DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions
Active as of 2024-09-23 |
{
"resourceType" : "ConceptMap",
"id" : "dicom-sr-measurement-report-to-fhir",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap dicom-sr-measurement-report-to-fhir</b></p><a name=\"dicom-sr-measurement-report-to-fhir\"> </a><a name=\"hcdicom-sr-measurement-report-to-fhir\"> </a><a name=\"dicom-sr-measurement-report-to-fhir-en-US\"> </a><p>Mapping from DICOM-SR-Measurement-Report to <a href=\"http://hl7.org/fhir/R5/bundle.html\">Bundle</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Patient (Patient IE)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Patient[1]</td><td>The DICOM® SR Patient IE is mapped to a FHIR Patient resource</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Study (Study IE)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>ImagingStudy[1]</td><td>The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource</td></tr><tr><td>DICOM.Study (Study IE)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#related-to\" title=\"related-to\">is related to</a></td><td>ServiceRequest[1]</td><td>The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Equipment (Equipment IE)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>Device[1]</td><td>The DICOM® SR Equipment IE may result in the creation of a new Device resource</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Document (Document IE)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td>Observation[1]</td><td>Processing of the Document IE will result in the creation one or more new Observation resources</td></tr></table></div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "ii"
}
],
"url" : "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir",
"identifier" : [
{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.40.39.18.7"
}
],
"version" : "1.0.0",
"name" : "DICOMSRMeasurementReportToFHIRMapping",
"title" : "ConceptMap - DICOM SR Measurement Report to FHIR Mapping",
"status" : "active",
"experimental" : false,
"date" : "2024-09-23T13:34:34+00:00",
"publisher" : "HL7 International / Imaging Integration",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name" : "HL7 International / Imaging Integration",
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name" : "Jonathan Whitby",
"telecom" : [
{
"system" : "email",
"value" : "jonathan.whitby@mi.medical.canon"
},
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name" : "Christopher Lindop",
"telecom" : [
{
"system" : "email",
"value" : "Christopher.Lindop@ge.com"
},
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/imagemgt"
}
]
}
],
"description" : "Mapping between DICOM® SR Measurement Report and FHIR Resources",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001"
}
]
}
],
"property" : [
{
"code" : "references",
"type" : "string"
},
{
"code" : "imaging-measurement-group-map",
"type" : "string"
}
],
"sourceScopeUri" : "DICOM-SR-Measurement-Report",
"targetScopeUri" : "Bundle",
"group" : [
{
"element" : [
{
"code" : "DICOM.Patient",
"display" : "Patient IE",
"target" : [
{
"code" : "Patient[1]",
"display" : "Patient[1]",
"relationship" : "equivalent",
"comment" : "The DICOM® SR Patient IE is mapped to a FHIR Patient resource"
}
]
}
]
},
{
"element" : [
{
"code" : "DICOM.Study",
"display" : "Study IE",
"target" : [
{
"code" : "ImagingStudy[1]",
"display" : "ImagingStudy[1]",
"relationship" : "equivalent",
"comment" : "The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource"
}
]
},
{
"code" : "DICOM.Study",
"display" : "Study IE",
"target" : [
{
"code" : "ServiceRequest[1]",
"display" : "ServiceRequest[1]",
"relationship" : "related-to",
"comment" : "The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource"
}
]
}
]
},
{
"element" : [
{
"code" : "DICOM.Equipment",
"display" : "Equipment IE",
"target" : [
{
"code" : "Device[1]",
"display" : "Device[1]",
"relationship" : "equivalent",
"comment" : "The DICOM® SR Equipment IE may result in the creation of a new Device resource"
}
]
}
]
},
{
"element" : [
{
"code" : "DICOM.Document",
"display" : "Document IE",
"target" : [
{
"code" : "Observation[1]",
"display" : "Observation[1]",
"relationship" : "source-is-narrower-than-target",
"comment" : "Processing of the Document IE will result in the creation one or more new Observation resources",
"property" : [
{
"code" : "imaging-measurement-group-map",
"valueString" : "dicom-imaging-measurement-group-to-fhir"
},
{
"code" : "references",
"valueString" : "Observation.subject.reference=Patient[1].id"
},
{
"code" : "references",
"valueString" : "Observation.partOf.reference=ImagingStudy[1].id"
},
{
"code" : "references",
"valueString" : "Observation.basedOn.reference=ServiceRequest[1].id"
},
{
"code" : "references",
"valueString" : "Observation.device.reference=Device[1]"
}
]
}
]
}
]
}
]
}