HL7 Europe Patient Summary, published by HL7 Europe. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7-eu/eps/ and changes regularly. See the Directory of published versions

Resource Profile: Device (EPS)

Official URL: http://hl7.eu/fhir/eps/StructureDefinition/device-eu-eps Version: 1.0.0-ci-build
Standards status: Draft Maturity Level: 1 Computable Name: DeviceEuEps

Copyright/Legal: Copyright HL7 Europe. Licensed under creative commons public domain (CC0 1.0).

This profile constrains the Device resource in the scope of the European Patient Summary.

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraints    Filter: doco
Device 0..* Device Item used in healthcare
This profile also imposes the profile Device (IPS)
Device.implicitRules This element is a modifier element. This element is included in summaries. 0..1 uri A set of rules under which this content was created
Device.modifierExtension This element is a modifier element. 0..* Extension Extensions that cannot be ignored
Device.identifier 0..* Identifier Device Identifier
Device.udiCarrier This element is included in summaries. 0..* BackboneElement Unique Device Identifier (UDI)
Device.udiCarrier.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.status This element is a modifier element. This element is included in summaries. 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
Device.manufacturer 0..1 string Device Manufacturer
Device.manufactureDate 0..1 dateTime Device Manufacture Date
Device.expirationDate 0..1 dateTime Device Expiration Date
Device.lotNumber 0..1 string Device Lot Number
Device.serialNumber 0..1 string Device Serial Number
Device.modelNumber 0..1 string Device Model Number
Device.type This element has obligations. 0..1 CodeableConcept Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set.
Binding: Medical Devices - IPS (preferred)
Additional BindingsPurpose
eHDSI Medical Device candidate
ObligationsActor
SHALL:populate-if-known Creator (IPS)
SHALL:handle Consumer (IPS)
SHOULD:display Consumer (IPS)
Device.note 0..* Annotation Device Note

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📦2.0.1 International Patient Summary Implementation Guide v2.0

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraints    Filter: doco
Device Device This profile also imposes the profile Device (IPS)
Device.identifier 0..* Identifier Device Identifier
Device.udiCarrier 0..* BackboneElement Unique Device Identifier (UDI)
Device.manufacturer 0..1 string Device Manufacturer
Device.expirationDate 0..1 dateTime Device Expiration Date
Device.lotNumber 0..1 string Device Lot Number
Device.serialNumber 0..1 string Device Serial Number
Device.deviceName
Device.deviceName.name 1..1 string Device Name
Device.modelNumber 0..1 string Device Model Number
Device.type This element has obligations. 0..1 CodeableConcept Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set.
Binding: Medical Devices - IPS (preferred)
Additional BindingsPurpose
eHDSI Medical Device candidate
ObligationsActor
SHALL:populate-if-known Creator (IPS)
SHALL:handle Consumer (IPS)
SHOULD:display Consumer (IPS)
Device.version
Device.version.value 1..1 string Device Version
Device.note 0..* Annotation Device Note

doco Documentation for this format

Terminology Bindings (Differential)

