CardX - Cardiac Implantable Electronic Devices, published by HL7 International / Clinical Interoperability Council. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/CardX-CIED/ and changes regularly. See the Directory of published versions
Page standards status: Trial-use | Maturity Level: 2 |
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="CIEDconnectivity"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: CodeSystem CIEDconnectivity</b></p><a name="CIEDconnectivity"> </a><a name="hcCIEDconnectivity"> </a><p>This case-sensitive code system <code>http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity</code> defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style="white-space:nowrap">connectivity-status<a name="CIEDconnectivity-connectivity-status"> </a></td><td>Connectivity status</td><td>The overall system connectivity status as calculated by the CIED manufacturer.</td></tr><tr><td style="white-space:nowrap">connectivity-modifier<a name="CIEDconnectivity-connectivity-modifier"> </a></td><td>Connectivity modifier</td><td>Additional modifiers to connectivity status as calculated by the CIED manufacturer.</td></tr><tr><td style="white-space:nowrap">setup-not-completed<a name="CIEDconnectivity-setup-not-completed"> </a></td><td>Setup not completed</td><td>Device/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association.</td></tr><tr><td style="white-space:nowrap">not-applicable<a name="CIEDconnectivity-not-applicable"> </a></td><td>N/A</td><td>Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations.</td></tr><tr><td style="white-space:nowrap">connected<a name="CIEDconnectivity-connected"> </a></td><td>Connected</td><td>Communication has been successful within the expected time period.</td></tr><tr><td style="white-space:nowrap">disconnected<a name="CIEDconnectivity-disconnected"> </a></td><td>Disconnected</td><td>Communication has not occurred within the expected time period.</td></tr><tr><td style="white-space:nowrap">suspended<a name="CIEDconnectivity-suspended"> </a></td><td>Suspended</td><td>Patient has been temporarily removed from the disconnected state. This is not intended to be an actionable status.</td></tr><tr><td style="white-space:nowrap">inactive<a name="CIEDconnectivity-inactive"> </a></td><td>Inactive</td><td>Patient has been permanently removed from the disconnected status.</td></tr><tr><td style="white-space:nowrap">unenrolled<a name="CIEDconnectivity-unenrolled"> </a></td><td>Unenrolled</td><td>Patient has been unenrolled from remote monitoring or remote monitoring has been discontinued.</td></tr><tr><td style="white-space:nowrap">transferred<a name="CIEDconnectivity-transferred"> </a></td><td>Transferred</td><td>The patient has been transferred to another remote monitoring clinic.</td></tr><tr><td style="white-space:nowrap">last-cied-connectivity-time<a name="CIEDconnectivity-last-cied-connectivity-time"> </a></td><td>Last CIED to monitor communication</td><td>The timestamp of the most recent communication between the CIED and monitor.</td></tr><tr><td style="white-space:nowrap">last-monitor-connectivity-time<a name="CIEDconnectivity-last-monitor-connectivity-time"> </a></td><td>Last monitor to remote monitoring software communication</td><td>The timestamp of the most recent communication from the monitor to the remote monitoring platform.</td></tr><tr><td style="white-space:nowrap">next-cied-connectivity-date<a name="CIEDconnectivity-next-cied-connectivity-date"> </a></td><td>Next CIED to monitor communication</td><td>The timestamp of the next expected communication between the CIED and monitor.</td></tr><tr><td style="white-space:nowrap">next-monitor-connectivity-date<a name="CIEDconnectivity-next-monitor-connectivity-date"> </a></td><td>Next monitor to remote monitoring software communication</td><td>The timestamp of the next expected communication from the monitor to the remote monitoring platform.</td></tr><tr><td style="white-space:nowrap">last-interrogation-date<a name="CIEDconnectivity-last-interrogation-date"> </a></td><td>Last remote device interrogation date</td><td>The date of the most recent remote device interrogation with a personal monitor.</td></tr><tr><td style="white-space:nowrap">next-interrogation-date<a name="CIEDconnectivity-next-interrogation-date"> </a></td><td>Next scheduled remote device interrogation date</td><td>The date of the next scheduled remote device interrogation.