Validation Results for HL7CzTerminologyImplementationGuide

Generated Tue May 12 10:39:22 UTC 2026, FHIR version 4.0.1 for hl7.fhir.cz.terminology#0.3.0 (canonical = https://hl7.cz/terminology (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.2.7
Publication Code:n/a . PackageId = hl7.fhir.cz.terminology, Canonical = https://hl7.cz/terminology
Realm Check for n/a:
  • n/a
Language Info:Stated Languages: n/a. IG Resource Lang: en. 58 of 65 (89%) of resources have a language. Population Policy: NONE
Publication Request:
package-idhl7.fhir.cz.terminology
version0.3.0
pathhttps://hl7.cz/terminology/0.3.0
Pub-Modemilestone
statusrelease
Release-Labelrelease
Sequence (Group)Release 1 (current: 'Release 1', others = n/a)
descThis is a second release of the Czech FHIR Terminology package.
RelatedIgs(None Found)
  • This is not the first publication, so first must not be true
  • Publication request category found (not allowed after first publication
  • Publication request title found (not allowed after first publication)
  • Publication request introduction found (not allowed after first publication)
  • Publication request ci-build found (not allowed after first publication)
Supressed Messages:33 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.fhir.cz.terminology0.3.0R4https://hl7.cz/terminology
... hl7.terminology.r47.1.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0
.... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0
... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0 (as above)
... hl7.fhir.uv.tools.r41.1.2 MR4http://hl7.org/fhir/toolshttp://hl7.org/fhir/tools/1.1.2Internal Dependency
Templates: hl7.fhir.cz.empty.template#0.0.2 -> fhir2.base.template#current
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4, http://tx.hl7europe.eu/r4, https://tx.fhir.org/r4, https://tx.hl7europe.eu/r4 (details)
HTA Analysis:2 issues
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 0.2.0
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 3, warn = 21, info = 0, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors000
/scratch/repo/fsh-generated/includes/fsh-link-references000
/scratch/repo/fsh-generated/includes/menu000
/scratch/repo/fsh-generated/resources/CodeSystem-absent-unknown-uv-ips-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-administrative-gender-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-allergy-intolerance-category-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-allergy-intolerance-criticality-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-coverage-selfpay-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-dlp-atc000
/scratch/repo/fsh-generated/resources/CodeSystem-dlp-formy000
/scratch/repo/fsh-generated/resources/CodeSystem-dlp-lecivelatky000
/scratch/repo/fsh-generated/resources/CodeSystem-dlp-lecivepripravky000
/scratch/repo/fsh-generated/resources/CodeSystem-drzar000
/scratch/repo/fsh-generated/resources/CodeSystem-healthInsuranceCompanyCode000
/scratch/repo/fsh-generated/resources/CodeSystem-mkn-10000
/scratch/repo/fsh-generated/resources/CodeSystem-nclp-NCLPMAT000
/scratch/repo/fsh-generated/resources/CodeSystem-nrzp-povolani000
/scratch/repo/fsh-generated/resources/CodeSystem-nzis-NahradyZaZdravotniPeci000
/scratch/repo/fsh-generated/resources/CodeSystem-v2-0131-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-v3-ActCode-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-v3-NullFlavor-cz000
/scratch/repo/fsh-generated/resources/CodeSystem-v3-RoleCode-cz000
