Lithuanian Vital Signs Implementation Guide
0.0.1 - ci-build Lithuania flag

Lithuanian Vital Signs Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-vitalsigns/ and changes regularly. See the Directory of published versions

: Body Length Units

Active as of 2026-04-10

Raw xml | Download


<ValueSet xmlns="http://hl7.org/fhir">
  <id value="body-length-unit"/>
  <meta>
    <lastUpdated value="2025-10-26T17:42:56.640+00:00"/>
    <profile
             value="http://hl7.org/fhir/StructureDefinition/shareablevalueset|5.0.0"/>
  </meta>
  <language value="en"/>
  <text>
    <status value="generated"/>
    <div xml:lang="en" lang="en"><hr/><p><b>English</b></p><hr/><p class="res-header-id"><b>Generated Narrative: ValueSet body-length-unit</b></p><a name="body-length-unit"> </a><a name="hcbody-length-unit"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Last updated: 2025-10-26 17:42:56+0000; Language: en</p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/R5/shareablevalueset.html">Shareable ValueSet</a> version: 5.0.0</p></div><ul><li>Include these codes as defined in <a href="http://unitsofmeasure.org"><code>http://unitsofmeasure.org</code></a><span title="Version is not explicitly stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td>cm</td><td style="color: #cccccc">cm</td></tr><tr><td>[in_i]</td><td style="color: #cccccc">[in_i]</td></tr></table></li></ul></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/valueset-extensible">
    <valueBoolean value="false"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="oo"/>
  </extension>
  <url value="https://tx.hl7.lt/fhir/ValueSet/body-length-unit"/>
  <identifier>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:2.16.840.1.113883.4.642.3.958"/>
  </identifier>
  <identifier>
    <use value="old"/>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:2.16.840.1.113883.4.642.3.873"/>
  </identifier>
  <version value="6.0.0"/>
  <name value="BodyLengthUnit"/>
  <title value="Body Length Units"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2026-04-10T05:24:00+00:00"/>
  <publisher value="Lithuanian Medical Library"/>
  <contact>
    <name value="Lithuanian Medical Library"/>
    <telecom>
      <system value="url"/>
      <value value="https://medicinosnk.lt"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="info@medicinosnk.lt"/>
    </telecom>
  </contact>
  <description
               value="UCUM units for recording body length measures such as height and head circumference"/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="LT"/>
    </coding>
  </jurisdiction>
  <copyright
             value="UCUM is Copyright © 1999-2013 Regenstrief Institute, Inc. and The UCUM Organization, Indianapolis, IN. All rights reserved. See http://unitsofmeasure.org/trac//wiki/TermsOfUse for details"/>
  <compose>
    <include>
      <system value="http://unitsofmeasure.org"/>
      <concept>
        <code value="cm"/>
      </concept>
      <concept>
        <code value="[in_i]"/>
      </concept>
    </include>
  </compose>
</ValueSet>