FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions icon

4.4.1.145 ValueSet http://hl7.org/fhir/ValueSet/devicealert-condition

Responsible Owner: Health Care Devices icon Work Group Normative Use Context: Country: World
Official URL: http://hl7.org/fhir/ValueSet/devicealert-condition Version: 6.0.0-ballot4
active as of 2026-03-18 Computable Name: DeviceAlertConditionCodes
Flags: OID:

This value set is used in the following places:

DeviceAlert Condition Codes


Generated Narrative: ValueSet devicealert-condition

Last updated: 2026-03-18T20:20:28.343Z

 

This expansion generated 18 Mar 2026


ValueSet

Expansion from tx.fhir.org based on codesystem MDC Nomenclature v2024-12-05 (CodeSystem) icon

This value set has >1000 codes in it. In order to keep the publication size manageable, only a selection (1000 codes) of the whole set of codes is shown

SystemCodeDisplayDefinition
urn:iso:std:iso:11073:10101   196608 icon MDC_EVT
  1. An event has occurred (NOS)
  2. Event (NOS).
urn:iso:std:iso:11073:10101   196610 icon MDC_EVT_ABNORM
  1. Abnormal condition detected (NOS)
  2. Abnormal condition detected.
urn:iso:std:iso:11073:10101   196612 icon MDC_EVT_ABSENT
  1. Absent
  2. Absent.
urn:iso:std:iso:11073:10101   196614 icon MDC_EVT_ACTIVE

Active (NOS)

urn:iso:std:iso:11073:10101   196616 icon MDC_EVT_ALARM
  1. Alarm (NOS)
  2. Alarm (NOS).
urn:iso:std:iso:11073:10101   196620 icon MDC_EVT_CONN

Connection

urn:iso:std:iso:11073:10101   196622 icon MDC_EVT_CONTAM

Contaminated

urn:iso:std:iso:11073:10101   196624 icon MDC_EVT_DEFECT

Defect is detected in a device, sensor, etc.

urn:iso:std:iso:11073:10101   196626 icon MDC_EVT_DEPLET

An agent is detected as depleted in a device, sensor, etc

urn:iso:std:iso:11073:10101   196628 icon MDC_EVT_DETEC

Some signal or special condition was detected.

urn:iso:std:iso:11073:10101   196630 icon MDC_EVT_DISCONN
  1. Disconnection, e.g., in sampling line
  2. Disconnection, e.g., in sampling line.
urn:iso:std:iso:11073:10101   196632 icon MDC_EVT_DISTURB
  1. Signal is disturbed.
  2. {Airway gas concentration} signal is disturbed.
urn:iso:std:iso:11073:10101   196634 icon MDC_EVT_EMPTY

A reservoir, etc., is empty.

urn:iso:std:iso:11073:10101   196636 icon MDC_EVT_EQU
  1. Unspecified device error
  2. Unspecified device error.
urn:iso:std:iso:11073:10101   196638 icon MDC_EVT_ERR
  1. Error condition is detected
  2. Problem in power supply module.
urn:iso:std:iso:11073:10101   196640 icon MDC_EVT_ERRATIC

Erratic condition is detected.

urn:iso:std:iso:11073:10101   196642 icon MDC_EVT_EXCESS
  1. A reservoir, etc., has excess content
  2. Excess(ive) [NOS].
urn:iso:std:iso:11073:10101   196644 icon MDC_EVT_EXH
  1. A consumable is exhausted
  2. Exhausted.
urn:iso:std:iso:11073:10101   196646 icon MDC_EVT_FAIL

An action, data transmission, etc., failed.

urn:iso:std:iso:11073:10101   196648 icon MDC_EVT_HI

{numeric observation} > high limit

urn:iso:std:iso:11073:10101   196650 icon MDC_EVT_HI_GT_LIM

A metric exceeds a given threshold

urn:iso:std:iso:11073:10101   196652 icon MDC_EVT_HI_VAL_GT_LIM

A metric exceeds a given threshold.

