eHealth Infrastructure, published by Den telemedicinske infrastruktur (eHealth Infrastructure). This guide is not an authorized publication; it is the continuous build for version 3.3.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/fut-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions
Official URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device | Version: 3.3.0 | |||
Active as of 2024-12-20 | Computable Name: ehealth-device |
This resource identifies a specific instance of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device. Medical devices include durable (reusable) medical equipment, implantable devices, as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health. Non-medical devices may include items such as a machine, cellphone, computer, application, etc.
Because the Device resource represents a specific instance of a Device, it must have at least one identifier, such as a serial no., which together with the manufacturer and model uniquely identifies the device instance.
Each Device can be related to a number of suppliers with different roles; such as e.g. the provisioner, and suppliers of user training, maintenance, or decommissioning of the device.
In eHealth Devices are registered as FHIR resources when they are actively used in a current CarePlan for a Patient. The relation between a CarePlan and a Device is represented by a DeviceUseStatement resource.
The main purpose of registering a specific Device to a Patient through a CarePlan is purely clinical; not logistical. If for example at some point it is determined that a specific device has yielded erroneous or biased measurements, it may be important to track which patients have used this device.
Device resources are created and updated automatically based on actions and information provided in the Service, Support & Logistics (SSL) domain of the eHealth Infrastructure. The use of Device therefore concerns reading and searching only.
The SSL services manage the lifecycle of Device resources. When the SSL services receive a message that a device has been delivered to a patient, then the SSL services create a Device resource and relate it to the Patient's CarePlan through a DeviceUseStatement.
Bring your own device (BYOD), where the patient provides the device him or herself, is indicated with the extension Device.privatelyOwned
being set to true
. In all other cases, it is set to null
or false
.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Device
Path | Conformance | ValueSet | URI |
Device.type | required | DeviceTypeshttp://ehealth.sundhed.dk/vs/device-types from this IG |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
privatelyOwned | 0..1 | boolean | True if this device is owned or provided by the patient. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
suppliers | 0..* | (Complex) | Different types of suppliers for a device. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-suppliers ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
status | ?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
type | 0..1 | CodeableConcept | The kind or type of device Binding: Device Types (required) ele-1: All FHIR elements must have a @value or children | |
owner | 0..1 | Reference(ehealth-organization) {r} | Organization responsible for device ele-1: All FHIR elements must have a @value or children | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | required | DeviceTypeshttp://ehealth.sundhed.dk/vs/device-types from this IG |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
privatelyOwned | 0..1 | boolean | True if this device is owned or provided by the patient. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned | |||||
suppliers | 0..* | (Complex) | Different types of suppliers for a device. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-suppliers | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||
manufacturer | 0..1 | string | Name of device manufacturer | |||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name of the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The model number for the device | |||||
partNumber | 0..1 | string | The part number of the device | |||||
type | 0..1 | CodeableConcept | The kind or type of device Binding: Device Types (required) | |||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
owner | 0..1 | Reference(ehealth-organization) {r} | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for author[x] | Σ | 0..1 | Individual responsible for the annotation Slice: Unordered, Closed by type:$this | |||||
authorReference | Reference(Practitioner | Patient | RelatedPerson | Organization) | |||||||
authorString | string | |||||||
author[x]:authorReference | Σ | 0..1 | Reference(ehealth-practitioner | ehealth-patient | ehealth-relatedperson) | Individual responsible for the annotation | ||||
author[x]:authorString | Σ | 0..1 | string | Individual responsible for the annotation | ||||
time | Σ | 0..1 | dateTime | When the annotation was made | ||||
text | Σ | 1..1 | markdown | The annotation - text content (as markdown) | ||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The parent device | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | DeviceTypeshttp://ehealth.sundhed.dk/vs/device-types from this IG |
This structure is derived from Device
Summary
Mandatory: 1 element
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Differential View
This structure is derived from Device
Path | Conformance | ValueSet | URI |
Device.type | required | DeviceTypeshttp://ehealth.sundhed.dk/vs/device-types from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
privatelyOwned | 0..1 | boolean | True if this device is owned or provided by the patient. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
suppliers | 0..* | (Complex) | Different types of suppliers for a device. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-suppliers ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
status | ?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. ele-1: All FHIR elements must have a @value or children |
type | 0..1 | CodeableConcept | The kind or type of device Binding: Device Types (required) ele-1: All FHIR elements must have a @value or children | |
owner | 0..1 | Reference(ehealth-organization) {r} | Organization responsible for device ele-1: All FHIR elements must have a @value or children | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.type | required | DeviceTypeshttp://ehealth.sundhed.dk/vs/device-types from this IG |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Device | 0..* | Device | Item used in healthcare | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
privatelyOwned | 0..1 | boolean | True if this device is owned or provided by the patient. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned | |||||
suppliers | 0..* | (Complex) | Different types of suppliers for a device. URL: http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-suppliers | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | 0..* | Identifier | Instance identifier | |||||
definition | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
udiCarrier | Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
issuer | 0..1 | uri | UDI Issuing Organization | |||||
jurisdiction | 0..1 | uri | Regional UDI authority | |||||
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
status | ?!Σ | 1..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
statusReason | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
distinctIdentifier | 0..1 | string | The distinct identification string | |||||
manufacturer | 0..1 | string | Name of device manufacturer | |||||
manufactureDate | 0..1 | dateTime | Date when the device was made | |||||
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
lotNumber | 0..1 | string | Lot number of manufacture | |||||
serialNumber | 0..1 | string | Serial number assigned by the manufacturer | |||||
deviceName | 0..* | BackboneElement | The name of the device as given by the manufacturer | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
name | 1..1 | string | The name of the device | |||||
type | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
modelNumber | 0..1 | string | The model number for the device | |||||
partNumber | 0..1 | string | The part number of the device | |||||
type | 0..1 | CodeableConcept | The kind or type of device Binding: Device Types (required) | |||||
specialization | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
systemType | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
version | 0..1 | string | The version of the standard that is used to operate and communicate | |||||
version | 0..* | BackboneElement | The actual design of the device or software version running on the device | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 0..1 | CodeableConcept | The type of the device version | |||||
component | 0..1 | Identifier | A single component of the device version | |||||
value | 1..1 | string | The version text | |||||
property | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
type | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
valueQuantity | 0..* | Quantity | Property value as a quantity | |||||
valueCode | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
owner | 0..1 | Reference(ehealth-organization) {r} | Organization responsible for device | |||||
contact | 0..* | ContactPoint | Details for human/organization for support | |||||
location | 0..1 | Reference(Location) | Where the device is found | |||||
url | 0..1 | uri | Network address to contact device | |||||
note | 0..* | Annotation | Device notes and comments | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for author[x] | Σ | 0..1 | Individual responsible for the annotation Slice: Unordered, Closed by type:$this | |||||
authorReference | Reference(Practitioner | Patient | RelatedPerson | Organization) | |||||||
authorString | string | |||||||
author[x]:authorReference | Σ | 0..1 | Reference(ehealth-practitioner | ehealth-patient | ehealth-relatedperson) | Individual responsible for the annotation | ||||
author[x]:authorString | Σ | 0..1 | string | Individual responsible for the annotation | ||||
time | Σ | 0..1 | dateTime | When the annotation was made | ||||
text | Σ | 1..1 | markdown | The annotation - text content (as markdown) | ||||
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
parent | 0..1 | Reference(Device) | The parent device | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Device.language | preferred | CommonLanguageshttp://hl7.org/fhir/ValueSet/languages from the FHIR Standard
| ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | DeviceTypeshttp://ehealth.sundhed.dk/vs/device-types from this IG |
This structure is derived from Device
Summary
Mandatory: 1 element
Prohibited: 1 element
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron