CodeX Radiation Therapy
2.0.0 - STU2 United States of America flag

CodeX Radiation Therapy, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/codex-radiation-therapy/ and changes regularly. See the Directory of published versions

Resource Profile: Radiotherapy Seed Device

Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-seed-device Version: 2.0.0
Active as of 2024-12-18 Computable Name: RadiotherapySeedDevice
Other Identifiers: OID:2.16.840.1.113883.4.642.40.14.42.28

A device that represents implanted seeds for brachytherapy. The device is specified by the type of radioactive seed (at a minimum).

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from USCoreImplantableDeviceProfile

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device USCoreImplantableDeviceProfile
... type 1..1 CodeableConcept (USCDI) The kind or type of device
Binding: Brachytherapy Device Type Value Set (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Device.typerequiredBrachytherapyDeviceTypeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs
from this IG
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* USCoreImplantableDeviceProfile Item used in healthcare
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... udiCarrier SΣ 0..1 BackboneElement (USCDI) Unique Device Identifier (UDI) Barcode string
ele-1: All FHIR elements must have a @value or children
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... deviceIdentifier SΣ 1..1 string (USCDI) Mandatory fixed portion of UDI
ele-1: All FHIR elements must have a @value or children
.... carrierHRF SΣ 0..1 string (USCDI) UDI Human Readable Barcode String
ele-1: All FHIR elements must have a @value or children
... distinctIdentifier S 0..1 string (USCDI) The distinct identification string
ele-1: All FHIR elements must have a @value or children
... manufactureDate S 0..1 dateTime (USCDI) Date when the device was made
ele-1: All FHIR elements must have a @value or children
... expirationDate S 0..1 dateTime (USCDI) Date and time of expiry of this device (if applicable)
ele-1: All FHIR elements must have a @value or children
... lotNumber S 0..1 string (USCDI) Lot number of manufacture
ele-1: All FHIR elements must have a @value or children
... serialNumber S 0..1 string (USCDI) Serial number assigned by the manufacturer
ele-1: All FHIR elements must have a @value or children
... type S 1..1 CodeableConcept (USCDI) The kind or type of device
Binding: Brachytherapy Device Type Value Set (required)
ele-1: All FHIR elements must have a @value or children
... patient S 1..1 Reference(US Core Patient Profile) (USCDI) Patient to whom Device is affixed
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.typerequiredBrachytherapyDeviceTypeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs
from this IG
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* USCoreImplantableDeviceProfile Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier SΣ 0..1 BackboneElement (USCDI) Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier SΣ 1..1 string (USCDI) Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF SΣ 0..1 string (USCDI) UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier S 0..1 string (USCDI) The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate S 0..1 dateTime (USCDI) Date when the device was made
... expirationDate S 0..1 dateTime (USCDI) Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string (USCDI) Lot number of manufacture
... serialNumber S 0..1 string (USCDI) Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type S 1..1 CodeableConcept (USCDI) The kind or type of device
Binding: Brachytherapy Device Type Value Set (required)
... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient S 1..1 Reference(US Core Patient Profile) (USCDI) Patient to whom Device is affixed
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
Device.udiCarrier.entryTyperequiredUDIEntryType
http://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1
from the FHIR Standard
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.statusReasonextensibleFHIRDeviceStatusReason
http://hl7.org/fhir/ValueSet/device-status-reason
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard
Device.typerequiredBrachytherapyDeviceTypeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs
from this IG

This structure is derived from USCoreImplantableDeviceProfile

Summary

Differential View

This structure is derived from USCoreImplantableDeviceProfile

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device USCoreImplantableDeviceProfile
... type 1..1 CodeableConcept (USCDI) The kind or type of device
Binding: Brachytherapy Device Type Value Set (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Device.typerequiredBrachytherapyDeviceTypeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs
from this IG

