Consumer Mobile Health Application Functional Framework, Release 2
2.0.1 - CI build International flag

Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions

: AIG.5 Human Factors, Explainability, and Human Oversight (Function)

Page standards status: Informative

Raw xml | Download


<Requirements xmlns="http://hl7.org/fhir">
  <id value="CMHAFFR2-AIG.5"/>
  <meta>
    <profile
             value="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    
    
    
    
    <div id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></div>
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.5#01
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF an AI function can influence a high-impact health, safety, access, or financial decision THEN the system SHALL provide a risk-appropriate human or consumer review, correction, override, or escalation pathway before an irreversible or high-impact action is taken, unless a documented exception is required for immediate safety and is permitted by applicable rules.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.5#02
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system uses AI functionality THEN the system SHALL enable a consumer to view or correct material input data that the consumer provided or that the system attributes to the consumer when incorrect input could materially affect the AI output.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.5#03
            </td>
            <td style="padding-left: 4px;">
            SHOULD
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system displays AI output THEN the system SHOULD provide a meaningful explanation of the primary factors, data limitations, or evidence sources relevant to the output, at a level appropriate to the consumer and the risk of the intended use.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.5#04
            </td>
            <td style="padding-left: 4px;">
            MAY
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system uses AI functionality THEN the system MAY offer alternative explanation formats, such as plain-language summaries, detailed technical explanations, visual context, or translated content.</p>

                
            </td>
        </tr>
        
    </table>
    
</div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="mobile"/>
  </extension>
  <url value="http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-AIG.5"/>
  <version value="2.0.1"/>
  <name value="AIG_5_Human_Factors__Explainability__and_Human_Oversight"/>
  <title
         value="AIG.5 Human Factors, Explainability, and Human Oversight (Function)"/>
  <status value="active"/>
  <date value="2026-11-18T11:24:54+00:00"/>
  <publisher value="HL7 International / Mobile Health"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/mobile"/>
    </telecom>
  </contact>
  <description
               value="This category is about what the consumer can see, correct, question, and override. It covers review and escalation pathways before high-impact or irreversible actions, correction of faulty input data, and explanation at a level appropriate to the consumer and the risk of the intended use."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.5-01"/>
    <label value="AIG.5#01"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF an AI function can influence a high-impact health, safety, access, or financial decision THEN the system SHALL provide a risk-appropriate human or consumer review, correction, override, or escalation pathway before an irreversible or high-impact action is taken, unless a documented exception is required for immediate safety and is permitted by applicable rules."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.5-02"/>
    <label value="AIG.5#02"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system uses AI functionality THEN the system SHALL enable a consumer to view or correct material input data that the consumer provided or that the system attributes to the consumer when incorrect input could materially affect the AI output."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.5-03"/>
    <label value="AIG.5#03"/>
    <conformance value="SHOULD"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system displays AI output THEN the system SHOULD provide a meaningful explanation of the primary factors, data limitations, or evidence sources relevant to the output, at a level appropriate to the consumer and the risk of the intended use."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.5-04"/>
    <label value="AIG.5#04"/>
    <conformance value="MAY"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system uses AI functionality THEN the system MAY offer alternative explanation formats, such as plain-language summaries, detailed technical explanations, visual context, or translated content."/>
  </statement>
</Requirements>