DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions
Active as of 2024-09-23 |
<ConceptMap xmlns="http://hl7.org/fhir">
<id value="dicom-sr-measurement-report-to-fhir"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ConceptMap dicom-sr-measurement-report-to-fhir</b></p><a name="dicom-sr-measurement-report-to-fhir"> </a><a name="hcdicom-sr-measurement-report-to-fhir"> </a><a name="dicom-sr-measurement-report-to-fhir-en-US"> </a><p>Mapping from DICOM-SR-Measurement-Report to <a href="http://hl7.org/fhir/R5/bundle.html">Bundle</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Patient (Patient IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Patient[1]</td><td>The DICOM® SR Patient IE is mapped to a FHIR Patient resource</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Study (Study IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>ImagingStudy[1]</td><td>The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource</td></tr><tr><td>DICOM.Study (Study IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#related-to" title="related-to">is related to</a></td><td>ServiceRequest[1]</td><td>The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Equipment (Equipment IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Device[1]</td><td>The DICOM® SR Equipment IE may result in the creation of a new Device resource</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Document (Document IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#source-is-narrower-than-target" title="source-is-narrower-than-target">is narrower than</a></td><td>Observation[1]</td><td>Processing of the Document IE will result in the creation one or more new Observation resources</td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="ii"/>
</extension>
<url
value="http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir"/>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.40.39.18.7"/>
</identifier>
<version value="1.0.0"/>
<name value="DICOMSRMeasurementReportToFHIRMapping"/>
<title value="ConceptMap - DICOM SR Measurement Report to FHIR Mapping"/>
<status value="active"/>
<experimental value="false"/>
<date value="2024-09-23T13:34:34+00:00"/>
<publisher value="HL7 International / Imaging Integration"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<contact>
<name value="HL7 International / Imaging Integration"/>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<contact>
<name value="Jonathan Whitby"/>
<telecom>
<system value="email"/>
<value value="jonathan.whitby@mi.medical.canon"/>
</telecom>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<contact>
<name value="Christopher Lindop"/>
<telecom>
<system value="email"/>
<value value="Christopher.Lindop@ge.com"/>
</telecom>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/imagemgt"/>
</telecom>
</contact>
<description
value="Mapping between DICOM® SR Measurement Report and FHIR Resources"/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
</coding>
</jurisdiction>
<property>
<code value="references"/>
<type value="string"/>
</property>
<property>
<code value="imaging-measurement-group-map"/>
<type value="string"/>
</property>
<sourceScopeUri value="DICOM-SR-Measurement-Report"/>
<targetScopeUri value="Bundle"/>
<group>
<element>
<code value="DICOM.Patient"/>
<display value="Patient IE"/>
<target>
<code value="Patient[1]"/>
<display value="Patient[1]"/>
<relationship value="equivalent"/>
<comment
value="The DICOM® SR Patient IE is mapped to a FHIR Patient resource"/>
</target>
</element>
</group>
<group>
<element>
<code value="DICOM.Study"/>
<display value="Study IE"/>
<target>
<code value="ImagingStudy[1]"/>
<display value="ImagingStudy[1]"/>
<relationship value="equivalent"/>
<comment
value="The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource"/>
</target>
</element>
<element>
<code value="DICOM.Study"/>
<display value="Study IE"/>
<target>
<code value="ServiceRequest[1]"/>
<display value="ServiceRequest[1]"/>
<relationship value="related-to"/>
<comment
value="The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource"/>
</target>
</element>
</group>
<group>
<element>
<code value="DICOM.Equipment"/>
<display value="Equipment IE"/>
<target>
<code value="Device[1]"/>
<display value="Device[1]"/>
<relationship value="equivalent"/>
<comment
value="The DICOM® SR Equipment IE may result in the creation of a new Device resource"/>
</target>
</element>
</group>
<group>
<element>
<code value="DICOM.Document"/>
<display value="Document IE"/>
<target>
<code value="Observation[1]"/>
<display value="Observation[1]"/>
<relationship value="source-is-narrower-than-target"/>
<comment
value="Processing of the Document IE will result in the creation one or more new Observation resources"/>
<property>
<code value="imaging-measurement-group-map"/>
<valueString value="dicom-imaging-measurement-group-to-fhir"/>
</property>
<property>
<code value="references"/>
<valueString value="Observation.subject.reference=Patient[1].id"/>
</property>
<property>
<code value="references"/>
<valueString
value="Observation.partOf.reference=ImagingStudy[1].id"/>
</property>
<property>
<code value="references"/>
<valueString
value="Observation.basedOn.reference=ServiceRequest[1].id"/>
</property>
<property>
<code value="references"/>
<valueString value="Observation.device.reference=Device[1]"/>
</property>
</target>
</element>
</group>
</ConceptMap>