Query for Existing Data for Mobile (QEDm)
3.0.1-current - ci-build
Query for Existing Data for Mobile (QEDm), published by IHE Patient Care Coordination Technical Committee. This guide is not an authorized publication; it is the continuous build for version 3.0.1-current built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/IHE/PCC.QEDm/ and changes regularly. See the Directory of published versions
This page provides a list of the FHIR artifacts defined as part of this implementation guide.
The following artifacts define the specific capabilities that different types of systems are expected to have in order to comply with this implementation guide. Systems conforming to this implementation guide are expected to declare conformance to one or more of the following capability statements.
IHE QEDm Clinical Data Consumer Actor |
CapabilityStatement for Clinical Data Consumer Actor The Clinical Data Consumer in this profile sends FHIR-based queries to the Clinical Data Source for one or more fine-grained data elements (FHIR resources) defined by the options listed in Section 8.2 QEDm Actor Options. Rendering or further processing of the data is not defined by this profile. |
IHE QEDm Clinical Data Source Actor |
CapabilityStatement for Clinical Data Source Actor. The Clinical Data Source in this profile responds to FHIR-based queries for one or more fine-grained data elements (FHIR resources) defined by the options listed in Section 8.2 QEDm Actor Options. |
These define constraints on FHIR resources for systems conforming to this implementation guide.
Audit Event for QEDm Query at Consumer |
Defines constraints on the AuditEvent (AuditMessage) Resource for a Clinical Data Consumer to record when it performs a Clinical Data Query PCC-44.
|
Audit Event for QEDm Query at Source |
Defines constraints on the AuditEvent (AuditMessage) Resource when a Clinical Data Source responds to a Clinical Data Query PCC-44.
|
These are example instances that show what data produced and consumed by systems conforming with this implementation guide might look like.
Audit Example of PCC-44 at Consumer |
Audit Event for QEDm Query Transaction by the Patient Identifier Cross-reference Consumer where the Query was executed with a GET as follows:
|
Audit Example of PCC-44 at Source |
Audit Event for QEDm Query Transaction by the Patient Identifier Cross-reference Source where the Query was executed with a GET as follows:
|
Dummy Device example |
Dummy Device example for completeness sake. No actual use of this resource other than an example target |
Dummy DocumentReference example |
Dummy DocumentReference example for completeness sake. No actual use of this resource other than an example target |
Example Encounter |
holding typical values |
Example Patient |
The patient from which all the example relate |
Example of a search set bundle |
Search on Weight Observations with reverse include requesting Provenance. This is returning two weight Observations and one Provenance. |
Example of an IHE QEDm blood pressure R4 observation, minimal |
holding typical values |
Example of an QEDm bodyWeight R4 observation |
Sample for demonstration purposes of a common weight Observation
|
Example of an QEDm bodyWeight R4 observation |
Sample for demonstration purposes of a common weight Observation
|
Provenance of extracted resources |
Sample of a Provenance of a set of target FHIR Resource elements derived from a DocumentReference |