HL7 FHIR Implementation Guide: Profiles for Transfusion and Vaccination Adverse Event Detection and Reporting
1.0.1 - STU 1 Technical Correction United States of America flag

HL7 FHIR Implementation Guide: Profiles for Transfusion and Vaccination Adverse Event Detection and Reporting, published by Biomedical Research & Regulation WG. This is not an authorized publication; it is the continuous build for version 1.0.1). This version is based on the current content of https://github.com/HL7/fhir-icsr-ae-reporting/ and changes regularly. See the Directory of published versions

Example Composition: Sample ICSR Transfusion Report

Generated Narrative: Composition

Resource Composition "SampleTransfusionReport"

Profile: ICSR Composition

AdditionalDocumentInformation

url

availableFlag

value: false

ExpeditedReport

url

localCriteriaFlag

value: false

url

localCriteriaReportType

value: Non-Expedited AE (unknown#C53578)

FirstSenderType: Other (unknown#2)

CombinationProductReport: false

FirstReceiveDate: 2020-02-10 17:18:00-0500

MostRecentDate: 2020-02-10 17:18:00-0500

CaseIdentifier: id: US-IBM-aed059ac-ef25-6ded-cce2-a8912d6b76ee

PreviousCaseIdentifier: id: Other-case-identifier

ReportAmendment

url

amendmentType

value: 2 (unknown#2)

url

amendmentReason

value: Fixed some identifiers

identifier: id: US-IBM-94209fd1-9b0e-1adc-007a-4f5cecb8ce6a

status: final

type: Adverse event note (LOINC#85893-6)

category: Spontaneous report (unknown#1)

date: 2020-02-10 17:18:00-0500

author: PractitionerRole/SampleAuthorRole

title: ICSR Submission