urn:iso:std:iso:11073:10101   196654 icon MDC_EVT_INCORRECT
  1. Incorrect result of a calculation, e.g., CRC in data transmission, of a data structure, etc., detected
  2. Incorrect result of a calculation, e.g., CRC in data transmission, of a data structure, etc., detected.
urn:iso:std:iso:11073:10101   196656 icon MDC_EVT_INFILT
  1. Infiltration NOS
  2. Infiltration [NOS].
urn:iso:std:iso:11073:10101   196658 icon MDC_EVT_INGRESS
  1. Ingress of contaminant NOS
  2. Ingress [NOS].
urn:iso:std:iso:11073:10101   196660 icon MDC_EVT_INOP
  1. (Un)intentional inoperable condition NOS
  2. (Un)intentional inoperable condition.
urn:iso:std:iso:11073:10101   196662 icon MDC_EVT_INTERF
  1. Interference NOS
  2. Interference [NOS].
urn:iso:std:iso:11073:10101   196664 icon MDC_EVT_INTERRUP

A measurement, process, or data transmission was interrupted.

urn:iso:std:iso:11073:10101   196666 icon MDC_EVT_IRREG

Irregular rhythm or waveform in a signal, etc.

urn:iso:std:iso:11073:10101   196668 icon MDC_EVT_LEAK
  1. Leakage in a gas or fluid filled system detected
  2. Leakage in a gas or fluid filled system detected.
urn:iso:std:iso:11073:10101   196670 icon MDC_EVT_LO

{numeric observation} < low limit

urn:iso:std:iso:11073:10101   196672 icon MDC_EVT_LO_LT_LIM

A metric falls short of a given threshold

urn:iso:std:iso:11073:10101   196674 icon MDC_EVT_LO_VAL_LT_LIM

A metric falls short of a given threshold.

urn:iso:std:iso:11073:10101   196676 icon MDC_EVT_LOST

Signal or synchronization, etc., was lost.

urn:iso:std:iso:11073:10101   196678 icon MDC_EVT_MALF
  1. Malfunction of a device, VMD, or sensor is detected.
  2. {NMT} hardware malfunction; unplugging or restarting the {NMT} measurement module may correct the problem.
urn:iso:std:iso:11073:10101   196680 icon MDC_EVT_MODE
  1. Mode status
  2. Mode status (notification)
urn:iso:std:iso:11073:10101   196682 icon MDC_EVT_NOISY

Signal is noisy.

urn:iso:std:iso:11073:10101   196686 icon MDC_EVT_NOT_DEFLATED
  1. Cuff not fully deflated
  2. {NBP Cuff} Deflation error
urn:iso:std:iso:11073:10101   196688 icon MDC_EVT_OBSTRUC

Flow is hindered.

urn:iso:std:iso:11073:10101   196696 icon MDC_EVT_OVER

Overflow was detected in a measurement or calculation

urn:iso:std:iso:11073:10101   196698 icon MDC_EVT_OVERFLOW

Overflow was detected in a measurement or calculation.

urn:iso:std:iso:11073:10101   196700 icon MDC_EVT_PROB
  1. Unspecified device error
  2. Problem (NOS).
urn:iso:std:iso:11073:10101   196704 icon MDC_EVT_REVERSED

Flow is reversed

urn:iso:std:iso:11073:10101   196708 icon MDC_EVT_SHORT
  1. Error Event: Sensor electrical lead (e.g., ECG) is shorted (NOS)
  2. Short (electrical) [NOS].
urn:iso:std:iso:11073:10101   196710 icon MDC_EVT_STAT_DISP_STOP

The display is stopped.

urn:iso:std:iso:11073:10101   196712 icon MDC_EVT_SUBATMOS
  1. Subatmospheric [NOS]
  2. Subatmospheric [NOS].
urn:iso:std:iso:11073:10101   196714 icon MDC_EVT_SUST
  1. Unspecified device error sustained
  2. Sustained [NOS].
urn:iso:std:iso:11073:10101   196716 icon MDC_EVT_UNANALYZEABLE
  1. Unanalyzable processing error message
  2. Unanalyzable signal or measurement; cannot be processed.
urn:iso:std:iso:11073:10101   196718 icon MDC_EVT_UNAVAIL

