Da Vinci Prior Authorization Support (PAS) FHIR IG, published by HL7 International / Financial Management. This guide is not an authorized publication; it is the continuous build for version 2.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/davinci-pas/ and changes regularly. See the Directory of published versions

Data Type Profile: PAS Quantity

Official URL: http://hl7.org/fhir/us/davinci-pas/StructureDefinition/profile-quantity Version: 2.1.0
Standards status: Trial-use Maturity Level: 3 Computable Name: PASQuantity
Other Identifiers: OID:2.16.840.1.113883.4.642.40.24.42.70

Constraints and extensions on SimpleQuantity which restricts the units.

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from SimpleQuantity

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity SimpleQuantity
... code 0..1 code Coded form of the unit
Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Quantity.coderequiredhttps://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A fixed quantity (no comparator)
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... code Σ 0..1 code Coded form of the unit
Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required)
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.coderequiredhttps://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A fixed quantity (no comparator)
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... id 0..1 string Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... value Σ 0..1 decimal Numerical value (with implicit precision)
... system ΣC 0..1 uri System that defines coded unit form
... code Σ 0..1 code Coded form of the unit
Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.coderequiredhttps://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673

This structure is derived from SimpleQuantity

Summary

Maturity: 3

Differential View

This structure is derived from SimpleQuantity

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity SimpleQuantity
... code 0..1 code Coded form of the unit
Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Quantity.coderequiredhttps://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A fixed quantity (no comparator)
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... code Σ 0..1 code Coded form of the unit
Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required)
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.coderequiredhttps://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A fixed quantity (no comparator)
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... id 0..1 string Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... value Σ 0..1 decimal Numerical value (with implicit precision)
... system ΣC 0..1 uri System that defines coded unit form
... code Σ 0..1 code Coded form of the unit
Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.coderequiredhttps://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673
https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673

This structure is derived from SimpleQuantity

Summary

Maturity: 3

 

Other representations of profile: CSV, Excel, Schematron