FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example Device/and20601bpmonitor (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

AND20601BPMonitor (id = "and20601bpmonitor")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">
  <id value="and20601bpmonitor"/>  
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="and20601bpmonitor"> </a> <a name="hcand20601bpmonitor"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;and20601bpmonitor&quot; </p> </div> <p> <b> identifier</b> : System Identifier/00-09-1F-FF-FE-80-07-3A, Bluetooth Address/00-09-1F-80-07-3A</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td style="display: none">*</td> <td> 39183189818</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1-di">http://hl7.org/fhir/NamingSystem/gs1-di</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> (01)39183189818(21)5091100966</td> <td> unknown</td> </tr> </table> <p> <b> manufacturer</b> : A&amp;D Medical</p> <p> <b> serialNumber</b> : 5091100966</p> <h3> Names</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> Value</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td style="display: none">*</td> <td> AND BP UA-767PBT-C</td> <td> user-friendly-name</td> </tr> </table> <p> <b> modelNumber</b> : UA-767PBT-C</p> <p> <b> type</b> : MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span> </p> <h3> Versions</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> Type</b> </td> <td> <b> Value</b> </td> </tr> <tr> <td style="display: none">*</td> <td> MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532352)</span> </td> <td> 1.0</td> </tr> </table> <h3> ConformsTos</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> Specification</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td style="display: none">*</td> <td> MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528391)</span> </td> <td> 1</td> </tr> </table> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532353)</span> </p> <p> <b> value</b> : 7 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ContinuaPAN#7)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#532354.0)</span> </p> <p> <b> value</b> : Device is Regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#N)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #68220)</span> </p> <p> <b> value</b> : MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532224)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-real-time-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.0)</span> </p> <p> <b> value</b> : real time clock supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-set-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.1)</span> </p> <p> <b> value</b> : setting the time supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-mgr-set-time <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.11)</span> </p> <p> <b> value</b> : manager requested to set the time <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> </div> </text> <identifier> 
  <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> 
        <code value="SYSID"/> 
        <display value="System Identifier"/> 
      </coding> 
  </type> 
  <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> 
  <value value="00-09-1F-FF-FE-80-07-3A"/> 
</identifier> 
 <identifier> 
   <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> 
        <code value="BTMAC"/> 
        <display value="Bluetooth Address"/> 
      </coding> 
    </type> 
   <system value="http://hl7.org/fhir/sid/eui-48"/>  
   <value value="00-09-1F-80-07-3A"/> 
  </identifier>  
  <udiCarrier> 
    <deviceIdentifier value="39183189818"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierHRF value="(01)39183189818(21)5091100966"/> 
    <entryType value="unknown"/> 
  </udiCarrier> 
  <manufacturer value="A&amp;D Medical"/> 
  <serialNumber value="5091100966"/> 
  <name> 
    <value value="AND BP UA-767PBT-C"/> 
    <type value="user-friendly-name"/> 
  </name> 
  <modelNumber value="UA-767PBT-C"/> 
  <type> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="65573"/> 
      <display value="MDC_MOC_VMS_MDS_SIMP"/> 
    </coding> 
    <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> 
  </type> 
  <version> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="532352"/> 
      </coding> 
      <text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/> 
    </type> 
    <value value="1.0"/> 
  </version> 
  <conformsTo> 
    <specification> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="528391"/> 
      </coding> 
      <text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"/> 
    </specification> 
    <version value="1"/> 
  </conformsTo> 
  <property> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="532353"/> 
      </coding> 
      <text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaPAN"/> 
        <code value="7"/> 
      </coding> 
    </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> 
        <code value="532354.0"/> 
        <display value="regulation-status"/> 
      </coding> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> 
        <code value="N"/> 
      </coding> 
      <text value="Device is Regulated"/> 
    </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="68220"/> 
      </coding> 
      <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="532224"/> 
      </coding> 
      <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> 
    </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> 
        <code value="68219.0"/> 
      </coding> 
      <text value="mds-time-capab-real-time-clock"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> 
        <code value="Y"/> 
      </coding> 
      <text value="real time clock supported"/> 
    </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> 
        <code value="68219.1"/> 
      </coding> 
      <text value="mds-time-capab-set-clock"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> 
        <code value="Y"/> 
      </coding> 
      <text value="setting the time supported"/> 
    </valueCodeableConcept> 
  </property> 
  <property> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> 
        <code value="68219.11"/> 
      </coding> 
      <text value="mds-time-mgr-set-time"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> 
        <code value="Y"/> 
      </coding> 
      <text value="manager requested to set the time"/> 
    </valueCodeableConcept> 
  </property> 
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.