/scratch/repo/fsh-generated/resources/ImplementationGuide-hl7.fhir.cz.terminology000
/scratch/repo/fsh-generated/resources/ValueSet-AllergenWithExceptions010
/scratch/repo/fsh-generated/resources/ValueSet-MedicalDeviceWithExceptions010
/scratch/repo/fsh-generated/resources/ValueSet-OP-NS000
/scratch/repo/fsh-generated/resources/ValueSet-administrative-gender-cz000
/scratch/repo/fsh-generated/resources/ValueSet-allergy-intolerance-category-cz000
/scratch/repo/fsh-generated/resources/ValueSet-allergy-intolerance-criticality-cz000
/scratch/repo/fsh-generated/resources/ValueSet-condition-cz100
/scratch/repo/fsh-generated/resources/ValueSet-contact-and-relationship-cz000
/scratch/repo/fsh-generated/resources/ValueSet-contactrole-cz000
/scratch/repo/fsh-generated/resources/ValueSet-cz-coverage-type000
/scratch/repo/fsh-generated/resources/ValueSet-cz-logo-mime-types000
/scratch/repo/fsh-generated/resources/ValueSet-cz-sitequalifier020
/scratch/repo/fsh-generated/resources/ValueSet-cz-specimen-laterality020
/scratch/repo/fsh-generated/resources/ValueSet-cz-specimenAdditive020
/scratch/repo/fsh-generated/resources/ValueSet-cz-specimencontainer110
/scratch/repo/fsh-generated/resources/ValueSet-dlp-atc000
/scratch/repo/fsh-generated/resources/ValueSet-dlp-formy000
/scratch/repo/fsh-generated/resources/ValueSet-dlp-lecivelatky000
/scratch/repo/fsh-generated/resources/ValueSet-dlp-lecivepripravky000
/scratch/repo/fsh-generated/resources/ValueSet-document-category000
/scratch/repo/fsh-generated/resources/ValueSet-drzar000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownAllergy-cz000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownDevice-cz000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIAllergenNoDrug-cz020
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIExceptionalValue-cz000
/scratch/repo/fsh-generated/resources/ValueSet-eHDSIReactionAllergy020
/scratch/repo/fsh-generated/resources/ValueSet-healthInsuranceCompanyCode000
/scratch/repo/fsh-generated/resources/ValueSet-idcard-uri000
/scratch/repo/fsh-generated/resources/ValueSet-imaging-document-types000
/scratch/repo/fsh-generated/resources/ValueSet-lab-document-types000
/scratch/repo/fsh-generated/resources/ValueSet-lab-specimenType020
/scratch/repo/fsh-generated/resources/ValueSet-medical-device110
/scratch/repo/fsh-generated/resources/ValueSet-medical-document-type000
/scratch/repo/fsh-generated/resources/ValueSet-mkn-10000
/scratch/repo/fsh-generated/resources/ValueSet-nclpmat000
/scratch/repo/fsh-generated/resources/ValueSet-nrzp-povolani-vs000
/scratch/repo/fsh-generated/resources/ValueSet-nursing-document-type000
/scratch/repo/fsh-generated/resources/ValueSet-nzis-nahradyzazdravotnipeci000
/scratch/repo/fsh-generated/resources/ValueSet-orphanet-rare-diseases000
/scratch/repo/fsh-generated/resources/ValueSet-passport-NS000
/scratch/repo/fsh-generated/resources/ValueSet-passport-uri000
/scratch/repo/fsh-generated/resources/ValueSet-personal-relationship-cz000
/scratch/repo/fsh-generated/resources/ValueSet-referralorder-types020
/scratch/repo/fsh-generated/resources/ValueSet-registering-provider-service-type-cz020
/scratch/repo/fsh-generated/resources/ValueSet-search-document-types010
/scratch/repo/input/pagecontent/artifactsPage000
/scratch/repo/input/pagecontent/codeSystems000
/scratch/repo/input/pagecontent/index000
/scratch/repo/input/pagecontent/terminologies000
/scratch/repo/input/pagecontent/valueSets000
/scratch/repo/temp/pages/_includes/artifacts000
/scratch/repo/template/config000
/scratch/repo/template/config/_config000

