This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions 
http://hl7.org/fhir/SearchParameter/DeviceRequest-authored-on |
12.24.14 authored-on Parameter authored-on:date
When the request transitioned to being actionable
| Resource | DeviceRequest |
| Expression |
DeviceRequest.authoredOn |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
| Comparators |
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap |
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-based-on |
12.24.15 based-on Parameter based-on:reference
Plan/proposal/order fulfilled by this request
| Resource | DeviceRequest |
| Expression |
DeviceRequest.basedOn |
| Processing Mode |
Normal |
| Target Resources |
All Resources |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-device |
12.24.16 device Parameter device:reference
Reference to resource that is being requested/ordered
| Resource | DeviceRequest |
| Expression |
DeviceRequest.product.reference |
| Processing Mode |
Normal |
| Target Resources |
Device, DeviceDefinition |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/clinical-encounter |
| This search parameter is part of the common search parameter clinical-encounter |
12.24.17 encounter Parameter encounter:reference
| Resource | DeviceRequest |
| Expression |
DeviceRequest.encounter |
| Processing Mode |
Normal |
| Target Resources |
Encounter |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-event-date |
12.24.18 event-date Parameter event-date:date
When service should occur
| Resource | DeviceRequest |
| Expression |
(DeviceRequest.occurrence.ofType(dateTime)) | (DeviceRequest.occurrence.ofType(Period)) |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
| Comparators |
Allowed: eq, ne, gt, ge, lt, le, sa, eb, ap |
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-group-identifier |
12.24.19 group-identifier Parameter group-identifier:token
Composite request this is part of
| Resource | DeviceRequest |
| Expression |
DeviceRequest.groupIdentifier |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/clinical-identifier |
| This search parameter is part of the common search parameter clinical-identifier |
12.24.20 identifier Parameter identifier:token
| Resource | DeviceRequest |
| Expression |
DeviceRequest.identifier |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-insurance |
12.24.21 insurance Parameter insurance:reference
Associated insurance coverage
| Resource | DeviceRequest |
| Expression |
DeviceRequest.insurance |
| Processing Mode |
Normal |
| Target Resources |
ClaimResponse, Coverage |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-intent |
12.24.22 intent Parameter intent:token
proposal | plan | original-order |reflex-order
| Resource | DeviceRequest |
| Expression |
DeviceRequest.intent |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-location-code |
12.24.23 location-code Parameter location-code:token
The preferred location specified in the DeviceRequest (coded)
| Resource | DeviceRequest |
| Expression |
DeviceRequest.location.concept |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/clinical-patient |
| This search parameter is part of the common search parameter clinical-patient |
12.24.24 patient Parameter patient:reference
| Resource | DeviceRequest |
| Expression |
DeviceRequest.subject.where(resolve() is Patient) |
| Processing Mode |
Normal |
| Target Resources |
Patient |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-performer |
12.24.25 performer Parameter performer:reference
Desired performer for service
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-performer-code |
12.24.26 performer-code Parameter performer-code:token
Desired performer for service
| Resource | DeviceRequest |
| Expression |
DeviceRequest.performer.concept |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-prior-request |
12.24.27 prior-request Parameter prior-request:reference
Request takes the place of referenced completed or terminated requests
| Resource | DeviceRequest |
| Expression |
DeviceRequest.replaces |
| Processing Mode |
Normal |
| Target Resources |
DeviceRequest |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-product |
12.24.28 product Parameter product:token
Code for what is being requested/ordered
| Resource | DeviceRequest |
| Expression |
DeviceRequest.product.concept |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-requester |
12.24.29 requester Parameter requester:reference
Who/what is requesting service
| Resource | DeviceRequest |
| Expression |
DeviceRequest.requester |
| Processing Mode |
Normal |
| Target Resources |
Device, Organization, CareTeam, PractitionerRole, Practitioner, Group |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-status |
12.24.30 status Parameter status:token
entered-in-error | draft | active |suspended | completed
| Resource | DeviceRequest |
| Expression |
DeviceRequest.status |
| Processing Mode |
Normal |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |
http://hl7.org/fhir/SearchParameter/DeviceRequest-subject |
12.24.31 subject Parameter subject:reference
Individual the service is ordered for
| Resource | DeviceRequest |
| Expression |
DeviceRequest.subject |
| Processing Mode |
Normal |
| Target Resources |
Device, Group, Location, Patient |
| Multiples |
- multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
- multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true
|
|
| |