Clinical Practice Guidelines (CPG) on EBMonFHIR
1.0.2 - ci-build
Clinical Practice Guidelines (CPG) on EBMonFHIR, published by Universitätsmedizin Greifswald. This guide is not an authorized publication; it is the continuous build for version 1.0.2 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/CEOsys/cpg-on-ebm-on-fhir/ and changes regularly. See the Directory of published versions
Defining URL: | https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/recommendation-justification |
Version: | 0.1.0 |
Name: | RecommendationJustification |
Title: | Recommendation Justification |
Status: | Draft as of 2022-03-04 |
Definition: | Justification of a clinical guideline recommendation through the underlying evidence and their ratings |
Publisher: | Netzwerk Universitätsmedizin (NUM), |
Source Resource: | XML / JSON / Turtle |
The official URL for this profile is:
https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/recommendation-justification
This profile of a FHIR ArtifactAssessment is derived from the ArtifactAssessment FHIR resource.
Description of Profiles, Differentials, Snapshots and how the different presentations work.
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
ArtifactAssessment | 0..* | ArtifactAssessment | Adds metadata-supported comments, classifiers or ratings related to a Resource | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | SΣ | 1..1 | Meta | Metadata about the resource | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
versionId | Σ | 0..1 | id | Version specific identifier | ||||
lastUpdated | Σ | 0..1 | instant | When the resource version last changed | ||||
source | SΣ | 0..1 | uri | Identifies where the resource comes from | ||||
profile | SΣ | 1..* | canonical(StructureDefinition) | Profiles this resource claims to conform to | ||||
security | Σ | 0..* | Coding | Security Labels applied to this resource Binding: AllSecurityLabels (extensible): Security Labels from the Healthcare Privacy and Security Classification System. | ||||
tag | Σ | 0..* | Coding | Tags applied to this resource Binding: CommonTags (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: AllLanguages (required): IETF language tag for a human language
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
Slices for extension | 2..* | Extension | Extension Slice: Unordered, Open by value:url | |||||
version | S | 1..1 | string | Version URL: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ceosys-extension-artifact-assessment-version | ||||
publicationStatus | S | 1..1 | code | Publication status URL: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ceosys-extension-artifact-assessment-publication-status Binding: PublicationStatus (required) | ||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored | ||||
identifier | Σ | 0..* | Identifier | Additional identifier for the artifact assessment | ||||
title | Σ | 0..1 | string | A short title for the assessment for use in displaying and selecting | ||||
citeAs[x] | 0..1 | How to cite the comment or rating | ||||||
citeAsReference | Reference(Citation) | |||||||
citeAsMarkdown | markdown | |||||||
date | Σ | 1..1 | dateTime | Date last changed | ||||
copyright | 0..1 | markdown | Use and/or publishing restrictions | |||||
approvalDate | 0..1 | date | When the artifact assessment was approved by publisher | |||||
lastReviewDate | Σ | 0..1 | date | When the artifact assessment was last reviewed by the publisher | ||||
artifact[x] | Σ | 1..1 | Reference(Recommendation Plan) | The artifact assessed, commented upon or rated | ||||
Slices for content | S | 2..* | BackboneElement | Comment, classifier, or rating content Slice: Unordered, Closed by value:type | ||||
content:All Slices | Content/Rules for all slices | |||||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 0..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 0..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) | |||||
classifier | 0..* | CodeableConcept | Rating, classifier, or assessment Binding: EvidenceCertaintyRating (example) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:strength | S | 1..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: strength | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Strength of recommendation | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Recommendation Strength (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:consensus | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consensus | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Consensus | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Consensus (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:benefitAndHarms | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: benefit-and-harms | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Benefit and harms | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Benefit And Harms (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:certaintyOfEvidence | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: Overall | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Overall certainty | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Certainty Of Evidence (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:preferenceAndValues | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: preference-and-values | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Preference and values | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Preference And Values (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:resources | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: resources | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Resources | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Resources (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:equity | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: equity | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Equity | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Equity (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:acceptability | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: acceptability | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Acceptability | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Acceptability (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:feasibility | S | 0..1 | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: rating | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: feasibility | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Feasibility | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Feasibility (required) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | 0..* | RelatedArtifact | Additional information | |||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:evidenceRating | S | 0..* | BackboneElement | Comment, classifier, or rating content | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: container | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: certainty-of-evidence-rating | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Certainty of evidence rating | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 0..* | CodeableConcept | Rating, classifier, or assessment Binding: EvidenceCertaintyRating (example) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | S | 1..1 | RelatedArtifact | Additional information | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
type | Σ | 1..1 | code | documentation | justification | citation | predecessor | successor | derived-from | depends-on | composed-of | part-of | amends | amended-with | appends | appended-with | cites | cited-by | comments-on | comment-in | contains | contained-in | corrects | correction-in | replaces | replaced-with | retracts | retracted-by | signs | similar-to | supports | supported-with | transforms | transformed-into | transformed-with | documents | specification-of | created-with | cite-as Binding: RelatedArtifactType (required): The type of relationship to the related artifact. Required Pattern: justification | ||||
classifier | Σ | 1..1 | CodeableConcept | Additional classifiers Binding: CitationArtifactClassifier (example): Additional classifiers for the related artifact. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: certainty-of-evidence-rating | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Certainty of evidence rating | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
label | Σ | 0..1 | string | Short label | ||||
display | Σ | 0..1 | string | Brief description of the related artifact | ||||
citation | Σ | 0..1 | markdown | Bibliographic citation for the artifact | ||||
document | Σ | 0..1 | Attachment | What document is being referenced | ||||
resource | Σ | 0..1 | canonical(Resource) | What artifact is being referenced | ||||
resourceReference | SΣ | 1..1 | Reference(Certainty of Evidence Rating) | What artifact, if not a conformance resource | ||||
publicationStatus | Σ | 0..1 | code | draft | active | retired | unknown Binding: PublicationStatus (required): Publication status of an artifact being referred to. | ||||
publicationDate | Σ | 0..1 | date | Date of publication of the artifact being referred to | ||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
content:netEffect | 0..1 | BackboneElement | Comment, classifier, or rating content | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Binding: ArtifactAssessmentInformationType (required) Required Pattern: container | |||||
summary | 0..1 | markdown | Brief summary of the content | |||||
type | 1..1 | CodeableConcept | What type of content Binding: EvidenceCertaintyType (example) Required Pattern: At least the following | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: net-effect | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Net effect | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
classifier | 0..* | CodeableConcept | Rating, classifier, or assessment Binding: EvidenceCertaintyRating (example) | |||||
quantity | 0..1 | Quantity | Quantitative rating | |||||
author | 0..1 | Reference(Patient | Practitioner | PractitionerRole | Organization | Device) | Who authored the content | |||||
path | 0..* | uri | What the comment is directed to | |||||
relatedArtifact | S | 1..1 | RelatedArtifact | Additional information | ||||
id | 0..1 | id | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
type | Σ | 1..1 | code | documentation | justification | citation | predecessor | successor | derived-from | depends-on | composed-of | part-of | amends | amended-with | appends | appended-with | cites | cited-by | comments-on | comment-in | contains | contained-in | corrects | correction-in | replaces | replaced-with | retracts | retracted-by | signs | similar-to | supports | supported-with | transforms | transformed-into | transformed-with | documents | specification-of | created-with | cite-as Binding: RelatedArtifactType (required): The type of relationship to the related artifact. Required Pattern: supported-with | ||||
classifier | Σ | 1..1 | CodeableConcept | Additional classifiers Binding: CitationArtifactClassifier (example): Additional classifiers for the related artifact. Required Pattern: At least the following | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |||||
version | 0..1 | string | Version of the system - if relevant | |||||
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: net-effect | |||||
display | 1..1 | string | Representation defined by the system Fixed Value: Net effect | |||||
