4.3.2.179 CodeSystem http://hl7.org/fhir/deviceassociation-relationship

Responsible Owner: Orders and Observations icon Work Group Normative Use Context: Country: World, Not Intended for Production use
Official URL: http://hl7.org/fhir/deviceassociation-relationship Version: 6.0.0-ballot4
active as of 2026-06-11 Computable Name: DeviceAssociationRelationshipCodes
Flags: Experimental, CaseSensitive, Complete OID: TBD

This Code system is used in the following FHIR core-defined or referenced value sets:


Example codes that describe the relationship between the device and the subject.

Generated Narrative: CodeSystem deviceassociation-relationship

Last updated: 2026-06-11T22:32:02.825Z

This case-sensitive code system http://hl7.org/fhir/deviceassociation-relationship defines the following codes in an undefined hierarchy:

LvlCodeDisplayDefinitionCopy
1 patient-person Patient/person Associations involving a patient, related person, practitioner, or other person-like subject. btn btn
2   used-by Used By The device is used by the subject. btn btn
2   assigned-to Assigned To The device is assigned to the subject. btn btn
2   leased-by Leased By The device is leased by the subject. btn btn
2   worn-by Worn By The device is worn by the subject. btn btn
2   carried-by Carried By The device is carried by the subject. btn btn
2   monitored-by Monitored By The device is associated with the subject for monitoring. btn btn
1 implantation-attachment Implantation/attachment Associations involving implantation in, or attachment to, the subject. btn btn
2   implanted-in Implanted In The device is implanted in the subject. btn btn
2   attached-to Attached To The device is attached to the subject. btn btn
1 location Location Associations involving a location where the device is installed, located, or stored. btn btn
2   installed-at Installed At The device is installed at the subject location. btn btn
2   located-at Located At The device is located at the subject location. btn btn
2   stored-at Stored At The device is stored at the subject location. btn btn
1 device-to-device Device-to-device Associations between the device and another device. btn btn
2   connected-to Connected To The device is connected to the subject device. btn btn
2   controls Controls The device controls the subject device. btn btn
2   programs Programs The device programs the subject device. btn btn
2   calibrates Calibrates The device calibrates the subject device. btn btn
2   maintains Maintains The device maintains the subject device. btn btn
2   powers Powers The device powers the subject device. btn btn
2   communicates-with Communicates With The device communicates with the subject device. btn btn
1 organizational Organizational Associations involving organizational responsibility or custody. btn btn
2   managed-by Managed By The device is managed by the subject. btn btn
2   in-custody-of In Custody Of The device is in the custody of the subject. btn btn
2   maintained-by Maintained By The device is maintained by the subject. btn btn

 

See the full registry of code systems defined as part of FHIR.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. See Code System for further information.
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept