WHO Antenatal Care Guideline Implementation Guide
0.3.0 - CI Build International flag

WHO Antenatal Care Guideline Implementation Guide, published by World Health Organization (WHO). This guide is not an authorized publication; it is the continuous build for version 0.3.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/WorldHealthOrganization/smart-anc/ and changes regularly. See the Directory of published versions

PlanDefinition: ANC.DT.14 Other

Official URL: http://fhir.org/guides/who/anc-cds/PlanDefinition/ANCDT14 Version: 0.3.0
Active as of 2021-06-11 Computable Name: ANCDT14
Other Identifiers: ANC.DT.14 (use: official, )

Usage:Workflow Task: Diagnosis and treatment

Additional blood tests

Id: ANCDT14
Url: ANC.DT.14 Other
Version: 0.3.0
Identifier:

value: ANC.DT.14

Name: ANCDT14
Title: ANC.DT.14 Other
Status: active
Experimental: false
Type:

system: http://terminology.hl7.org/CodeSystem/plan-definition-type

code: eca-rule

Date: 2021-06-11 23:02:59-0600
Publisher: World Health Organization (WHO)
Description: Additional blood tests
Use Context:
codevaluedisplay
task ANC.B10.4. Diagnosis and treatment
Jurisdiction: 001
Libraries:
ANC.DT.14 Other
Actions:
ANC.DT.14 Other:
When: Named Event: ANC.B10.4. Diagnosis and treatment
Then:
Hematocrit levels too low!
If: Applicability: "Hematocrit (Ht)" < 20% (Should Follow-up steps/investigations: clinician's discretion)
White blood cell count too high!
If: Applicability: "White blood cell (WBC) count" > 16 000 (Should Follow-up steps/investigations: clinician's discretion 2)
Platelet count too low!
If: Applicability: "Platelet count" < 100 000 cells/microlitre (μl) (Should Follow-up steps/investigations: clinician's discretion 3)