WHO Antenatal Care Guideline Implementation Guide
0.3.0 - CI Build
WHO Antenatal Care Guideline Implementation Guide, published by World Health Organization (WHO). This guide is not an authorized publication; it is the continuous build for version 0.3.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/WorldHealthOrganization/smart-anc/ and changes regularly. See the Directory of published versions
Official URL: http://fhir.org/guides/who/anc-cds/StructureDefinition/anc-b8-de19 | Version: 0.3.0 | |||
Draft as of 2024-09-10 | Computable Name: Diastolicbloodpressure | |||
Usage:Workflow Task: Physical exam |
Diastolic blood pressure (DBP) in mmHg
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from ANCObservation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | ANCObservation | Measurements and simple assertions | |
code | S | 1..1 | CodeableConcept | Diastolic blood pressure Binding: Diastolic blood pressure (required) |
value[x] | S | 0..1 | Quantity | Diastolic blood pressure |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.code | required | Diastolicbloodpressurehttp://fhir.org/guides/who/anc-cds/ValueSet/anc-b8-de19 from this IG |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | ANCObservation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | Content/Rules for all slices | |||
instantiatesCaseFeature | S | 0..1 | canonical(StructureDefinition) | Definition of this case feature URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-instantiatesCaseFeature |
caseFeatureType | S | 0..1 | code | asserted | inferred URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeatureType Binding: CPG Case Feature Type (required): Whether the case feature is asserted or inferred |
caseFeaturePertinence | S | 0..1 | code | weakly-positive | weakly-negative | strongly-positive | strongly-negative | pathognomonic URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeaturePertinence Binding: CPG Case Feature Pertinence (required): Describes the pertinence of a case feature |
pertinent | S | 0..* | Reference() | Pertinent information URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-pertinent |
bodyPosition | S | 0..1 | CodeableConcept | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | SΣ | 1..* | Identifier | Business Identifier for observation |
use | ?!SΣ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
system | SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
value | SΣ | 1..1 | string | The value that is unique Example General: 123456 |
basedOn | SΣ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
code | SΣ | 1..1 | CodeableConcept | Diastolic blood pressure Binding: Diastolic blood pressure (required) |
subject | SΣ | 1..1 | Reference(ANC Patient) | Who and/or what the observation is about |
encounter | SΣ | 0..1 | Reference(ANC Encounter) | Healthcare event during which this observation is made |
effective[x] | SΣ | 0..1 | Clinically relevant time/time-period for observation | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
effectiveTiming | Timing | |||
effectiveInstant | instant | |||
issued | SΣ | 0..1 | instant | Date/Time this version was made available |
value[x] | SΣC | 0..1 | Quantity | Diastolic blood pressure |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. |
bodySite | S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. |
method | S | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. |
specimen | S | 0..1 | Reference(Specimen) | Specimen used for this observation |
device | S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device |
referenceRange | SC | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | SC | 0..1 | SimpleQuantity | Low Range, if relevant |
high | SC | 0..1 | SimpleQuantity | High Range, if relevant |
derivedFrom | SΣ | 0..* | Reference(ANC Observation | CPGQuestionnaireResponse) | Related measurements the observation is made from |
component | SΣ | 0..* | BackboneElement | Component results |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
value[x] | SΣ | 0..1 | Actual component result | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. |
referenceRange | S | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | required | Diastolicbloodpressurehttp://fhir.org/guides/who/anc-cds/ValueSet/anc-b8-de19 from this IG | |
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | |
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | |
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | |
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | ANCObservation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
instantiatesCaseFeature | S | 0..1 | canonical(StructureDefinition) | Definition of this case feature URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-instantiatesCaseFeature | ||||
caseFeatureType | S | 0..1 | code | asserted | inferred URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeatureType Binding: CPG Case Feature Type (required): Whether the case feature is asserted or inferred | ||||
caseFeaturePertinence | S | 0..1 | code | weakly-positive | weakly-negative | strongly-positive | strongly-negative | pathognomonic URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeaturePertinence Binding: CPG Case Feature Pertinence (required): Describes the pertinence of a case feature | ||||
pertinent | S | 0..* | Reference() | Pertinent information URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-pertinent | ||||
bodyPosition | S | 0..1 | CodeableConcept | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | SΣ | 1..* | Identifier | Business Identifier for observation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
use | ?!SΣ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
system | SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
value | SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
period | Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
basedOn | SΣ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
code | SΣ | 1..1 | CodeableConcept | Diastolic blood pressure Binding: Diastolic blood pressure (required) | ||||
subject | SΣ | 1..1 | Reference(ANC Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | SΣ | 0..1 | Reference(ANC Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣ | 0..1 | Clinically relevant time/time-period for observation | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period | |||||||
effectiveTiming | Timing | |||||||
effectiveInstant | instant | |||||||
issued | SΣ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(ANC Practitioner | ANC PractitionerRole | ANC Patient | ANC RelatedPerson) | Who is responsible for the observation | ||||
value[x] | SΣC | 0..1 | Quantity | Diastolic blood pressure | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | ||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | ||||
method | S | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | ||||
specimen | S | 0..1 | Reference(Specimen) | Specimen used for this observation | ||||
device | S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | ||||
referenceRange | SC | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | SC | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | SC | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | SΣ | 0..* | Reference(ANC Observation | CPGQuestionnaireResponse) | Related measurements the observation is made from | ||||
component | SΣ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | SΣ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | ||||
referenceRange | S | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | ||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Observation.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | required | Diastolicbloodpressurehttp://fhir.org/guides/who/anc-cds/ValueSet/anc-b8-de19 from this IG | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() |
This structure is derived from ANCObservation
Differential View
This structure is derived from ANCObservation
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | ANCObservation | Measurements and simple assertions | |
code | S | 1..1 | CodeableConcept | Diastolic blood pressure Binding: Diastolic blood pressure (required) |