</td></tr><tr><td style="white-space:nowrap">next-secondary-interrogation-date<a name="CIEDconnectivity-next-secondary-interrogation-date"> </a></td><td>Next scheduled remote device interrogation date, secondary clinic</td><td>The date of the next scheduled remote device interrogation by the secondary clinic for patients who are dual-managed.</td></tr><tr><td style="white-space:nowrap">observation-cied-connectivity<a name="CIEDconnectivity-observation-cied-connectivity"> </a></td><td>CIED connectivity</td><td>FHIR observation constrained to the CardX CIED connectivity profile.</td></tr><tr><td style="white-space:nowrap">bedside-device<a name="CIEDconnectivity-bedside-device"> </a></td><td>Bedside Monitor</td><td>Standalone device, not intended to provide monitoring while on the go.</td></tr><tr><td style="white-space:nowrap">mobile-monitor<a name="CIEDconnectivity-mobile-monitor"> </a></td><td>Mobile App</td><td>App based monitor.</td></tr><tr><td style="white-space:nowrap">portable-device<a name="CIEDconnectivity-portable-device"> </a></td><td>Portable Device</td><td>Standalone device, with battery capacity to provide monitoring while on the go.</td></tr><tr><td style="white-space:nowrap">connection-interval<a name="CIEDconnectivity-connection-interval"> </a></td><td>Connection interval</td><td>The time interval in days between expected CIED and remote monitoring software communication.</td></tr><tr><td style="white-space:nowrap">expected-time-period<a name="CIEDconnectivity-expected-time-period"> </a></td><td>Expected time period</td><td>The time period in days in which successful communication must take place for the connectivity status to remain connected.</td></tr><tr><td style="white-space:nowrap">status-reason<a name="CIEDconnectivity-status-reason"> </a></td><td>Status reason</td><td>Text describing reasons why the patient may be listed at a given status and/or modifier.</td></tr><tr><td style="white-space:nowrap">status-guidance<a name="CIEDconnectivity-status-guidance"> </a></td><td>Status guidance</td><td>Text describing steps to get the patient to a connected status.</td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="cic"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
<valueInteger value="2">
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
<valueCanonical
value="http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied"/>
</extension>
</valueInteger>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
<valueCode value="trial-use">
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
<valueCanonical
value="http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied"/>
</extension>
</valueCode>
</extension>
<url value="http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CIEDconnectivity"/>
<version value="1.0.0-ballot"/>
<name value="CIEDconnectivity"/>
<title value="CIED Connectivity Status Values"/>
<status value="active"/>
<experimental value="false"/>
<date value="2025-07-30T17:59:28+00:00"/>
<publisher value="HL7 International / Clinical Interoperability Council"/>
<contact>
<name value="HL7 International / Clinical Interoperability Council"/>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/cic"/>
</telecom>
<telecom>
<system value="email"/>
<value value="ciclist@lists.hl7.org"/>
</telecom>
</contact>
<description
value="Codes system for CIED connectivity and monitor device types"/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
<display value="World"/>
</coding>
</jurisdiction>
<caseSensitive value="true"/>
<content value="complete"/>
<count value="25"/>
<concept>
<code value="connectivity-status"/>
<display value="Connectivity status"/>
<definition
value="The overall system connectivity status as calculated by the CIED manufacturer."/>
</concept>
<concept>
<code value="connectivity-modifier"/>
<display value="Connectivity modifier"/>
<definition
value="Additional modifiers to connectivity status as calculated by the CIED manufacturer."/>
</concept>
<concept>
<code value="setup-not-completed"/>
<display value="Setup not completed"/>
<definition
value="Device/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association."/>
</concept>
<concept>
<code value="not-applicable"/>
<display value="N/A"/>
<definition
