At-Home In-Vitro Test Report, published by HL7 International / Orders and Observations. This guide is not an authorized publication; it is the continuous build for version 1.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/home-lab-report/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Observation-at-home-in-vitro-test-result-covid | Version: 1.1.0 | |||
Active as of 2024-08-08 | Computable Name: ObservationAtHomeInVitroTestResultCovid | |||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.32.42.10 |
This profile constrains the Observation - At-Home In-Vitro Test Result profile to COVID-19 At-Home In-Vitro Tests.
This is an example of a profile that is based on a framework profile and futher constrained to meet the requirements of the COVID-19 use case. It is based on the Observation - At-Home In-Vitro Test Result profile.
It constrains the following elements to COVID-19 specific value sets:
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from ObservationAtHomeInVitroTestResult
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | ObservationAtHomeInVitroTestResult | |||
code | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. | |
value[x] | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. | |
specimen | 1..1 | Reference(Specimen - At-Home In-Vitro Test - COVID-19) | The Specimen SHALL be from at-home COVID-19 sample. | |
device | 1..1 | Reference(Device - At-Home In-Vitro Test) | The referenced device is an at-home COVID-19 test device. | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | ObservationAtHomeInVitroTestResult | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present |
id | SΣ | 1..1 | id | Logical id of this artifact |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Extension-at-home-in-vitro-test-proctored-info | 0..1 | (Complex) | Extension - At-Home In-Vitro Test Proctored Information URL: http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Extension-at-home-in-vitro-test-proctored-info | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | At-Home Test result status final. V2: OBR-25, OBX-11 Binding: ObservationStatus (required): Codes providing the status of an observation. Fixed Value: final |
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:us-core | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: US Core Clinical Result Observation Category (required): Note that other codes are permitted, see Required Bindings When Slicing by Value Sets Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: laboratory | |
code | SΣ | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. Binding: US Core Laboratory Test Codes (extensible): Laboratory LOINC Codes |
subject | SΣ | 1..1 | Reference(Patient - At Home In Vitro Test) | (USCDI) Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | dateTime | At-Home Test date of interpretation/result date. The effectiveTime SHALL be precise to at least the minute and SHALL include a time zone offset. NOTE: For multiplex tests, this field must match across all results. V2: OBX-7.1, OBX-19 us-core-1: Datetime must be at least to day. |
issued | SΣ | 0..1 | instant | At-Home Test result date released - when test item is done (in the at-home setting will mostly be the same as the Observation.effective[x], could be different when a proctor is involved - when the proctor releases the result). V2: OBR-22.1 |
performer | SΣ | 0..* | Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile | US Core CareTeam Profile | Patient - At Home In Vitro Test | US Core RelatedPerson Profile) | If the performer is not the patient being tested, specify the person performing the test. |
value[x] | SΣC | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. us-core-3: SHALL use UCUM for coded quantity units. us-core-4: SHOULD use Snomed CT for coded Results |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
specimen | S | 1..1 | Reference(Specimen - At-Home In-Vitro Test - COVID-19) | The Specimen SHALL be from at-home COVID-19 sample. |
device | S | 1..1 | Reference(Device - At-Home In-Vitro Test) | The referenced device is an at-home COVID-19 test device. |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | Fixed Value: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:us-core | required | Pattern: laboratoryhttp://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category | |
Observation.code | extensible | USCoreLaboratoryTestCodeshttp://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | ObservationAtHomeInVitroTestResult | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present | ||||
id | SΣ | 1..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Extension-at-home-in-vitro-test-proctored-info | 0..1 | (Complex) | Extension - At-Home In-Vitro Test Proctored Information URL: http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Extension-at-home-in-vitro-test-proctored-info | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | At-Home Test result status final. V2: OBR-25, OBX-11 Binding: ObservationStatus (required): Codes providing the status of an observation. Fixed Value: final | ||||
