatement performed?'
InformationStructureDefinition.requirementsValues for requirements differ: 'Knowing where the device is targeted is important for tracking if multiple sites are possible. If more information than just a code is required, use the extension [http://hl7.org/fhir/StructureDefinition/bodySite](http://hl7.org/fhir/extension-bodysite.html).' vs 'EHDSDeviceUse.bodySite'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.eu/fhir/hdr/StructureDefinition/deviceUseStatement-eu-hdr
      .copyrightUsed by permission of HL7 Europe, all rights reserved Creative Commons LicenseCopyright HL7 Europe. Licensed under creative commons public domain (CC0 1.0).
      • Values Differ
      .date2025-06-03T12:48:49+02:002026-06-26T06:41:56+00:00
      • Values Differ
      .descriptionThis profile represents the constraints applied to the DeviceUseStatement resource for the purpose of this guide. A device used by or implanted on the patient is described in the hospital discharge report as an instance of a Device resource constrained by this profile.
        .experimental
          .fhirVersion4.0.1
            .jurisdiction
              ..jurisdiction[0]http://unstats.un.org/unsd/methods/m49/m49.htm#150
                .kindresource
                  .nameDeviceUseStatementEuHdrObligation
                    .publisherHL7 Europe
                      .purpose
                        .statusdraft
                          .titleDeviceUseStatement: obligations
                            .typeDeviceUseStatement
                              .urlhttp://hl7.eu/fhir/hdr/StructureDefinition/deviceUseStatement-obl-eu-hdr
                                .version0.1.0-ballot1.0.0-ci
                                • Values Differ

                                Structure

                                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.R TypeR Description & ConstraintsCommentsdoco
                                .. DeviceUseStatement 0..*DeviceUseStatementEuHdrRecord of use of a device
                                This profile also imposes the profile Device Use Statement (IPS)
                                0..*DeviceUseStatementEuHdrRecord of use of a device
                                  ... id Σ0..1idLogical id of this artifactΣ0..1idLogical id of this artifact
                                    ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                                      ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                                        ... text O0..1NarrativeDevice usage description
                                        This profile does not constrain the narrative in regard to content, language, or traceability to data elements
                                        ObligationsActor
                                        SHALL:handleHDRConsumer
                                        SHALL:able-to-populateHDRCreator
                                        0..1NarrativeDevice usage description
                                        This profile does not constrain the narrative in regard to content, language, or traceability to data elements
                                          ... contained 0..*ResourceContained, inline Resources
                                          0..*ResourceContained, inline Resources
                                            ... extension 0..*ExtensionAdditional content defined by implementations
                                            0..*ExtensionAdditional content defined by implementations
                                              ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                              ?!0..*ExtensionExtensions that cannot be ignored
                                                ... identifier Σ0..*IdentifierExternal identifier for this record
                                                Σ0..*IdentifierExternal identifier for this record
                                                  ... basedOn Σ0..*Reference(ServiceRequest)Fulfills plan, proposal or order
                                                  Σ0..*Reference(ServiceRequest)Fulfills plan, proposal or order
                                                    ... status ?!Σ1..1codeactive | completed | entered-in-error +
                                                    Binding: ?? (required): A coded concept indicating the current status of the Device Usage.
                                                    ?!OΣ1..1codeactive | completed | entered-in-error +
                                                    Binding: ?? (required): A coded concept indicating the current status of the Device Usage.
                                                    ObligationsActor
                                                    SHALL:able-to-populateProducer
                                                      ... subject OΣ1..1Reference(Patient (EU core))Patient using device
                                                      ObligationsActor
                                                      SHALL:handleHDRConsumer
                                                      SHALL:able-to-populateHDRCreator
                                                      OΣ1..1Reference(Patient: obligations)Patient using device
                                                      ObligationsActor
                                                      SHALL:able-to-populateProducer
                                                        .... id 0..1stringUnique id for inter-element referencing
                                                        • Removed this element
                                                        .... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                                        Slice: Unordered, Open by value:url
                                                        • Removed this element
                                                        .... reference ΣC1..1stringLiteral reference, Relative, internal or absolute URL
                                                        • Removed this element
                                                        .... type Σ0..1uriType the reference refers to (e.g. "Patient")
                                                        Binding: ?? (extensible): Aa resource (or, for logical models, the URI of the logical model).
                                                        • Removed this element
                                                        .... identifier Σ0..1IdentifierLogical reference, when literal reference is not known
                                                        • Removed this element
                                                        .... display Σ0..1stringText alternative for the resource
                                                        • Removed this element
                                                        ... derivedFrom Σ0..*Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference)Supporting information
                                                        Σ0..*Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference)Supporting information
                                                          ... timing[x] OΣ1..1Timing, Period, dateTimeHow often the device was used
                                                          ObligationsActor
                                                          SHALL:handleHDRConsumer
                                                          SHALL:able-to-populateHDRCreator
                                                          OΣ0..1Timing, Period, dateTimeHow often the device was used
                                                          Slice: Unordered, Closed by type:$this
                                                          ObligationsActor
                                                          SHOULD:able-to-populateProducer
                                                          • Element minimum cardinalities differ: '1' vs '0'
                                                          .... id 0..1stringUnique id for inter-element referencing
                                                          • Removed this element
                                                          .... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                                          Slice: Unordered, Open by value:url
                                                          • Removed this element
                                                          ... recordedOn Σ0..1dateTimeWhen statement was recordedΣ0..1dateTimeWhen statement was recorded
                                                            ... source Σ0..1Reference(Patient | Practitioner | PractitionerRole | RelatedPerson)Who made the statementΣ0..1Reference(Patient: obligations | Practitioner: obligations | PractitionerRole: obligations | RelatedPerson: obligations)Who made the statement
                                                              ... device OΣ1..1Reference(Device (HDR))Reference to device used
                                                              ObligationsActor
                                                              SHALL:handleHDRConsumer
                                                              SHOULD:able-to-populateHDRCreator
                                                              OΣ1..1Reference(Device: obligations)Reference to device used
                                                              ObligationsActor
                                                              SHALL:able-to-populateProducer
                                                                ... reasonCode OΣ0..*CodeableConceptWhy is used (code)
                                                                ObligationsActor
                                                                SHALL:handleHDRConsumer
                                                                MAY:able-to-populateHDRCreator
                                                                Σ0..*CodeableConceptWhy device was used
                                                                  ... reasonReference Σ0..*Reference(Condition (HDR) | Observation | Media | DiagnosticReport | DocumentReference)Why is used (details)
                                                                  Σ0..*Reference(Condition | Observation | DiagnosticReport | DocumentReference | Media)Why was DeviceUseStatement performed?
                                                                    ... bodySite OΣ0..1??Target body site
                                                                    Binding: ?? (preferred)
                                                                    ObligationsActor
                                                                    SHALL:handleHDRConsumer
                                                                    MAY:able-to-populateHDRCreator
                                                                    OΣ0..1CodeableConceptTarget body site
                                                                    Binding: ?? (preferred)
                                                                    ObligationsActor
                                                                    SHOULD:able-to-populateProducer
                                                                      ... note 0..*AnnotationAddition details (comments, instructions)
                                                                      O0..*AnnotationAddition details (comments, instructions)
                                                                      ObligationsActor
                                                                      SHOULD:able-to-populateProducer

                                                                        doco Documentation for this format