Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 1.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

Example Observation: Example of a numeric.

This example shows a basic numeric observation. It does have a single component element as the measurement also contained a Supplemental Information attribute indicating the measurement is a SPOT (stable average).

Note there is no logical id in this resource as this resource is being uploaded to the server in a conditional create operation. The server will use the identifier to check that no other Observation resource exists on the server with the same identifier. If there is not such resource present, the server will create the logical id and return it to the sender in the response. Pulse oximeters reporting a SPOT measurement have a time stamp thus there is a reference to the coincident time stamp.

The referenced resources are assumed to have been uploaded to the server before - Patient, PHD, PHG and coincident timestamp.

Generated Narrative: Observation numeric-spotnumeric

Observation Gateway Device: Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address,Ethernet MAC address; type = MDC_MOC_VMS_MDS_AHD

Coincident Timestamp Reference: Observation MDC_ATTR_TIME_ABS

Numeric Accuracy: 0.1 /min (Details: UCUM code/min = '/min')

identifier: 74E8FFFEFF051C00-sisansarahId-urn:oid:1.2.3.4.5.6.7.8.10-149530-20181113175902.00-48.0-2720-150588

status: Final

category: Vital Signs, PHD generated Observation

code: MDC_PULS_OXIM_PULS_RATE

subject: Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)

effective: 2018-11-13 17:59:02-0500

performer: Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)

value: 48.0 {beat}/min} (Details: UCUM code/min = '/min')

device: Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP

component

code: MDC_ATTR_SUPPLEMENTAL_TYPES

value: MDC_MODALITY_SPOT

component

code: MDC_ATTR_NU_ACCUR_MSMT: Measurement accuracy

value: 0.1 /min (Details: UCUM code/min = '/min')