DICOM® SR to FHIR Resource Mapping IG
1.0.0 - STU1 Ballot International flag

DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: ConceptMap - DICOM Document IE to FHIR Mapping - XML Representation

Active as of 2024-09-23

Raw xml | Download


<ConceptMap xmlns="http://hl7.org/fhir">
  <id value="dicom-document-ie-to-fhir"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ConceptMap dicom-document-ie-to-fhir</b></p><a name="dicom-document-ie-to-fhir"> </a><a name="hcdicom-document-ie-to-fhir"> </a><a name="dicom-document-ie-to-fhir-en-US"> </a><p>Mapping from DICOM-Document to <a href="http://hl7.org/fhir/R5/bundle.html">Bundle</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td colspan="4"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan="2"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan="2"><b>Properties</b></td></tr><tr><td colspan="2"><b>Codes</b> from </td><td><b>DICOMConceptNameCodeSequence</b></td><td><b>OverserverType</b></td><td/><td colspan="2"><b>Codes</b> from </td><td/><td><b>macro-map</b></td><td><b>content-map</b></td></tr><tr><td style="border-right-width: 0px; border-bottom-style: none">DICOM.SR.Document.General</td><td style="border-left-width: 0px">Document General Module</td><td colspan="4" style="background-color: #efefef">(not mapped)</td></tr><tr><td style="border-right-width: 0px">DICOM.PreliminaryFlag</td><td style="border-left-width: 0px">Preliminary Flag (0040,A496)</td><td/><td/><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td style="border-right-width: 0px">status</td><td style="border-left-width: 0px">status</td><td>DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'.</td><td>todo</td><td>todo</td></tr><tr><td style="border-right-width: 0px">DICOM.ParticipantSequence-Performer</td><td style="border-left-width: 0px">Participant Sequence (0040,A07A) -- PSN</td><td/><td>PSN</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td style="border-right-width: 0px">performer</td><td style="border-left-width: 0px">performer</td><td/><td>todo</td><td>todo</td></tr><tr><td style="border-right-width: 0px">DICOM.ParticipantSequence-Device</td><td style="border-left-width: 0px">Participant Sequence (0040,A07A) -- DEV</td><td/><td>DEV</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td style="border-right-width: 0px">Device[1]</td><td style="border-left-width: 0px">Device[1]</td><td>If this device matches the Equipment IE device an additional device resource does not need to be created.</td><td>todo</td><td>todo</td></tr><tr><td style="border-right-width: 0px">DICOM.ContentSequence.ImagingMeasurements</td><td style="border-left-width: 0px">Content Sequence (0040,A730) -- Imaging Measurements</td><td/><td/><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#source-is-narrower-than-target" title="source-is-narrower-than-target">is narrower than</a></td><td style="border-right-width: 0px">Observation[1]</td><td style="border-left-width: 0px">Observation[1]</td><td/><td>todo</td><td>todo</td></tr></table></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="ii"/>
  </extension>
  <url
       value="http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir"/>
  <identifier>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:2.16.840.1.113883.4.642.40.39.18.2"/>
  </identifier>
  <version value="1.0.0"/>
  <name value="DICOMDocumentIEToFHIRMapping"/>
  <title value="ConceptMap - DICOM Document IE to FHIR Mapping"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2024-09-23T13:34:34+00:00"/>
  <publisher value="HL7 International / Imaging Integration"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/imagemgt"/>
    </telecom>
  </contact>
  <contact>
    <name value="HL7 International / Imaging Integration"/>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/imagemgt"/>
    </telecom>
  </contact>
  <contact>
    <name value="Jonathan Whitby"/>
    <telecom>
      <system value="email"/>
      <value value="jonathan.whitby@mi.medical.canon"/>
    </telecom>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/imagemgt"/>
    </telecom>
  </contact>
  <contact>
    <name value="Christopher Lindop"/>
    <telecom>
      <system value="email"/>
      <value value="Christopher.Lindop@ge.com"/>
    </telecom>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/imagemgt"/>
    </telecom>
  </contact>
  <description value="Mapping between DICOM® Document IE and FHIR Resources"/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
    </coding>
  </jurisdiction>
  <property>
    <code value="macro-map"/>
    <type value="string"/>
  </property>
  <property>
    <code value="content-map"/>
    <type value="string"/>
  </property>
  <additionalAttribute>
    <code value="OverserverType"/>
    <uri
         value="https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.2.4.html#table_C.17-3b"/>
    <description value="DICOM.ParticipantSequence.ObserverType"/>
    <type value="code"/>
  </additionalAttribute>
  <additionalAttribute>
    <code value="DICOMConceptNameCodeSequence"/>
    <uri
         value="https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.3.3.html#table_C.17-5"/>
    <description value="DICOM Concept Name Code Sequence (0040,A043)"/>
    <type value="Coding"/>
  </additionalAttribute>
  <sourceScopeUri value="DICOM-Document"/>
  <targetScopeUri value="Bundle"/>
  <group>
    <element>
      <code value="DICOM.SR.Document.General"/>
      <display value="Document General Module"/>
      <noMap value="true"/>
    </element>
    <element>
      <code value="DICOM.PreliminaryFlag"/>
      <display value="Preliminary Flag (0040,A496)"/>
      <target>
        <code value="status"/>
        <display value="status"/>
        <relationship value="equivalent"/>
        <comment
                 value="DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'."/>
      </target>
    </element>
    <element>
      <code value="DICOM.ParticipantSequence-Performer"/>
      <display value="Participant Sequence (0040,A07A) -- PSN"/>
      <target>
        <code value="performer"/>
        <display value="performer"/>
        <relationship value="equivalent"/>
        <property>
          <code value="macro-map"/>
          <valueString value="identified-person-or-device"/>
        </property>
        <dependsOn>
          <attribute value="OverserverType"/>
          <valueCode value="PSN"/>
        </dependsOn>
      </target>
    </element>
    <element>
      <code value="DICOM.ParticipantSequence-Device"/>
      <display value="Participant Sequence (0040,A07A) -- DEV"/>
      <target>
        <code value="Device[1]"/>
        <display value="Device[1]"/>
        <relationship value="equivalent"/>
        <comment
                 value="If this device matches the Equipment IE device an additional device resource does not need to be created."/>
        <property>
          <code value="macro-map"/>
          <valueString value="identified-person-or-device"/>
        </property>
        <dependsOn>
          <attribute value="OverserverType"/>
          <valueCode value="DEV"/>
        </dependsOn>
      </target>
    </element>
    <element>
      <code value="DICOM.ContentSequence.ImagingMeasurements"/>
      <display value="Content Sequence (0040,A730) -- Imaging Measurements"/>
      <target>
        <code value="Observation[1]"/>
        <display value="Observation[1]"/>
        <relationship value="source-is-narrower-than-target"/>
        <property>
          <code value="content-map"/>
          <valueString value="dicom-imaging-measurement-group"/>
        </property>
        <dependsOn>
          <attribute value="DICOMConceptNameCodeSequence"/>
          <valueCoding>
            <system value="http://dicom.nema.org/resources/ontology/DCM"/>
            <code value="126010"/>
            <display value="Imaging Measurements"/>
          </valueCoding>
        </dependsOn>
      </target>
    </element>
  </group>