HL7 FHIR Implementation Guide: Profiles for Transfusion and Vaccination Adverse Event Detection and Reporting
1.0.1 - STU 1 Technical Correction United States of America flag

HL7 FHIR Implementation Guide: Profiles for Transfusion and Vaccination Adverse Event Detection and Reporting, published by Biomedical Research & Regulation WG. This is not an authorized publication; it is the continuous build for version 1.0.1). This version is based on the current content of https://github.com/HL7/fhir-icsr-ae-reporting/ and changes regularly. See the Directory of published versions

Relationship to US-Core

We have tried to have the FHIR profiles conform to the HL7 FHIR US Core Implementation Guide where applicable. Below is a summary of the differences between the profiles defined in this guide and the US-Core profiles:

Differences from IG-defined Profiles to US-Core

  • Patient: Added militaryStatus extension and made telecom Must Support
  • Practitioner: Added mustSupport to: telecom, address
  • PractitionerRole: Map from the US Core Provider Role (NUCC) value set to ICSR codes
  • Organization:
    • Added DepartmentName extension
    • Added mustSupport to: type, contact
    • Made mandatory: type, contact, address
    • Restricted telecom to 1 phone, 1 fax, and/or 1 email
  • RelatedPerson: Not in US-Core
  • MedicationAdministration: Not in US-Core
  • Medication: US-Core Medication profile is not referenced because it mandates RxNorm and we need to supply NDC codes for medication
  • Immunization:
    • Added ageAtVaccination extension
    • Added mustSupport to: manufacturer, location, lotNumber, expirationDate, site, route, doseQuantity
  • Procedure:
    • Added extension for BiologicallyDerivedProduct to usedReference
    • Added extension for quantity of used item
  • BiologicallyDerivedProduct: Not in US-Core
  • Vital Signs: Used without change for Weight, Height, LastMenstrualPeriod, AgeGroup
  • AdverseEvent: Not in US-Core