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |||||
text | 0..1 | string | Plain text representation of the concept | |||||
label | Σ | 0..1 | string | Short label | ||||
display | Σ | 0..1 | string | Brief description of the related artifact | ||||
citation | Σ | 0..1 | markdown | Bibliographic citation for the artifact | ||||
document | Σ | 0..1 | Attachment | What document is being referenced | ||||
resource | Σ | 0..1 | canonical(Resource) | What artifact is being referenced | ||||
resourceReference | SΣ | 1..1 | Reference(Net Effect Estimate) | What artifact, if not a conformance resource | ||||
publicationStatus | Σ | 0..1 | code | draft | active | retired | unknown Binding: PublicationStatus (required): Publication status of an artifact being referred to. | ||||
publicationDate | Σ | 0..1 | date | Date of publication of the artifact being referred to | ||||
freeToShare | 0..1 | boolean | Acceptable to publicly share the resource content | |||||
component | 0..* | See content (ArtifactAssessment) | Contained content | |||||
workflowStatus | Σ | 0..1 | code | submitted | triaged | waiting-for-input | resolved-no-change | resolved-change-required | deferred | duplicate | applied | published | entered-in-error Binding: ArtifactAssessmentWorkflowStatus (required) | ||||
disposition | Σ | 0..1 | code | unresolved | not-persuasive | persuasive | persuasive-with-modification | not-persuasive-with-modification Binding: ArtifactAssessmentDisposition (required) | ||||
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
ArtifactAssessment | 0..* | ArtifactAssessment | Adds metadata-supported comments, classifiers or ratings related to a Resource | |
meta | Σ | 1..1 | Meta | Metadata about the resource |
source | Σ | 0..1 | uri | Identifies where the resource comes from |
profile | Σ | 1..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
Slices for extension | Content/Rules for all slices | |||
version | 1..1 | string | Version URL: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ceosys-extension-artifact-assessment-version | |
publicationStatus | 1..1 | code | Publication status URL: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ceosys-extension-artifact-assessment-publication-status Binding: PublicationStatus (required) | |
Slices for content | 2..* | BackboneElement | Comment, classifier, or rating content Slice: Unordered, Closed by value:type | |
content:strength | 1..1 | BackboneElement | Comment, classifier, or rating content | |
content:consensus | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:benefitAndHarms | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:certaintyOfEvidence | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:preferenceAndValues | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:resources | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:equity | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:acceptability | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:feasibility | 0..1 | BackboneElement | Comment, classifier, or rating content | |
content:evidenceRating | 0..* | BackboneElement | Comment, classifier, or rating content | |
relatedArtifact | 1..1 | RelatedArtifact | Additional information | |
resourceReference | Σ | 1..1 | Reference(Certainty of Evidence Rating) | What artifact, if not a conformance resource |
content:netEffect | 0..1 | BackboneElement | Comment, classifier, or rating content | |
relatedArtifact | 1..1 | RelatedArtifact | Additional information | |
resourceReference | Σ | 1..1 | Reference(Net Effect Estimate) | What artifact, if not a conformance resource |
Documentation for this format |
This structure is derived from ArtifactAssessment
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
ArtifactAssessment | ArtifactAssessment | |||
meta | S | 1..1 | Meta | Metadata about the resource |
source | S | 0..1 | uri | Identifies where the resource comes from |
profile | S | 1..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
Slices for extension | 2..* | Extension | Extension Slice: Unordered, Open by value:url | |
version | S | 1..1 | string | Version URL: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ceosys-extension-artifact-assessment-version |
publicationStatus | S | 1..1 | code | Publication status URL: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/StructureDefinition/ceosys-extension-artifact-assessment-publication-status Binding: PublicationStatus (required) |
date | 1..1 | dateTime | Date last changed | |
artifact[x] | 1..1 | Reference(Recommendation Plan) | The artifact assessed, commented upon or rated | |
Slices for content | S | 2..* | BackboneElement | Comment, classifier, or rating content Slice: Unordered, Closed by value:type |
content:strength | S | 1..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: strength | |
display | 1..1 | string | Representation defined by the system Fixed Value: Strength of recommendation | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Recommendation Strength (required) | |
content:consensus | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: consensus | |
display | 1..1 | string | Representation defined by the system Fixed Value: Consensus | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Consensus (required) | |
content:benefitAndHarms | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: benefit-and-harms | |
display | 1..1 | string | Representation defined by the system Fixed Value: Benefit and harms | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Benefit And Harms (required) | |
content:certaintyOfEvidence | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: Overall | |
display | 1..1 | string | Representation defined by the system Fixed Value: Overall certainty | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Certainty Of Evidence (required) | |
content:preferenceAndValues | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: preference-and-values | |
display | 1..1 | string | Representation defined by the system Fixed Value: Preference and values | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Preference And Values (required) | |
content:resources | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: resources | |
display | 1..1 | string | Representation defined by the system Fixed Value: Resources | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Resources (required) | |
content:equity | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: equity | |
display | 1..1 | string | Representation defined by the system Fixed Value: Equity | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Equity (required) | |
content:acceptability | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: acceptability | |
display | 1..1 | string | Representation defined by the system Fixed Value: Acceptability | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Acceptability (required) | |
content:feasibility | S | 0..1 | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: rating | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/cs-evidence-to-decision-certainty-type | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: feasibility | |
display | 1..1 | string | Representation defined by the system Fixed Value: Feasibility | |
classifier | 1..1 | CodeableConcept | Rating, classifier, or assessment Binding: Rating Feasibility (required) | |
content:evidenceRating | S | 0..* | BackboneElement | Comment, classifier, or rating content |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: container | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: certainty-of-evidence-rating | |
display | 1..1 | string | Representation defined by the system Fixed Value: Certainty of evidence rating | |
relatedArtifact | S | 1..1 | RelatedArtifact | Additional information |
type | 1..1 | code | documentation | justification | citation | predecessor | successor | derived-from | depends-on | composed-of | part-of | amends | amended-with | appends | appended-with | cites | cited-by | comments-on | comment-in | contains | contained-in | corrects | correction-in | replaces | replaced-with | retracts | retracted-by | signs | similar-to | supports | supported-with | transforms | transformed-into | transformed-with | documents | specification-of | created-with | cite-as Required Pattern: justification | |
classifier | 1..1 | CodeableConcept | Additional classifiers Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: certainty-of-evidence-rating | |
display | 1..1 | string | Representation defined by the system Fixed Value: Certainty of evidence rating | |
resourceReference | S | 1..1 | Reference(Certainty of Evidence Rating) | What artifact, if not a conformance resource |
content:netEffect | 0..1 | BackboneElement | Comment, classifier, or rating content | |
informationType | 1..1 | code | comment | classifier | rating | container | response | change-request Required Pattern: container | |
type | 1..1 | CodeableConcept | What type of content Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: net-effect | |
display | 1..1 | string | Representation defined by the system Fixed Value: Net effect | |
relatedArtifact | S | 1..1 | RelatedArtifact | Additional information |
type | 1..1 | code | documentation | justification | citation | predecessor | successor | derived-from | depends-on | composed-of | part-of | amends | amended-with | appends | appended-with | cites | cited-by | comments-on | comment-in | contains | contained-in | corrects | correction-in | replaces | replaced-with | retracts | retracted-by | signs | similar-to | supports | supported-with | transforms | transformed-into | transformed-with | documents | specification-of | created-with | cite-as Required Pattern: supported-with | |
classifier | 1..1 | CodeableConcept | Additional classifiers Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/CodeSystem/ceosys-code-system | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: net-effect | |
display | 1..1 | string | Representation defined by the system Fixed Value: Net effect | |
resourceReference | S | 1..1 | Reference(Net Effect Estimate) | What artifact, if not a conformance resource |
Documentation for this format |
This structure is derived from ArtifactAssessment
Summary
Mandatory: 9 elements(34 nested mandatory elements)
Must-Support: 20 elements
Structures
This structure refers to these other structures:
Extensions
This structure refers to these extensions:
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron
Path | Conformance | ValueSet / Code | URI |
ArtifactAssessment.meta.security | extensible | AllSecurityLabelshttp://hl7.org/fhir/ValueSet/security-labels from the FHIR Standard | |
ArtifactAssessment.meta.tag | example | CommonTagshttp://hl7.org/fhir/ValueSet/common-tags from the FHIR Standard | |
ArtifactAssessment.language | required | AllLanguageshttp://hl7.org/fhir/ValueSet/all-languages|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content.informationType | required | ArtifactAssessmentInformationTypehttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content.type | example | EvidenceCertaintyTypehttp://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content.classifier | example | EvidenceCertaintyRating (a valid code from Evidence Certainty Rating)http://hl7.org/fhir/ValueSet/certainty-rating from the FHIR Standard | |
ArtifactAssessment.content:strength.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:strength.type | example | Pattern: strength("Strength of recommendation")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:strength.classifier | required | RecommendationStrength (a valid code from Recommendation Strength)https://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/ceosys-vs-recommendation-strength from this IG | |
ArtifactAssessment.content:consensus.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:consensus.type | example | Pattern: consensus("Consensus")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:consensus.classifier | required | RatingConsensushttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-consensus from this IG | |
ArtifactAssessment.content:benefitAndHarms.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:benefitAndHarms.type | example | Pattern: benefit-and-harms("Benefit and harms")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:benefitAndHarms.classifier | required | RatingBenefitAndHarmshttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-benefit-and-harms from this IG | |
ArtifactAssessment.content:certaintyOfEvidence.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:certaintyOfEvidence.type | example | Pattern: Overall("Overall certainty")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:certaintyOfEvidence.classifier | required | RatingCertaintyofEvidencehttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-certainty-of-evidence from this IG | |
ArtifactAssessment.content:preferenceAndValues.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:preferenceAndValues.type | example | Pattern: preference-and-values("Preference and values")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:preferenceAndValues.classifier | required | RatingPreferenceAndValueshttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-preference-and-values from this IG | |
ArtifactAssessment.content:resources.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:resources.type | example | Pattern: resources("Resources")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:resources.classifier | required | RatingResourceshttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-resources from this IG | |
ArtifactAssessment.content:equity.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:equity.type | example | Pattern: equity("Equity")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:equity.classifier | required | RatingEquityhttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-equity from this IG | |
ArtifactAssessment.content:acceptability.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:acceptability.type | example | Pattern: acceptability("Acceptability")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:acceptability.classifier | required | RatingAcceptabilityhttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-acceptability from this IG | |
ArtifactAssessment.content:feasibility.informationType | required | Pattern: ratinghttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:feasibility.type | example | Pattern: feasibility("Feasibility")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:feasibility.classifier | required | RatingFeasibilityhttps://www.netzwerk-universitaetsmedizin.de/fhir/cpg-on-ebm-on-fhir/ValueSet/vs-rating-feasibility from this IG | |
ArtifactAssessment.content:evidenceRating.informationType | required | Pattern: containerhttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:evidenceRating.type | example | Pattern: certainty-of-evidence-rating("Certainty of evidence rating")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:evidenceRating.classifier | example | EvidenceCertaintyRating (a valid code from Evidence Certainty Rating)http://hl7.org/fhir/ValueSet/certainty-rating from the FHIR Standard | |
ArtifactAssessment.content:evidenceRating.relatedArtifact.type | required | Pattern: justificationhttp://hl7.org/fhir/ValueSet/related-artifact-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:evidenceRating.relatedArtifact.classifier | example | Pattern: certainty-of-evidence-rating("Certainty of evidence rating")http://hl7.org/fhir/ValueSet/citation-artifact-classifier from the FHIR Standard | |
ArtifactAssessment.content:evidenceRating.relatedArtifact.publicationStatus | required | PublicationStatushttp://hl7.org/fhir/ValueSet/publication-status|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:netEffect.informationType | required | Pattern: containerhttp://hl7.org/fhir/ValueSet/artifactassessment-information-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:netEffect.type | example | Pattern: net-effect("Net effect")http://hl7.org/fhir/ValueSet/certainty-type from the FHIR Standard | |
ArtifactAssessment.content:netEffect.classifier | example | EvidenceCertaintyRating (a valid code from Evidence Certainty Rating)http://hl7.org/fhir/ValueSet/certainty-rating from the FHIR Standard | |
ArtifactAssessment.content:netEffect.relatedArtifact.type | required | Pattern: supported-withhttp://hl7.org/fhir/ValueSet/related-artifact-type|5.0.0 from the FHIR Standard | |
ArtifactAssessment.content:netEffect.relatedArtifact.classifier | example | Pattern: net-effect("Net effect")http://hl7.org/fhir/ValueSet/citation-artifact-classifier from the FHIR Standard | |
ArtifactAssessment.content:netEffect.relatedArtifact.publicationStatus | required | PublicationStatushttp://hl7.org/fhir/ValueSet/publication-status|5.0.0 from the FHIR Standard | |
ArtifactAssessment.workflowStatus | required | ArtifactAssessmentWorkflowStatushttp://hl7.org/fhir/ValueSet/artifactassessment-workflow-status|5.0.0 from the FHIR Standard | |
ArtifactAssessment.disposition | required | ArtifactAssessmentDispositionhttp://hl7.org/fhir/ValueSet/artifactassessment-disposition|5.0.0 from the FHIR Standard |