DICOM® SR to FHIR Resource Mapping IG
1.0.0 - STU1 Ballot International flag

DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: ConceptMap - DICOM Document IE to FHIR Mapping - JSON Representation

Active as of 2024-09-23

Raw json | Download

{
  "resourceType" : "ConceptMap",
  "id" : "dicom-document-ie-to-fhir",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap dicom-document-ie-to-fhir</b></p><a name=\"dicom-document-ie-to-fhir\"> </a><a name=\"hcdicom-document-ie-to-fhir\"> </a><a name=\"dicom-document-ie-to-fhir-en-US\"> </a><p>Mapping from DICOM-Document to <a href=\"http://hl7.org/fhir/R5/bundle.html\">Bundle</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"4\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>DICOMConceptNameCodeSequence</b></td><td><b>OverserverType</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td><td/><td><b>macro-map</b></td><td><b>content-map</b></td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">DICOM.SR.Document.General</td><td style=\"border-left-width: 0px\">Document General Module</td><td colspan=\"4\" style=\"background-color: #efefef\">(not mapped)</td></tr><tr><td style=\"border-right-width: 0px\">DICOM.PreliminaryFlag</td><td style=\"border-left-width: 0px\">Preliminary Flag (0040,A496)</td><td/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">status</td><td style=\"border-left-width: 0px\">status</td><td>DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'.</td><td>todo</td><td>todo</td></tr><tr><td style=\"border-right-width: 0px\">DICOM.ParticipantSequence-Performer</td><td style=\"border-left-width: 0px\">Participant Sequence (0040,A07A) -- PSN</td><td/><td>PSN</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">performer</td><td style=\"border-left-width: 0px\">performer</td><td/><td>todo</td><td>todo</td></tr><tr><td style=\"border-right-width: 0px\">DICOM.ParticipantSequence-Device</td><td style=\"border-left-width: 0px\">Participant Sequence (0040,A07A) -- DEV</td><td/><td>DEV</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">Device[1]</td><td style=\"border-left-width: 0px\">Device[1]</td><td>If this device matches the Equipment IE device an additional device resource does not need to be created.</td><td>todo</td><td>todo</td></tr><tr><td style=\"border-right-width: 0px\">DICOM.ContentSequence.ImagingMeasurements</td><td style=\"border-left-width: 0px\">Content Sequence (0040,A730) -- Imaging Measurements</td><td/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#source-is-narrower-than-target\" title=\"source-is-narrower-than-target\">is narrower than</a></td><td style=\"border-right-width: 0px\">Observation[1]</td><td style=\"border-left-width: 0px\">Observation[1]</td><td/><td>todo</td><td>todo</td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "ii"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.4.642.40.39.18.2"
    }
  ],
  "version" : "1.0.0",
  "name" : "DICOMDocumentIEToFHIRMapping",
  "title" : "ConceptMap - DICOM Document IE to FHIR Mapping",
  "status" : "active",
  "experimental" : false,
  "date" : "2024-09-23T13:34:34+00:00",
  "publisher" : "HL7 International / Imaging Integration",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "HL7 International / Imaging Integration",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "Jonathan Whitby",
      "telecom" : [
        {
          "system" : "email",
          "value" : "jonathan.whitby@mi.medical.canon"
        },
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "Christopher Lindop",
      "telecom" : [
        {
          "system" : "email",
          "value" : "Christopher.Lindop@ge.com"
        },
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    }
  ],
  "description" : "Mapping between DICOM® Document IE and FHIR Resources",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "property" : [
    {
      "code" : "macro-map",
      "type" : "string"
    },
    {
      "code" : "content-map",
      "type" : "string"
    }
  ],
  "additionalAttribute" : [
    {
      "code" : "OverserverType",
      "uri" : "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.2.4.html#table_C.17-3b",
      "description" : "DICOM.ParticipantSequence.ObserverType",
      "type" : "code"
    },
    {
      "code" : "DICOMConceptNameCodeSequence",
      "uri" : "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.3.3.html#table_C.17-5",
      "description" : "DICOM Concept Name Code Sequence (0040,A043)",
      "type" : "Coding"
    }
  ],
  "sourceScopeUri" : "DICOM-Document",
  "targetScopeUri" : "Bundle",
  "group" : [
    {
      "element" : [
        {
          "code" : "DICOM.SR.Document.General",
          "display" : "Document General Module",
          "noMap" : true
        },
        {
          "code" : "DICOM.PreliminaryFlag",
          "display" : "Preliminary Flag (0040,A496)",
          "target" : [
            {
              "code" : "status",
              "display" : "status",
              "relationship" : "equivalent",
              "comment" : "DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'."
            }
          ]
        },
        {
          "code" : "DICOM.ParticipantSequence-Performer",
          "display" : "Participant Sequence (0040,A07A) -- PSN",
          "target" : [
            {
              "code" : "performer",
              "display" : "performer",
              "relationship" : "equivalent",
              "property" : [
                {
                  "code" : "macro-map",
                  "valueString" : "identified-person-or-device"
                }
              ],
              "dependsOn" : [
                {
                  "attribute" : "OverserverType",
                  "valueCode" : "PSN"
                }
              ]
            }
          ]
        },
        {
          "code" : "DICOM.ParticipantSequence-Device",
          "display" : "Participant Sequence (0040,A07A) -- DEV",
          "target" : [
            {
              "code" : "Device[1]",
              "display" : "Device[1]",
              "relationship" : "equivalent",
              "comment" : "If this device matches the Equipment IE device an additional device resource does not need to be created.",
              "property" : [
                {
                  "code" : "macro-map",
                  "valueString" : "identified-person-or-device"
                }
              ],
              "dependsOn" : [
                {
                  "attribute" : "OverserverType",
                  "valueCode" : "DEV"
                }
              ]
            }
          ]
        },
        {
          "code" : "DICOM.ContentSequence.ImagingMeasurements",
          "display" : "Content Sequence (0040,A730) -- Imaging Measurements",
          "target" : [
            {
              "code" : "Observation[1]",
              "display" : "Observation[1]",
              "relationship" : "source-is-narrower-than-target",
              "property" : [
                {
                  "code" : "content-map",
                  "valueString" : "dicom-imaging-measurement-group"
                }
              ],
              "dependsOn" : [
                {
                  "attribute" : "DICOMConceptNameCodeSequence",
                  "valueCoding" : {
                    "system" : "http://dicom.nema.org/resources/ontology/DCM",
                    "code" : "126010",
                    "display" : "Imaging Measurements"
                  }
                }
              ]
            }
          ]
        }
      ]
    }
  ]
}