Lithuanian Vital Signs Implementation Guide
0.0.1 - ci-build
Lithuanian Vital Signs Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-vitalsigns/ and changes regularly. See the Directory of published versions
Contents:
This page provides a list of the FHIR artifacts defined as part of this implementation guide.
Observation, Device, and BodyStructure profiles for vital signs
| Blood Pressure Panel |
Blood Pressure Panel; a grouping of systolic, diastolic, and mean arterial blood pressure components. |
| Body Height |
The measurement in centimeters or feet and inches from the top of the head to the heel, usually while standing. |
| Body Mass Index |
Body Mass Index (BMI) is a measure of body fat based on height and weight. |
| Body Weight |
The measured mass of an individual's body. |
| Heart Rate |
The number of heart beats in a minute. |
| Head Circumference |
Head Occipital-frontal circumference by Tape measure. The measurement in centimeters or inches around the largest part of the head. |
| Waist Circumference |
Waist circumference by Tape measure. The measurement in centimeters or inches around the narrowest part of the waist. |
| Device for Blood Pressure Measurement |
Device used to measure blood pressure. |
| Device for Body Height Measurement |
Device used to measure body height. |
| Body Weight Measurement Device |
Device used to measure body weight. |
| Device for Heart Rate Measurement |
Device used to measure heart rate. |
| Body Structure for Blood Pressure |
Body Structure profile to describe where on the body a blood pressure measurement was taken. |
Extensions for vital signs context
| Associated Situation Extension |
Situations that may affect the measurement or assessment. |
| Body Position Extension |
The position of the body when the observation was done, e.g. standing, sitting. To be used only when the body position in not precoordinated in the observation code. |
| Exercise Association Extension |
The exercise state associated with the measurement. |
| Measurement Setting Extension |
The location or setting the subject was in when the measurement was obtained. For example, home, clinic, hospital. etc. |
| Sleep Status Extension |
The state of wakefulness during the measurement. |
ValueSets and CodeSystems for vital signs
| Blood Pressure Cuff Size |
SNOMED CT code system values that describe the size of blood pressure cuff in use. |
| BP Panel observation codes |
This value set defines the set of LOINC codes considered to be appropriate for representing an arterial systolic and diastolic BP panel of vital signs measurements in Observation.component.code. |
| Blood Pressure Panel observation codes (SNOMED CT) |
SNOMED CT codes for blood pressure panel vital sign measurements in Observation.code. |
| BP Systolic observation codes |
This value set defines the set of LOINC codes considered to be appropriate for representing an arterial systolic BP vital sign measurement in Observation.component.code. |
| BP Systolic observation codes (SNOMED CT) |
SNOMED CT codes for systolic blood pressure component in Observation.component.code. |
| BP Diastolic observation codes |
This value set defines the set of LOINC codes considered to be appropriate for representing an arterial diastolic BP vital sign measurement in Observation.component.code. |
| BP Diastolic observation codes (SNOMED CT) |
SNOMED CT codes for diastolic blood pressure component in Observation.component.code. |
| BP Mean observation codes (LOINC) |
LOINC codes for mean arterial blood pressure component in Observation.component.code. |
| BP Mean observation codes (SNOMED CT) |
SNOMED CT codes for mean arterial blood pressure component in Observation.component.code. |
| Blood Pressure Units |
UCUM units for recording blood pressure. |
| Blood Pressure Measurement Body Location |
SELECT SNOMED CT code system values that describe the location on the body where the blood pressure was measured. |
| Blood Pressure Measurement Method |
SNOMED CT code system values that describe how a blood pressure was measured. |
| Heart Rate observation codes |
This value set defines the set of LOINC codes considered to be appropriate for representing heart rate vital sign measurements in Observation.code. |
| Heart Rate observation codes (SNOMED CT) |
SNOMED CT codes for heart rate vital sign measurements in Observation.code. |
| Heart Rate Measurement Body Location |
SNOMED CT code system values that describe where on the body the heart rate was measured. |
| Heart Rate Measurement Method |
SNOMED CT code system values that describe how the heart rate was measured. |
| Body Height observation codes |
This value set defines the set of LOINC codes considered to be appropriate for representing body height (including body length) vital sign measurements in Observation.code. |
| Body Height observation codes (SNOMED CT) |
SNOMED CT codes for body height vital sign measurements in Observation.code. |
| Body Weight observation codes |
This value set defines the set of LOINC codes considered to be appropriate for representing body weight vital sign measurements in Observation.code. |
| Body Weight observation codes (SNOMED CT) |
SNOMED CT codes for body weight vital sign measurements in Observation.code. |
| Body Mass Index observation codes (LOINC) |
LOINC codes for body mass index vital sign measurements in Observation.code. |
| Body Mass Index observation codes (SNOMED CT) |
SNOMED CT codes for body mass index vital sign measurements in Observation.code. |
| BMI Units |
UCUM units for recording BMI |
| Body Length Units |
UCUM units for recording body length measures such as height and head circumference |
| Body Weight Associated Situation |
SNOMED CT code system values and temporary code system values that describe situations to be considered when interpreting measured values. |
| Rate Units |
UCUM rate units for recording vital signs including heart and respiratory rate. |
| Height Length Measurement Method |
SNOMED CT code system values that describe how the height/length was measured. |
| Head Circumference observation codes (LOINC) |
LOINC codes for head circumference vital sign measurements in Observation.code. |
| Head Circumference observation codes (SNOMED CT) |
SNOMED CT codes for head circumference vital sign measurements in Observation.code. |
| Waist Circumference observation codes (LOINC) |
LOINC codes for waist circumference vital sign measurements in Observation.code. |
| Waist Circumference observation codes (SNOMED CT) |
SNOMED CT codes for waist circumference vital sign measurements in Observation.code. |
| WaistCircumference Result Interpretation value set |
that describes interpretations associated with a measured value. |
| Device Types for Blood Pressure Measurement |
SNOMED CT code system values that describe the isntrument used to measure the blood pressure. |
| Device Types for Height Length Measurement |
SNOMED CT code system values that describe the instrument used to measure the body height/length. |
| Device Types for Weight Measurement |
SNOMED CT code system values that describe the instrument used to measure the body weight. |
| Device Types for Heart Rate Measurement |
SELECT SNOMED CT code system values that describe the instrument used to measure the heart rate. |
| Body Position used in Vital Signs Measurements |
SNOMED CT code system values the position in which the individual was in during a measurement. |
| Sleep Status in Vital Signs Measurements |
SNOMED CT code system values that contains terms used to indicate the state of wakefulness during measurement. |
| Exertion Phase |
SNOMED CT code system values that contains terms for exercise associated with a measurement. |
| Measurement Environment |
Environment that indicate the surroundings the individual was in during the measurement (i.e. home, clinic, hospital, etc.). |
| Numeric Result Interpretation value set |
The HL7 V3:ObservationInterpretation code set (OID: 2.16.840.1.113883.5.83) that describes interpretations associated with a measured value. |
| Numeric Result Interpretation without panic values, value set |
The HL7 V3:ObservationInterpretation code set (OID: 2.16.840.1.113883.5.83) that describes interpretations associated with a measured value, constrained to terms that are not those associated with 'panic' terms. |
| SNOMED CT Vital Signs Extension |
A set of codes that are defined in the Vital Signs extension to the SNOMED CT code system. To be used until they are adopted by SNOMED CT. |
Example instances for vital signs and devices
| Patient: John Doe (example) |
An example Patient. |
| Observation: Blood Pressure (example) |
Example observation representing a patient's blood pressure measurement. |
| Observation: Heart Rate (example) |
Example observation representing the patient's heart rate measured at rest. |
| Observation: Body Height (example) |
Example observation representing the patient's body height measured in centimeters. |
| Observation: Body Weight (example) |
Example observation representing the patient's body weight measured in kilograms. |
| Observation: Body Mass Index (example) |
An example BMI measurement for a patient. |
| Observation: Head Circumference (example) |
Measured head circumference using a tape measure. |
| Observation: Waist Circumference (example) |
Measured waist circumference using a tape measure. |
| Device: Blood Pressure Measurement (example) |
Automated digital blood pressure monitor with adult cuff. |
| Device: Body Height Measurement (example) |
A stadiometer used to measure the patient's height. |
| Device: Body Weight Measurement (example) |
A weighing scale used to measure the patient's body weight. |
| Device: Heart Rate Measurement (example) |
An automated digital heart rate monitor used for the measurement. |
| BodyStructure: Blood Pressure Measurement Site (example) |
Example showing where on the body a blood pressure measurement was taken. |