n/a Show Validation Information


fsh-generated/includes/fsh-link-references.md Show Validation Information (0)


fsh-generated/includes/menu.xml Show Validation Information (0)


fsh-generated/resources/CodeSystem-absent-unknown-uv-ips-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-administrative-gender-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-allergy-intolerance-category-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-allergy-intolerance-criticality-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-coverage-selfpay-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-dlp-atc.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-dlp-formy.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-dlp-lecivelatky.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-dlp-lecivepripravky.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-drzar.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-healthInsuranceCompanyCode.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-mkn-10.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-nclp-NCLPMAT.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-nrzp-povolani.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-nzis-NahradyZaZdravotniPeci.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-v2-0131-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-v3-ActCode-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-v3-NullFlavor-cz.json Show Validation Information (1)


fsh-generated/resources/CodeSystem-v3-RoleCode-cz.json Show Validation Information (1)


fsh-generated/resources/ImplementationGuide-hl7.fhir.cz.terminology.json Show Validation Information (1)


fsh-generated/resources/ValueSet-AllergenWithExceptions.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.where(id = 'AllergenWithExceptions')warningUnable to expand included value set 'https://ncez.mzcr.cz/terminology/ValueSet/eHDSIAllergenNoDrug-cz': Error from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (and Error from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known) --

fsh-generated/resources/ValueSet-MedicalDeviceWithExceptions.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.where(id = 'MedicalDeviceWithExceptions')warningUnable to expand included value set 'https://ncez.mzcr.cz/terminology/ValueSet/medical-device': Error from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (and Error from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known) --

fsh-generated/resources/ValueSet-OP-NS.json Show Validation Information (1)


fsh-generated/resources/ValueSet-administrative-gender-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-allergy-intolerance-category-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-allergy-intolerance-criticality-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-condition-cz.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[2].filter[0]errorThe value for a filter based on property 'concept' must be a valid code from the system 'http://snomed.info/sct', and '404684003' is not (A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_BAD_FILTER_VALUE_VALID_CODE--

fsh-generated/resources/ValueSet-contact-and-relationship-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-contactrole-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-cz-coverage-type.json Show Validation Information (1)


fsh-generated/resources/ValueSet-cz-logo-mime-types.json Show Validation Information (1)


fsh-generated/resources/ValueSet-cz-sitequalifier.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet.where(id = 'cz-sitequalifier')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-cz-specimen-laterality.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet​.where(id = 'cz-specimen-laterality')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-cz-specimenAdditive.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet​.where(id = 'cz-specimenAdditive')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-cz-specimencontainer.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0].filter[0]errorThe value for a filter based on property 'concept' must be a valid code from the system 'http://snomed.info/sct', and '706041008' is not (A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_BAD_FILTER_VALUE_VALID_CODE--
ValueSet​.where(id = 'cz-specimencontainer')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-dlp-atc.json Show Validation Information (1)


fsh-generated/resources/ValueSet-dlp-formy.json Show Validation Information (1)


fsh-generated/resources/ValueSet-dlp-lecivelatky.json Show Validation Information (1)


fsh-generated/resources/ValueSet-dlp-lecivepripravky.json Show Validation Information (1)


fsh-generated/resources/ValueSet-document-category.json Show Validation Information (1)


fsh-generated/resources/ValueSet-drzar.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownAllergy-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAbsentOrUnknownDevice-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIAllergenNoDrug-cz.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet​.where(id = 'eHDSIAllergenNoDrug-cz')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-eHDSIExceptionalValue-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-eHDSIReactionAllergy.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet​.where(id = 'eHDSIReactionAllergy')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-healthInsuranceCompanyCode.json Show Validation Information (1)


fsh-generated/resources/ValueSet-idcard-uri.json Show Validation Information (1)


fsh-generated/resources/ValueSet-imaging-document-types.json Show Validation Information (1)


fsh-generated/resources/ValueSet-lab-document-types.json Show Validation Information (1)


fsh-generated/resources/ValueSet-lab-specimenType.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet.where(id = 'lab-specimenType')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-medical-device.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0].filter[0]errorThe value for a filter based on property 'concept' must be a valid code from the system 'http://snomed.info/sct', and '49062001' is not (A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_BAD_FILTER_VALUE_VALID_CODE--
ValueSet.where(id = 'medical-device')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-medical-document-type.json Show Validation Information (1)


