Vital Signs with Qualifying Elements, published by HL7 International - Clinical Information Modeling Initiative. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cimi-vital-signs/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/vitals/StructureDefinition/body-weight | Version: 2.0.0 | |||
Draft as of 2024-10-09 | Computable Name: BodyWeight | |||
Copyright/Legal: Logica Health, all rights reserved Creative Commons License |
The measured mass of an individual's body.
The Body Weight profile contains one observation, body weight. In addition, the profile contains the following qualifying observations with associated SNOMED CT value sets: observation-deviceCode, AssociatedSituation, MeasurementSetting.
The following examples are provided to illustrate conformant resource content to this profile.
FHIR path and element binding | Text Description | Code | Terminology |
---|---|---|---|
Observation.code | Body Weight | 29463-7 | LOINC |
Observation.extension(AssociatedSituation) | |||
Observation.extension(AssociatedSituation).value | Wearing street clothes with shoes (finding) | 971000205103 | SNOMED CT |
Value Set | Purpose |
---|---|
Weight Measurement Device value set | This value set contains concepts used to result the type of instrument used to measure a body weight, referencing the LOINC term 8356-8 Type of Weighing device. |
Body Weight Associated Situation value set | This value set contains concepts used to result the amount of clothing worn during the measure, referencing the SNOMED Code 248159006 "State of dress (observable entity)" and the LOINC term "Clothing worn during measure” 8352-7. |
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from observation-bodyweight
Path | Conformance | ValueSet | URI |
Observation.extension:measurmentDevice.value[x] | extensible | WeightMeasurementDevicehttp://hl7.org/fhir/us/vitals/ValueSet/weightMeasurementDeviceVS from this IG | |
Observation.extension:associatedSituation.value[x]:valueCodeableConcept | extensible | BodyWeightAssociatedSituationvaluesethttp://hl7.org/fhir/us/vitals/ValueSet/BodyWeightAssociatedSituationVS from this IG | |
Observation.value[x]:valueQuantity.code | required | WeightUOMVShttp://hl7.org/fhir/us/vitals/ValueSet/WeightUOMVS from this IG | |
Observation.interpretation | extensible | NumericResultInterpretationNonPanichttp://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS from this IG |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | observation-bodyweight | FHIR Body Weight Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
measurmentDevice | S | 0..1 | (Complex) | Measurement Device Type URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Weight Measurement Device value set (extensible) | |
associatedSituation | S | 0..1 | (Complex) | Associated Situation URL: http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt" | |
Slices for value[x] | 0..1 | CodeableConcept | Value of extension Slice: Unordered, Closed by type:$this | |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | Value of extension Binding: Associated Situation value set (extensible) | |
measurementSetting | S | 0..1 | CodeableConcept | Measurement setting URL: http://hl7.org/fhir/us/vitals/StructureDefinition/MeasurementSettingExt Binding: Measurement Setting value set (extensible) |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | Code defined by a terminology system |
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | Body weight Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 0..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
coding:BodyWeightCode | Σ | 1..1 | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 29463-7 |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
Slices for value[x] | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Closed by type:$this |
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Binding: Weight Units of Measure value set (required) |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: Numeric Result Interpretation without panic values, value set (extensible) | |
component | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.extension:measurmentDevice.value[x] | extensible | WeightMeasurementDevicehttp://hl7.org/fhir/us/vitals/ValueSet/weightMeasurementDeviceVS from this IG | |
Observation.extension:associatedSituation.value[x]:valueCodeableConcept | extensible | BodyWeightAssociatedSituationvaluesethttp://hl7.org/fhir/us/vitals/ValueSet/BodyWeightAssociatedSituationVS from this IG | |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.value[x]:valueQuantity.code | required | WeightUOMVShttp://hl7.org/fhir/us/vitals/ValueSet/WeightUOMVS from this IG | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.interpretation | extensible | NumericResultInterpretationNonPanichttp://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS from this IG | |
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component.value[x] | extensible | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | observation-bodyweight | FHIR Body Weight Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
measurmentDevice | S | 0..1 | (Complex) | Measurement Device Type URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |||||
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Weight Measurement Device value set (extensible) | |||||
associatedSituation | S | 0..1 | (Complex) | Associated Situation URL: http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt" | |||||
Slices for value[x] | 0..1 | CodeableConcept | Value of extension Slice: Unordered, Closed by type:$this | |||||
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | Value of extension Binding: Associated Situation value set (extensible) | |||||
measurementSetting | S | 0..1 | CodeableConcept | Measurement setting URL: http://hl7.org/fhir/us/vitals/StructureDefinition/MeasurementSettingExt Binding: Measurement Setting value set (extensible) | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | Body weight Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 0..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
coding:BodyWeightCode | Σ | 1..1 | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 29463-7 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
Slices for value[x] | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Closed by type:$this | ||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Binding: Weight Units of Measure value set (required) | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: Numeric Result Interpretation without panic values, value set (extensible) | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
component | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.extension:measurmentDevice.value[x] | extensible | WeightMeasurementDevicehttp://hl7.org/fhir/us/vitals/ValueSet/weightMeasurementDeviceVS from this IG | ||||
Observation.extension:associatedSituation.value[x]:valueCodeableConcept | extensible | BodyWeightAssociatedSituationvaluesethttp://hl7.org/fhir/us/vitals/ValueSet/BodyWeightAssociatedSituationVS from this IG | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.value[x]:valueQuantity.code | required | WeightUOMVShttp://hl7.org/fhir/us/vitals/ValueSet/WeightUOMVS from this IG | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | NumericResultInterpretationNonPanichttp://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS from this IG | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component.value[x] | extensible | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
This structure is derived from observation-bodyweight
Differential View
This structure is derived from observation-bodyweight
Path | Conformance | ValueSet | URI |
Observation.extension:measurmentDevice.value[x] | extensible | WeightMeasurementDevicehttp://hl7.org/fhir/us/vitals/ValueSet/weightMeasurementDeviceVS from this IG | |
Observation.extension:associatedSituation.value[x]:valueCodeableConcept | extensible | BodyWeightAssociatedSituationvaluesethttp://hl7.org/fhir/us/vitals/ValueSet/BodyWeightAssociatedSituationVS from this IG | |
Observation.value[x]:valueQuantity.code | required | WeightUOMVShttp://hl7.org/fhir/us/vitals/ValueSet/WeightUOMVS from this IG | |
Observation.interpretation | extensible | NumericResultInterpretationNonPanichttp://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS from this IG |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | observation-bodyweight | FHIR Body Weight Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |
measurmentDevice | S | 0..1 | (Complex) | Measurement Device Type URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Weight Measurement Device value set (extensible) | |
associatedSituation | S | 0..1 | (Complex) | Associated Situation URL: http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt" | |
Slices for value[x] | 0..1 | CodeableConcept | Value of extension Slice: Unordered, Closed by type:$this | |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | Value of extension Binding: Associated Situation value set (extensible) | |
measurementSetting | S | 0..1 | CodeableConcept | Measurement setting URL: http://hl7.org/fhir/us/vitals/StructureDefinition/MeasurementSettingExt Binding: Measurement Setting value set (extensible) |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) |
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. |
coding | SΣ | 1..* | Coding | Code defined by a terminology system |
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category |
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs |
code | SΣ | 1..1 | CodeableConcept | Body weight Binding: VitalSigns (extensible): This identifies the vital sign result type. |
Slices for coding | Σ | 0..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
coding:BodyWeightCode | Σ | 1..1 | Coding | Code defined by a terminology system |
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org |
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 29463-7 |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about |
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
Slices for value[x] | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Closed by type:$this |
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Binding: Weight Units of Measure value set (required) |
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: Numeric Result Interpretation without panic values, value set (extensible) | |
component | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Observation.extension:measurmentDevice.value[x] | extensible | WeightMeasurementDevicehttp://hl7.org/fhir/us/vitals/ValueSet/weightMeasurementDeviceVS from this IG | |
Observation.extension:associatedSituation.value[x]:valueCodeableConcept | extensible | BodyWeightAssociatedSituationvaluesethttp://hl7.org/fhir/us/vitals/ValueSet/BodyWeightAssociatedSituationVS from this IG | |
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | |
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | |
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | |
Observation.value[x]:valueQuantity.code | required | WeightUOMVShttp://hl7.org/fhir/us/vitals/ValueSet/WeightUOMVS from this IG | |
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | |
Observation.interpretation | extensible | NumericResultInterpretationNonPanichttp://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS from this IG | |
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | |
Observation.component.value[x] | extensible | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | |
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | observation-bodyweight | FHIR Body Weight Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | ||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
measurmentDevice | S | 0..1 | (Complex) | Measurement Device Type URL: http://hl7.org/fhir/StructureDefinition/observation-deviceCode | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/StructureDefinition/observation-deviceCode" | |||||
value[x] | 1..1 | CodeableConcept | Value of extension Binding: Weight Measurement Device value set (extensible) | |||||
associatedSituation | S | 0..1 | (Complex) | Associated Situation URL: http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/us/vitals/StructureDefinition/AssociatedSituationExt" | |||||
Slices for value[x] | 0..1 | CodeableConcept | Value of extension Slice: Unordered, Closed by type:$this | |||||
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | Value of extension Binding: Associated Situation value set (extensible) | |||||
measurementSetting | S | 0..1 | CodeableConcept | Measurement setting URL: http://hl7.org/fhir/us/vitals/StructureDefinition/MeasurementSettingExt Binding: Measurement Setting value set (extensible) | ||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) | ||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
category:VSCat | S | 1..1 | CodeableConcept | Classification of type of observation Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
coding | SΣ | 1..* | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | SΣ | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/observation-category | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | SΣ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: vital-signs | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
code | SΣ | 1..1 | CodeableConcept | Body weight Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
Slices for coding | Σ | 0..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | ||||
coding:BodyWeightCode | Σ | 1..1 | Coding | Code defined by a terminology system | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
system | Σ | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | ||||
version | Σ | 0..1 | string | Version of the system - if relevant | ||||
code | Σ | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 29463-7 | ||||
display | Σ | 0..1 | string | Representation defined by the system | ||||
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user | ||||
text | Σ | 0..1 | string | Plain text representation of the concept | ||||
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | ||||
effective[x] | SΣC | 1..1 | Often just a dateTime for Vital Signs vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day | |||||
effectiveDateTime | dateTime | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | ||||
Slices for value[x] | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Closed by type:$this | ||||
value[x]:valueQuantity | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) | ||||
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required): How the Quantity should be understood and represented. | ||||
unit | SΣ | 1..1 | string | Unit representation | ||||
system | SΣC | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org | ||||
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Binding: Weight Units of Measure value set (required) | ||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: Numeric Result Interpretation without panic values, value set (extensible) | |||||
note | 0..* | Annotation | Comments about the observation | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | ||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | ||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||
age | 0..1 | Range | Applicable age range, if relevant | |||||
text | 0..1 | string | Text based reference range in an observation | |||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | ||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | ||||
component | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. | ||||
value[x] | SΣC | 0..1 | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs. | |||||
valueQuantity | Quantity | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
Observation.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Observation.extension:measurmentDevice.value[x] | extensible | WeightMeasurementDevicehttp://hl7.org/fhir/us/vitals/ValueSet/weightMeasurementDeviceVS from this IG | ||||
Observation.extension:associatedSituation.value[x]:valueCodeableConcept | extensible | BodyWeightAssociatedSituationvaluesethttp://hl7.org/fhir/us/vitals/ValueSet/BodyWeightAssociatedSituationVS from this IG | ||||
Observation.status | required | ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1 from the FHIR Standard | ||||
Observation.category | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.category:VSCat | preferred | ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category from the FHIR Standard | ||||
Observation.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.value[x]:valueQuantity.comparator | required | QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1 from the FHIR Standard | ||||
Observation.value[x]:valueQuantity.code | required | WeightUOMVShttp://hl7.org/fhir/us/vitals/ValueSet/WeightUOMVS from this IG | ||||
Observation.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.interpretation | extensible | NumericResultInterpretationNonPanichttp://hl7.org/fhir/us/vitals/ValueSet/NumericResultIntNonPanicVS from this IG | ||||
Observation.bodySite | example | SNOMEDCTBodyStructureshttp://hl7.org/fhir/ValueSet/body-site from the FHIR Standard | ||||
Observation.method | example | ObservationMethodshttp://hl7.org/fhir/ValueSet/observation-methods from the FHIR Standard | ||||
Observation.referenceRange.type | preferred | ObservationReferenceRangeMeaningCodeshttp://hl7.org/fhir/ValueSet/referencerange-meaning from the FHIR Standard | ||||
Observation.referenceRange.appliesTo | example | ObservationReferenceRangeAppliesToCodeshttp://hl7.org/fhir/ValueSet/referencerange-appliesto from the FHIR Standard | ||||
Observation.component.code | extensible | VitalSignshttp://hl7.org/fhir/ValueSet/observation-vitalsignresult from the FHIR Standard | ||||
Observation.component.value[x] | extensible | VitalSignsUnitshttp://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1 from the FHIR Standard | ||||
Observation.component.dataAbsentReason | extensible | DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason from the FHIR Standard | ||||
Observation.component.interpretation | extensible | ObservationInterpretationCodeshttp://hl7.org/fhir/ValueSet/observation-interpretation from the FHIR Standard |
This structure is derived from observation-bodyweight
Other representations of profile: CSV, Excel, Schematron