Resource is unavailable.

urn:iso:std:iso:11073:10101   196720 icon MDC_EVT_UNDEF

Undefined.

urn:iso:std:iso:11073:10101   196722 icon MDC_EVT_UNDER

Underflow was detected in a measurement or calculation

urn:iso:std:iso:11073:10101   196724 icon MDC_EVT_UNEQU
  1. Unequal
  2. Unequal.
urn:iso:std:iso:11073:10101   196726 icon MDC_EVT_UNK

VMD or signal is unknown.

urn:iso:std:iso:11073:10101   196728 icon MDC_EVT_UNPLUGGED
  1. A component (sensor, module) has become unplugged
  2. A component (sensor, module or device) has become unplugged
urn:iso:std:iso:11073:10101   196730 icon MDC_EVT_VIOL
  1. Device has violated an operating parameter
  2. Violation (NOS).
urn:iso:std:iso:11073:10101   196732 icon MDC_EVT_WARMING
  1. Indication: Device warming in Progress, No Measurement Possible
  2. Warming [NOS].
urn:iso:std:iso:11073:10101   196734 icon MDC_EVT_WARN
  1. Unspecified device error warning
  2. Warning (NOS).
urn:iso:std:iso:11073:10101   196736 icon MDC_EVT_WEAK

Weak signal was detected.

urn:iso:std:iso:11073:10101   196738 icon MDC_EVT_RECOV_ERR
  1. Recoverable state machine error in communication
  2. Recoverable state machine error in communication.
urn:iso:std:iso:11073:10101   196740 icon MDC_EVT_UNINTEN_INOP
  1. Device has become inoperable
  2. Unintentional inop.
urn:iso:std:iso:11073:10101   196742 icon MDC_EVT_UNRECOV_ERR
  1. Unrecoverable state machine error in communication
  2. Unrecoverable state machine error in communication.
urn:iso:std:iso:11073:10101   196744 icon MDC_EVT_BREATH_ABSENT
  1. Error Event: Breath Absent (this is not apnea, but a technical ventilator event.)
  2. Error Event: breath absent (this is not apnea, but a technical ventilator event.).
urn:iso:std:iso:11073:10101   196746 icon MDC_EVT_CALIB_FAIL
  1. Calibration is not successful.
  2. {SpO2} Only Mode (not fully calibrated)
urn:iso:std:iso:11073:10101   196748 icon MDC_EVT_COMM_LOST
  1. Error Event: Communication Lost
  2. {Monitor} No communications
urn:iso:std:iso:11073:10101   196750 icon MDC_EVT_CONFIG_ERR
  1. Device configuration: combination is not valid.
  2. {SpO2} Connection not supported
urn:iso:std:iso:11073:10101   196752 icon MDC_EVT_DATA_ACQN_PROB

Unspecified problem in data acquisition

urn:iso:std:iso:11073:10101   196754 icon MDC_EVT_FUNC_UNAVAIL

A resource is not available.

