SMART Imaging Access
0.1.0 - ci-build International flag

SMART Imaging Access, published by Argonaut Project. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/argonautproject/smart-imaging/ and changes regularly. See the Directory of published versions

Example Bundle: ImagingStudy search response

Bundle imaging-search-response of type searchset


Entry 1 - fullUrl = https://imaging.example.org/fhir/ImagingStudy/imaging-study-contained-endpoint

Search:Mode = match

Resource ImagingStudy:

identifier: DICOM Unique Id/urn:oid:1.2.840.99999999.19341866.1571297684

status: Available

modality: Computed Tomography

subject: Jason Argonaut (no stated gender), DoB Unknown ( http://hospital.example.org/mrn#8675309)

started: 2023-02-24 14:02:49+0000

endpoint: Endpoint: extension = true; status = active; connectionType = DICOM WADO-RS; address = https://imaging.example.org/wado-rs

numberOfSeries: 1

numberOfInstances: 3

series

uid: 1.2.840.99999999.19341866.1571297684.1

number: 1

modality: Computed Tomography

numberOfInstances: 3

instance

uid: 1.2.840.99999999.19341866.1571297684.1.1

sopClass: unknown: urn:oid:1.2.840.10008.5.1.4.1.1.2 (urn:oid:1.2.840.10008.5.1.4.1.1.2)

number: 1

instance

uid: 1.2.840.99999999.19341866.1571297684.1.2

sopClass: unknown: urn:oid:1.2.840.10008.5.1.4.1.1.2 (urn:oid:1.2.840.10008.5.1.4.1.1.2)

number: 2

instance

uid: 1.2.840.99999999.19341866.1571297684.1.3

sopClass: unknown: urn:oid:1.2.840.10008.5.1.4.1.1.2 (urn:oid:1.2.840.10008.5.1.4.1.1.2)

number: 3


Requires Access Token: true

status: Active

connectionType: DICOM WADO-RS

address: https://imaging.example.org/wado-rs


Entry 2 - fullUrl = https://imaging.example.org/fhir/ImagingStudy/imaging-study-external-endpoint

Search:Mode = match

Resource ImagingStudy:

identifier: DICOM Unique Id/urn:oid:1.2.840.99999999.82943819.1948573621

status: Available

modality: Magnetic Resonance

subject: Jason Argonaut (no stated gender), DoB Unknown ( http://hospital.example.org/mrn#8675309)

started: 2023-05-11 09:30:00+0000

endpoint: Endpoint: extension = true; status = active; connectionType = DICOM WADO-RS (Endpoint Connection Type#dicom-wado-rs); payloadType = Any; address = https://pacs.example.org/dicom-web

numberOfSeries: 1

numberOfInstances: 1

series

uid: 1.2.840.99999999.82943819.1948573621.1

number: 1

modality: Magnetic Resonance

numberOfInstances: 1

Instances

-UidSopClassNumber
*1.2.840.99999999.82943819.1948573621.1.1unknown: urn:oid:1.2.840.10008.5.1.4.1.1.4 (urn:oid:1.2.840.10008.5.1.4.1.1.4)1

Entry 3 - fullUrl = https://imaging.example.org/fhir/Endpoint/wado-endpoint-example

Search:Mode = include

Resource Endpoint:

Requires Access Token: true

status: Active

connectionType: DICOM WADO-RS

address: https://pacs.example.org/dicom-web