Virtually Healthcare HL7 FHIR Implementation Guide
0.1.0-current - ci-build
Virtually Healthcare HL7 FHIR Implementation Guide, published by Virtually Healthcare. This guide is not an authorized publication; it is the continuous build for version 0.1.0-current built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/Virtually-Healthcare/Virtually-Healthcare-FHIR-Implementation-Guide/ and changes regularly. See the Directory of published versions
Official URL: https://fhir.virtually.healthcare/StructureDefinition/medical-record-number | Version: 0.1.0-current | |||
Draft as of 2024-11-06 | Computable Name: MedicalRecordNumber |
Only use in FHIR Reference if the NHS Number is not known or unverified.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Identifier
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | Identifier | |||
type | 0..1 | CodeableConcept | Description of identifier Fixed Value: As shown (Medical record number) | |
coding | 1..1 | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: MR | |
system | 1..1 | uri | Should indicate the assigning provider of the MRN. This is provider defined. Binding: Medical Record System (required) | |
value | 1..1 | string | The value that is unique | |
assigner | 0..1 | Reference(Organization) | Populate if the identifier.value is reused by multiple providers (as is the case with EMIS identifiers) | |
identifier | 0..1 | OrganisationCode | An identifier intended for computation | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Identifier.system | required | MedicalRecordSystem (a valid code from Medical Record System)https://fhir.virtually.healthcare/ValueSet/MedicalRecordSystem from this IG |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Fixed Value: As shown (Medical record number) |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
coding | 1..1 | Coding | Code defined by a terminology system Fixed Value: (complex) | |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
version | 0..0 | string | Version of the system - if relevant | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: MR | |
display | 0..0 | string | Representation defined by the system | |
userSelected | 0..0 | boolean | If this coding was chosen directly by the user | |
text | 0..0 | string | Plain text representation of the concept | |
system | Σ | 1..1 | uri | Should indicate the assigning provider of the MRN. This is provider defined. Binding: Medical Record System (required) Example General: http://www.acme.com/identifiers/patient |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
assigner | Σ | 0..1 | Reference(Organization) | Populate if the identifier.value is reused by multiple providers (as is the case with EMIS identifiers) |
identifier | 0..1 | OrganisationCode | An identifier intended for computation | |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Identifier.type | extensible | Fixed Value: MRhttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Identifier.system | required | MedicalRecordSystem (a valid code from Medical Record System)https://fhir.virtually.healthcare/ValueSet/MedicalRecordSystem from this IG |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Fixed Value: As shown (Medical record number) |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
coding | 1..1 | Coding | Code defined by a terminology system Fixed Value: (complex) | |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
version | 0..0 | string | Version of the system - if relevant | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: MR | |
display | 0..0 | string | Representation defined by the system | |
userSelected | 0..0 | boolean | If this coding was chosen directly by the user | |
text | 0..0 | string | Plain text representation of the concept | |
system | Σ | 1..1 | uri | Should indicate the assigning provider of the MRN. This is provider defined. Binding: Medical Record System (required) Example General: http://www.acme.com/identifiers/patient |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Populate if the identifier.value is reused by multiple providers (as is the case with EMIS identifiers) |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
reference | ΣC | 0..1 | string | Literal reference, Relative, internal or absolute URL |
type | Σ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). |
identifier | 0..1 | OrganisationCode | An identifier intended for computation | |
display | Σ | 0..1 | string | Text alternative for the resource |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Identifier.type | extensible | Fixed Value: MRhttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Identifier.system | required | MedicalRecordSystem (a valid code from Medical Record System)https://fhir.virtually.healthcare/ValueSet/MedicalRecordSystem from this IG | |
Identifier.assigner.type | extensible | ResourceTypehttp://hl7.org/fhir/ValueSet/resource-types from the FHIR Standard |
This structure is derived from Identifier
Differential View
This structure is derived from Identifier
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | Identifier | |||
type | 0..1 | CodeableConcept | Description of identifier Fixed Value: As shown (Medical record number) | |
coding | 1..1 | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: MR | |
system | 1..1 | uri | Should indicate the assigning provider of the MRN. This is provider defined. Binding: Medical Record System (required) | |
value | 1..1 | string | The value that is unique | |
assigner | 0..1 | Reference(Organization) | Populate if the identifier.value is reused by multiple providers (as is the case with EMIS identifiers) | |
identifier | 0..1 | OrganisationCode | An identifier intended for computation | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Identifier.system | required | MedicalRecordSystem (a valid code from Medical Record System)https://fhir.virtually.healthcare/ValueSet/MedicalRecordSystem from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Fixed Value: As shown (Medical record number) |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
coding | 1..1 | Coding | Code defined by a terminology system Fixed Value: (complex) | |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
version | 0..0 | string | Version of the system - if relevant | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: MR | |
display | 0..0 | string | Representation defined by the system | |
userSelected | 0..0 | boolean | If this coding was chosen directly by the user | |
text | 0..0 | string | Plain text representation of the concept | |
system | Σ | 1..1 | uri | Should indicate the assigning provider of the MRN. This is provider defined. Binding: Medical Record System (required) Example General: http://www.acme.com/identifiers/patient |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
assigner | Σ | 0..1 | Reference(Organization) | Populate if the identifier.value is reused by multiple providers (as is the case with EMIS identifiers) |
identifier | 0..1 | OrganisationCode | An identifier intended for computation | |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Identifier.type | extensible | Fixed Value: MRhttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Identifier.system | required | MedicalRecordSystem (a valid code from Medical Record System)https://fhir.virtually.healthcare/ValueSet/MedicalRecordSystem from this IG |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Fixed Value: As shown (Medical record number) |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
coding | 1..1 | Coding | Code defined by a terminology system Fixed Value: (complex) | |
id | 0..0 | string | Unique id for inter-element referencing | |
extension | 0..0 | Extension | Additional content defined by implementations | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
version | 0..0 | string | Version of the system - if relevant | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: MR | |
display | 0..0 | string | Representation defined by the system | |
userSelected | 0..0 | boolean | If this coding was chosen directly by the user | |
text | 0..0 | string | Plain text representation of the concept | |
system | Σ | 1..1 | uri | Should indicate the assigning provider of the MRN. This is provider defined. Binding: Medical Record System (required) Example General: http://www.acme.com/identifiers/patient |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Populate if the identifier.value is reused by multiple providers (as is the case with EMIS identifiers) |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
reference | ΣC | 0..1 | string | Literal reference, Relative, internal or absolute URL |
type | Σ | 0..1 | uri | Type the reference refers to (e.g. "Patient") Binding: ResourceType (extensible): Aa resource (or, for logical models, the URI of the logical model). |
identifier | 0..1 | OrganisationCode | An identifier intended for computation | |
display | Σ | 0..1 | string | Text alternative for the resource |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Identifier.type | extensible | Fixed Value: MRhttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Identifier.system | required | MedicalRecordSystem (a valid code from Medical Record System)https://fhir.virtually.healthcare/ValueSet/MedicalRecordSystem from this IG | |
Identifier.assigner.type | extensible | ResourceTypehttp://hl7.org/fhir/ValueSet/resource-types from the FHIR Standard |
This structure is derived from Identifier
Other representations of profile: CSV, Excel, Schematron