fsh-generated/resources/ValueSet-mkn-10.json Show Validation Information (1)


fsh-generated/resources/ValueSet-nclpmat.json Show Validation Information (1)


fsh-generated/resources/ValueSet-nrzp-povolani-vs.json Show Validation Information (1)


fsh-generated/resources/ValueSet-nursing-document-type.json Show Validation Information (1)


fsh-generated/resources/ValueSet-nzis-nahradyzazdravotnipeci.json Show Validation Information (1)


fsh-generated/resources/ValueSet-orphanet-rare-diseases.json Show Validation Information (1)


fsh-generated/resources/ValueSet-passport-NS.json Show Validation Information (1)


fsh-generated/resources/ValueSet-passport-uri.json Show Validation Information (1)


fsh-generated/resources/ValueSet-personal-relationship-cz.json Show Validation Information (1)


fsh-generated/resources/ValueSet-referralorder-types.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[1]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet​.where(id = 'referralorder-types')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-registering-provider-service-type-cz.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]warningUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known) VALUESET_UNC_SYSTEM_WARNING--
ValueSet​.where(id = 'registering-provider-service-type-cz')warningError from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known (from server, see log) --

fsh-generated/resources/ValueSet-search-document-types.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.where(id = 'search-document-types')warningUnable to expand included value set 'https://ncez.mzcr.cz/terminology/ValueSet/imaging-document-types': The value set 'https://ncez.mzcr.cz/terminology/ValueSet/imaging-document-types|0.3.0' expansion has too many codes to produce (>1000) (and Error from https://tx.hl7europe.eu/r4: Error: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the value set cannot be expanded. No versions of this code system are known) --

input/pagecontent/artifactsPage.md Show Validation Information (0)


input/pagecontent/codeSystems.md Show Validation Information (0)


input/pagecontent/index.md Show Validation Information (0)


input/pagecontent/terminologies.md Show Validation Information (0)


input/pagecontent/valueSets.md Show Validation Information (0)


temp/pages/_includes/artifacts.xml Show Validation Information (0)


template/config Show Validation Information (0)


template/config/_config.yml Show Validation Information (0)

Suppressed Messages (Warnings, hints, broken links)

All SNOMED-CT concepts use preferred terms consistently - FSN tags in the warning are from the terminology server, not from our value sets

Code system properties

Expansion parameters fragment not used

Ignore HL7 terminology warning on missing definition of the HL7 code system concepts

Known terminology issue - no Code System definition found

Known wrong display names - terminology issue

Reference to deprecated ValueSet and no code for #CZ

Suppress information on subset expansion of large value sets

Errors sorted by type


VALUESET_BAD_FILTER_VALUE_VALID_CODE

fsh-generated/resources/ValueSet-condition-cz.jsonThe value for a filter based on property 'concept' must be a valid code from the system 'http://snomed.info/sct', and '404684003' is not (A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-cz-specimencontainer.jsonThe value for a filter based on property 'concept' must be a valid code from the system 'http://snomed.info/sct', and '706041008' is not (A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-medical-device.jsonThe value for a filter based on property 'concept' must be a valid code from the system 'http://snomed.info/sct', and '49062001' is not (A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--

VALUESET_UNC_SYSTEM_WARNING

fsh-generated/resources/ValueSet-cz-sitequalifier.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-cz-specimen-laterality.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-cz-specimenAdditive.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-eHDSIAllergenNoDrug-cz.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-eHDSIReactionAllergy.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-lab-specimenType.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-referralorder-types.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--
fsh-generated/resources/ValueSet-registering-provider-service-type-cz.jsonUnknown System 'http://snomed.info/sct' specified, so Concepts and Filters can't be checked (Details: A definition for CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/11000279109' could not be found, so the code cannot be validated. No versions of this code system are known)--