urn:iso:std:iso:11073:10101   196756 icon MDC_EVT_GAIN_HI
  1. Signal gain high: probably erroneous data extraction
  2. Gain high.
urn:iso:std:iso:11073:10101   196758 icon MDC_EVT_GAIN_LO
  1. Signal gain low: probably erroneous data extraction
  2. Gain low.
urn:iso:std:iso:11073:10101   196760 icon MDC_EVT_HANDL_ERR
  1. Not specified, unnormal handling of a device, device component, cabling, or transducer
  2. Not specified, unnormal handling of a device, device component, cabling, or transducer.
urn:iso:std:iso:11073:10101   196762 icon MDC_EVT_INFLAT_OVER
  1. Over inflated (non-specific)
  2. Over-inflated.
urn:iso:std:iso:11073:10101   196764 icon MDC_EVT_MIX_ERR
  1. Mix errror
  2. Gas (or other) mixer inoperable.
urn:iso:std:iso:11073:10101   196766 icon MDC_EVT_POSN_IRREG
  1. Irregular position of a plug-in device
  2. Problem in position of a plug-in device
  3. Position irregular.
  4. Irregular position of a plug-in device.
urn:iso:std:iso:11073:10101   196768 icon MDC_EVT_POSN_PROB
  1. Irregular position of a plug-in device
  2. Problem in position of a plug-in device
  3. Position irregular.
  4. Irregular position of a plug-in device.
urn:iso:std:iso:11073:10101   196770 icon MDC_EVT_PROC_ERR
  1. Unspecified processing error
  2. Unspecified processing error.
urn:iso:std:iso:11073:10101   196772 icon MDC_EVT_RANGE_ERR
  1. Signal amplitude is incorrect for processing
  2. Signal out of range
urn:iso:std:iso:11073:10101   196774 icon MDC_EVT_RANGE_OVER
  1. Signal amplitude is too high for processing.
  2. {Impedance respiration rate} Out of range (high)
urn:iso:std:iso:11073:10101   196776 icon MDC_EVT_RANGE_UNDER
  1. Signal amplitude is too low for processing, e.g., waveform detection.
  2. {ST} Out of range (low)
urn:iso:std:iso:11073:10101   196778 icon MDC_EVT_SHAPE_ERR

[Pattern] Shape error.

urn:iso:std:iso:11073:10101   196780 icon MDC_EVT_SIG_ERRATIC

Error Event: Signal erratic

urn:iso:std:iso:11073:10101   196782 icon MDC_EVT_SRC_ABSENT
  1. Error Event: Signal source absent
  2. Source absent or missing.
urn:iso:std:iso:11073:10101   196784 icon MDC_EVT_SUPPLY_LO
  1. Low voltage detected power supply
  2. Unspecified tools or agents (e.g. calibration fluids) are low.
urn:iso:std:iso:11073:10101   196786 icon MDC_EVT_SUPPLY_PROB
  1. Problem in power supply
  2. Supplies problem.
urn:iso:std:iso:11073:10101   196788 icon MDC_EVT_SVC_QUALITY
  1. Unspecified quality of service event
  2. Unspecified quality of service event.
urn:iso:std:iso:11073:10101   196790 icon MDC_EVT_SYNCH_ERR
  1. Error in time synchronization
  2. Error in time synchronization.
urn:iso:std:iso:11073:10101   196792 icon MDC_EVT_SYNCH_INOP

Synchronisation inoperable

urn:iso:std:iso:11073:10101   196794 icon MDC_EVT_TIMEOUT_ERR
  1. Communication error: timeout
  2. Timeout error.
urn:iso:std:iso:11073:10101   196796 icon MDC_EVT_VIB_PROB

Vibration hinders adequate measurement.

urn:iso:std:iso:11073:10101   196798 icon MDC_EVT_WEDGE_OCCL
  1. Pulmonary Capillary Wedge Pressure: occluded
  2. Occluded [Wedged].
urn:iso:std:iso:11073:10101   196800 icon MDC_EVT_BATT_FAIL
  1. Battery failed or is defective
  2. {*} Battery inoperable
urn:iso:std:iso:11073:10101   196802 icon MDC_EVT_BATT_LO
  1. Battery discharged or is defective.
  2. {ecgResp} Battery low
  3. {device or sensor} Battery low
urn:iso:std:iso:11073:10101   196804 icon MDC_EVT_BATT_MALF

Battery malfunction

urn:iso:std:iso:11073:10101   196806 icon MDC_EVT_BATT_PROB

Unspecified battery problem

urn:iso:std:iso:11073:10101   196808 icon MDC_EVT_VENT_OCCL
  1. Breathing system occlusion
  2. Ventilator breathing system occlusion.
urn:iso:std:iso:11073:10101   196810 icon MDC_EVT_BUFF_OVERFLO