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:us-core | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: US Core Clinical Result Observation Category (required): Note that other codes are permitted, see Required Bindings When Slicing by Value Sets Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: laboratory | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. Binding: US Core Laboratory Test Codes (extensible): Laboratory LOINC Codes | ||||
subject | SΣ | 1..1 | Reference(Patient - At Home In Vitro Test) | (USCDI) Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | dateTime S | At-Home Test date of interpretation/result date. The effectiveTime SHALL be precise to at least the minute and SHALL include a time zone offset. NOTE: For multiplex tests, this field must match across all results. V2: OBX-7.1, OBX-19 us-core-1: Datetime must be at least to day. | ||||
issued | SΣ | 0..1 | instant | At-Home Test result date released - when test item is done (in the at-home setting will mostly be the same as the Observation.effective[x], could be different when a proctor is involved - when the proctor releases the result). V2: OBR-22.1 | ||||
performer | SΣ | 0..* | Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile | US Core CareTeam Profile | Patient - At Home In Vitro Test | US Core RelatedPerson Profile) | If the performer is not the patient being tested, specify the person performing the test. | ||||
value[x] | SΣC | 1..1 | CodeableConcept S | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. us-core-3: SHALL use UCUM for coded quantity units. us-core-4: SHOULD use Snomed CT for coded Results | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | S | 1..1 | Reference(Specimen - At-Home In-Vitro Test - COVID-19) | The Specimen SHALL be from at-home COVID-19 sample. | ||||
device | S | 1..1 | Reference(Device - At-Home In-Vitro Test) | The referenced device is an at-home COVID-19 test device. | ||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation - At-Home In-Vitro Test Result) | Multiplex Assay tests that serve as a single test to diagnose infection caused by multiple viruses (e.g. CDC Flu SC2 Multiplex Assay for SARS-CoV-2, influenza A, and/or influenza B viruses) should be recorded using multiple Observation.hasMember elements. | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
component | Σ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | Fixed Value: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:us-core | required | Pattern: laboratoryhttp://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category | ||||
Observation.code | extensible | USCoreLaboratoryTestCodeshttp://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
This structure is derived from ObservationAtHomeInVitroTestResult
Differential View
This structure is derived from ObservationAtHomeInVitroTestResult
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | ObservationAtHomeInVitroTestResult | |||
code | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. | |
value[x] | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. | |
specimen | 1..1 | Reference(Specimen - At-Home In-Vitro Test - COVID-19) | The Specimen SHALL be from at-home COVID-19 sample. | |
device | 1..1 | Reference(Device - At-Home In-Vitro Test) | The referenced device is an at-home COVID-19 test device. | |
Documentation for this format |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | ObservationAtHomeInVitroTestResult | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present |
id | SΣ | 1..1 | id | Logical id of this artifact |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Extension-at-home-in-vitro-test-proctored-info | 0..1 | (Complex) | Extension - At-Home In-Vitro Test Proctored Information URL: http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Extension-at-home-in-vitro-test-proctored-info | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | At-Home Test result status final. V2: OBR-25, OBX-11 Binding: ObservationStatus (required): Codes providing the status of an observation. Fixed Value: final |
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:us-core | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: US Core Clinical Result Observation Category (required): Note that other codes are permitted, see Required Bindings When Slicing by Value Sets Required Pattern: At least the following |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: laboratory | |
code | SΣ | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. Binding: US Core Laboratory Test Codes (extensible): Laboratory LOINC Codes |
subject | SΣ | 1..1 | Reference(Patient - At Home In Vitro Test) | (USCDI) Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | dateTime | At-Home Test date of interpretation/result date. The effectiveTime SHALL be precise to at least the minute and SHALL include a time zone offset. NOTE: For multiplex tests, this field must match across all results. V2: OBX-7.1, OBX-19 us-core-1: Datetime must be at least to day. |
issued | SΣ | 0..1 | instant | At-Home Test result date released - when test item is done (in the at-home setting will mostly be the same as the Observation.effective[x], could be different when a proctor is involved - when the proctor releases the result). V2: OBR-22.1 |
performer | SΣ | 0..* | Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile | US Core CareTeam Profile | Patient - At Home In Vitro Test | US Core RelatedPerson Profile) | If the performer is not the patient being tested, specify the person performing the test. |
