Consumer Mobile Health Application Functional Framework, Release 2
2.0.1 - CI build
Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
{
"resourceType" : "Requirements",
"id" : "CMHAFFR2-AIG.5",
"meta" : {
"profile" : [
🔗 "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n \n \n \n \n <div id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></div>\n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n AIG.5#01\n </td>\n <td style=\"padding-left: 4px;\">\n SHALL\n \n \n <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n \n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n <p>IF an AI function can influence a high-impact health, safety, access, or financial decision THEN the system SHALL provide a risk-appropriate human or consumer review, correction, override, or escalation pathway before an irreversible or high-impact action is taken, unless a documented exception is required for immediate safety and is permitted by applicable rules.</p>\n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n AIG.5#02\n </td>\n <td style=\"padding-left: 4px;\">\n SHALL\n \n \n <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n \n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n <p>IF the system uses AI functionality THEN the system SHALL enable a consumer to view or correct material input data that the consumer provided or that the system attributes to the consumer when incorrect input could materially affect the AI output.</p>\n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n AIG.5#03\n </td>\n <td style=\"padding-left: 4px;\">\n SHOULD\n \n \n <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n \n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n <p>IF the system displays AI output THEN the system SHOULD provide a meaningful explanation of the primary factors, data limitations, or evidence sources relevant to the output, at a level appropriate to the consumer and the risk of the intended use.</p>\n\n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n AIG.5#04\n </td>\n <td style=\"padding-left: 4px;\">\n MAY\n \n \n <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n \n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n <p>IF the system uses AI functionality THEN the system MAY offer alternative explanation formats, such as plain-language summaries, detailed technical explanations, visual context, or translated content.</p>\n\n \n </td>\n </tr>\n \n </table>\n \n</div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "mobile"
}
],
"url" : "http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-AIG.5",
"version" : "2.0.1",
"name" : "AIG_5_Human_Factors__Explainability__and_Human_Oversight",
"title" : "AIG.5 Human Factors, Explainability, and Human Oversight (Function)",
"status" : "active",
"date" : "2026-11-18T11:24:54+00:00",
"publisher" : "HL7 International / Mobile Health",
"contact" : [
{
"telecom" : [
{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/mobile"
}
]
}
],
"description" : "This category is about what the consumer can see, correct, question, and override. It covers review and escalation pathways before high-impact or irreversible actions, correction of faulty input data, and explanation at a level appropriate to the consumer and the risk of the intended use.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001",
"display" : "World"
}
]
}
],
"statement" : [
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "CMHAFFR2-AIG.5-01",
"label" : "AIG.5#01",
"conformance" : [
"SHALL"
],
"conditionality" : true,
"requirement" : "IF an AI function can influence a high-impact health, safety, access, or financial decision THEN the system SHALL provide a risk-appropriate human or consumer review, correction, override, or escalation pathway before an irreversible or high-impact action is taken, unless a documented exception is required for immediate safety and is permitted by applicable rules."
},
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "CMHAFFR2-AIG.5-02",
"label" : "AIG.5#02",
"conformance" : [
"SHALL"
],
"conditionality" : true,
"requirement" : "IF the system uses AI functionality THEN the system SHALL enable a consumer to view or correct material input data that the consumer provided or that the system attributes to the consumer when incorrect input could materially affect the AI output."
},
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "CMHAFFR2-AIG.5-03",
"label" : "AIG.5#03",
"conformance" : [
"SHOULD"
],
"conditionality" : true,
"requirement" : "IF the system displays AI output THEN the system SHOULD provide a meaningful explanation of the primary factors, data limitations, or evidence sources relevant to the output, at a level appropriate to the consumer and the risk of the intended use."
},
{
"extension" : [
{
"url" : "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent",
"valueBoolean" : false
}
],
"key" : "CMHAFFR2-AIG.5-04",
"label" : "AIG.5#04",
"conformance" : [
"MAY"
],
"conditionality" : true,
"requirement" : "IF the system uses AI functionality THEN the system MAY offer alternative explanation formats, such as plain-language summaries, detailed technical explanations, visual context, or translated content."
}
]
}