Use MDC_EVT_BUFF_OVERFLOW (3::502)

urn:iso:std:iso:11073:10101   196812 icon MDC_EVT_CABLE_SHORT
  1. Communication error: cable short
  2. {SpO2} Cable failure
urn:iso:std:iso:11073:10101   196814 icon MDC_EVT_CATH_PULM_INFLAT_OVER
  1. Pulmonary Capillary Wedge Pressure: over inflation
  2. {Pulmonary artery catheter} catheter cuff over-inflated.
urn:iso:std:iso:11073:10101   196816 icon MDC_EVT_CKT_SHORT

A short circuit was detected in a VMD.

urn:iso:std:iso:11073:10101   196818 icon MDC_EVT_VENT_EXH
  1. Exhausted CO2 absorber
  2. Ventilator - exhausted CO2 absorber.
urn:iso:std:iso:11073:10101   196820 icon MDC_EVT_CO2_CAN_LEAK
  1. CO2 Canister leak
  2. CO2 canister leak.
urn:iso:std:iso:11073:10101   196822 icon MDC_EVT_CO2_SAMPL_LINE_DEFECT

Defect occurred in a CO2 sample line

urn:iso:std:iso:11073:10101   196824 icon MDC_EVT_CO2_WIND_OBSTRUC
  1. Carbon dioxide measurement window in a CO2 measuring device is occluded.
  2. The airway CO2 sensor window is occluded.
urn:iso:std:iso:11073:10101   196826 icon MDC_EVT_COMM_LINK_NOISY
  1. Error Event: Communication Link Noisy
  2. Comm link noisy.
urn:iso:std:iso:11073:10101   196828 icon MDC_EVT_COMM_MODULE_ERR
  1. Error Event: Communication Module Error
  2. Communication module error.
urn:iso:std:iso:11073:10101   196830 icon MDC_EVT_COMPONENT_POSN_PROB
  1. Supply or disposable positioning problem
  2. Supply or disposable positioning problem.
urn:iso:std:iso:11073:10101   196832 icon MDC_EVT_CONNECTOR_SHORT
  1. Connection short
  2. Connector short.
urn:iso:std:iso:11073:10101   196834 icon MDC_EVT_CUFF_INCORRECT
  1. Incorrect Cuff
  2. Incorrect NIBP cuff type
urn:iso:std:iso:11073:10101   196836 icon MDC_EVT_CUFF_LEAK

Cuff leak

urn:iso:std:iso:11073:10101   196838 icon MDC_EVT_CUFF_NOT_DEFLATED
  1. Cuff not fully deflated
  2. {NBP} cuff not deflated.
urn:iso:std:iso:11073:10101   196840 icon MDC_EVT_CUFF_INFLAT_OVER
  1. Cuff over inflated
  2. {NBP} cuff over-inflated, i.e. cuff pressure high.
urn:iso:std:iso:11073:10101   196842 icon MDC_EVT_DOOR_OR_HANDLE_POSN_PROB

A door or handle which must be closed for proper operation is open.

urn:iso:std:iso:11073:10101   196844 icon MDC_EVT_ELEC_PWR_LINE_PROB
  1. Electric power line: unspecified problem
  2. Electric power line: unspecified problem.
urn:iso:std:iso:11073:10101   196846 icon MDC_EVT_ENDOTRACH_TUBE_LEAK
  1. Endotracheal tube leak (ventilator)
  2. Endotracheal tube leak (ventilator).
urn:iso:std:iso:11073:10101   196850 icon MDC_EVT_EQUIP_MALF
  1. Unspecified device malfunction error warning
  2. {ECG} equipment malfunction.
urn:iso:std:iso:11073:10101   196852 icon MDC_EVT_FLUID_LINE_DISTURB
  1. Flow disturbance
  2. Pump flow disturbance.
urn:iso:std:iso:11073:10101   196854 icon MDC_EVT_FLUID_LINE_INFILT
  1. Infiltration of fluid line
  2. Infiltration of fluid line.
urn:iso:std:iso:11073:10101   196856 icon MDC_EVT_FLUID_LINE_INGRESS
  1. Ingress in fluid line
  2. Fluid line ingress.
urn:iso:std:iso:11073:10101   196858 icon MDC_EVT_TUBE_OCCL
  1. Flow in tube is occluded
  2. Tube occluded.
urn:iso:std:iso:11073:10101   196860 icon MDC_EVT_FLUID_LINE_PROB
  1. Problem in fluid line
  2. Problem in fluid line.
urn:iso:std:iso:11073:10101   196862 icon MDC_EVT_FLUID_LINE_FLOW_SENSOR_PROB
  1. Flow sensor problem
  2. Flow sensor problem.
urn:iso:std:iso:11073:10101   196864 icon MDC_EVT_GAS_CONTAM