value[x] | SΣC | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. us-core-3: SHALL use UCUM for coded quantity units. us-core-4: SHOULD use Snomed CT for coded Results |
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
specimen | S | 1..1 | Reference(Specimen - At-Home In-Vitro Test - COVID-19) | The Specimen SHALL be from at-home COVID-19 sample. |
device | S | 1..1 | Reference(Device - At-Home In-Vitro Test) | The referenced device is an at-home COVID-19 test device. |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Observation.status | required | Fixed Value: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:us-core | required | Pattern: laboratoryhttp://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category | |
Observation.code | extensible | USCoreLaboratoryTestCodeshttp://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | ObservationAtHomeInVitroTestResult | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present | ||||
id | SΣ | 1..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Extension-at-home-in-vitro-test-proctored-info | 0..1 | (Complex) | Extension - At-Home In-Vitro Test Proctored Information URL: http://hl7.org/fhir/us/home-lab-report/StructureDefinition/Extension-at-home-in-vitro-test-proctored-info | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | At-Home Test result status final. V2: OBR-25, OBX-11 Binding: ObservationStatus (required): Codes providing the status of an observation. Fixed Value: final | ||||
Slices for category | S | 1..* | CodeableConcept | (USCDI) Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:us-core | S | 1..1 | CodeableConcept | (USCDI) Classification of type of observation Binding: US Core Clinical Result Observation Category (required): Note that other codes are permitted, see Required Bindings When Slicing by Value Sets Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: laboratory | |||||
display | 0..1 | string | Representation defined by the system | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
code | SΣ | 1..1 | CodeableConcept | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. Binding: US Core Laboratory Test Codes (extensible): Laboratory LOINC Codes | ||||
subject | SΣ | 1..1 | Reference(Patient - At Home In Vitro Test) | (USCDI) Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | dateTime S | At-Home Test date of interpretation/result date. The effectiveTime SHALL be precise to at least the minute and SHALL include a time zone offset. NOTE: For multiplex tests, this field must match across all results. V2: OBX-7.1, OBX-19 us-core-1: Datetime must be at least to day. | ||||
issued | SΣ | 0..1 | instant | At-Home Test result date released - when test item is done (in the at-home setting will mostly be the same as the Observation.effective[x], could be different when a proctor is involved - when the proctor releases the result). V2: OBR-22.1 | ||||
performer | SΣ | 0..* | Reference(US Core Practitioner Profile | US Core PractitionerRole Profile | US Core Organization Profile | US Core CareTeam Profile | Patient - At Home In Vitro Test | US Core RelatedPerson Profile) | If the performer is not the patient being tested, specify the person performing the test. | ||||
value[x] | SΣC | 1..1 | CodeableConcept S | Consult LIVD: https://www.cdc.gov/csels/dls/livd-codes.html to obtain the values to be used for the COVID-19 use case. us-core-3: SHALL use UCUM for coded quantity units. us-core-4: SHOULD use Snomed CT for coded Results | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | (USCDI) Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | S | 1..1 | Reference(Specimen - At-Home In-Vitro Test - COVID-19) | The Specimen SHALL be from at-home COVID-19 sample. | ||||
device | S | 1..1 | Reference(Device - At-Home In-Vitro Test) | The referenced device is an at-home COVID-19 test device. | ||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(Observation - At-Home In-Vitro Test Result) | Multiplex Assay tests that serve as a single test to diagnose infection caused by multiple viruses (e.g. CDC Flu SC2 Multiplex Assay for SARS-CoV-2, influenza A, and/or influenza B viruses) should be recorded using multiple Observation.hasMember elements. | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | ||||
component | Σ | 0..* | BackboneElement | Component results | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | ||||
value[x] | Σ | 0..1 | Actual component result | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet / Code | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.status | required | Fixed Value: finalhttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:us-core | required | Pattern: laboratoryhttp://hl7.org/fhir/us/core/ValueSet/us-core-clinical-result-observation-category | ||||
Observation.code | extensible | USCoreLaboratoryTestCodeshttp://hl7.org/fhir/us/core/ValueSet/us-core-laboratory-test-codes | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | example | LOINCCodes (a valid code from LOINC)http://hl7.org/fhir/ValueSet/observation-codes from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
This structure is derived from ObservationAtHomeInVitroTestResult
Other representations of profile: CSV, Excel, Schematron