Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 1.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <https://loinc.org/rdf/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Observation ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "numeric-spotnumeric"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation numeric-spotnumeric</b></p><a name=\"numeric-spotnumeric\"> </a><a name=\"hcnumeric-spotnumeric\"> </a><a name=\"numeric-spotnumeric-en-US\"> </a><p><b>Observation Gateway Device</b>: <a href=\"Device-phg-ecde3d4e58532d31.000000000000.html\">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address,Ethernet MAC address; type = MDC_MOC_VMS_MDS_AHD</a></p><p><b>Coincident Timestamp Reference</b>: <a href=\"Observation-coin-20181119202022.html\">Observation MDC_ATTR_TIME_ABS</a></p><p><b>Numeric Accuracy</b>: 0.1 /min<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code/min = '/min')</span></p><p><b>identifier</b>: 74E8FFFEFF051C00-sisansarahId-urn:oid:1.2.3.4.5.6.7.8.10-149530-20181113175902.00-48.0-2720-150588</p><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}\">Vital Signs</span>, <span title=\"Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories phd-observation}\">PHD generated Observation</span></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 149530}, {http://loinc.org 8867-4}\">MDC_PULS_OXIM_PULS_RATE</span></p><p><b>subject</b>: <a href=\"Patient-patientExample-1.html\">Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>effective</b>: 2018-11-13 17:59:02-0500</p><p><b>performer</b>: <a href=\"Patient-patientExample-1.html\">Sisansarah Lorianthah Piggy (no stated gender), DoB Unknown ( Medical record number)</a></p><p><b>value</b>: 48.0 {beat}/min}<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code/min = '/min')</span></p><p><b>device</b>: <a href=\"Device-phd-74E8FFFEFF051C00.001C05FFE874.html\">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = Nonin_Medical_Inc.; serialNumber = 501900083; modelNumber = Model 3230; type = MDC_MOC_VMS_MDS_SIMP</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 68193}\">MDC_ATTR_SUPPLEMENTAL_TYPES</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 150588}\">MDC_MODALITY_SPOT</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 67914}\">MDC_ATTR_NU_ACCUR_MSMT: Measurement accuracy</span></p><p><b>value</b>: 0.1 /min<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code/min = '/min')</span></p></blockquote></div>"
] ; #
fhir:extension ( [
fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice"^^xsd:anyURI ] ;
fhir:value [
a fhir:Reference ;
fhir:reference [ fhir:v "Device/phg-ecde3d4e58532d31.000000000000" ] ]
] [
fhir:url [ fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/CoincidentTimeStampReference"^^xsd:anyURI ] ;
fhir:value [
a fhir:Reference ;
fhir:reference [ fhir:v "Observation/coin-20181119202022" ] ]
] [
fhir:url [ fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/Accuracy"^^xsd:anyURI ] ;
fhir:value [
a fhir:Quantity ;
fhir:value [ fhir:v "0.1"^^xsd:decimal ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "/min" ] ]
] ) ; #
fhir:identifier ( [
fhir:value [ fhir:v "74E8FFFEFF051C00-sisansarahId-urn:oid:1.2.3.4.5.6.7.8.10-149530-20181113175902.00-48.0-2720-150588" ]
] ) ; #
fhir:status [ fhir:v "final"] ; #
fhir:category ( [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/observation-category"^^xsd:anyURI ] ;
fhir:code [ fhir:v "vital-signs" ] ] ) ;
fhir:text [ fhir:v "Vital Signs" ]
] [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/PhdObservationCategories"^^xsd:anyURI ] ;
fhir:code [ fhir:v "phd-observation" ] ] )
] ) ; #
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "149530" ] ] [
a loinc:8867-4 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "8867-4" ] ] ) ;
fhir:text [ fhir:v "MDC_PULS_OXIM_PULS_RATE" ]
] ; #
fhir:subject [
fhir:reference [ fhir:v "Patient/patientExample-1" ]
] ; #
fhir:effective [ fhir:v "2018-11-13T17:59:02-05:00"^^xsd:dateTime] ; #
fhir:performer ( [
fhir:reference [ fhir:v "Patient/patientExample-1" ]
] ) ; #
fhir:value [
a fhir:Quantity ;
fhir:value [ fhir:v "48.0"^^xsd:decimal ] ;
fhir:unit [ fhir:v "{beat}/min}" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "/min" ]
] ; #
fhir:device [
fhir:reference [ fhir:v "Device/phd-74E8FFFEFF051C00.001C05FFE874" ]
] ; #
fhir:component ( [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "68193" ] ] ) ;
fhir:text [ fhir:v "MDC_ATTR_SUPPLEMENTAL_TYPES" ] ] ;
fhir:value [
a fhir:CodeableConcept ;
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "150588" ] ] ) ;
fhir:text [ fhir:v "MDC_MODALITY_SPOT" ] ]
] [
fhir:code [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "67914" ] ] ) ;
fhir:text [ fhir:v "MDC_ATTR_NU_ACCUR_MSMT: Measurement accuracy" ] ] ;
fhir:value [
a fhir:Quantity ;
fhir:value [ fhir:v "0.1"^^xsd:decimal ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "/min" ] ]
] ) . #