value="Connectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations."/>
</concept>
<concept>
<code value="connected"/>
<display value="Connected"/>
<definition
value="Communication has been successful within the expected time period."/>
</concept>
<concept>
<code value="disconnected"/>
<display value="Disconnected"/>
<definition
value="Communication has not occurred within the expected time period."/>
</concept>
<concept>
<code value="suspended"/>
<display value="Suspended"/>
<definition
value="Patient has been temporarily removed from the disconnected state. This is not intended to be an actionable status."/>
</concept>
<concept>
<code value="inactive"/>
<display value="Inactive"/>
<definition
value="Patient has been permanently removed from the disconnected status."/>
</concept>
<concept>
<code value="unenrolled"/>
<display value="Unenrolled"/>
<definition
value="Patient has been unenrolled from remote monitoring or remote monitoring has been discontinued."/>
</concept>
<concept>
<code value="transferred"/>
<display value="Transferred"/>
<definition
value="The patient has been transferred to another remote monitoring clinic."/>
</concept>
<concept>
<code value="last-cied-connectivity-time"/>
<display value="Last CIED to monitor communication"/>
<definition
value="The timestamp of the most recent communication between the CIED and monitor."/>
</concept>
<concept>
<code value="last-monitor-connectivity-time"/>
<display
value="Last monitor to remote monitoring software communication"/>
<definition
value="The timestamp of the most recent communication from the monitor to the remote monitoring platform."/>
</concept>
<concept>
<code value="next-cied-connectivity-date"/>
<display value="Next CIED to monitor communication"/>
<definition
value="The timestamp of the next expected communication between the CIED and monitor."/>
</concept>
<concept>
<code value="next-monitor-connectivity-date"/>
<display
value="Next monitor to remote monitoring software communication"/>
<definition
value="The timestamp of the next expected communication from the monitor to the remote monitoring platform."/>
</concept>
<concept>
<code value="last-interrogation-date"/>
<display value="Last remote device interrogation date"/>
<definition
value="The date of the most recent remote device interrogation with a personal monitor."/>
</concept>
<concept>
<code value="next-interrogation-date"/>
<display value="Next scheduled remote device interrogation date"/>
<definition
value="The date of the next scheduled remote device interrogation."/>
</concept>
<concept>
<code value="next-secondary-interrogation-date"/>
<display
value="Next scheduled remote device interrogation date, secondary clinic"/>
<definition
value="The date of the next scheduled remote device interrogation by the secondary clinic for patients who are dual-managed."/>
</concept>
<concept>
<code value="observation-cied-connectivity"/>
<display value="CIED connectivity"/>
<definition
value="FHIR observation constrained to the CardX CIED connectivity profile."/>
</concept>
<concept>
<code value="bedside-device"/>
<display value="Bedside Monitor"/>
<definition
value="Standalone device, not intended to provide monitoring while on the go."/>
</concept>
<concept>
<code value="mobile-monitor"/>
<display value="Mobile App"/>
<definition value="App based monitor."/>
</concept>
<concept>
<code value="portable-device"/>
<display value="Portable Device"/>
<definition
value="Standalone device, with battery capacity to provide monitoring while on the go."/>
</concept>
<concept>
<code value="connection-interval"/>
<display value="Connection interval"/>
<definition
value="The time interval in days between expected CIED and remote monitoring software communication."/>
</concept>
<concept>
<code value="expected-time-period"/>
<display value="Expected time period"/>
<definition
value="The time period in days in which successful communication must take place for the connectivity status to remain connected."/>
</concept>
<concept>
<code value="status-reason"/>
<display value="Status reason"/>
<definition
value="Text describing reasons why the patient may be listed at a given status and/or modifier."/>
</concept>
<concept>
<code value="status-guidance"/>
<display value="Status guidance"/>
<definition
value="Text describing steps to get the patient to a connected status."/>
</concept>
</CodeSystem>