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* USCoreImplantableDeviceProfile Item used in healthcare
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... udiCarrier SΣ 0..1 BackboneElement (USCDI) Unique Device Identifier (UDI) Barcode string
ele-1: All FHIR elements must have a @value or children
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... deviceIdentifier SΣ 1..1 string (USCDI) Mandatory fixed portion of UDI
ele-1: All FHIR elements must have a @value or children
.... carrierHRF SΣ 0..1 string (USCDI) UDI Human Readable Barcode String
ele-1: All FHIR elements must have a @value or children
... distinctIdentifier S 0..1 string (USCDI) The distinct identification string
ele-1: All FHIR elements must have a @value or children
... manufactureDate S 0..1 dateTime (USCDI) Date when the device was made
ele-1: All FHIR elements must have a @value or children
... expirationDate S 0..1 dateTime (USCDI) Date and time of expiry of this device (if applicable)
ele-1: All FHIR elements must have a @value or children
... lotNumber S 0..1 string (USCDI) Lot number of manufacture
ele-1: All FHIR elements must have a @value or children
... serialNumber S 0..1 string (USCDI) Serial number assigned by the manufacturer
ele-1: All FHIR elements must have a @value or children
... type S 1..1 CodeableConcept (USCDI) The kind or type of device
Binding: Brachytherapy Device Type Value Set (required)
ele-1: All FHIR elements must have a @value or children
... patient S 1..1 Reference(US Core Patient Profile) (USCDI) Patient to whom Device is affixed
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.typerequiredBrachytherapyDeviceTypeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs
from this IG

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..* USCoreImplantableDeviceProfile Item used in healthcare
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... language 0..1 code Language of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguages Max Binding
... text 0..1 Narrative Text summary of the resource, for human interpretation
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier 0..* Identifier Instance identifier
... definition 0..1 Reference(DeviceDefinition) The reference to the definition for the device
... udiCarrier SΣ 0..1 BackboneElement (USCDI) Unique Device Identifier (UDI) Barcode string
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... deviceIdentifier SΣ 1..1 string (USCDI) Mandatory fixed portion of UDI
.... issuer 0..1 uri UDI Issuing Organization
.... jurisdiction 0..1 uri Regional UDI authority
.... carrierAIDC Σ 0..1 base64Binary UDI Machine Readable Barcode String
.... carrierHRF SΣ 0..1 string (USCDI) UDI Human Readable Barcode String
.... entryType 0..1 code barcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!Σ 0..1 code active | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..* CodeableConcept online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier S 0..1 string (USCDI) The distinct identification string
... manufacturer 0..1 string Name of device manufacturer
... manufactureDate S 0..1 dateTime (USCDI) Date when the device was made
... expirationDate S 0..1 dateTime (USCDI) Date and time of expiry of this device (if applicable)
... lotNumber S 0..1 string (USCDI) Lot number of manufacture
... serialNumber S 0..1 string (USCDI) Serial number assigned by the manufacturer
... deviceName 0..* BackboneElement The name of the device as given by the manufacturer
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... name 1..1 string The name of the device
.... type 1..1 code udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 0..1 string The model number for the device
... partNumber 0..1 string The part number of the device
... type S 1..1 CodeableConcept (USCDI) The kind or type of device
Binding: Brachytherapy Device Type Value Set (required)
... specialization 0..* BackboneElement The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... systemType 1..1 CodeableConcept The standard that is used to operate and communicate
.... version 0..1 string The version of the standard that is used to operate and communicate
... version 0..* BackboneElement The actual design of the device or software version running on the device
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 0..1 CodeableConcept The type of the device version
.... component 0..1 Identifier A single component of the device version
.... value 1..1 string The version text
... property 0..* BackboneElement The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1 string Unique id for inter-element referencing
.... extension 0..* Extension Additional content defined by implementations
.... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
.... type 1..1 CodeableConcept Code that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..* Quantity Property value as a quantity
.... valueCode 0..* CodeableConcept Property value as a code, e.g., NTP4 (synced to NTP)
... patient S 1..1 Reference(US Core Patient Profile) (USCDI) Patient to whom Device is affixed
... owner 0..1 Reference(Organization) Organization responsible for device
... contact 0..* ContactPoint Details for human/organization for support
... location 0..1 Reference(Location) Where the device is found
... url 0..1 uri Network address to contact device
... note 0..* Annotation Device notes and comments
... safety Σ 0..* CodeableConcept Safety Characteristics of Device
... parent 0..1 Reference(Device) The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Device.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
from the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
Device.udiCarrier.entryTyperequiredUDIEntryType
http://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1
from the FHIR Standard
Device.statusrequiredFHIRDeviceStatus
http://hl7.org/fhir/ValueSet/device-status|4.0.1
from the FHIR Standard
Device.statusReasonextensibleFHIRDeviceStatusReason
http://hl7.org/fhir/ValueSet/device-status-reason
from the FHIR Standard
Device.deviceName.typerequiredDeviceNameType
http://hl7.org/fhir/ValueSet/device-nametype|4.0.1
from the FHIR Standard
Device.typerequiredBrachytherapyDeviceTypeVS
http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs
from this IG

This structure is derived from USCoreImplantableDeviceProfile

Summary

 

Other representations of profile: CSV, Excel, Schematron