CardX - Cardiac Implantable Electronic Devices
2.0.0 - ci-build International flag

CardX - Cardiac Implantable Electronic Devices, published by HL7 International / Clinical Interoperability Council. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/CardX-CIED/ and changes regularly. See the Directory of published versions

ValueSet: MDC IDC Value Set

Official URL: http://hl7.org/fhir/uv/cardx-cied/ValueSet/IDCvalues Version: 2.0.0
Standards status: Trial-use Active as of 2026-04-09 Maturity Level: 2 Computable Name: MDCidc

ValueSet for the MDC IDC partition.

References

Logical Definition (CLD)

Language: en

 

Expansion

Expansion performed internally based on codesystem MDC Nomenclature v2024-12-05 (CodeSystem)

This value set has 1,689 codes in it. In order to keep the publication size manageable, only a selection (1,000 codes) of the whole set of codes is shown.

SystemCodeDisplay (en)DefinitionJSONXML
urn:iso:std:iso:11073:10101  720897MDC_IDC_DEV_TYPE

The type of cardiac device.

urn:iso:std:iso:11073:10101  720898MDC_IDC_DEV_MODEL

The model identifier of a cardiac device.

urn:iso:std:iso:11073:10101  720899MDC_IDC_DEV_SERIAL

The serial number of a cardiac device.

urn:iso:std:iso:11073:10101  720900MDC_IDC_DEV_MFG

The manufacturer of the cardiac device.

urn:iso:std:iso:11073:10101  720901MDC_IDC_DEV_IMPLANT_DT

The implant date of the cardiac device.

urn:iso:std:iso:11073:10101  720902MDC_IDC_DEV_IMPLANTER

The name of the physician that implanted the cardiac device.

urn:iso:std:iso:11073:10101  720903MDC_IDC_DEV_IMPLANTER_CONTACT_INFO

The contact information of the physician that implanted the cardiac device.

urn:iso:std:iso:11073:10101  720904MDC_IDC_DEV_IMPLANTING_FACILITY
  1. The facility (clinic / hospital) where the cardiac device was implanted.
  2. The facility (clinic/hospital) where the cardiac device was implanted.
urn:iso:std:iso:11073:10101  720961MDC_IDC_LEAD_MODEL

The model of the lead.

urn:iso:std:iso:11073:10101  720962MDC_IDC_LEAD_SERIAL

The serial number of the lead.

urn:iso:std:iso:11073:10101  720963MDC_IDC_LEAD_MFG

The manufacturer of the lead.

urn:iso:std:iso:11073:10101  720964MDC_IDC_LEAD_IMPLANT_DT

The implant date of the lead.

urn:iso:std:iso:11073:10101  720965MDC_IDC_LEAD_POLARITY_TYPE

The number of electrodes on the lead.

urn:iso:std:iso:11073:10101  720966MDC_IDC_LEAD_LOCATION

The fixation location of the lead, usually indicating a chamber of the heart.

urn:iso:std:iso:11073:10101  720967MDC_IDC_LEAD_LOCATION_DETAIL_1

The first word of a combination of words describing further details of the location.

urn:iso:std:iso:11073:10101  720968MDC_IDC_LEAD_LOCATION_DETAIL_2

The second word of a combination of words describing further details of the location.

urn:iso:std:iso:11073:10101  720969MDC_IDC_LEAD_LOCATION_DETAIL_3

The third word of a combination of words describing further details of the location.

urn:iso:std:iso:11073:10101  720970MDC_IDC_LEAD_CONNECTION_STATUS

The physical connection status of the lead, either connected or abandoned.

urn:iso:std:iso:11073:10101  720971MDC_IDC_LEAD_SPECIAL_FUNCTION

A description of any special attribute or function of the lead.

urn:iso:std:iso:11073:10101  721025MDC_IDC_SESS_DTM

The date and time of the in-clinic or remote interrogation session.

urn:iso:std:iso:11073:10101  721026MDC_IDC_SESS_TYPE

The type of device interaction that generated the current data set.

urn:iso:std:iso:11073:10101  721027MDC_IDC_SESS_REPROGRAMMED
  1. The indication of whether the device was re-programmed during the session.
  2. The indication of whether the device was reprogrammed during the session.
urn:iso:std:iso:11073:10101  721028MDC_IDC_SESS_DTM_PREVIOUS

The date and time of a previous in-clinic or remote interrogation.

urn:iso:std:iso:11073:10101  721029MDC_IDC_SESS_TYPE_PREVIOUS

The type of device interaction of the previous interrogation.

urn:iso:std:iso:11073:10101  721030MDC_IDC_SESS_REPROGRAMMED_PREVIOUS
  1. The indication of whether the device was re-programmed along with the previous interrogation.
  2. The indication of whether the device was reprogrammed along with the previous interrogation.
urn:iso:std:iso:11073:10101  721031MDC_IDC_SESS_CLINICIAN_NAME

The name of the clinician that is responsible for the examination.

urn:iso:std:iso:11073:10101  721032MDC_IDC_SESS_CLINICIAN_CONTACT_INFORMATION

The contact information for the responsible clinician.

urn:iso:std:iso:11073:10101  721033MDC_IDC_SESS_CLINIC_NAME

The name of the clinic where the examination took place.

urn:iso:std:iso:11073:10101  721152MDC_IDC_MSMT_DTM

The date and time of a discrete or a group of measurements.

urn:iso:std:iso:11073:10101  721153MDC_IDC_MSMT_DTM_START

The date and time of a discrete or a group of measurements.

urn:iso:std:iso:11073:10101  721154MDC_IDC_MSMT_DTM_END

The date and time of a discrete or a group of measurements.

urn:iso:std:iso:11073:10101  721216MDC_IDC_MSMT_BATTERY_DTM

The date and time of the battery measurements.

urn:iso:std:iso:11073:10101  721280MDC_IDC_MSMT_BATTERY_STATUS

The different stages of battery depletion.

urn:iso:std:iso:11073:10101  721344MDC_IDC_MSMT_BATTERY_VOLTAGE

The measured battery voltage.

urn:iso:std:iso:11073:10101  721408MDC_IDC_MSMT_BATTERY_IMPEDANCE

The measured battery impedance.

urn:iso:std:iso:11073:10101  721472MDC_IDC_MSMT_BATTERY_REMAINING_LONGEVITY
  1. The estimated amount of battery capacity remaining in months.
  2. The estimated duration of battery operation remaining (in months).
urn:iso:std:iso:11073:10101  721536MDC_IDC_MSMT_BATTERY_REMAINING_PERCENTAGE
  1. The estimated amount of battery capacity remaining in percent.
  2. The estimated amount of battery capacity remaining (in percent).
urn:iso:std:iso:11073:10101  721600MDC_IDC_MSMT_BATTERY_RRT_TRIGGER

The criteria for determining battery end of service condition.

urn:iso:std:iso:11073:10101  721664MDC_IDC_MSMT_CAP_CHARGE_DTM

The date and time of the capacitor charge.

urn:iso:std:iso:11073:10101  721728MDC_IDC_MSMT_CAP_CHARGE_TIME

The duration in seconds of the capacitor charge.

urn:iso:std:iso:11073:10101  721792MDC_IDC_MSMT_CAP_CHARGE_ENERGY

The amount of energy stored after the capacitor charge.

urn:iso:std:iso:11073:10101  721856MDC_IDC_MSMT_CAP_CHARGE_TYPE

The type of the capacitor charge.

urn:iso:std:iso:11073:10101  721920MDC_IDC_MSMT_LEADCHNL_RA_DTM

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721921MDC_IDC_MSMT_LEADCHNL_RA_DTM_START

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721922MDC_IDC_MSMT_LEADCHNL_RA_DTM_END

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721924MDC_IDC_MSMT_LEADCHNL_RV_DTM

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721925MDC_IDC_MSMT_LEADCHNL_RV_DTM_START

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721926MDC_IDC_MSMT_LEADCHNL_RV_DTM_END

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721928MDC_IDC_MSMT_LEADCHNL_LA_DTM

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721929MDC_IDC_MSMT_LEADCHNL_LA_DTM_START

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721930MDC_IDC_MSMT_LEADCHNL_LA_DTM_END

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721932MDC_IDC_MSMT_LEADCHNL_LV_DTM

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721933MDC_IDC_MSMT_LEADCHNL_LV_DTM_START

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721934MDC_IDC_MSMT_LEADCHNL_LV_DTM_END

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721936MDC_IDC_MSMT_LEADCHNL_MIXED_DTM

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721937MDC_IDC_MSMT_LEADCHNL_MIXED_DTM_START

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721938MDC_IDC_MSMT_LEADCHNL_MIXED_DTM_END

The date and time of the lead channel measurements.

urn:iso:std:iso:11073:10101  721984MDC_IDC_MSMT_LEADCHNL_RA_LEAD_CHANNEL_STATUS

The indication whether to check the lead.

urn:iso:std:iso:11073:10101  721985MDC_IDC_MSMT_LEADCHNL_RV_LEAD_CHANNEL_STATUS

The indication whether to check the lead.

urn:iso:std:iso:11073:10101  721986MDC_IDC_MSMT_LEADCHNL_LA_LEAD_CHANNEL_STATUS

The indication whether to check the lead.

urn:iso:std:iso:11073:10101  721987MDC_IDC_MSMT_LEADCHNL_LV_LEAD_CHANNEL_STATUS

The indication whether to check the lead.

urn:iso:std:iso:11073:10101  721988MDC_IDC_MSMT_LEADCHNL_MIXED_LEAD_CHANNEL_STATUS

The indication whether to check the lead.

urn:iso:std:iso:11073:10101  722048MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722049MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MAX

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722050MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MIN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722051MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MEAN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722052MDC_IDC_MSMT_LEADCHNL_RV_SENSING_INTR_AMPL

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722053MDC_IDC_MSMT_LEADCHNL_RV_SENSING_INTR_AMPL_MAX

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722054MDC_IDC_MSMT_LEADCHNL_RV_SENSING_INTR_AMPL_MIN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722055MDC_IDC_MSMT_LEADCHNL_RV_SENSING_INTR_AMPL_MEAN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722056MDC_IDC_MSMT_LEADCHNL_LA_SENSING_INTR_AMPL

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722057MDC_IDC_MSMT_LEADCHNL_LA_SENSING_INTR_AMPL_MAX

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722058MDC_IDC_MSMT_LEADCHNL_LA_SENSING_INTR_AMPL_MIN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722059MDC_IDC_MSMT_LEADCHNL_LA_SENSING_INTR_AMPL_MEAN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722060MDC_IDC_MSMT_LEADCHNL_LV_SENSING_INTR_AMPL

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722061MDC_IDC_MSMT_LEADCHNL_LV_SENSING_INTR_AMPL_MAX

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722062MDC_IDC_MSMT_LEADCHNL_LV_SENSING_INTR_AMPL_MIN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722063MDC_IDC_MSMT_LEADCHNL_LV_SENSING_INTR_AMPL_MEAN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722064MDC_IDC_MSMT_LEADCHNL_MIXED_SENSING_INTR_AMPL

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722065MDC_IDC_MSMT_LEADCHNL_MIXED_SENSING_INTR_AMPL_MAX

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722066MDC_IDC_MSMT_LEADCHNL_MIXED_SENSING_INTR_AMPL_MIN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722067MDC_IDC_MSMT_LEADCHNL_MIXED_SENSING_INTR_AMPL_MEAN

The measured amplitude of the intrinsic cardiac signal.

urn:iso:std:iso:11073:10101  722112MDC_IDC_MSMT_LEADCHNL_RA_SENSING_POLARITY

The type of polarity used for the intrinsic amplitude measurement.

urn:iso:std:iso:11073:10101  722113MDC_IDC_MSMT_LEADCHNL_RV_SENSING_POLARITY

The type of polarity used for the intrinsic amplitude measurement.

urn:iso:std:iso:11073:10101  722114MDC_IDC_MSMT_LEADCHNL_LA_SENSING_POLARITY

The type of polarity used for the intrinsic amplitude measurement.

urn:iso:std:iso:11073:10101  722115MDC_IDC_MSMT_LEADCHNL_LV_SENSING_POLARITY

The type of polarity used for the intrinsic amplitude measurement.

urn:iso:std:iso:11073:10101  722116MDC_IDC_MSMT_LEADCHNL_MIXED_SENSING_POLARITY

The type of polarity used for the intrinsic amplitude measurement.

urn:iso:std:iso:11073:10101  722176MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_AMPLITUDE

The minimum pulse amplitude needed for pacing capture for a given pulse width.

urn:iso:std:iso:11073:10101  722177MDC_IDC_MSMT_LEADCHNL_RV_PACING_THRESHOLD_AMPLITUDE

The minimum pulse amplitude needed for pacing capture for a given pulse width.

urn:iso:std:iso:11073:10101  722178MDC_IDC_MSMT_LEADCHNL_LA_PACING_THRESHOLD_AMPLITUDE

The minimum pulse amplitude needed for pacing capture for a given pulse width.

urn:iso:std:iso:11073:10101  722179MDC_IDC_MSMT_LEADCHNL_LV_PACING_THRESHOLD_AMPLITUDE

The minimum pulse amplitude needed for pacing capture for a given pulse width.

urn:iso:std:iso:11073:10101  722180MDC_IDC_MSMT_LEADCHNL_MIXED_PACING_THRESHOLD_AMPLITUDE

The minimum pulse amplitude needed for pacing capture for a given pulse width.

urn:iso:std:iso:11073:10101  722240MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_PULSEWIDTH

The pulse width that was applied when determining the pacing threshold amplitude.

urn:iso:std:iso:11073:10101  722241MDC_IDC_MSMT_LEADCHNL_RV_PACING_THRESHOLD_PULSEWIDTH

The pulse width that was applied when determining the pacing threshold amplitude.

urn:iso:std:iso:11073:10101  722242MDC_IDC_MSMT_LEADCHNL_LA_PACING_THRESHOLD_PULSEWIDTH

The pulse width that was applied when determining the pacing threshold amplitude.

urn:iso:std:iso:11073:10101  722243MDC_IDC_MSMT_LEADCHNL_LV_PACING_THRESHOLD_PULSEWIDTH

The pulse width that was applied when determining the pacing threshold amplitude.

urn:iso:std:iso:11073:10101  722244MDC_IDC_MSMT_LEADCHNL_MIXED_PACING_THRESHOLD_PULSEWIDTH

The pulse width that was applied when determining the pacing threshold amplitude.

urn:iso:std:iso:11073:10101  722304MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_MEASUREMENT_METHOD

The method that was used to obtain the pacing threshold.

urn:iso:std:iso:11073:10101  722305MDC_IDC_MSMT_LEADCHNL_RV_PACING_THRESHOLD_MEASUREMENT_METHOD

The method that was used to obtain the pacing threshold.

urn:iso:std:iso:11073:10101  722306MDC_IDC_MSMT_LEADCHNL_LA_PACING_THRESHOLD_MEASUREMENT_METHOD

The method that was used to obtain the pacing threshold.

urn:iso:std:iso:11073:10101  722307MDC_IDC_MSMT_LEADCHNL_LV_PACING_THRESHOLD_MEASUREMENT_METHOD

The method that was used to obtain the pacing threshold.

urn:iso:std:iso:11073:10101  722308MDC_IDC_MSMT_LEADCHNL_MIXED_PACING_THRESHOLD_MEASUREMENT_METHOD

The method that was used to obtain the pacing threshold.

urn:iso:std:iso:11073:10101  722368MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_POLARITY

The type of lead polarity that was used for the pacing threshold measurement.

urn:iso:std:iso:11073:10101  722369MDC_IDC_MSMT_LEADCHNL_RV_PACING_THRESHOLD_POLARITY

The type of lead polarity that was used for the pacing threshold measurement.

urn:iso:std:iso:11073:10101  722370MDC_IDC_MSMT_LEADCHNL_LA_PACING_THRESHOLD_POLARITY

The type of lead polarity that was used for the pacing threshold measurement.

urn:iso:std:iso:11073:10101  722371MDC_IDC_MSMT_LEADCHNL_LV_PACING_THRESHOLD_POLARITY

The type of lead polarity that was used for the pacing threshold measurement.

urn:iso:std:iso:11073:10101  722372MDC_IDC_MSMT_LEADCHNL_MIXED_PACING_THRESHOLD_POLARITY

The type of lead polarity that was used for the pacing threshold measurement.

urn:iso:std:iso:11073:10101  722432MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_VALUE

The sum of the impedances of the lead wires and the electrode-myocardial interface.

urn:iso:std:iso:11073:10101  722433MDC_IDC_MSMT_LEADCHNL_RV_IMPEDANCE_VALUE

The sum of the impedances of the lead wires and the electrode-myocardial interface.

urn:iso:std:iso:11073:10101  722434MDC_IDC_MSMT_LEADCHNL_LA_IMPEDANCE_VALUE

The sum of the impedances of the lead wires and the electrode-myocardial interface.

urn:iso:std:iso:11073:10101  722435MDC_IDC_MSMT_LEADCHNL_LV_IMPEDANCE_VALUE

The sum of the impedances of the lead wires and the electrode-myocardial interface.

urn:iso:std:iso:11073:10101  722436MDC_IDC_MSMT_LEADCHNL_MIXED_IMPEDANCE_VALUE

The sum of the impedances of the lead wires and the electrode-myocardial interface.

urn:iso:std:iso:11073:10101  722496MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_POLARITY

The type of lead polarity used for measuring the lead impedance.

urn:iso:std:iso:11073:10101  722497MDC_IDC_MSMT_LEADCHNL_RV_IMPEDANCE_POLARITY

The type of lead polarity used for measuring the lead impedance.

urn:iso:std:iso:11073:10101  722498MDC_IDC_MSMT_LEADCHNL_LA_IMPEDANCE_POLARITY

The type of lead polarity used for measuring the lead impedance.

urn:iso:std:iso:11073:10101  722499MDC_IDC_MSMT_LEADCHNL_LV_IMPEDANCE_POLARITY

The type of lead polarity used for measuring the lead impedance.

urn:iso:std:iso:11073:10101  722500MDC_IDC_MSMT_LEADCHNL_MIXED_IMPEDANCE_POLARITY

The type of lead polarity used for measuring the lead impedance.

urn:iso:std:iso:11073:10101  722560MDC_IDC_MSMT_LEADHVCHNL_DTM

The date and time of the high voltage lead channel measurements.

urn:iso:std:iso:11073:10101  722561MDC_IDC_MSMT_LEADHVCHNL_DTM_START

The date and time of the high voltage lead channel measurements.

urn:iso:std:iso:11073:10101  722562MDC_IDC_MSMT_LEADHVCHNL_DTM_END

The date and time of the high voltage lead channel measurements.

urn:iso:std:iso:11073:10101  722624MDC_IDC_MSMT_LEADHVCHNL_IMPEDANCE

The sum of the impedances of the shock lead wires and the electrode-myocardial interface.

urn:iso:std:iso:11073:10101  722688MDC_IDC_MSMT_LEADHVCHNL_MEASUREMENT_TYPE

The electric pulse type used for measuring the shock lead impedance.

urn:iso:std:iso:11073:10101  722752MDC_IDC_MSMT_LEADHVCHNL_STATUS

The indication whether to check the high voltage lead.

urn:iso:std:iso:11073:10101  729344MDC_IDC_SET_CRT_LVRV_DELAY
  1. The time between the LV and RV pacing pulses (positive values indicate LV is first).
  2. The interval from the first left ventricular pace to a right ventricular pace (positive values indicate LV is first).
urn:iso:std:iso:11073:10101  729408MDC_IDC_SET_CRT_PACED_CHAMBERS

The ventricular chambers paced during CRT pacing.

urn:iso:std:iso:11073:10101  729472MDC_IDC_SET_MAGNET_RESP

A description of how the device responds to a magnet.

urn:iso:std:iso:11073:10101  729536MDC_IDC_SET_LEADCHNL_RA_SENSING_SENSITIVITY

The smallest electrical signal programmed to be detected by the device's sensing circuitry.

urn:iso:std:iso:11073:10101  729537MDC_IDC_SET_LEADCHNL_RV_SENSING_SENSITIVITY

The smallest electrical signal programmed to be detected by the device's sensing circuitry.

urn:iso:std:iso:11073:10101  729538MDC_IDC_SET_LEADCHNL_LA_SENSING_SENSITIVITY

The smallest electrical signal programmed to be detected by the device's sensing circuitry.

urn:iso:std:iso:11073:10101  729539MDC_IDC_SET_LEADCHNL_LV_SENSING_SENSITIVITY

The smallest electrical signal programmed to be detected by the device's sensing circuitry.

urn:iso:std:iso:11073:10101  729540MDC_IDC_SET_LEADCHNL_MIXED_SENSING_SENSITIVITY

The smallest electrical signal programmed to be detected by the device's sensing circuitry.

urn:iso:std:iso:11073:10101  729600MDC_IDC_SET_LEADCHNL_RA_SENSING_POLARITY

The indication of unipolar or bipolar configuration for sensing.

urn:iso:std:iso:11073:10101  729601MDC_IDC_SET_LEADCHNL_RV_SENSING_POLARITY

The indication of unipolar or bipolar configuration for sensing.

urn:iso:std:iso:11073:10101  729602MDC_IDC_SET_LEADCHNL_LA_SENSING_POLARITY

The indication of unipolar or bipolar configuration for sensing.

urn:iso:std:iso:11073:10101  729603MDC_IDC_SET_LEADCHNL_LV_SENSING_POLARITY

The indication of unipolar or bipolar configuration for sensing.

urn:iso:std:iso:11073:10101  729604MDC_IDC_SET_LEADCHNL_MIXED_SENSING_POLARITY

The indication of unipolar or bipolar configuration for sensing.

urn:iso:std:iso:11073:10101  729664MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_LOCATION

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729665MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_LOCATION_1

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729666MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_LOCATION_2

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729667MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_LOCATION_3

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729668MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_LOCATION

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729669MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_LOCATION_1

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729670MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_LOCATION_2

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729671MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_LOCATION_3

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729672MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_LOCATION

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729673MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_LOCATION_1

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729674MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_LOCATION_2

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729675MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_LOCATION_3

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729676MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_LOCATION

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729677MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_LOCATION_1

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729678MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_LOCATION_2

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729679MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_LOCATION_3

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729680MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_LOCATION

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729681MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_LOCATION_1

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729682MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_LOCATION_2

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729683MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_LOCATION_3

The location of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729728MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_ELECTRODE

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729729MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729730MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729731MDC_IDC_SET_LEADCHNL_RA_SENSING_ANODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729732MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_ELECTRODE

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729733MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729734MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729735MDC_IDC_SET_LEADCHNL_RV_SENSING_ANODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729736MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_ELECTRODE

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729737MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729738MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729739MDC_IDC_SET_LEADCHNL_LA_SENSING_ANODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729740MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_ELECTRODE

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729741MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729742MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729743MDC_IDC_SET_LEADCHNL_LV_SENSING_ANODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729744MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_ELECTRODE

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729745MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729746MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729747MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ANODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's anode, noting that sensing is polarity neutral. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729792MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_LOCATION

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729793MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_LOCATION_1

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729794MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_LOCATION_2

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729795MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_LOCATION_3

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729796MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_LOCATION

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729797MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_LOCATION_1

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729798MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_LOCATION_2

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729799MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_LOCATION_3

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729800MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_LOCATION

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729801MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_LOCATION_1

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729802MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_LOCATION_2

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729803MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_LOCATION_3

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729804MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_LOCATION

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729805MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_LOCATION_1

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729806MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_LOCATION_2

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729807MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_LOCATION_3

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729808MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_LOCATION

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729809MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_LOCATION_1

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729810MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_LOCATION_2

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729811MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_LOCATION_3

The location of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729856MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_ELECTRODE

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729857MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729858MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729859MDC_IDC_SET_LEADCHNL_RA_SENSING_CATHODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729860MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_ELECTRODE

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729861MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729862MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729863MDC_IDC_SET_LEADCHNL_RV_SENSING_CATHODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729864MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_ELECTRODE

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729865MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729866MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729867MDC_IDC_SET_LEADCHNL_LA_SENSING_CATHODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729868MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_ELECTRODE

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729869MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729870MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729871MDC_IDC_SET_LEADCHNL_LV_SENSING_CATHODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729872MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_ELECTRODE

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729873MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_ELECTRODE_1

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729874MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_ELECTRODE_2

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729875MDC_IDC_SET_LEADCHNL_MIXED_SENSING_CATHODE_ELECTRODE_3

The type of the electrodes that define the sensing vector's cathode, noting that sensing is polarity neutral. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  729920MDC_IDC_SET_LEADCHNL_RA_SENSING_ADAPTATION_MODE

Specifies whether the sensitivity is fixed or adapting.

urn:iso:std:iso:11073:10101  729921MDC_IDC_SET_LEADCHNL_RV_SENSING_ADAPTATION_MODE

Specifies whether the sensitivity is fixed or adapting.

urn:iso:std:iso:11073:10101  729922MDC_IDC_SET_LEADCHNL_LA_SENSING_ADAPTATION_MODE

Specifies whether the sensitivity is fixed or adapting.

urn:iso:std:iso:11073:10101  729923MDC_IDC_SET_LEADCHNL_LV_SENSING_ADAPTATION_MODE

Specifies whether the sensitivity is fixed or adapting.

urn:iso:std:iso:11073:10101  729924MDC_IDC_SET_LEADCHNL_MIXED_SENSING_ADAPTATION_MODE

Specifies whether the sensitivity is fixed or adapting.

urn:iso:std:iso:11073:10101  729984MDC_IDC_SET_LEADCHNL_RA_PACING_AMPLITUDE

The pacing output amplitude.

urn:iso:std:iso:11073:10101  729985MDC_IDC_SET_LEADCHNL_RV_PACING_AMPLITUDE

The pacing output amplitude.

urn:iso:std:iso:11073:10101  729986MDC_IDC_SET_LEADCHNL_LA_PACING_AMPLITUDE

The pacing output amplitude.

urn:iso:std:iso:11073:10101  729987MDC_IDC_SET_LEADCHNL_LV_PACING_AMPLITUDE

The pacing output amplitude.

urn:iso:std:iso:11073:10101  729988MDC_IDC_SET_LEADCHNL_MIXED_PACING_AMPLITUDE

The pacing output amplitude.

urn:iso:std:iso:11073:10101  730048MDC_IDC_SET_LEADCHNL_RA_PACING_PULSEWIDTH

The pacing output pulse width.

urn:iso:std:iso:11073:10101  730049MDC_IDC_SET_LEADCHNL_RV_PACING_PULSEWIDTH

The pacing output pulse width.

urn:iso:std:iso:11073:10101  730050MDC_IDC_SET_LEADCHNL_LA_PACING_PULSEWIDTH

The pacing output pulse width.

urn:iso:std:iso:11073:10101  730051MDC_IDC_SET_LEADCHNL_LV_PACING_PULSEWIDTH

The pacing output pulse width.

urn:iso:std:iso:11073:10101  730052MDC_IDC_SET_LEADCHNL_MIXED_PACING_PULSEWIDTH

The pacing output pulse width.

urn:iso:std:iso:11073:10101  730112MDC_IDC_SET_LEADCHNL_RA_PACING_POLARITY

The indication of unipolar or bipolar configuration for pacing.

urn:iso:std:iso:11073:10101  730113MDC_IDC_SET_LEADCHNL_RV_PACING_POLARITY

The indication of unipolar or bipolar configuration for pacing.

urn:iso:std:iso:11073:10101  730114MDC_IDC_SET_LEADCHNL_LA_PACING_POLARITY

The indication of unipolar or bipolar configuration for pacing.

urn:iso:std:iso:11073:10101  730115MDC_IDC_SET_LEADCHNL_LV_PACING_POLARITY

The indication of unipolar or bipolar configuration for pacing.

urn:iso:std:iso:11073:10101  730116MDC_IDC_SET_LEADCHNL_MIXED_PACING_POLARITY

The indication of unipolar or bipolar configuration for pacing.

urn:iso:std:iso:11073:10101  730176MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_LOCATION

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730177MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_LOCATION_1

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730178MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_LOCATION_2

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730179MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_LOCATION_3

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730180MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_LOCATION

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730181MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_LOCATION_1

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730182MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_LOCATION_2

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730183MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_LOCATION_3

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730184MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_LOCATION

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730185MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_LOCATION_1

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730186MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_LOCATION_2

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730187MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_LOCATION_3

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730188MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_LOCATION

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730189MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_LOCATION_1

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730190MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_LOCATION_2

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730191MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_LOCATION_3

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730192MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_LOCATION

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730193MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_LOCATION_1

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730194MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_LOCATION_2

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730195MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_LOCATION_3

The location of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730240MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ELECTRODE

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730241MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730242MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730243MDC_IDC_SET_LEADCHNL_RA_PACING_ANODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730244MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ELECTRODE

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730245MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730246MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730247MDC_IDC_SET_LEADCHNL_RV_PACING_ANODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730248MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_ELECTRODE

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730249MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730250MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730251MDC_IDC_SET_LEADCHNL_LA_PACING_ANODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730252MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ELECTRODE

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730253MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730254MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730255MDC_IDC_SET_LEADCHNL_LV_PACING_ANODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730256MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_ELECTRODE

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730257MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730258MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730259MDC_IDC_SET_LEADCHNL_MIXED_PACING_ANODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's anode. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730304MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_LOCATION

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730305MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_LOCATION_1

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730306MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_LOCATION_2

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730307MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_LOCATION_3

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730308MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_LOCATION

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730309MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_LOCATION_1

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730310MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_LOCATION_2

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730311MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_LOCATION_3

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730312MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_LOCATION

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730313MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_LOCATION_1

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730314MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_LOCATION_2

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730315MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_LOCATION_3

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730316MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_LOCATION

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730317MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_LOCATION_1

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730318MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_LOCATION_2

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730319MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_LOCATION_3

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730320MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_LOCATION

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730321MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_LOCATION_1

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730322MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_LOCATION_2

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730323MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_LOCATION_3

The location of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730368MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_ELECTRODE

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730369MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730370MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730371MDC_IDC_SET_LEADCHNL_RA_PACING_CATHODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730372MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_ELECTRODE

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730373MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730374MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730375MDC_IDC_SET_LEADCHNL_RV_PACING_CATHODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730376MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_ELECTRODE

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730377MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730378MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730379MDC_IDC_SET_LEADCHNL_LA_PACING_CATHODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730380MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_ELECTRODE

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730381MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730382MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730383MDC_IDC_SET_LEADCHNL_LV_PACING_CATHODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730384MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_ELECTRODE

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730385MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_ELECTRODE_1

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730386MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_ELECTRODE_2

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730387MDC_IDC_SET_LEADCHNL_MIXED_PACING_CATHODE_ELECTRODE_3

The type of the electrodes that define the pacing vector's cathode. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730432MDC_IDC_SET_LEADCHNL_RA_PACING_CAPTURE_MODE

The method the device uses for managing pacing capture.

urn:iso:std:iso:11073:10101  730433MDC_IDC_SET_LEADCHNL_RV_PACING_CAPTURE_MODE

The method the device uses for managing pacing capture.

urn:iso:std:iso:11073:10101  730434MDC_IDC_SET_LEADCHNL_LA_PACING_CAPTURE_MODE

The method the device uses for managing pacing capture.

urn:iso:std:iso:11073:10101  730435MDC_IDC_SET_LEADCHNL_LV_PACING_CAPTURE_MODE

The method the device uses for managing pacing capture.

urn:iso:std:iso:11073:10101  730436MDC_IDC_SET_LEADCHNL_MIXED_PACING_CAPTURE_MODE

The method the device uses for managing pacing capture.

urn:iso:std:iso:11073:10101  730496MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_LOCATION

The location of the anode electrode that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730497MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_LOCATION_1

The location of the anode electrode that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730498MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_LOCATION_2

The location of the anode electrode that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730499MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_LOCATION_3

The location of the anode electrode that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730560MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_ELECTRODE

The anode electrode terminal that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730561MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_ELECTRODE_1

The anode electrode terminal that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730562MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_ELECTRODE_2

The anode electrode terminal that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730563MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_ANODE_ELECTRODE_3

The anode electrode terminal that defines the shocking vector for the lead. An anode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730624MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_LOCATION

The location of the cathode electrode that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730625MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_LOCATION_1

The location of the cathode electrode that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730626MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_LOCATION_2

The location of the cathode electrode that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730627MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_LOCATION_3

The location of the cathode electrode that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730688MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_ELECTRODE

The cathode electrode terminal that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730689MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_ELECTRODE_1

The cathode electrode terminal that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730690MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_ELECTRODE_2

The cathode electrode terminal that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730691MDC_IDC_SET_LEADHVCHNL_SHOCK_VECTOR_CATHODE_ELECTRODE_3

The cathode electrode terminal that defines the shocking vector for the lead. A cathode may consist of more than one electrode.

urn:iso:std:iso:11073:10101  730752MDC_IDC_SET_BRADY_MODE

The brady pacing mode according to the NBG standard.

urn:iso:std:iso:11073:10101  730816MDC_IDC_SET_BRADY_VENDOR_MODE
  1. The brady pacing mode as defined by vendor specific codes.
  2. The brady pacing mode as defined by vendor-specific codes.
urn:iso:std:iso:11073:10101  730880MDC_IDC_SET_BRADY_LOWRATE

The rate at which the device paces in the absence of a cardiac rhythm faster than the lower rate and without influence from features that can affect the pacing rate.

urn:iso:std:iso:11073:10101  730944MDC_IDC_SET_BRADY_HYSTRATE

The lower rate for the hysteresis feature.

urn:iso:std:iso:11073:10101  731008MDC_IDC_SET_BRADY_NIGHT_RATE

The lower rate for the night rate feature.

urn:iso:std:iso:11073:10101  731072MDC_IDC_SET_BRADY_SENSOR_TYPE

The type of sensor applied for rate adaptive pacing.

urn:iso:std:iso:11073:10101  731136MDC_IDC_SET_BRADY_MAX_TRACKING_RATE

The fastest atrial rate at which ventricular pacing occurs with 1:1 synchrony.

urn:iso:std:iso:11073:10101  731200MDC_IDC_SET_BRADY_MAX_SENSOR_RATE

The fastest sensor-driven pacing rate that can be achieved in a rate-adaptive pacing system.

urn:iso:std:iso:11073:10101  731264MDC_IDC_SET_BRADY_SAV_DELAY

The interval from an intrinsic (sensed) P wave to a paced ventricular event.

urn:iso:std:iso:11073:10101  731265MDC_IDC_SET_BRADY_SAV_DELAY_HIGH

The interval from an intrinsic (sensed) P wave to a paced ventricular event.

urn:iso:std:iso:11073:10101  731266MDC_IDC_SET_BRADY_SAV_DELAY_LOW

The interval from an intrinsic (sensed) P wave to a paced ventricular event.

urn:iso:std:iso:11073:10101  731328MDC_IDC_SET_BRADY_PAV_DELAY
  1. The interval from a paced atrial event to a paced ventricular event.
  2. The interval from a paced right atrial event to the first ventricular paced event.
urn:iso:std:iso:11073:10101  731329MDC_IDC_SET_BRADY_PAV_DELAY_HIGH
  1. The interval from a paced atrial event to a paced ventricular event.
  2. The interval from a paced right atrial event to the first ventricular paced event.
urn:iso:std:iso:11073:10101  731330MDC_IDC_SET_BRADY_PAV_DELAY_LOW
  1. The interval from a paced atrial event to a paced ventricular event.
  2. The interval from a paced right atrial event to the first ventricular paced event.
urn:iso:std:iso:11073:10101  731392MDC_IDC_SET_BRADY_AT_MODE_SWITCH_MODE

The atrial tachycardia mode switch mode.

urn:iso:std:iso:11073:10101  731456MDC_IDC_SET_BRADY_AT_MODE_SWITCH_RATE

The atrial tachycardia mode switch rate.

urn:iso:std:iso:11073:10101  731520MDC_IDC_SET_TACHYTHERAPY_VSTAT
  1. The high level programmed status for ventricular tachy therapies.
  2. The high-level programmed status for ventricular tachy therapies.
urn:iso:std:iso:11073:10101  731584MDC_IDC_SET_TACHYTHERAPY_ASTAT
  1. The high level programmed status for atrial tachy therapies.
  2. The high-level programmed status for atrial tachy therapies.
urn:iso:std:iso:11073:10101  731648MDC_IDC_SET_ZONE_TYPE

The general type of the zone for tachy therapy detection.

urn:iso:std:iso:11073:10101  731712MDC_IDC_SET_ZONE_VENDOR_TYPE
  1. The vendor specific type of the zone for tachy therapy detection.
  2. The vendor-specific type of the zone for tachy therapy detection.
urn:iso:std:iso:11073:10101  731776MDC_IDC_SET_ZONE_STATUS
  1. The status of the zone, whether it is is active or not.
  2. The status of the zone, whether it is active or not.
urn:iso:std:iso:11073:10101  731840MDC_IDC_SET_ZONE_DETECTION_INTERVAL

The upper interval limit of the zone for tachy therapy detection.

urn:iso:std:iso:11073:10101  731904MDC_IDC_SET_ZONE_DETECTION_BEATS_NUMERATOR

The numerator portion of the tachy detection ratio.

urn:iso:std:iso:11073:10101  731968MDC_IDC_SET_ZONE_DETECTION_BEATS_DENOMINATOR

The denominator portion of the tachy detection ratio.

urn:iso:std:iso:11073:10101  732032MDC_IDC_SET_ZONE_DETECTION_DETAILS

A text describing arrhythmia detection details.

urn:iso:std:iso:11073:10101  732096MDC_IDC_SET_ZONE_TYPE_ATP
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732097MDC_IDC_SET_ZONE_TYPE_ATP_1
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732098MDC_IDC_SET_ZONE_TYPE_ATP_2
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732099MDC_IDC_SET_ZONE_TYPE_ATP_3
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732100MDC_IDC_SET_ZONE_TYPE_ATP_4
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732101MDC_IDC_SET_ZONE_TYPE_ATP_5
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732102MDC_IDC_SET_ZONE_TYPE_ATP_6
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732103MDC_IDC_SET_ZONE_TYPE_ATP_7
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732104MDC_IDC_SET_ZONE_TYPE_ATP_8
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732105MDC_IDC_SET_ZONE_TYPE_ATP_9
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732106MDC_IDC_SET_ZONE_TYPE_ATP_10
  1. The type of anti-tachycardia pacing (ATP) sequences programmed per ATP type.
  2. The type of antitachycardia pacing (ATP) sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732160MDC_IDC_SET_ZONE_NUM_ATP_SEQS
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732161MDC_IDC_SET_ZONE_NUM_ATP_SEQS_1
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732162MDC_IDC_SET_ZONE_NUM_ATP_SEQS_2
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732163MDC_IDC_SET_ZONE_NUM_ATP_SEQS_3
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732164MDC_IDC_SET_ZONE_NUM_ATP_SEQS_4
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732165MDC_IDC_SET_ZONE_NUM_ATP_SEQS_5
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732166MDC_IDC_SET_ZONE_NUM_ATP_SEQS_6
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732167MDC_IDC_SET_ZONE_NUM_ATP_SEQS_7
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732168MDC_IDC_SET_ZONE_NUM_ATP_SEQS_8
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732169MDC_IDC_SET_ZONE_NUM_ATP_SEQS_9
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732170MDC_IDC_SET_ZONE_NUM_ATP_SEQS_10
  1. The number of anti-tachycardia pacing pulse (ATP) sequences programmed per ATP type.
  2. The number of antitachycardia pacing (ATP) pulse sequences programmed per ATP type.
urn:iso:std:iso:11073:10101  732224MDC_IDC_SET_ZONE_SHOCK_ENERGY

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732225MDC_IDC_SET_ZONE_SHOCK_ENERGY_1

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732226MDC_IDC_SET_ZONE_SHOCK_ENERGY_2

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732227MDC_IDC_SET_ZONE_SHOCK_ENERGY_3

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732228MDC_IDC_SET_ZONE_SHOCK_ENERGY_4

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732229MDC_IDC_SET_ZONE_SHOCK_ENERGY_5

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732230MDC_IDC_SET_ZONE_SHOCK_ENERGY_6

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732231MDC_IDC_SET_ZONE_SHOCK_ENERGY_7

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732232MDC_IDC_SET_ZONE_SHOCK_ENERGY_8

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732233MDC_IDC_SET_ZONE_SHOCK_ENERGY_9

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732234MDC_IDC_SET_ZONE_SHOCK_ENERGY_10

The shock energy delivered at a particular sequence of a zone therapy.

urn:iso:std:iso:11073:10101  732288MDC_IDC_SET_ZONE_NUM_SHOCKS

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732289MDC_IDC_SET_ZONE_NUM_SHOCKS_1

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732290MDC_IDC_SET_ZONE_NUM_SHOCKS_2

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732291MDC_IDC_SET_ZONE_NUM_SHOCKS_3

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732292MDC_IDC_SET_ZONE_NUM_SHOCKS_4

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732293MDC_IDC_SET_ZONE_NUM_SHOCKS_5

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732294MDC_IDC_SET_ZONE_NUM_SHOCKS_6

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732295MDC_IDC_SET_ZONE_NUM_SHOCKS_7

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732296MDC_IDC_SET_ZONE_NUM_SHOCKS_8

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732297MDC_IDC_SET_ZONE_NUM_SHOCKS_9

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  732298MDC_IDC_SET_ZONE_NUM_SHOCKS_10

The maximum number of shocks set to be delivered at the given shock energy.

urn:iso:std:iso:11073:10101  737488MDC_IDC_STAT_DTM

The date and time period for the aggregated statistics.

urn:iso:std:iso:11073:10101  737489MDC_IDC_STAT_DTM_START

The date and time period for the aggregated statistics.

urn:iso:std:iso:11073:10101  737490MDC_IDC_STAT_DTM_END

The date and time period for the aggregated statistics.

urn:iso:std:iso:11073:10101  737504MDC_IDC_STAT_BRADY_DTM

The date time period of the brady statistics.

urn:iso:std:iso:11073:10101  737505MDC_IDC_STAT_BRADY_DTM_START

The date time period of the brady statistics.

urn:iso:std:iso:11073:10101  737506MDC_IDC_STAT_BRADY_DTM_END

The date time period of the brady statistics.

urn:iso:std:iso:11073:10101  737520MDC_IDC_STAT_BRADY_RA_PERCENT_PACED
  1. The percentage of pacing events in the right atrial chamber over the specified time period.
  2. The percentage of pacing events in the right atrial chamber over the brady statistics time range.
urn:iso:std:iso:11073:10101  737536MDC_IDC_STAT_BRADY_RV_PERCENT_PACED
  1. The percentage of pacing events in the right ventricular chamber over the specified time period.
  2. The percentage of pacing events in the right ventricular chamber over the brady statistics time range.
urn:iso:std:iso:11073:10101  737552MDC_IDC_STAT_BRADY_AP_VP_PERCENT
  1. The percentage of atrial pace - ventricular pace sequences in relationship to all AV sequences over the specified time period.
  2. The percentage of atrial pace - ventricular pace sequences in relationship to all AV sequences over the brady statistics time range.
urn:iso:std:iso:11073:10101  737568MDC_IDC_STAT_BRADY_AS_VP_PERCENT
  1. The percentage of atrial sense - ventricular pace sequences in relationship to all AV sequences over the specified time period.
  2. The percentage of atrial sense - ventricular pace sequences in relationship to all AV sequences over the brady statistics time range.
urn:iso:std:iso:11073:10101  737584MDC_IDC_STAT_BRADY_AP_VS_PERCENT
  1. The percentage of atrial pace - ventricular sense sequences in relationship to all AV sequences over the specified time period.
  2. The percentage of atrial pace - ventricular sense sequences in relationship to all AV sequences over the brady statistics time range.
urn:iso:std:iso:11073:10101  737600MDC_IDC_STAT_BRADY_AS_VS_PERCENT
  1. The percentage of atrial sense - ventricular sense sequences in relationship to all AV sequences over the specified time period.
  2. The percentage of atrial sense - ventricular sense sequences in relationship to all AV sequences over the brady statistics time range.
urn:iso:std:iso:11073:10101  737616MDC_IDC_STAT_HEART_RATE_DTM

The date and time period for the heart rate statistics.

urn:iso:std:iso:11073:10101  737617MDC_IDC_STAT_HEART_RATE_DTM_START

The date and time period for the heart rate statistics.

urn:iso:std:iso:11073:10101  737618MDC_IDC_STAT_HEART_RATE_DTM_END

The date and time period for the heart rate statistics.

urn:iso:std:iso:11073:10101  737632MDC_IDC_STAT_HEART_RATE_ATRIAL
  1. The mean atrial heart rate over the specified time period.
  2. The atrial heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737633MDC_IDC_STAT_HEART_RATE_ATRIAL_MAX
  1. The mean atrial heart rate over the specified time period.
  2. The atrial heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737634MDC_IDC_STAT_HEART_RATE_ATRIAL_MIN
  1. The mean atrial heart rate over the specified time period.
  2. The atrial heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737635MDC_IDC_STAT_HEART_RATE_ATRIAL_MEAN
  1. The mean atrial heart rate over the specified time period.
  2. The atrial heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737648MDC_IDC_STAT_HEART_RATE_VENTRICULAR
  1. The mean ventricular heart rate over the specified time period.
  2. The ventricular heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737649MDC_IDC_STAT_HEART_RATE_VENTRICULAR_MAX
  1. The mean ventricular heart rate over the specified time period.
  2. The ventricular heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737650MDC_IDC_STAT_HEART_RATE_VENTRICULAR_MIN
  1. The mean ventricular heart rate over the specified time period.
  2. The ventricular heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737651MDC_IDC_STAT_HEART_RATE_VENTRICULAR_MEAN
  1. The mean ventricular heart rate over the specified time period.
  2. The ventricular heart rate over the heart rate statistics time range.
urn:iso:std:iso:11073:10101  737664MDC_IDC_STAT_AT_DTM

The date and time period for the AT statistics.

urn:iso:std:iso:11073:10101  737665MDC_IDC_STAT_AT_DTM_START

The date and time period for the AT statistics.

urn:iso:std:iso:11073:10101  737666MDC_IDC_STAT_AT_DTM_END

The date and time period for the AT statistics.

urn:iso:std:iso:11073:10101  737680MDC_IDC_STAT_AT_MODE_SW_MAX_DURATION
  1. The maximum contiguous time the device is in AT mode switch over the specified time period.
  2. The maximum contiguous time the device is in AT mode switch over the AT statistics time range.
urn:iso:std:iso:11073:10101  737696MDC_IDC_STAT_AT_BURDEN_PERCENT
  1. The percent of time in AT AF per day over the specified time period.
  2. The percent of time in AT AF per day over the AT statistics time range.
urn:iso:std:iso:11073:10101  737712MDC_IDC_STAT_AT_MODE_SW_PERCENT_TIME
  1. The percentage of time the device is in AT mode switch over the specified time period.
  2. The percentage of time the device is in AT mode switch over the AT statistics time range.
urn:iso:std:iso:11073:10101  737728MDC_IDC_STAT_AT_MODE_SW_PERCENT_TIME_PER_DAY
  1. The percentage of time per day the device is in AT mode switch over the specified time period.
  2. The percentage of time per day the device is in AT mode switch over the AT statistics time range.
urn:iso:std:iso:11073:10101  737744MDC_IDC_STAT_AT_MODE_SW_COUNT
  1. The number of mode switches over the specified time period.
  2. The number of mode switches over the AT statistics time range.
urn:iso:std:iso:11073:10101  737760MDC_IDC_STAT_AT_MODE_SW_COUNT_PER_DAY
  1. The average number of mode switches per day over the specified time period.
  2. The average number of mode switches per day over the AT statistics time range.
urn:iso:std:iso:11073:10101  737776MDC_IDC_STAT_CRT_DTM

The date and time period for the CRT statistics.

urn:iso:std:iso:11073:10101  737777MDC_IDC_STAT_CRT_DTM_START

The date and time period for the CRT statistics.

urn:iso:std:iso:11073:10101  737778MDC_IDC_STAT_CRT_DTM_END

The date and time period for the CRT statistics.

urn:iso:std:iso:11073:10101  737792MDC_IDC_STAT_CRT_LV_PERCENT_PACED
  1. The percentage of LV pacing events in relation to all LV events over the specified time period.
  2. The percentage of LV pacing events in relation to all LV events over the CRT statistics time range.
urn:iso:std:iso:11073:10101  737808MDC_IDC_STAT_CRT_PERCENT_PACED
  1. The percentage of LV pacing events due to CRT mode in relation to all ventricular events over the specified time period.
  2. The percentage of LV pacing events due to CRT mode in relation to all ventricular events over the CRT statistics time range.
urn:iso:std:iso:11073:10101  737824MDC_IDC_STAT_TACHYTHERAPY_SHOCKS_DELIVERED_RECENT
  1. The number of shocks applied over the specified time period.
  2. The number of shocks delivered, for the tachy therapy recent statistics time range.
urn:iso:std:iso:11073:10101  737840MDC_IDC_STAT_TACHYTHERAPY_SHOCKS_DELIVERED_TOTAL
  1. The total number of shocks applied since implantation or device reset.
  2. The total number of shocks delivered since implantation or device reset, for the tachy therapy total statistics time range.
urn:iso:std:iso:11073:10101  737856MDC_IDC_STAT_TACHYTHERAPY_SHOCKS_ABORTED_RECENT
  1. The number of shocks aborted over the specified time period.
  2. The number of shocks initiated but not delivered, for the tachy therapy recent statistics time range.
urn:iso:std:iso:11073:10101  737872MDC_IDC_STAT_TACHYTHERAPY_SHOCKS_ABORTED_TOTAL
  1. The total number of shocks aborted since implantation or device reset.
  2. The total number of shocks initiated but not delivered, for the tachy therapy total statistics time range.
urn:iso:std:iso:11073:10101  737888MDC_IDC_STAT_TACHYTHERAPY_ATP_DELIVERED_RECENT
  1. The number of anti-tachycardia pacing (ATP) sequences delivered over the specified time period.
  2. The number of anti-tachycardia pacing (ATP) sequences delivered, for the tachy therapy recent statistics time range.
urn:iso:std:iso:11073:10101  737904MDC_IDC_STAT_TACHYTHERAPY_ATP_DELIVERED_TOTAL
  1. The total number of anti-tachycardia pacing (ATP) sequences delivered since implantation or device reset.
  2. The total number of anti-tachycardia pacing (ATP) sequences delivered, for the tachy therapy total statistics time range.
urn:iso:std:iso:11073:10101  737920MDC_IDC_STAT_TACHYTHERAPY_TOTAL_DTM
  1. The date and time period for the total tachy therapy statistics.
  2. The date and time range for the total tachy therapy statistics.
urn:iso:std:iso:11073:10101  737921MDC_IDC_STAT_TACHYTHERAPY_TOTAL_DTM_START
  1. The date and time period for the total tachy therapy statistics.
  2. The date and time range for the total tachy therapy statistics.
urn:iso:std:iso:11073:10101  737922MDC_IDC_STAT_TACHYTHERAPY_TOTAL_DTM_END
  1. The date and time period for the total tachy therapy statistics.
  2. The date and time range for the total tachy therapy statistics.
urn:iso:std:iso:11073:10101  737936MDC_IDC_STAT_TACHYTHERAPY_RECENT_DTM
  1. The date and time period for the recent tachy therapy statistics.
  2. The date and time range for the recent tachy therapy statistics.
urn:iso:std:iso:11073:10101  737937MDC_IDC_STAT_TACHYTHERAPY_RECENT_DTM_START
  1. The date and time period for the recent tachy therapy statistics.
  2. The date and time range for the recent tachy therapy statistics.
urn:iso:std:iso:11073:10101  737938MDC_IDC_STAT_TACHYTHERAPY_RECENT_DTM_END
  1. The date and time period for the recent tachy therapy statistics.
  2. The date and time range for the recent tachy therapy statistics.
urn:iso:std:iso:11073:10101  737952MDC_IDC_STAT_EPISODE_TYPE

The generic type of the episode being reported.

urn:iso:std:iso:11073:10101  737968MDC_IDC_STAT_EPISODE_TYPE_INDUCED

The indication of whether the episode has been induced or not.

urn:iso:std:iso:11073:10101  737984MDC_IDC_STAT_EPISODE_VENDOR_TYPE

The vendor type of the episode being reported.

urn:iso:std:iso:11073:10101  738000MDC_IDC_STAT_EPISODE_RECENT_COUNT
  1. The number of episodes per episode type over the specified time period.
  2. The number of episodes per episode type, for the episode recent count statistics time range.
urn:iso:std:iso:11073:10101  738016MDC_IDC_STAT_EPISODE_RECENT_COUNT_DTM

The date and time period for the recent episode counts.

urn:iso:std:iso:11073:10101  738017MDC_IDC_STAT_EPISODE_RECENT_COUNT_DTM_START

The date and time period for the recent episode counts.

urn:iso:std:iso:11073:10101  738018MDC_IDC_STAT_EPISODE_RECENT_COUNT_DTM_END

The date and time period for the recent episode counts.

urn:iso:std:iso:11073:10101  738032MDC_IDC_STAT_EPISODE_TOTAL_COUNT
  1. The number of episodes per episode type since implantation or device reset.
  2. The number of episodes per episode type since implantation or device reset, for the episode total count statistics time range.
urn:iso:std:iso:11073:10101  738048MDC_IDC_STAT_EPISODE_TOTAL_COUNT_DTM

The date and time period for the total episode counts.

urn:iso:std:iso:11073:10101  738049MDC_IDC_STAT_EPISODE_TOTAL_COUNT_DTM_START

The date and time period for the total episode counts.

urn:iso:std:iso:11073:10101  738050MDC_IDC_STAT_EPISODE_TOTAL_COUNT_DTM_END

The date and time period for the total episode counts.

urn:iso:std:iso:11073:10101  739536MDC_IDC_EPISODE_ID

The unique identifier for the episode.

urn:iso:std:iso:11073:10101  739552MDC_IDC_EPISODE_DTM

The detection date and time of the episode.

urn:iso:std:iso:11073:10101  739568MDC_IDC_EPISODE_TYPE

The generic type of the episode being reported.

urn:iso:std:iso:11073:10101  739584MDC_IDC_EPISODE_TYPE_INDUCED

The indication of whether the episode has been induced or not.

urn:iso:std:iso:11073:10101  739600MDC_IDC_EPISODE_VENDOR_TYPE

The vendor type of the episode being reported.

urn:iso:std:iso:11073:10101  739616MDC_IDC_EPISODE_ATRIAL_INTERVAL_AT_DETECTION

The atrial interval at the time of detection.

urn:iso:std:iso:11073:10101  739632MDC_IDC_EPISODE_ATRIAL_INTERVAL_AT_TERMINATION

The atrial interval at the time of termination.

urn:iso:std:iso:11073:10101  739648MDC_IDC_EPISODE_VENTRICULAR_INTERVAL_AT_DETECTION

The ventricular interval at the time of detection.

urn:iso:std:iso:11073:10101  739664MDC_IDC_EPISODE_VENTRICULAR_INTERVAL_AT_TERMINATION

The ventricular interval at the time of termination.

urn:iso:std:iso:11073:10101  739680MDC_IDC_EPISODE_DETECTION_THERAPY_DETAILS

A text describing details about the detection and therapy delivered.

urn:iso:std:iso:11073:10101  739696MDC_IDC_EPISODE_THERAPY_RESULT

The indicator of therapy success.

urn:iso:std:iso:11073:10101  739712MDC_IDC_EPISODE_DURATION

The duration of the episode in seconds.

urn:iso:std:iso:11073:10101  753665MDC_IDC_ENUM_DEV_TYPE_IPG

A battery powered implantable device that uses low voltage pulses to stimulate the heart when it is beating too slow.

urn:iso:std:iso:11073:10101  753666MDC_IDC_ENUM_DEV_TYPE_ICD

A battery powered implantable device that uses high voltage energy to shock the heart when it is beating too fast and mostly includes pacemaker functionality.

urn:iso:std:iso:11073:10101  753667MDC_IDC_ENUM_DEV_TYPE_CRT_D

A battery powered implantable device that uses low voltage pulses to stimulate the ventricles of the heart in multiple locations to increase blood pumping efficiency and also includes pacemaker and defibrillator functionality.

urn:iso:std:iso:11073:10101  753668MDC_IDC_ENUM_DEV_TYPE_CRT_P

A battery powered implantable device that uses low voltage pulses to stimulate the ventricles of the heart in multiple locations to increase blood pumping efficiency and also includes pacemaker functionality.

urn:iso:std:iso:11073:10101  753669MDC_IDC_ENUM_DEV_TYPE_Monitor

A battery powered implantable device that monitors and records cardiac activity and does not deliver any therapy.

urn:iso:std:iso:11073:10101  753670MDC_IDC_ENUM_DEV_TYPE_Other

A device type other than those included in the nomenclature.

urn:iso:std:iso:11073:10101  753729MDC_IDC_ENUM_MFG_ANGN

A manufacturer name

urn:iso:std:iso:11073:10101  753730MDC_IDC_ENUM_MFG_APC

A manufacturer name

urn:iso:std:iso:11073:10101  753731MDC_IDC_ENUM_MFG_BIO

A manufacturer name

urn:iso:std:iso:11073:10101  753732MDC_IDC_ENUM_MFG_BSX

A manufacturer name

urn:iso:std:iso:11073:10101  753733MDC_IDC_ENUM_MFG_CCS

A manufacturer name

urn:iso:std:iso:11073:10101  753734MDC_IDC_ENUM_MFG_CIM

A manufacturer name

urn:iso:std:iso:11073:10101  753735MDC_IDC_ENUM_MFG_CPM

A manufacturer name

urn:iso:std:iso:11073:10101  753736MDC_IDC_ENUM_MFG_CKP

A manufacturer name

urn:iso:std:iso:11073:10101  753737MDC_IDC_ENUM_MFG_CATM

A manufacturer name

urn:iso:std:iso:11073:10101  753738MDC_IDC_ENUM_MFG_COR

A manufacturer name

urn:iso:std:iso:11073:10101  753739MDC_IDC_ENUM_MFG_ELA

A manufacturer name

urn:iso:std:iso:11073:10101  753740MDC_IDC_ENUM_MFG_GDT

A manufacturer name

urn:iso:std:iso:11073:10101  753741MDC_IDC_ENUM_MFG_IMC

A manufacturer name

urn:iso:std:iso:11073:10101  753742MDC_IDC_ENUM_MFG_IMT

A manufacturer name

urn:iso:std:iso:11073:10101  753743MDC_IDC_ENUM_MFG_MCO

A manufacturer name

urn:iso:std:iso:11073:10101  753744MDC_IDC_ENUM_MFG_MDT

A manufacturer name

urn:iso:std:iso:11073:10101  753745MDC_IDC_ENUM_MFG_OSC

A manufacturer name

urn:iso:std:iso:11073:10101  753746MDC_IDC_ENUM_MFG_OSY

A manufacturer name

urn:iso:std:iso:11073:10101  753747MDC_IDC_ENUM_MFG_PCS

A manufacturer name

urn:iso:std:iso:11073:10101  753748MDC_IDC_ENUM_MFG_SIE

A manufacturer name

urn:iso:std:iso:11073:10101  753749MDC_IDC_ENUM_MFG_SOM

A manufacturer name

urn:iso:std:iso:11073:10101  753750MDC_IDC_ENUM_MFG_SOR

A manufacturer name

urn:iso:std:iso:11073:10101  753751MDC_IDC_ENUM_MFG_STJ

A manufacturer name

urn:iso:std:iso:11073:10101  753752MDC_IDC_ENUM_MFG_STO

A manufacturer name

urn:iso:std:iso:11073:10101  753753MDC_IDC_ENUM_MFG_TEL

A manufacturer name

urn:iso:std:iso:11073:10101  753754MDC_IDC_ENUM_MFG_VEN

A manufacturer name

urn:iso:std:iso:11073:10101  753755MDC_IDC_ENUM_MFG_VIT

A manufacturer name

urn:iso:std:iso:11073:10101  753756MDC_IDC_ENUM_MFG_Other

A manufacturer other than that contained in the current nomenclature.

urn:iso:std:iso:11073:10101  753793MDC_IDC_ENUM_LEAD_POLARITY_TYPE_UNI

A lead with a single electrode.

urn:iso:std:iso:11073:10101  753794MDC_IDC_ENUM_LEAD_POLARITY_TYPE_BI

A lead with a two electrodes.

urn:iso:std:iso:11073:10101  753795MDC_IDC_ENUM_LEAD_POLARITY_TYPE_TRI

A lead with a three electrodes.

urn:iso:std:iso:11073:10101  753796MDC_IDC_ENUM_LEAD_POLARITY_TYPE_QUAD

A lead with a four electrodes.

urn:iso:std:iso:11073:10101  753797MDC_IDC_ENUM_LEAD_POLARITY_TYPE_MULTI

A lead with more than four electrodes.

urn:iso:std:iso:11073:10101  753798MDC_IDC_ENUM_LEAD_POLARITY_TYPE_Unknown

An indicator showing that polarity type is unknown for the lead.

urn:iso:std:iso:11073:10101  753857MDC_IDC_ENUM_LEAD_LOCATION_CHAMBER_LA

The left atrium of the heart.

urn:iso:std:iso:11073:10101  753858MDC_IDC_ENUM_LEAD_LOCATION_CHAMBER_LV

The left ventricle of the heart.

urn:iso:std:iso:11073:10101  753859MDC_IDC_ENUM_LEAD_LOCATION_CHAMBER_RA

The right atrium of the heart.

urn:iso:std:iso:11073:10101  753860MDC_IDC_ENUM_LEAD_LOCATION_CHAMBER_RV

The right ventricle of the heart.

urn:iso:std:iso:11073:10101  753861MDC_IDC_ENUM_LEAD_LOCATION_CHAMBER_OTHER

A location other than the heart chambers.

urn:iso:std:iso:11073:10101  753862MDC_IDC_ENUM_LEAD_LOCATION_CHAMBER_Unknown

An indicator showing that the lead location is unknown for the lead.

urn:iso:std:iso:11073:10101  753921MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Anterior

The front of the heart or further descriptor of the cardiac veins.

urn:iso:std:iso:11073:10101  753922MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Apex

The highest or lowest physical location in a heart chamber.

urn:iso:std:iso:11073:10101  753923MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Appendage

A muscular pouch in the left atrium of the heart.

urn:iso:std:iso:11073:10101  753924MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_CardiacVein

The cardiac vein of the heart.

urn:iso:std:iso:11073:10101  753925MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_VenaCava

The vena cava of the heart.

urn:iso:std:iso:11073:10101  753926MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_CoronarySinus

A specific cardiac vein of the heart.

urn:iso:std:iso:11073:10101  753927MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Distal

A location furthest from a specified reference.

urn:iso:std:iso:11073:10101  753928MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Epicardial

The outside surface of the heart.

urn:iso:std:iso:11073:10101  753929MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_FreeWall

A further detail for a location within the heart.

urn:iso:std:iso:11073:10101  753930MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Great

A further descriptor of the cardiac veins.

urn:iso:std:iso:11073:10101  753931MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_High

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753932MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Lateral

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753933MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Left

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753934MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Low

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753935MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Marginal

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753936MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Middle

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753937MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Myocardial

The muscle tissue of the heart.

urn:iso:std:iso:11073:10101  753938MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_OutflowTract

The part of the left ventricle where the blood exits through the pulmonary artery.

urn:iso:std:iso:11073:10101  753939MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Posterior

The back of the heart or further descriptor of the cardiac veins.

urn:iso:std:iso:11073:10101  753940MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Proximal

A location nearest to a specified reference.

urn:iso:std:iso:11073:10101  753941MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Right

A further descriptor for a location within the heart.

urn:iso:std:iso:11073:10101  753942MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Septum

The walls that separate the chambers of the heart.

urn:iso:std:iso:11073:10101  753943MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Subclavian

A major artery connected to the heart.

urn:iso:std:iso:11073:10101  753944MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Subcutaneous

A location under the skin.

urn:iso:std:iso:11073:10101  753945MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Superior

A specific cardiac vein of the heart.

urn:iso:std:iso:11073:10101  753946MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_HISbundle

The electrical fibers in the heart, inside the septum between the left and right ventricles.

urn:iso:std:iso:11073:10101  753947MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Other

A location other than that which is contained in current nomenclature.

urn:iso:std:iso:11073:10101  753948MDC_IDC_ENUM_LEAD_LOCATION_DETAIL_Unknown

An indicator showing that the lead location detail is unknown for the lead.

urn:iso:std:iso:11073:10101  753985MDC_IDC_ENUM_LEAD_STATUS_Connected

An indicator that a cardiac lead is functional and in use.

urn:iso:std:iso:11073:10101  753986MDC_IDC_ENUM_LEAD_STATUS_Abandoned

An indicator that a cardiac lead is non-functional and not in use.

urn:iso:std:iso:11073:10101  754049MDC_IDC_ENUM_SESS_TYPE_Implant

An indicator that the data was acquired at the time of the surgical implant.

urn:iso:std:iso:11073:10101  754050MDC_IDC_ENUM_SESS_TYPE_InClinic

An indicator that the data was acquired when the patient was in a hospital or clinic.

urn:iso:std:iso:11073:10101  754051MDC_IDC_ENUM_SESS_TYPE_Remote

An indicator that the data was acquired while the patient was outside a hospital or clinic.

urn:iso:std:iso:11073:10101  754052MDC_IDC_ENUM_SESS_TYPE_RemoteDeviceInitiated

An indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and because of a condition the device detected.

urn:iso:std:iso:11073:10101  754053MDC_IDC_ENUM_SESS_TYPE_RemoteScheduled

An indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and at a time that was planned in advance.

urn:iso:std:iso:11073:10101  754054MDC_IDC_ENUM_SESS_TYPE_RemotePatientInitiated

An indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and because of an action by the patient at a time that was not planned in advance.

urn:iso:std:iso:11073:10101  754055MDC_IDC_ENUM_SESS_TYPE_Other

An interrogation session type not currently defined within the nomenclature.

urn:iso:std:iso:11073:10101  754056MDC_IDC_ENUM_SESS_TYPE_Unknown

An indicator showing that the session type is unknown for the interrogation session.

urn:iso:std:iso:11073:10101  754113MDC_IDC_ENUM_BATTERY_STATUS_BOS

The device battery is at the beginning of its service.

urn:iso:std:iso:11073:10101  754114MDC_IDC_ENUM_BATTERY_STATUS_EOS

The device battery is depleted.

urn:iso:std:iso:11073:10101  754115MDC_IDC_ENUM_BATTERY_STATUS_RRT

An indicator that the device should be replaced.

urn:iso:std:iso:11073:10101  754116MDC_IDC_ENUM_BATTERY_STATUS_MOS

The device battery is in use but not depleted or nearing depletion.

urn:iso:std:iso:11073:10101  754117MDC_IDC_ENUM_BATTERY_STATUS_Unknown

An indicator showing that the battery status is unknown for the battery.

urn:iso:std:iso:11073:10101  754177MDC_IDC_ENUM_CHARGE_TYPE_Shock

The measurement was made when the capacitor was being charged for the purpose of delivering a high voltage shock.

urn:iso:std:iso:11073:10101  754178MDC_IDC_ENUM_CHARGE_TYPE_Reformation

The measurement was made when the capacitor was being charged for routine maintenance not involving shock delivery.

urn:iso:std:iso:11073:10101  754179MDC_IDC_ENUM_CHARGE_TYPE_Unknown

An indicator showing that the charge type is unknown for the charge.

urn:iso:std:iso:11073:10101  754241MDC_IDC_ENUM_CHANNEL_STATUS_CheckLead

A notification that the lead appears to be not functioning properly per the device vendor specific criterion.

urn:iso:std:iso:11073:10101  754242MDC_IDC_ENUM_CHANNEL_STATUS_Null

The absence of a lead status notification.

urn:iso:std:iso:11073:10101  754305MDC_IDC_ENUM_POLARITY_UNI

The lead measurement or setting is between one lead electrode and the device can.

urn:iso:std:iso:11073:10101  754306MDC_IDC_ENUM_POLARITY_BI

The lead measurement or setting is between two lead electrodes.

urn:iso:std:iso:11073:10101  754307MDC_IDC_ENUM_POLARITY_Unknown

An indicator showing that the polarity is unknown for the electrode.

urn:iso:std:iso:11073:10101  754369MDC_IDC_ENUM_MEASUREMENT_METHOD_ProgrammerManual

A manual measurement made using a programmer. The measurement was made by a clinician programming different device values and noting when changes were observed.

urn:iso:std:iso:11073:10101  754370MDC_IDC_ENUM_MEASUREMENT_METHOD_ProgrammerAutomatic

The measurement was made by a clinician using an automatic routine within the programmer.

urn:iso:std:iso:11073:10101  754371MDC_IDC_ENUM_MEASUREMENT_METHOD_DeviceAutomatic

The measurement was made by an automatic routine within the device.

urn:iso:std:iso:11073:10101  754372MDC_IDC_ENUM_MEASUREMENT_METHOD_Unknown

An indicator showing that the measurement method is unknown.

urn:iso:std:iso:11073:10101  754433MDC_IDC_ENUM_HVCHNL_MEASUREMENT_TYPE_LowVoltage

The measurement was made using voltage levels associated with a cardiac pacing pulses or lower.

urn:iso:std:iso:11073:10101  754434MDC_IDC_ENUM_HVCHNL_MEASUREMENT_TYPE_Shock

The measurement was made using high voltage energy during delivery of a shock.

urn:iso:std:iso:11073:10101  754435MDC_IDC_ENUM_HVCHNL_MEASUREMENT_TYPE_Unknown

An indicator showing that the measurement type is unknown for the high voltage channel measurement.

urn:iso:std:iso:11073:10101  754497MDC_IDC_ENUM_ELECTRODE_LOCATION_RA

The right atrium of the heart.

urn:iso:std:iso:11073:10101  754498MDC_IDC_ENUM_ELECTRODE_LOCATION_RV

The right ventricle of the heart.

urn:iso:std:iso:11073:10101  754499MDC_IDC_ENUM_ELECTRODE_LOCATION_LA

The left atrium of the heart.

urn:iso:std:iso:11073:10101  754500MDC_IDC_ENUM_ELECTRODE_LOCATION_LV

The left ventricle of the heart.

urn:iso:std:iso:11073:10101  754501MDC_IDC_ENUM_ELECTRODE_LOCATION_SVC

The superior vena cava.

urn:iso:std:iso:11073:10101  754502MDC_IDC_ENUM_ELECTRODE_LOCATION_Other

Other location.

urn:iso:std:iso:11073:10101  754503MDC_IDC_ENUM_ELECTRODE_LOCATION_Unknown

An indicator showing that the location is unknown for the electrode.

urn:iso:std:iso:11073:10101  754561MDC_IDC_ENUM_ELECTRODE_NAME_Tip

A tip electrode of the lead.

urn:iso:std:iso:11073:10101  754562MDC_IDC_ENUM_ELECTRODE_NAME_Ring

A ring electrode of the lead.

urn:iso:std:iso:11073:10101  754563MDC_IDC_ENUM_ELECTRODE_NAME_Ring1

The first ring electrode of a multi-electrode lead relative to the distal end of the lead.

urn:iso:std:iso:11073:10101  754564MDC_IDC_ENUM_ELECTRODE_NAME_Ring2

The second ring electrode of a multi-electrode lead relative to the distal end of the lead.

urn:iso:std:iso:11073:10101  754565MDC_IDC_ENUM_ELECTRODE_NAME_Ring3

The third ring electrode of a multi-electrode lead relative to the distal end of the lead.

urn:iso:std:iso:11073:10101  754566MDC_IDC_ENUM_ELECTRODE_NAME_Ring4

The fourth ring electrode of a multi-electrode lead relative to the distal end of the lead.

urn:iso:std:iso:11073:10101  754567MDC_IDC_ENUM_ELECTRODE_NAME_Coil

A coil electrode of the lead.

urn:iso:std:iso:11073:10101  754568MDC_IDC_ENUM_ELECTRODE_NAME_SubQPatch

A subcutaneous patch electrode.

urn:iso:std:iso:11073:10101  754569MDC_IDC_ENUM_ELECTRODE_NAME_Can

The housing electrode of the device.

urn:iso:std:iso:11073:10101  754570MDC_IDC_ENUM_ELECTRODE_NAME_Other1

Other electrode 1.

urn:iso:std:iso:11073:10101  754571MDC_IDC_ENUM_ELECTRODE_NAME_Other2

Other electrode 2.

urn:iso:std:iso:11073:10101  754572MDC_IDC_ENUM_ELECTRODE_NAME_Other3

Other electrode 3.

urn:iso:std:iso:11073:10101  754573MDC_IDC_ENUM_ELECTRODE_NAME_Other4

Other electrode 4.

urn:iso:std:iso:11073:10101  754574MDC_IDC_ENUM_ELECTRODE_NAME_Other5

Other electrode 5.

urn:iso:std:iso:11073:10101  754575MDC_IDC_ENUM_ELECTRODE_NAME_Other6

Other electrode 6.

urn:iso:std:iso:11073:10101  754576MDC_IDC_ENUM_ELECTRODE_NAME_Other7

Other electrode 7.

urn:iso:std:iso:11073:10101  754577MDC_IDC_ENUM_ELECTRODE_NAME_Other8

Other electrode 8.

urn:iso:std:iso:11073:10101  754578MDC_IDC_ENUM_ELECTRODE_NAME_Other9

Other electrode 9.

urn:iso:std:iso:11073:10101  754579MDC_IDC_ENUM_ELECTRODE_NAME_Other10

Other electrode 10.

urn:iso:std:iso:11073:10101  754580MDC_IDC_ENUM_ELECTRODE_NAME_Unknown

An indicator showing that the type is unknown for the electrode.

urn:iso:std:iso:11073:10101  754625MDC_IDC_ENUM_SENSING_ADAPTATION_MODE_AdaptiveSensing

The sensing threshold changes automatically.

urn:iso:std:iso:11073:10101  754626MDC_IDC_ENUM_SENSING_ADAPTATION_MODE_FixedSensing

The sensing threshold is fixed.

urn:iso:std:iso:11073:10101  754689MDC_IDC_ENUM_PACING_CAPTURE_MODE_AdaptiveCapture

The pacing stimulus changes automatically to maintain capture.

urn:iso:std:iso:11073:10101  754690MDC_IDC_ENUM_PACING_CAPTURE_MODE_FixedPacing

The pacing stimulus is fixed.

urn:iso:std:iso:11073:10101  754691MDC_IDC_ENUM_PACING_CAPTURE_MODE_MonitorCapture

The device measures the stimulus threshold for cardiac pacing but does not automatically change the stimulus.

urn:iso:std:iso:11073:10101  754692MDC_IDC_ENUM_PACING_CAPTURE_MODE_Other

A capture mode other than those included in the nomenclature.

urn:iso:std:iso:11073:10101  754753MDC_IDC_ENUM_BRADY_MODE_AAI

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754754MDC_IDC_ENUM_BRADY_MODE_AAIR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754755MDC_IDC_ENUM_BRADY_MODE_AAT

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754756MDC_IDC_ENUM_BRADY_MODE_AATR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754757MDC_IDC_ENUM_BRADY_MODE_AOO

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754758MDC_IDC_ENUM_BRADY_MODE_AOOR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754759MDC_IDC_ENUM_BRADY_MODE_DAD

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754760MDC_IDC_ENUM_BRADY_MODE_DDD

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754761MDC_IDC_ENUM_BRADY_MODE_DDDR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754762MDC_IDC_ENUM_BRADY_MODE_DDI

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754763MDC_IDC_ENUM_BRADY_MODE_DDIR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754764MDC_IDC_ENUM_BRADY_MODE_DOO

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754765MDC_IDC_ENUM_BRADY_MODE_DOOR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754766MDC_IDC_ENUM_BRADY_MODE_DVI

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754767MDC_IDC_ENUM_BRADY_MODE_DVIR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754768MDC_IDC_ENUM_BRADY_MODE_VAT

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754769MDC_IDC_ENUM_BRADY_MODE_VDD

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754770MDC_IDC_ENUM_BRADY_MODE_VDDR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754771MDC_IDC_ENUM_BRADY_MODE_VOO

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754772MDC_IDC_ENUM_BRADY_MODE_VOOR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754773MDC_IDC_ENUM_BRADY_MODE_VVI

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754774MDC_IDC_ENUM_BRADY_MODE_VVIR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754775MDC_IDC_ENUM_BRADY_MODE_VVT

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754776MDC_IDC_ENUM_BRADY_MODE_OOO

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754777MDC_IDC_ENUM_BRADY_MODE_OOOR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754778MDC_IDC_ENUM_BRADY_MODE_VDI

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754779MDC_IDC_ENUM_BRADY_MODE_VDIR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754780MDC_IDC_ENUM_BRADY_MODE_ODO

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754781MDC_IDC_ENUM_BRADY_MODE_VVTR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754782MDC_IDC_ENUM_BRADY_MODE_DDTR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754783MDC_IDC_ENUM_BRADY_MODE_OVO

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754784MDC_IDC_ENUM_BRADY_MODE_DVTR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754785MDC_IDC_ENUM_BRADY_MODE_DDT

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754786MDC_IDC_ENUM_BRADY_MODE_VDTR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754787MDC_IDC_ENUM_BRADY_MODE_VDT

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754788MDC_IDC_ENUM_BRADY_MODE_ADIR

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754789MDC_IDC_ENUM_BRADY_MODE_ADI

The pacing mode per the NBG standard.

urn:iso:std:iso:11073:10101  754790MDC_IDC_ENUM_BRADY_MODE_Unknown

An indicator showing that the brady mode is unknown for the brady device.

urn:iso:std:iso:11073:10101  754817MDC_IDC_ENUM_THERAPY_STATUS_On

An indicator showing that tachy therapies are on.

urn:iso:std:iso:11073:10101  754818MDC_IDC_ENUM_THERAPY_STATUS_Off

An indicator showing that tachy therapies are off.

urn:iso:std:iso:11073:10101  754819MDC_IDC_ENUM_THERAPY_STATUS_Unknown

An indicator showing that the tachy therapy status is unknown for the tachy device.

urn:iso:std:iso:11073:10101  754881MDC_IDC_ENUM_EPISODE_TYPE_Epis_VF

An episode type of ventricular fibrillation.

urn:iso:std:iso:11073:10101  754882MDC_IDC_ENUM_EPISODE_TYPE_Epis_VT

An episode type of ventricular tachycardia.

urn:iso:std:iso:11073:10101  754883MDC_IDC_ENUM_EPISODE_TYPE_Epis_ATAF

An episode type of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  754884MDC_IDC_ENUM_EPISODE_TYPE_Epis_SVT

An episode type of supraventricular tachycardia.

urn:iso:std:iso:11073:10101  754885MDC_IDC_ENUM_EPISODE_TYPE_Epis_Monitor

An episode type that is only being observed.

urn:iso:std:iso:11073:10101  754886MDC_IDC_ENUM_EPISODE_TYPE_Epis_PeriodicEGM

An episode type that is being observed periodically.

urn:iso:std:iso:11073:10101  754887MDC_IDC_ENUM_EPISODE_TYPE_Epis_PatientActivated

An episode type that is triggered by the patient.

urn:iso:std:iso:11073:10101  754888MDC_IDC_ENUM_EPISODE_TYPE_Epis_Other

An episode that is not included in the enumerations.

urn:iso:std:iso:11073:10101  754945MDC_IDC_ENUM_ZONE_TYPE_Zone_VF

An zone type of ventricular fibrillation.

urn:iso:std:iso:11073:10101  754946MDC_IDC_ENUM_ZONE_TYPE_Zone_VT

An zone type of ventricular tachycardia.

urn:iso:std:iso:11073:10101  754947MDC_IDC_ENUM_ZONE_TYPE_Zone_ATAF

An zone type of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  754948MDC_IDC_ENUM_ZONE_TYPE_Zone_Other

Indicates a selection other than any in the list of selections.

urn:iso:std:iso:11073:10101  755009MDC_IDC_ENUM_ZONE_STATUS_Active

An indicator showing that tachyarrhythmia detection and therapy is on for the designated chamber.

urn:iso:std:iso:11073:10101  755010MDC_IDC_ENUM_ZONE_STATUS_Inactive

An Indicator showing that tachyarrhythmia detection and therapy is off for the designated chamber.

urn:iso:std:iso:11073:10101  755011MDC_IDC_ENUM_ZONE_STATUS_Monitor

An indicator showing that tachyarrhythmia detection is on but therapy is off for the designated chamber.

urn:iso:std:iso:11073:10101  755012MDC_IDC_ENUM_ZONE_STATUS_Unknown

An indicator showing that tachyarrhythmia detection an therapy is unknown for the designated chamber.

urn:iso:std:iso:11073:10101  755073MDC_IDC_ENUM_ATP_TYPE_Burst

A tachyarrhythmia therapy that uses pacing stimulus at a fixed pacing rate for a specific number of pulses.

urn:iso:std:iso:11073:10101  755074MDC_IDC_ENUM_ATP_TYPE_Ramp

A tachyarrhythmia therapy that uses pacing stimulus at a pacing rate that increases or decreases.

urn:iso:std:iso:11073:10101  755075MDC_IDC_ENUM_ATP_TYPE_BurstScan

A tachyarrhythmia therapy that uses pacing stimulus at a fixed pacing rate with the time between ATP pulses being reduced with each subsequent burst.

urn:iso:std:iso:11073:10101  755076MDC_IDC_ENUM_ATP_TYPE_RampScan

A tachyarrhythmia therapy that uses pacing stimulus at a pacing rate with the time between ATP pulses being reduced with each subsequent burst.

urn:iso:std:iso:11073:10101  755077MDC_IDC_ENUM_ATP_TYPE_Other

Indicates a selection other than any in the list of selections.

urn:iso:std:iso:11073:10101  755078MDC_IDC_ENUM_ATP_TYPE_Unknown

An indicator showing that ATP type is unknown for the ATP pulses.

urn:iso:std:iso:11073:10101  755137MDC_IDC_ENUM_EPISODE_THERAPY_RESULT_Successful

An indicator that shows the specific therapy was successful in terminating the tachyarrhythmia.

urn:iso:std:iso:11073:10101  755138MDC_IDC_ENUM_EPISODE_THERAPY_RESULT_Unsuccessful

An indicator that shows the specific therapy was not successful in terminating the tachyarrhythmia.

urn:iso:std:iso:11073:10101  755139MDC_IDC_ENUM_EPISODE_THERAPY_RESULT_Unknown

An indicator that shows the results of the specific therapy was unkown.

urn:iso:std:iso:11073:10101  755201MDC_IDC_ENUM_SESS_REPROGRAMMED_YES

An indicator that shows the device was re-programmed during the last session.

urn:iso:std:iso:11073:10101  755202MDC_IDC_ENUM_SESS_REPROGRAMMED_NO

An indicator that shows the device was not re-programmed during the last session.

urn:iso:std:iso:11073:10101  755203MDC_IDC_ENUM_SESS_REPROGRAMMED_Unknown

An indicator that shows that device re-programming is unknown.

urn:iso:std:iso:11073:10101  755265MDC_IDC_ENUM_CRT_PACED_CHAMBERS_RV_Only

An indicator that shows that only the RV chamber is being paced for resynchronization.

urn:iso:std:iso:11073:10101  755266MDC_IDC_ENUM_CRT_PACED_CHAMBERS_LV_Only

An indicator that shows that only the LV chamber is being paced for resynchronization.

urn:iso:std:iso:11073:10101  755267MDC_IDC_ENUM_CRT_PACED_CHAMBERS_BiV

An indicator that shows that both the RV and LV chamber are being paced for resynchronization.

urn:iso:std:iso:11073:10101  755268MDC_IDC_ENUM_CRT_PACED_CHAMBERS_Unknown

An indicator showing that CRT paced chambers are unknown for the CRT device.

urn:iso:std:iso:11073:10101  755329MDC_IDC_ENUM_EPISODE_TYPE_INDUCED_YES

An indicator that shows that the episode was induced.

urn:iso:std:iso:11073:10101  755330MDC_IDC_ENUM_EPISODE_TYPE_INDUCED_NO

An indicator that shows that the episode was not induced.

urn:iso:std:iso:11073:10101  755331MDC_IDC_ENUM_EPISODE_TYPE_INDUCED_Unknown

An indicator showing that whether the episode was induced or not unknown for the recorded episode.

urn:iso:std:iso:11073:10101  753757MDC_IDC_ENUM_MFG_ABT

A manufacturer name.

urn:iso:std:iso:11073:10101  753758MDC_IDC_ENUM_MFG_MPT

A manufacturer name.

urn:iso:std:iso:11073:10101  754118MDC_IDC_ENUM_BATTERY_STATUS_OK

An indicator that the battery is Ok.

urn:iso:std:iso:11073:10101  755393MDC_IDC_ENUM_ADVISORY_STATUS_Advisory

The given device or lead is under an advisory.

urn:iso:std:iso:11073:10101  755394MDC_IDC_ENUM_ADVISORY_STATUS_No_Advisory

The given device or lead is not under an advisory.

urn:iso:std:iso:11073:10101  755395MDC_IDC_ENUM_ADVISORY_STATUS_Unknown

The advisory status information for the given device or lead is unknown.

urn:iso:std:iso:11073:10101  755457MDC_IDC_ENUM_NOTIFICATION_TYPE_Device

Implantable cardiac device hardware or software anomaly is detected or battery is low.

urn:iso:std:iso:11073:10101  755458MDC_IDC_ENUM_NOTIFICATION_TYPE_Device_Settings

Implantable cardiac device settings may need clinician attention.

urn:iso:std:iso:11073:10101  755459MDC_IDC_ENUM_NOTIFICATION_TYPE_Lead

Implantable lead or connection finding

urn:iso:std:iso:11073:10101  755460MDC_IDC_ENUM_NOTIFICATION_TYPE_Short_Atrial_Intervals

Fast atrial rate or premature atrial contraction finding

urn:iso:std:iso:11073:10101  755461MDC_IDC_ENUM_NOTIFICATION_TYPE_Short_Ventricular_Intervals

Fast ventricular rate or premature ventricular contraction finding

urn:iso:std:iso:11073:10101  755462MDC_IDC_ENUM_NOTIFICATION_TYPE_Bradyarrhythmia

Slow rate, asystole, or rate drop finding

urn:iso:std:iso:11073:10101  755463MDC_IDC_ENUM_NOTIFICATION_TYPE_Heart_Failure

Heart Failure related finding (related to heart failure sensors)

urn:iso:std:iso:11073:10101  755464MDC_IDC_ENUM_NOTIFICATION_TYPE_Shock_Therapy_Delivered

Shock therapy has been delivered

urn:iso:std:iso:11073:10101  755465MDC_IDC_ENUM_NOTIFICATION_TYPE_ATP_Therapy_Delivered

ATP therapy has been delivered

urn:iso:std:iso:11073:10101  755466MDC_IDC_ENUM_NOTIFICATION_TYPE_Pacing_Therapy

Bradycardia or Cardiac Resynchronization (CRT) pacing therapy finding

urn:iso:std:iso:11073:10101  755467MDC_IDC_ENUM_NOTIFICATION_TYPE_Other_Clinical

A non-classified clinical finding

urn:iso:std:iso:11073:10101  755468MDC_IDC_ENUM_NOTIFICATION_TYPE_Follow_up

A follow-up has occurred. This notification typically includes scheduled follow-ups. This is to be used when there is an active notification, not to duplicate the information in session type.

urn:iso:std:iso:11073:10101  755469MDC_IDC_ENUM_NOTIFICATION_TYPE_Patient_Request

Notification of a patient triggered message or recording (e.g., due to symptoms). This shall NOT be used to indicate a routine transmission that was initiated by the patient.

urn:iso:std:iso:11073:10101  755470MDC_IDC_ENUM_NOTIFICATION_TYPE_Connectivity_Administrative

A condition related to remote monitoring occurred that indicates patient remote monitoring is not operating properly or other administrative reasons.

urn:iso:std:iso:11073:10101  755521MDC_IDC_ENUM_NOTIFICATION_PRIORITY_High

An indicator showing that the notification has a high priority.

urn:iso:std:iso:11073:10101  755522MDC_IDC_ENUM_NOTIFICATION_PRIORITY_Medium

An indicator showing that the notification has a medium priority.

urn:iso:std:iso:11073:10101  755523MDC_IDC_ENUM_NOTIFICATION_PRIORITY_Low

An indicator showing that the notification has a low priority.

urn:iso:std:iso:11073:10101  755524MDC_IDC_ENUM_NOTIFICATION_PRIORITY_Informative

An indicator showing that the notification is informative and is not a priority.

urn:iso:std:iso:11073:10101  755525MDC_IDC_ENUM_NOTIFICATION_PRIORITY_Not_Indicated

The notification priority is not indicated.

urn:iso:std:iso:11073:10101  755585MDC_IDC_ENUM_BLANKING_REFRACTORY_ADAPTATION_MODE_Adaptive

An indicator showing that the corresponding interval is adapting

urn:iso:std:iso:11073:10101  755586MDC_IDC_ENUM_BLANKING_REFRACTORY_ADAPTATION_MODE_Fixed

An indicator showing that the corresponding interval is fixed

urn:iso:std:iso:11073:10101  755587MDC_IDC_ENUM_BLANKING_REFRACTORY_ADAPTATION_MODE_Unknown

An indicator showing that the according interval adaptation is unknown

urn:iso:std:iso:11073:10101  755649MDC_IDC_ENUM_RV_PACE_AVOIDANCE_STATUS_On

An indicator showing that an RV pace avoidance feature or features are turned on

urn:iso:std:iso:11073:10101  755650MDC_IDC_ENUM_RV_PACE_AVOIDANCE_STATUS_Off

An indicator showing that an RV pace avoidance feature or features are turned off

urn:iso:std:iso:11073:10101  755651MDC_IDC_ENUM_RV_PACE_AVOIDANCE_STATUS_Not_Available

An indicator showing that an RV pace avoidance feature is not available for this device

urn:iso:std:iso:11073:10101  755713MDC_IDC_ENUM_CRT_MULTISITE_PACING_STATUS_On

An indicator showing that multisite pacing is turned on

urn:iso:std:iso:11073:10101  755714MDC_IDC_ENUM_CRT_MULTISITE_PACING_STATUS_Off

An indicator showing that multisite pacing is turned off

urn:iso:std:iso:11073:10101  755715MDC_IDC_ENUM_CRT_MULTISITE_PACING_STATUS_Auto

An indicator showing that multisite pacing is set to automatic

urn:iso:std:iso:11073:10101  755716MDC_IDC_ENUM_CRT_MULTISITE_PACING_STATUS_Auto_On

An indicator showing that multisite pacing is set to automatic and is currently on

urn:iso:std:iso:11073:10101  755717MDC_IDC_ENUM_CRT_MULTISITE_PACING_STATUS_Auto_Off

An indicator showing that multisite pacing is set to automatic but is currently off

urn:iso:std:iso:11073:10101  755777MDC_IDC_ENUM_BRADY_AF_SUPPRESSION_STATUS_On

An indicator showing that an AF suppression algorithm is on

urn:iso:std:iso:11073:10101  755778MDC_IDC_ENUM_BRADY_AF_SUPPRESSION_STATUS_Off

An indicator showing that an AF suppression algorithm is off

urn:iso:std:iso:11073:10101  755779MDC_IDC_ENUM_BRADY_AF_SUPPRESSION_STATUS_Not_Available

An indicator showing that an AF suppression algorithm is not available

urn:iso:std:iso:11073:10101  755841MDC_IDC_ENUM_EPISODE_IN_PROGRESS_STATUS_Yes

An indicator that shows that the episode is in progress.

urn:iso:std:iso:11073:10101  755842MDC_IDC_ENUM_EPISODE_IN_PROGRESS_STATUS_No

An indicator that shows that the episode is not in progress.

urn:iso:std:iso:11073:10101  755843MDC_IDC_ENUM_EPISODE_IN_PROGRESS_STATUS_Unknown

An indicator showing that it is unknown if the episode is in progress.

urn:iso:std:iso:11073:10101  770049MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_VF

An episode of ventricular fibrillation (BIOTRONIK).

urn:iso:std:iso:11073:10101  770050MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_VT

An episode of ventricular tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770051MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_VT1

An episode VT1 of ventricular tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770052MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_VT2

An episode VT2 of ventricular tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770053MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_NSVT

An episode of a non-sustained ventricular tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770054MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_SVT

An episode of supraventricular tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770055MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_ATAF

An episode of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770056MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_AFlut

An episode of atrial flutter (BIOTRONIK).

urn:iso:std:iso:11073:10101  770057MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_AFib

An episode of atrial fibrillation (BIOTRONIK).

urn:iso:std:iso:11073:10101  770058MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_AT

An episode of atrial tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770059MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_ModeSw

An episode of mode switching (BIOTRONIK).

urn:iso:std:iso:11073:10101  770060MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_AMon

An atrial monitoring episode (BIOTRONIK).

urn:iso:std:iso:11073:10101  770061MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_VMon

A ventricular monitoring episode (BIOTRONIK).

urn:iso:std:iso:11073:10101  770062MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_HVR

An episode of high ventricular rate (BIOTRONIK).

urn:iso:std:iso:11073:10101  770063MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_HAR

An episode of high atrial rate (BIOTRONIK).

urn:iso:std:iso:11073:10101  770064MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_HR

An episode of high rate (BIOTRONIK).

urn:iso:std:iso:11073:10101  770065MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_PMT

An episode of pacemaker mediated tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770066MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_PIEGM

A periodic IEGM (BIOTRONIK).

urn:iso:std:iso:11073:10101  770067MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_PAT

A patient triggered IEGM (BIOTRONIK).

urn:iso:std:iso:11073:10101  770068MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_BRADY

A bradycardia episode (BIOTRONIK).

urn:iso:std:iso:11073:10101  770069MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_ASYST

An episode triggered by an asystole (BIOTRONIK).

urn:iso:std:iso:11073:10101  770070MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_LEAD

An episode triggered by a lead issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770071MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_RateDrop

An episode triggered by a rate drop (BIOTRONIK).

urn:iso:std:iso:11073:10101  770072MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_RA_Lead

A recording related to an RA lead issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770073MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_RV_Lead

A recording related to an RV lead issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770074MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_LV_Lead

A recording related to an LV lead issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770075MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_Shock_Lead

A recording related to a Shock lead issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770076MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_RVp_Start

A recording related to the start of RV pacing (BIOTRONIK).

urn:iso:std:iso:11073:10101  770077MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_CRT_End

A recording related to the end of CRT pacing (BIOTRONIK).

urn:iso:std:iso:11073:10101  770078MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_MRI

A recording related to magnetic resonance imaging (BIOTRONIK).

urn:iso:std:iso:11073:10101  770079MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_TECH

A recording related to a technical device issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770080MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_OHVR

A recording related to an ongoing high ventricular rate (BIOTRONIK).

urn:iso:std:iso:11073:10101  770081MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_NST_Slow

An episode of a non-sustained slow tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770082MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_NST_Fast

An episode of a non-sustained fast tachycardia (BIOTRONIK).

urn:iso:std:iso:11073:10101  770083MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BIO-Epis_LV2_Lead

A recording related to an LV2 lead issue (BIOTRONIK).

urn:iso:std:iso:11073:10101  770113MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_VF

The ventricular fibrillation zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770114MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_VT

The ventricular tachycardia zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770115MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_VT1

The ventricular tachycardia zone 1 (BIOTRONIK).

urn:iso:std:iso:11073:10101  770116MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_VT2

The ventricular tachycardia zone 2 (BIOTRONIK).

urn:iso:std:iso:11073:10101  770117MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_SVT

The supraventricular tachycardia zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770118MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_ATAF

The atrial tachycardia / atrial fibrillation zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770119MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_AFlut

The atrial flutter zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770120MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_AFib

The atrial fibrillation zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770121MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_AT

The atrial tachycardia zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770122MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_ModeSw

The mode switching zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770123MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_AMon

The atrial monitoring zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770124MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_VMon

The ventricular monitoring zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770125MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_HVR

The high ventricular rate zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770126MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_HAR

The high atrial rate zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770127MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_HR

The high rate zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770128MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_BRADY

The bradycardia zone (BIOTRONIK).

urn:iso:std:iso:11073:10101  770129MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_ASYST

The settings for an asystole detection (BIOTRONIK)

urn:iso:std:iso:11073:10101  770130MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BIO-Zone_RateDrop

The settings for a rate drop detection (BIOTRONIK).

urn:iso:std:iso:11073:10101  771073MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_VF

A Boston Scientific episode subclassification of ventricular fibrillation.

urn:iso:std:iso:11073:10101  771074MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_VT

A Boston Scientific episode subclassification of ventricular tachycardia.

urn:iso:std:iso:11073:10101  771075MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_VT-1

A Boston Scientific episode subclassification of fast ventricular tachycardia.

urn:iso:std:iso:11073:10101  771076MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SVT

A Boston Scientific episode subclassification of supraventricular tachycardia.

urn:iso:std:iso:11073:10101  771077MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_NSVT

A Boston Scientific episode subclassification of nonsustained ventricular tachycardia.

urn:iso:std:iso:11073:10101  771078MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ATR

A Boston Scientific episode subclassification of atrial tachycardia response.

urn:iso:std:iso:11073:10101  771079MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_PMT

A Boston Scientific episode subclassification of pacemaker mediated tachycardia.

urn:iso:std:iso:11073:10101  771080MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_PTM

A Boston Scientific episode subclassification of patient triggered monitor.

urn:iso:std:iso:11073:10101  771081MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_Afib

A Boston Scientific episode subclassification of atrial fibrillation.

urn:iso:std:iso:11073:10101  771082MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_AF

A Boston Scientific episode subclassification of atrial fibrillation.

urn:iso:std:iso:11073:10101  771083MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_AT

A Boston Scientific episode subclassification of atrial tachycardia.

urn:iso:std:iso:11073:10101  771084MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_RMS

A Boston Scientific episode subclassification of reverse mode switch episode. This episode type includes RMS and RYTHMIQ episodes.

urn:iso:std:iso:11073:10101  771085MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_APMRT

A Boston Scientific episode subclassification of presenting EGM/S-ECG.

urn:iso:std:iso:11073:10101  771086MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_Tachy

A Boston Scientific episode sub-classification of tachycardia. This episode type can be generated by Brady SSI devices.

urn:iso:std:iso:11073:10101  771087MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SBR

A Boston Scientific episode sub-classification of sudden brady response.

urn:iso:std:iso:11073:10101  771088MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_CmdV

A Boston Scientific episode sub-classification of commanded shock episode.

urn:iso:std:iso:11073:10101  771089MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_RVAutoThresh

A Boston Scientific episode sub-classification of RV Autothreshold.

urn:iso:std:iso:11073:10101  771090MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_RAAutoThresh

A Boston Scientific episode sub-classification of RA Autothreshold.

urn:iso:std:iso:11073:10101  771091MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_LVAutoThresh

A Boston Scientific episode sub-classification of LV Autothreshold.

urn:iso:std:iso:11073:10101  771092MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_MRI

A Boston Scientific episode sub-classification of MRI.

urn:iso:std:iso:11073:10101  771093MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SICD_Treated

A Boston Scientific episode sub-classification of Treated. This episode type can be generated by S-ICD devices.

urn:iso:std:iso:11073:10101  771094MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SICD_Untreated

A Boston Scientific episode sub-classification of Untreated. This episode type can be generated by S-ICD devices.

urn:iso:std:iso:11073:10101  771095MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SICD_AF

A Boston Scientific episode sub-classification of AF. This episode type can be generated by S-ICD devices.

urn:iso:std:iso:11073:10101  771096MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Brady

A Boston Scientific episode sub-classification of Brady. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771097MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Pause

A Boston Scientific episode sub-classification of Pause. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771098MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_AF

A Boston Scientific episode sub-classification of AF. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771099MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_AT

A Boston Scientific episode sub-classification of AT. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771100MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Tachy

A Boston Scientific episode sub-classification of Tachy. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771101MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_TachyVT

A Boston Scientific episode sub-classification of Tachy categorized as VT. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771102MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_TachySVT

A Boston Scientific episode sub-classification of Tachy categorized as SVT. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771103MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_TachytoVF

A Boston Scientific episode sub-classification of Tachy where the tachyarrhythmia accelerated to the VF zone. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771104MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_TachyVTtoVF

A Boston Scientific episode sub-classification of Tachy where the tachyarrhythmia accelerated from VT to VF. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771105MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_TachySVTtoVF

A Boston Scientific episode sub-classification of Tachy where the tachyarrhythmia accelerated from SVT to VF. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771106MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_TachyVF

A Boston Scientific episode sub-classification of Tachy categorized as VF. This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771107MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Symptom

A Boston Scientific episode sub-classification of Symptom where the patient indicated symptom(s). This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771108MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Brady_Symptom

A Boston Scientific episode sub-classification of Brady with Symptom where the device detected a Brady event and the patient indicated symptom(s). This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771109MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Pause_Symptom

A Boston Scientific episode sub-classification of Pause with Symptom where the device detected a Pause event and the patient indicated symptom(s). This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771110MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_AF_Symptom

A Boston Scientific episode sub-classification of AF with Symptom where the device detected an AF event and the patient indicated symptom(s). This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771111MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_AT_Symptom

A Boston Scientific episode sub-classification of AT with Symptom where the device detected an AT event and the patient indicated symptom(s). This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771112MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_ICM_Tachy_Symptom

A Boston Scientific episode sub-classification of Tachy with Symptom where the device detected a Tachy event and the patient indicated symptom(s). This episode type can be generated by ICM devices.

urn:iso:std:iso:11073:10101  771113MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_NoThpyEpsd

A Boston Scientific episode sub-classification of No Therapy Programmed. Either no therapy was programmed in the Tachy zone in which the episode was detected, Tachy mode was monitor only, or a magnet was applied when the episode occurred.

urn:iso:std:iso:11073:10101  771114MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_Other_Untreated

A Boston Scientific episode sub-classification of Other Untreated, where duration was met but the device algorithms indicated not to treat or therapy was manually diverted.

urn:iso:std:iso:11073:10101  771115MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SAM

A Boston Scientific episode sub-classification of Signal Artifact Monitor (SAM).

urn:iso:std:iso:11073:10101  771116MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_VT_VGrtrA

A Boston Scientific episode sub-classification of ventricular tachycardia where the ventricular rate was > the atrial rate. This episode type can be generated by Brady and CRT-P devices.

urn:iso:std:iso:11073:10101  771117MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SVT_NotVGrtrA

A Boston Scientific episode sub-classification of supraventricular tachycardia where the ventricular rate was <= the atrial rate. This episode type can be generated by Brady and CRT-P devices.

urn:iso:std:iso:11073:10101  771118MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_SMART_Pass

A Boston Scientific episode sub-classification of SMART Pass.

urn:iso:std:iso:11073:10101  771119MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_NonSust

A Boston Scientific episode sub-classification of nonsustained tachycardia.

urn:iso:std:iso:11073:10101  771120MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_BSX-Epis_NonSustV

A Boston Scientific episode sub-classification of nonsustained V tachycardia.

urn:iso:std:iso:11073:10101  771137MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_VT

A Boston Scientific zone subclassification of ventricular tachycardia.

urn:iso:std:iso:11073:10101  771138MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_VT-1

A Boston Scientific zone subclassification of fast ventricular tachycardia.

urn:iso:std:iso:11073:10101  771139MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_VF

A Boston Scientific zone subclassification of fast ventricular fibrillation.

urn:iso:std:iso:11073:10101  771140MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_SVT

A Boston Scientific zone subclassification of supraventricular tachycardia.

urn:iso:std:iso:11073:10101  771141MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_Afib

A Boston Scientific zone subclassification of atrial fibrillation.

urn:iso:std:iso:11073:10101  771142MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_AF

A Boston Scientific zone subclassification of atrial fibrillation.

urn:iso:std:iso:11073:10101  771143MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_AT

A Boston Scientific zone subclassification of atrial tachycardia.

urn:iso:std:iso:11073:10101  771144MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_Shock_Zone

A Boston Scientific zone sub-classification of shock zone. This zone is used in S-ICD devices.

urn:iso:std:iso:11073:10101  771145MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_Cond_Shock_Zone

A Boston Scientific zone sub-classification of conditional shock zone. This zone is used in S-ICD devices.

urn:iso:std:iso:11073:10101  771146MDC_IDC_ENUM_ZONE_VENDOR_TYPE_BSX-Zone_Tachy

A Boston Scientific zone sub-classification of tachy. This zone is used in devices that do not provide shock therapy (e.g., pacemaker) that can identify tachyarrhythmias.

urn:iso:std:iso:11073:10101  772097MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_VF

A Medtronic episode subclassification of ventricular fibrillation.

urn:iso:std:iso:11073:10101  772098MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_VT

A Medtronic episode subclassification of ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  772099MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Fast_VT

A Medtronic episode subclassification of fast ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  772100MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_AT_AF

A Medtronic episode subclassification of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  772101MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Fast_AT_AF

A Medtronic episode subclassification of fast atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  772102MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_SVT

A Medtronic episode subclassification of supraventricular tachycardia.

urn:iso:std:iso:11073:10101  772103MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_NS_VT

A Medtronic episode subclassification of non-sustained ventricular tachycardia.

urn:iso:std:iso:11073:10101  772104MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Periodic_EGM

A Medtronic episode subclassification of periodic EGM recording.

urn:iso:std:iso:11073:10101  772105MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Rate_Drop

A Medtronic episode subclassification of sudden drop in heart rate.

urn:iso:std:iso:11073:10101  772106MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_V_Sensing

A Medtronic episode subclassification of ventricular sensing resulting in inhibition of ventricular pacing therapy.

urn:iso:std:iso:11073:10101  772107MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_HR

A Medtronic episode subclassification of high heart rate without designation of being atrial or ventricular.

urn:iso:std:iso:11073:10101  772108MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_VHR

A Medtronic episode subclassification of high ventricular rate.

urn:iso:std:iso:11073:10101  772109MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_AHR

A Medtronic episode subclassification of high atrial rate.

urn:iso:std:iso:11073:10101  772110MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_VHR_NS

A Medtronic episode sub-classification of non sustained fast ventricular heart rate.

urn:iso:std:iso:11073:10101  772111MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_VT_Mon

A Medtronic episode sub-classification of monitored ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  772112MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_V_Oversensing_Twave

A Medtronic episode sub-classification of ventricular oversensing of T-waves.

urn:iso:std:iso:11073:10101  772113MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_V_Oversensing_Noise

A Medtronic episode sub-classification of ventricular sensing of lead noise.

urn:iso:std:iso:11073:10101  772114MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Mon_AT_AF

A Medtronic episode sub-classification of monitored atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  772115MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Patient_Activated

A Medtronic episode sub-classification of an episode associated with a patient initiated activation.

urn:iso:std:iso:11073:10101  772116MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Non_Effective_CRT

A Medtronic episode sub-classification of Cardiac Resynchronization Therapy that was non effective.

urn:iso:std:iso:11073:10101  772117MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Brady

A Medtronic episode sub-classification of bradycardia.

urn:iso:std:iso:11073:10101  772118MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Asystole

A Medtronic episode sub-classification of asystole or pause.

urn:iso:std:iso:11073:10101  772119MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_MDT-Epis_Mode_Switch

A Medtronic episode sub-classification of mode switch.

urn:iso:std:iso:11073:10101  772161MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_VF

A Medtronic zone subclassification of ventricular fibrillation.

urn:iso:std:iso:11073:10101  772162MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_VT

A Medtronic zone subclassification of ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  772163MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_FastVT

A Medtronic zone subclassification of fast ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  772164MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_FastATAF

A Medtronic zone subclassification of fast atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  772165MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_MonVT

A Medtronic zone subclassification of ventricular tachycardia that is only being monitored with no therapy being delivered.

urn:iso:std:iso:11073:10101  772166MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_MonATAF

A Medtronic zone subclassification of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia, which is being monitored with no therapy being delivered.

urn:iso:std:iso:11073:10101  772167MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_HR

A Medtronic zone subclassification of high heart rate without designation of being atrial or ventricular.

urn:iso:std:iso:11073:10101  772168MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_VHR

A Medtronic zone subclassification of high ventricular rate.

urn:iso:std:iso:11073:10101  772169MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_AHR

A Medtronic zone subclassification of high atrial rate.

urn:iso:std:iso:11073:10101  772170MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_ATAF

A Medtronic zone sub-classification of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  772171MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_Brady

A Medtronic zone sub-classification of a slow rate.

urn:iso:std:iso:11073:10101  772172MDC_IDC_ENUM_ZONE_VENDOR_TYPE_MDT-Zone_Pause

A Medtronic zone sub-classification of a pause or asystole.

urn:iso:std:iso:11073:10101  773121MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VF

A St. Jude Medical episode subclassification of ventricular fibrillation.

urn:iso:std:iso:11073:10101  773122MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT

A St. Jude Medical episode subclassification of ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  773123MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_SVT

A St. Jude Medical episode subclassification of supraventricular tachycardia.

urn:iso:std:iso:11073:10101  773124MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT1

A St. Jude Medical episode subclassification of the slowest tachycardia.

urn:iso:std:iso:11073:10101  773125MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT2

A St. Jude Medical episode subclassification of the faster tachycardia.

urn:iso:std:iso:11073:10101  773126MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_AT_AF

A St. Jude Medical episode subclassification of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  773127MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_AMS

A St. Jude Medical episode subclassification of Auto Mode Switch.

urn:iso:std:iso:11073:10101  773128MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_NoiseReversion

A St. Jude Medical episode subclassification of Noise Revision.

urn:iso:std:iso:11073:10101  773129MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_PMTTermination

A St. Jude Medical episode subclassification of Pacemaker Mediated Tachycardia Termination.

urn:iso:std:iso:11073:10101  773130MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_MagnetResp.

A St. Jude Medical episode subclassification of Magnet Response.

urn:iso:std:iso:11073:10101  773131MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_EmergencyShock

A St. Jude Medical episode subclassification of Emergency Shock.

urn:iso:std:iso:11073:10101  773132MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_MorphTemplate

A St. Jude Medical episode subclassification of Morphology Template update.

urn:iso:std:iso:11073:10101  773133MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_ReturnToSinus

A St. Jude Medical episode subclassification of Return to Sinus condition.

urn:iso:std:iso:11073:10101  773134MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_HighVRate

A St. Jude Medical episode subclassification of High Ventricular Rate.

urn:iso:std:iso:11073:10101  773135MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_HighARate

A St. Jude Medical episode subclassification of High Atrial Rate.

urn:iso:std:iso:11073:10101  773136MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_AMSEntry

A St. Jude Medical episode subclassification of Entry into Auto-Mode Switch.

urn:iso:std:iso:11073:10101  773137MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_AMSExit

A St. Jude Medical episode subclassification of Exit from Auto-Mode Switch.

urn:iso:std:iso:11073:10101  773138MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_AdvHysteresis

A St. Jude Medical episode subclassification of Morphology Template update.

urn:iso:std:iso:11073:10101  773139MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_ConsecutivePVCs

A St. Jude Medical episode subclassification of Consecutive Premature Ventricular Contractions.

urn:iso:std:iso:11073:10101  773140MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_LossOfCapture

A St. Jude Medical episode subclassification of Loss of Capture.

urn:iso:std:iso:11073:10101  773141MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_CannotDetermineSummary

A St. Jude-Medical episode subclassification with no episode summary.

urn:iso:std:iso:11073:10101  773142MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VTTimeout

A St. Jude-Medical episode subclassification with ventricular tachycardia timeout.

urn:iso:std:iso:11073:10101  773143MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_SVT_VTTimeout

A St. Jude-Medical episode subclassification with either supraventricular tachycardia or ventricular tachycardia timeout.

urn:iso:std:iso:11073:10101  773144MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_SVTTimeout

A St. Jude-Medical episode subclassification of induced episode for device-based testing.

urn:iso:std:iso:11073:10101  773145MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_DBT

A St. Jude Medical episode subclassification of DBT.

urn:iso:std:iso:11073:10101  773146MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_Non-sustained

A St. Jude Medical episode subclassification of nonsustained VT.

urn:iso:std:iso:11073:10101  773147MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VF_RVLeadNoise

A St. Jude Medical episode subclassification of Lead Noise seen as VF.

urn:iso:std:iso:11073:10101  773148MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT_RVLeadNoise

A St. Jude Medical episode subclassification of Lead Noise seen as VT.

urn:iso:std:iso:11073:10101  773149MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT1_RVLeadNoise

A St. Jude Medical episode subclassification of Lead Noise seen as VT1.

urn:iso:std:iso:11073:10101  773150MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT2_RVLeadNoise

A St. Jude Medical episode subclassification of Lead Noise seen as VT2.

urn:iso:std:iso:11073:10101  773151MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VF_SecureSenseTimeout

A St. Jude Medical episode subclassification of Secure Sense seen as VF.

urn:iso:std:iso:11073:10101  773152MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT_SecureSenseTimeout

A St. Jude Medical episode subclassification of Secure Sense seen as VT.

urn:iso:std:iso:11073:10101  773153MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT1_SecureSenseTimeout

A St. Jude Medical episode subclassification of Secure Sense seen as VT1.

urn:iso:std:iso:11073:10101  773154MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT2_SecureSenseTimeout

A St. Jude Medical episode subclassification of Secure Sense seen as VT2.

urn:iso:std:iso:11073:10101  773155MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_SVT_RVLeadNoise

A St. Jude Medical episode subclassification of Lead Noise seen as SVT.

urn:iso:std:iso:11073:10101  773156MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_SVTTimeout_RVLeadNoise

A St. Jude Medical episode subclassification of Lead Noise seen as SVT timeout.

urn:iso:std:iso:11073:10101  773157MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_Non-sustained_RVLeadNoise

A St. Jude Medical episode subclassification of lead noise seen as nonsustained VT.

urn:iso:std:iso:11073:10101  773158MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_RVLeadNoise

A St. Jude Medical episode subclassification of RV Lead Noise.

urn:iso:std:iso:11073:10101  773159MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_SecureSenseTimeout

A St. Jude Medical episode subclassification of secure sense timeout.

urn:iso:std:iso:11073:10101  773160MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VF_VFTherapyAssurance

A St. Jude Medical episode sub-clasification of VF, VF Therapy Assurance

urn:iso:std:iso:11073:10101  773161MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT_VFTherapyAssurance

A St. Jude Medical episode sub-clasification of VT, VF Therapy Assurance

urn:iso:std:iso:11073:10101  773162MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT1_VFTherapyAssurance

A St. Jude Medical episode sub-clasification of VT-1, VF Therapy Assurance

urn:iso:std:iso:11073:10101  773163MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_VT2_VFTherapyAssurance

A St. Jude Medical episode sub-clasification of VT-2, VF Therapy Assurance

urn:iso:std:iso:11073:10101  773164MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_PAC_ResponseTimeout

A St. Jude Medical episode sub-clasification of PAC Response Timeout

urn:iso:std:iso:11073:10101  773165MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_Potential_Ventricular_Epiosde

A St. Jude Medical episode sub-clasification of Potential Ventricular Episode

urn:iso:std:iso:11073:10101  773166MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_EndofEpisode

A St. Jude Medical episode sub-clasification of End of Episode

urn:iso:std:iso:11073:10101  773167MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_STJ-Epis_Non-sustained_RV_Oversensing

A St. Jude Medical episode sub-classification of Non-sustained RV Oversensing

urn:iso:std:iso:11073:10101  773185MDC_IDC_ENUM_ZONE_VENDOR_TYPE_STJ-Zone_VF

A St. Jude Medical zone subclassification of ventricular fibrillation.

urn:iso:std:iso:11073:10101  773186MDC_IDC_ENUM_ZONE_VENDOR_TYPE_STJ-Zone_VT

A St. Jude Medical zone subclassification of ventricular tachyarrhythmia.

urn:iso:std:iso:11073:10101  773187MDC_IDC_ENUM_ZONE_VENDOR_TYPE_STJ-Zone_SVT

A St. Jude Medical zone subclassification of supraventricular tachycardia.

urn:iso:std:iso:11073:10101  773188MDC_IDC_ENUM_ZONE_VENDOR_TYPE_STJ-Zone_VT1

A St. Jude Medical zone subclassification of the slowest tachycardia.

urn:iso:std:iso:11073:10101  773189MDC_IDC_ENUM_ZONE_VENDOR_TYPE_STJ-Zone_VT2

A St. Jude Medical zone subclassification of the faster tachycardia.

urn:iso:std:iso:11073:10101  773190MDC_IDC_ENUM_ZONE_VENDOR_TYPE_STJ-Zone_AT_AF

A St. Jude Medical zone subclassification of atrial tachyarrhythmia without being specific about it being fibrillation, flutter, or tachycardia.

urn:iso:std:iso:11073:10101  774145MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_VF

Episode of ventricular fibrillation (Sorin).

urn:iso:std:iso:11073:10101  774146MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_FastVT

Episode of fast ventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774147MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_VT

Episode of ventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774148MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_SlowVT

Episode of slow ventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774149MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_SVT

Episode of supraventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774150MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_SVTVT

Episode of treated supraventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774151MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_SVTST

Episode of nontreated supraventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774152MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_ModeSwitch

Episode of mode switching (Sorin).

urn:iso:std:iso:11073:10101  774153MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_NST

Episode of a non-sustained ventricular tachycardia (Sorin).

urn:iso:std:iso:11073:10101  774154MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_ABurst

Episode of an atrial burst (Sorin).

urn:iso:std:iso:11073:10101  774155MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_VBurst

Episode of a ventricular burst (Sorin).

urn:iso:std:iso:11073:10101  774156MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_AVBI

Episode of atrio-ventricular block I in SafeR mode (Sorin).

urn:iso:std:iso:11073:10101  774157MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_AVBII

Episode of atrio-ventricular block II in SafeR mode (Sorin).

urn:iso:std:iso:11073:10101  774158MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_AVBIII

Episode of atrio-ventricular block III in SafeR mode (Sorin).

urn:iso:std:iso:11073:10101  774159MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_Pause

Episode of pause in SafeR mode (Sorin).

urn:iso:std:iso:11073:10101  774160MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_Security

Episode of AVB in security windows in SafeR mode (Sorin).

urn:iso:std:iso:11073:10101  774161MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_PMT

Episode of PMT detection (Sorin).

urn:iso:std:iso:11073:10101  774162MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_Impedance

Episode of impedance variation between two impedance tests (Sorin).

urn:iso:std:iso:11073:10101  774163MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_VCapture

Episode of threshold variation between two automatic threshold tests (Sorin).

urn:iso:std:iso:11073:10101  774164MDC_IDC_ENUM_EPISODE_VENDOR_TYPE_SOR-Epis_FU

Episode during of follow-up (Sorin).

urn:iso:std:iso:11073:10101  774209MDC_IDC_ENUM_ZONE_VENDOR_TYPE_SOR-Zone_VF

The ventricular fibrillation zone (Sorin).

urn:iso:std:iso:11073:10101  774210MDC_IDC_ENUM_ZONE_VENDOR_TYPE_SOR-Zone_FastVT

The fast ventricular tachycardia zone (Sorin).

urn:iso:std:iso:11073:10101  774211MDC_IDC_ENUM_ZONE_VENDOR_TYPE_SOR-Zone_VT

The ventricular tachycardia zone (Sorin).

urn:iso:std:iso:11073:10101  774212MDC_IDC_ENUM_ZONE_VENDOR_TYPE_SOR-Zone_SlowVT

The slow ventricular tachycardia zone (Sorin).

urn:iso:std:iso:11073:10101  720905MDC_IDC_DEV_ADVISORY_INFO_STATUS

This is an indication of the availability or status of advisory information of the cardiac device.

urn:iso:std:iso:11073:10101  720906MDC_IDC_DEV_ADVISORY_INFO

Advisory information summary text for the given device type or serial number.

urn:iso:std:iso:11073:10101  720907MDC_IDC_DEV_ADVISORY_INFO_URL

URL to advisory information for the given device type or serial number.

urn:iso:std:iso:11073:10101  720908MDC_IDC_DEV_UNIQUE_ID

A unique identifier for the device (e.g., UDI) that is unique throughout the world and is from an accredited issuing agency.

urn:iso:std:iso:11073:10101  720909MDC_IDC_DEV_UNIQUE_ID_ISSUER

The accredited issuing agency for the device unique ID.

urn:iso:std:iso:11073:10101  720972MDC_IDC_LEAD_ADVISORY_INFO_STATUS

This is an indication of the availability or status of advisory information of the lead.

urn:iso:std:iso:11073:10101  720973MDC_IDC_LEAD_ADVISORY_INFO

Advisory information summary text for the given lead type or serial number.

urn:iso:std:iso:11073:10101  720974MDC_IDC_LEAD_ADVISORY_INFO_URL

URL to advisory information for the given lead type or serial number.

urn:iso:std:iso:11073:10101  720975MDC_IDC_LEAD_UNIQUE_ID

A unique identifier for the lead (e.g., UDI) that is unique throughout the world and is from an accredited issuing agency.

urn:iso:std:iso:11073:10101  720976MDC_IDC_LEAD_UNIQUE_ID_ISSUER

The accredited issuing agency for the lead unique ID.

urn:iso:std:iso:11073:10101  721601MDC_IDC_MSMT_BATTERY_REMAINING_LONGEVITY_TIMEFRAME

The end of the time period for which the estimated battery remaining longevity is calculated.

urn:iso:std:iso:11073:10101  721602MDC_IDC_MSMT_BATTERY_REMAINING_PERCENTAGE_TIMEFRAME

The end of the time period for which the estimated battery remaining percentage is calculated.

urn:iso:std:iso:11073:10101  721603MDC_IDC_MSMT_BATTERY_RRT_REACHED_DTM

The date and time when the implanted device reached RRT.

urn:iso:std:iso:11073:10101  729409MDC_IDC_SET_CRT_MULTISITE_PACING_STATUS

The status of a multisite pacing feature.

urn:iso:std:iso:11073:10101  729410MDC_IDC_SET_CRT_MULTISITE_PACING_LVLV_DELAY

The interval from the first paced ventricular event to a second paced ventricular event. The interval can be zero or greater.

urn:iso:std:iso:11073:10101  731457MDC_IDC_SET_BRADY_AF_SUPPRESSION_ALGORITHM_STATUS

The status of the AF Suppression algorithm(s).

urn:iso:std:iso:11073:10101  731458MDC_IDC_SET_BRADY_AF_SUPPRESSION_ALGORITHM_NAME

The manufacturer name for the AF suppression algorithm(s).

AF suppression algorithms are pacing algorithms that are intended to prevent the onset of atrial tachyarrhythmias.

AF suppression does not include:

  • Ventricular rate control algorithms
  • Anti-tachy pacing therapy that is intended to terminate an atrial arrhythmia
urn:iso:std:iso:11073:10101  731459MDC_IDC_SET_BRADY_RV_PACE_AVOIDANCE_STATUS

The status of the RV pace avoidance algorithm.

urn:iso:std:iso:11073:10101  731460MDC_IDC_SET_BRADY_RV_PACE_AVOIDANCE

The manufacturer's name of the algorithm(s) intended to reduce unnecessary RV pacing.

urn:iso:std:iso:11073:10101  732352MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_RA_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732353MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_RAS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732354MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_RAP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732355MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_PAC_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732356MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_V_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732357MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_VS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732358MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_VP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732359MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_RV_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732360MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_RVS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732361MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_RVP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732362MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_LV_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732363MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_LVS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732364MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_LVP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732365MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_PVC_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732366MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_ANY_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732367MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_LA_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732368MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_LAS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732369MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_LAP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732370MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_A_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732371MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_AS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732372MDC_IDC_SET_LEADCHNL_RA_BLANKING_AFTER_AP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732384MDC_IDC_SET_LEADCHNL_RV_BLANKING_AFTER_RA_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732385MDC_IDC_SET_LEADCHNL_RV_BLANKING_AFTER_RAS_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732386MDC_IDC_SET_LEADCHNL_RV_BLANKING_AFTER_RAP_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.

urn:iso:std:iso:11073:10101  732387MDC_IDC_SET_LEADCHNL_RV_BLANKING_AFTER_PAC_HIGH

The high setting for pacemaker blanking.

A pacemaker will mark and handle sensed events inside the refractory interval as refractory events. Refractory senses are usually ignored for the brady pacemaker timing but may still be used for tachycardia detection whereas a sensed event inside the blanking interval will usually be fully ignored by the device.


Description of the above table(s).