Personal Health Device Implementation Guide
3.0.0-ballot - STU 3 Ballot Global (Whole world)

Personal Health Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

: Phd Device Metric for Pulse Rate with UCUM

Page standards status: Informative

Raw xml | Download


<DeviceMetric xmlns="http://hl7.org/fhir">
  <id value="pulse-rate-ucum-devicemetric-example"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDeviceMetric"/>
  </meta>
  <language value="en"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: DeviceMetric pulse-rate-ucum-devicemetric-example</b></p><a name="pulse-rate-ucum-devicemetric-example"> </a><a name="hcpulse-rate-ucum-devicemetric-example"> </a><div style="display: inline-block; background-color: #fbffeb; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-PhdDeviceMetric.html">PhdDeviceMetric</a></p></div><p><b>status</b>: Active</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/metric-category measurement}">Measurement</span></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 149530}">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>device</b>: <a href="Device-phd-74E8FFFEFF051C00.001C05FFE874.html">Device: identifier = IEEE 11073 System Identifier: 74-E8-FF-FE-FF-05-1C-00,Bluetooth MAC address: Bluetooth Address as a device identifier#00-1C-05-FF-E8-74; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = Simple PHD,Pulse Oximeter</a></p><p><b>unit</b>: <span title="Codes:{http://unitsofmeasure.org /min}, {urn:iso:std:iso:11073:10101 264864}">beats per minute</span></p></div>
  </text>
  <status value="active"/>
  <category>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/metric-category"/>
      <code value="measurement"/>
    </coding>
  </category>
  <type>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="149530"/>
      <display value="MDC_PULS_OXIM_PULS_RATE"/>
    </coding>
  </type>
  <device>🔗 
    <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
  </device>
  <unit>
    <coding>
      <system value="http://unitsofmeasure.org"/>
      <code value="/min"/>
    </coding>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="264864"/>
      <display value="MDC_DIM_BEAT_PER_MIN"/>
    </coding>
    <text value="beats per minute"/>
  </unit>
</DeviceMetric>