HL7 Europe Patient Summary, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/eps/ and changes regularly. See the Directory of published versions
Patient.identifier is required (1..*) in Patient (EPS) but has a populate-if-known obligation, and the History of Procedures and Medical Devices sections are required (1..1) in Composition (EPS) but have a SHOULD populate-if-known obligation. In these cases the cardinality of the profile applies.ihe.pharm.mpd.r4#1.0.0-comment-2). The dependency will be updated when a published version is available.compliesWithProfile.EHDSMedicationUse.dosageInstructions (1..1) is mapped to MedicationStatement.dosage (0..*) in MedicationStatement (EPS) (see the mapping).EHDSCurrentPregnancy.currentPregnancyStatus (1..1) is mapped to Observation.valueCodeableConcept (0..1) in Observation: Pregnancy - Status (EPS) (see the mapping).EHDSAdvanceDirective.header.subject (1..1) is mapped to Consent.patient (0..1) in Consent: Advance Directives (EPS) (see the mapping).EHDSDevice.type is 0..* in the model, while Device.type is 0..1 in FHIR R4 (see the mapping).