Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 1.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
{
"resourceType" : "Observation",
"id" : "rtsa-1234",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdRtsaObservation"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation rtsa-1234</b></p><a name=\"rtsa-1234\"> </a><a name=\"hcrtsa-1234\"> </a><a name=\"rtsa-1234-en-US\"> </a><p><b>Observation Gateway Device</b>: <a href=\"Device-phg-ecde3d4e58532d31.000000000000.html\">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address,Ethernet MAC address; type = MDC_MOC_VMS_MDS_AHD</a></p><p><b>Coincident Timestamp Reference</b>: <a href=\"Observation-coin-example-1.html\">Observation MDC_ATTR_TIME_ABS</a></p><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}\">PHD generated Observation</span></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 150452}\">MDC_PULS_OXIM_PLETH: Pleth Wave</span></p><p><b>subject</b>: <a href=\"Patient-patientExample-1.html\">Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-08-02 02:25:24-0400</p><p><b>performer</b>: <a href=\"Patient-patientExample-1.html\">Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>value</b>: Origin: -3.4 1 , Factor: 3.0 , Dimensions: 1 , Data: 123 110 97 99 112 118 </p><p><b>device</b>: <a href=\"Device-phd-00601900010E9234.F45EABA80832.html\">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Diabetes Care; serialNumber = 20130200002A; modelNumber = Gluc-23; type = MDC_MOC_VMS_MDS_SIMP</a></p></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice",
"valueReference" : {
🔗 "reference" : "Device/phg-ecde3d4e58532d31.000000000000"
}
},
{
"url" : "http://hl7.org/fhir/uv/phd/StructureDefinition/CoincidentTimeStampReference",
"valueReference" : {
🔗 "reference" : "Observation/coin-example-1"
}
}
],
"status" : "final",
"category" : [
{
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories",
"code" : "phd-observation"
}
]
}
],
"code" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "150452"
}
],
"text" : "MDC_PULS_OXIM_PLETH: Pleth Wave"
},
"subject" : {
🔗 "reference" : "Patient/patientExample-1"
},
"effectiveDateTime" : "2018-08-02T02:25:24-04:00",
"performer" : [
{
🔗 "reference" : "Patient/patientExample-1"
}
],
"valueSampledData" : {
"origin" : {
"value" : -3.4,
"system" : "http://unitsofmeasure.org",
"code" : "1"
},
"period" : 2.000,
"factor" : 3.0,
"dimensions" : 1,
"data" : "123 110 97 99 112 118"
},
"device" : {
🔗 "reference" : "Device/phd-00601900010E9234.F45EABA80832"
}
}