value[x] | S | 0..1 | Quantity | Diastolic blood pressure |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.code | required | Diastolicbloodpressurehttp://fhir.org/guides/who/anc-cds/ValueSet/anc-b8-de19 from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | ANCObservation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | Content/Rules for all slices | |||
instantiatesCaseFeature | S | 0..1 | canonical(StructureDefinition) | Definition of this case feature URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-instantiatesCaseFeature |
caseFeatureType | S | 0..1 | code | asserted | inferred URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeatureType Binding: CPG Case Feature Type (required): Whether the case feature is asserted or inferred |
caseFeaturePertinence | S | 0..1 | code | weakly-positive | weakly-negative | strongly-positive | strongly-negative | pathognomonic URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeaturePertinence Binding: CPG Case Feature Pertinence (required): Describes the pertinence of a case feature |
pertinent | S | 0..* | Reference() | Pertinent information URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-pertinent |
bodyPosition | S | 0..1 | CodeableConcept | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | SΣ | 1..* | Identifier | Business Identifier for observation |
use | ?!SΣ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
system | SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient |
value | SΣ | 1..1 | string | The value that is unique Example General: 123456 |
basedOn | SΣ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. |
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
code | SΣ | 1..1 | CodeableConcept | Diastolic blood pressure Binding: Diastolic blood pressure (required) |
subject | SΣ | 1..1 | Reference(ANC Patient) | Who and/or what the observation is about |
encounter | SΣ | 0..1 | Reference(ANC Encounter) | Healthcare event during which this observation is made |
effective[x] | SΣ | 0..1 | Clinically relevant time/time-period for observation | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
effectiveTiming | Timing | |||
effectiveInstant | instant | |||
issued | SΣ | 0..1 | instant | Date/Time this version was made available |
value[x] | SΣC | 0..1 | Quantity | Diastolic blood pressure |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. |
bodySite | S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. |
method | S | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. |
specimen | S | 0..1 | Reference(Specimen) | Specimen used for this observation |
device | S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device |
referenceRange | SC | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
low | SC | 0..1 | SimpleQuantity | Low Range, if relevant |
high | SC | 0..1 | SimpleQuantity | High Range, if relevant |
derivedFrom | SΣ | 0..* | Reference(ANC Observation | CPGQuestionnaireResponse) | Related measurements the observation is made from |
component | SΣ | 0..* | BackboneElement | Component results |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. |
value[x] | SΣ | 0..1 | Actual component result | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. |
referenceRange | S | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | required | Diastolicbloodpressurehttp://fhir.org/guides/who/anc-cds/ValueSet/anc-b8-de19 from this IG | |
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | |
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | |
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | |
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | ANCObservation | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
instantiatesCaseFeature | S | 0..1 | canonical(StructureDefinition) | Definition of this case feature URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-instantiatesCaseFeature | ||||
caseFeatureType | S | 0..1 | code | asserted | inferred URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeatureType Binding: CPG Case Feature Type (required): Whether the case feature is asserted or inferred | ||||
caseFeaturePertinence | S | 0..1 | code | weakly-positive | weakly-negative | strongly-positive | strongly-negative | pathognomonic URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-caseFeaturePertinence Binding: CPG Case Feature Pertinence (required): Describes the pertinence of a case feature | ||||
pertinent | S | 0..* | Reference() | Pertinent information URL: http://hl7.org/fhir/uv/cpg/StructureDefinition/cpg-pertinent | ||||
bodyPosition | S | 0..1 | CodeableConcept | The body position during the observation URL: http://hl7.org/fhir/StructureDefinition/observation-bodyPosition | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | SΣ | 1..* | Identifier | Business Identifier for observation | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
use | ?!SΣ | 1..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. | ||||
system | SΣ | 1..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
value | SΣ | 1..1 | string | The value that is unique Example General: 123456 | ||||
period | Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
basedOn | SΣ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ||||
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
code | SΣ | 1..1 | CodeableConcept | Diastolic blood pressure Binding: Diastolic blood pressure (required) | ||||
subject | SΣ | 1..1 | Reference(ANC Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | SΣ | 0..1 | Reference(ANC Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣ | 0..1 | Clinically relevant time/time-period for observation | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period | |||||||
effectiveTiming | Timing | |||||||
effectiveInstant | instant | |||||||
issued | SΣ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(ANC Practitioner | ANC PractitionerRole | ANC Patient | ANC RelatedPerson) | Who is responsible for the observation | ||||
value[x] | SΣC | 0..1 | Quantity | Diastolic blood pressure | ||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | ||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | S | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | ||||
method | S | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | ||||
specimen | S | 0..1 | Reference(Specimen) | Specimen used for this observation | ||||
device | S | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | ||||
referenceRange | SC | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | SC | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | SC | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | ||||
derivedFrom | SΣ | 0..* | Reference(ANC Observation | CPGQuestionnaireResponse) | Related measurements the observation is made from | ||||
component | SΣ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | SΣ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | S | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | ||||
referenceRange | S | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | ||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Observation.identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | required | Diastolicbloodpressurehttp://fhir.org/guides/who/anc-cds/ValueSet/anc-b8-de19 from this IG | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | Observation | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | Observation | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | Observation | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | Observation | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() | |
obs-3 | error | Observation.referenceRange | Must have at least a low or a high or text : low.exists() or high.exists() or text.exists() | |
obs-6 | error | Observation | dataAbsentReason SHALL only be present if Observation.value[x] is not present : dataAbsentReason.empty() or value.empty() | |
obs-7 | error | Observation | If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present : value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty() |
This structure is derived from ANCObservation
Other representations of profile: CSV, Excel, Schematron