Path Status Usage ValueSet Version Source
Device.type Base preferred Medical Devices - IPS 📦2.0.1 International Patient Summary Implementation Guide v2.0
NameFlagsCard.TypeDescription & Constraints    Filter: doco
Device 0..* Device Item used in healthcare
This profile also imposes the profile Device (IPS)
Device.id This element is included in summaries. 0..1 id Logical id of this artifact
Device.meta This element is included in summaries. 0..1 Meta Metadata about the resource
Device.implicitRules This element is a modifier element. This element is included in summaries. 0..1 uri A set of rules under which this content was created
Device.language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
Device.text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
Device.contained 0..* Resource Contained, inline Resources
Device.extension 0..* Extension Additional content defined by implementations
Device.modifierExtension This element is a modifier element. 0..* Extension Extensions that cannot be ignored
Device.identifier 0..* Identifier Device Identifier
Device.definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
Device.udiCarrier This element is included in summaries. 0..* BackboneElement Unique Device Identifier (UDI)
Device.udiCarrier.id 0..1 string Unique id for inter-element referencing
Device.udiCarrier.extension 0..* Extension Additional content defined by implementations
Device.udiCarrier.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.udiCarrier.deviceIdentifier This element is included in summaries. 0..1 string Mandatory fixed portion of UDI
Device.udiCarrier.issuer 0..1 uri UDI Issuing Organization
Device.udiCarrier.jurisdiction 0..1 uri Regional UDI authority
Device.udiCarrier.carrierAIDC This element is included in summaries. 0..1 base64Binary UDI Machine Readable Barcode String
Device.udiCarrier.carrierHRF This element is included in summaries. 0..1 string UDI Human Readable Barcode String
Device.udiCarrier.entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.
Device.status This element is a modifier element. This element is included in summaries. 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
Device.statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
Device.distinctIdentifier 0..1 string The distinct identification string
Device.manufacturer 0..1 string Device Manufacturer
Device.manufactureDate 0..1 dateTime Device Manufacture Date
Device.expirationDate 0..1 dateTime Device Expiration Date
Device.lotNumber 0..1 string Device Lot Number
Device.serialNumber 0..1 string Device Serial Number
Device.deviceName 0..* BackboneElement The name of the device as given by the manufacturer
Device.deviceName.id 0..1 string Unique id for inter-element referencing
Device.deviceName.extension 0..* Extension Additional content defined by implementations
Device.deviceName.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.deviceName.name 1..1 string Device Name
Device.deviceName.type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
Device.modelNumber 0..1 string Device Model Number
Device.partNumber 0..1 string The part number of the device
Device.type This element has obligations. 0..1 CodeableConcept Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set.
Binding: Medical Devices - IPS (preferred)
Additional BindingsPurpose
eHDSI Medical Device candidate
ObligationsActor
SHALL:populate-if-known Creator (IPS)
SHALL:handle Consumer (IPS)
SHOULD:display Consumer (IPS)
Device.specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
Device.specialization.id 0..1 string Unique id for inter-element referencing
Device.specialization.extension 0..* Extension Additional content defined by implementations
Device.specialization.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.specialization.systemType 1..1 CodeableConcept The standard that is used to operate and communicate
Device.specialization.version 0..1 string The version of the standard that is used to operate and communicate
Device.version 0..* BackboneElement The actual design of the device or software version running on the device
Device.version.id 0..1 string Unique id for inter-element referencing
Device.version.extension 0..* Extension Additional content defined by implementations
Device.version.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.version.type 0..1 CodeableConcept The type of the device version
Device.version.component 0..1 Identifier A single component of the device version
Device.version.value 1..1 string Device Version
Device.property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
Device.property.id 0..1 string Unique id for inter-element referencing
Device.property.extension 0..* Extension Additional content defined by implementations
Device.property.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.property.type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
Device.property.valueQuantity 0..* Quantity Property value as a quantity
Device.property.valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
Device.patient 0..1 Reference(Patient) Patient to whom Device is affixed
Device.owner 0..1 Reference(Organization) Organization responsible for device
Device.contact 0..* ContactPoint Details for human/organization for support
Device.location 0..1 Reference(Location) Where the device is found
Device.url 0..1 uri Network address to contact device
Device.note 0..* Annotation Device Note
Device.safety This element is included in summaries. 0..* CodeableConcept Safety Characteristics of Device
Device.parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📦2.0.1 International Patient Summary Implementation Guide v2.0

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from Device

Summary

Maturity: 1

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: doco
Device 0..* Device Item used in healthcare
This profile also imposes the profile Device (IPS)
Device.implicitRules This element is a modifier element. This element is included in summaries. 0..1 uri A set of rules under which this content was created
Device.modifierExtension This element is a modifier element. 0..* Extension Extensions that cannot be ignored
Device.identifier 0..* Identifier Device Identifier
Device.udiCarrier This element is included in summaries. 0..* BackboneElement Unique Device Identifier (UDI)
Device.udiCarrier.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.status This element is a modifier element. This element is included in summaries. 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
Device.manufacturer 0..1 string Device Manufacturer
Device.manufactureDate 0..1 dateTime Device Manufacture Date
Device.expirationDate 0..1 dateTime Device Expiration Date
Device.lotNumber 0..1 string Device Lot Number
Device.serialNumber 0..1 string Device Serial Number
Device.modelNumber 0..1 string Device Model Number
Device.type This element has obligations. 0..1 CodeableConcept Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set.
Binding: Medical Devices - IPS (preferred)
Additional BindingsPurpose
eHDSI Medical Device candidate
ObligationsActor
SHALL:populate-if-known Creator (IPS)
SHALL:handle Consumer (IPS)
SHOULD:display Consumer (IPS)
Device.note 0..* Annotation Device Note

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📦2.0.1 International Patient Summary Implementation Guide v2.0

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

Differential View

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraints    Filter: doco
Device Device This profile also imposes the profile Device (IPS)
Device.identifier 0..* Identifier Device Identifier
Device.udiCarrier 0..* BackboneElement Unique Device Identifier (UDI)
Device.manufacturer 0..1 string Device Manufacturer
Device.manufactureDate 0..1 dateTime Device Manufacture Date
Device.expirationDate 0..1 dateTime Device Expiration Date
Device.lotNumber 0..1 string Device Lot Number
Device.serialNumber 0..1 string Device Serial Number
Device.deviceName
Device.deviceName.name 1..1 string Device Name
Device.modelNumber 0..1 string Device Model Number
Device.type This element has obligations. 0..1 CodeableConcept Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set.
Binding: Medical Devices - IPS (preferred)
Additional BindingsPurpose
eHDSI Medical Device candidate
ObligationsActor
SHALL:populate-if-known Creator (IPS)
SHALL:handle Consumer (IPS)
SHOULD:display Consumer (IPS)
Device.version
Device.version.value 1..1 string Device Version
Device.note 0..* Annotation Device Note

doco Documentation for this format

Terminology Bindings (Differential)

Path Status Usage ValueSet Version Source
Device.type Base preferred Medical Devices - IPS 📦2.0.1 International Patient Summary Implementation Guide v2.0

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: doco
Device 0..* Device Item used in healthcare
This profile also imposes the profile Device (IPS)
Device.id This element is included in summaries. 0..1 id Logical id of this artifact
Device.meta This element is included in summaries. 0..1 Meta Metadata about the resource
Device.implicitRules This element is a modifier element. This element is included in summaries. 0..1 uri A set of rules under which this content was created
Device.language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.
Additional BindingsPurpose
AllLanguages Max Binding
Device.text 0..1 Narrative Text summary of the resource, for human interpretation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
Device.contained 0..* Resource Contained, inline Resources
Device.extension 0..* Extension Additional content defined by implementations
Device.modifierExtension This element is a modifier element. 0..* Extension Extensions that cannot be ignored
Device.identifier 0..* Identifier Device Identifier
Device.definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
Device.udiCarrier This element is included in summaries. 0..* BackboneElement Unique Device Identifier (UDI)
Device.udiCarrier.id 0..1 string Unique id for inter-element referencing
Device.udiCarrier.extension 0..* Extension Additional content defined by implementations
Device.udiCarrier.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.udiCarrier.deviceIdentifier This element is included in summaries. 0..1 string Mandatory fixed portion of UDI
Device.udiCarrier.issuer 0..1 uri UDI Issuing Organization
Device.udiCarrier.jurisdiction 0..1 uri Regional UDI authority
Device.udiCarrier.carrierAIDC This element is included in summaries. 0..1 base64Binary UDI Machine Readable Barcode String
Device.udiCarrier.carrierHRF This element is included in summaries. 0..1 string UDI Human Readable Barcode String
Device.udiCarrier.entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.
Device.status This element is a modifier element. This element is included in summaries. 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.
Device.statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.
Device.distinctIdentifier 0..1 string The distinct identification string
Device.manufacturer 0..1 string Device Manufacturer
Device.manufactureDate 0..1 dateTime Device Manufacture Date
Device.expirationDate 0..1 dateTime Device Expiration Date
Device.lotNumber 0..1 string Device Lot Number
Device.serialNumber 0..1 string Device Serial Number
Device.deviceName 0..* BackboneElement The name of the device as given by the manufacturer
Device.deviceName.id 0..1 string Unique id for inter-element referencing
Device.deviceName.extension 0..* Extension Additional content defined by implementations
Device.deviceName.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.deviceName.name 1..1 string Device Name
Device.deviceName.type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.
Device.modelNumber 0..1 string Device Model Number
Device.partNumber 0..1 string The part number of the device
Device.type This element has obligations. 0..1 CodeableConcept Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set.
Binding: Medical Devices - IPS (preferred)
Additional BindingsPurpose
eHDSI Medical Device candidate
ObligationsActor
SHALL:populate-if-known Creator (IPS)
SHALL:handle Consumer (IPS)
SHOULD:display Consumer (IPS)
Device.specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
Device.specialization.id 0..1 string Unique id for inter-element referencing
Device.specialization.extension 0..* Extension Additional content defined by implementations
Device.specialization.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.specialization.systemType 1..1 CodeableConcept The standard that is used to operate and communicate
Device.specialization.version 0..1 string The version of the standard that is used to operate and communicate
Device.version 0..* BackboneElement The actual design of the device or software version running on the device
Device.version.id 0..1 string Unique id for inter-element referencing
Device.version.extension 0..* Extension Additional content defined by implementations
Device.version.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.version.type 0..1 CodeableConcept The type of the device version
Device.version.component 0..1 Identifier A single component of the device version
Device.version.value 1..1 string Device Version
Device.property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
Device.property.id 0..1 string Unique id for inter-element referencing
Device.property.extension 0..* Extension Additional content defined by implementations
Device.property.modifierExtension This element is a modifier element. This element is included in summaries. 0..* Extension Extensions that cannot be ignored even if unrecognized
Device.property.type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
Device.property.valueQuantity 0..* Quantity Property value as a quantity
Device.property.valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
Device.patient 0..1 Reference(Patient) Patient to whom Device is affixed
Device.owner 0..1 Reference(Organization) Organization responsible for device
Device.contact 0..* ContactPoint Details for human/organization for support
Device.location 0..1 Reference(Location) Where the device is found
Device.url 0..1 uri Network address to contact device
Device.note 0..* Annotation Device Note
Device.safety This element is included in summaries. 0..* CodeableConcept Safety Characteristics of Device
Device.parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

Path Status Usage ValueSet Version Source
Device.language Base preferred Common Languages 📍4.0.1 FHIR Std.
Device.udiCarrier.entryType Base required UDIEntryType 📍4.0.1 FHIR Std.
Device.status Base required FHIRDeviceStatus 📍4.0.1 FHIR Std.
Device.statusReason Base extensible FHIRDeviceStatusReason 📍4.0.1 FHIR Std.
Device.deviceName.type Base required DeviceNameType 📍4.0.1 FHIR Std.
Device.type Base preferred Medical Devices - IPS 📦2.0.1 International Patient Summary Implementation Guide v2.0

Constraints

Id Grade Path(s) Description Expression
dom-2 error Device If the resource is contained in another resource, it SHALL NOT contain nested Resources contained.contained.empty()
dom-3 error Device If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4 error Device If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5 error Device If a resource is contained in another resource, it SHALL NOT have a security label contained.meta.security.empty()
dom-6 best practice Device A resource should have narrative for robust management text.`div`.exists()
ele-1 error **ALL** elements All FHIR elements must have a @value or children hasValue() or (children().count() > id.count())
ext-1 error **ALL** extensions Must have either extensions or value[x], not both extension.exists() != value.exists()

This structure is derived from Device

Summary

Maturity: 1

 

Other representations of profile: CSV, Excel, Schematron