Gas contamination

urn:iso:std:iso:11073:10101   196866 icon MDC_EVT_GAS_AGENT_IDENT_MALF
  1. Gas agent identification malfunction
  2. Gas agent identification malfunction.
urn:iso:std:iso:11073:10101   196868 icon MDC_EVT_GAS_LINE_PROB
  1. Gas line problem
  2. Gas line problem (with the breathing system).
urn:iso:std:iso:11073:10101   196870 icon MDC_EVT_HEATING_PWR_PROB
  1. Heater power problem
  2. Heating Power problem.
urn:iso:std:iso:11073:10101   196872 icon MDC_EVT_HOSE_LEAK
  1. Leak in hose within breathing system
  2. Leak in breathing system.
urn:iso:std:iso:11073:10101   196874 icon MDC_EVT_HOSE_OBSTRUC
  1. Flow in hose is obstructed
  2. (Ventilator) hose obstructed.
urn:iso:std:iso:11073:10101   196876 icon MDC_EVT_LEAD_DISCONN
  1. Error Event: (ECG) Lead Disconnected (specialized form of the generic disconnect event. In case of ECG, some ECG devices reconstruct leads when a single lead of a multilead cable falls off. This needs a special user notification, because the situation might not be visible on the display waves. Reasoning: see above.)
  2. Error Event: {ECG} Lead Disconnected (specialized form of the generic disconnect event). [In the case of ECG, some ECG devices reconstruct leads when a single lead of a multilead cable falls off. This needs a special user notification, because the situation might not be visible on the display waves. Reasoning: see above.]
urn:iso:std:iso:11073:10101   196878 icon MDC_EVT_LEAD_NOISY
  1. Error Event: (ECG) Lead Noisy
  2. {ECG} lead data is invalid due to excessive signal noise, bad electrode contact, interference from external devices and/or incorrect {ST} lead selection(s).
urn:iso:std:iso:11073:10101   196880 icon MDC_EVT_LEAD_OFF
  1. Error Event: (ECG) Lead Disconnected
  2. {ECG} Lead off
urn:iso:std:iso:11073:10101   196882 icon MDC_EVT_LEADS_OFF
  1. Error Event: (ECG) Leads Disconnected
  2. One or more {ECG} leads are not attached to the patient.
urn:iso:std:iso:11073:10101   196884 icon MDC_EVT_LIGHTS_IN_ROOM_OFF
  1. Lights in the (sleep measurement) room are switched off.
  2. Lights in the {sleep measurement} room are switched off.
urn:iso:std:iso:11073:10101   196886 icon MDC_EVT_LIGHT_INTERF
  1. Error Event: Light Interference (SpO2 measurement, special kind of interference)
  2. {SpO2} Regulation error: an excessive amount of ambient light is present, giving low amplitude and inaccurate readings as a result.
urn:iso:std:iso:11073:10101   196888 icon MDC_EVT_LIGHT_SRC_ABSENT
  1. Error Event: Light source absent
  2. Light source absent or missing.
urn:iso:std:iso:11073:10101   196890 icon MDC_EVT_MED_GAS_SUPPLY_LO
  1. Medical gas or supply low
  2. Medical gas or supply low.
urn:iso:std:iso:11073:10101   196892 icon MDC_EVT_MODULE_DISCONN
  1. Module disconnnected
  2. Module disconnected
urn:iso:std:iso:11073:10101   196894 icon MDC_EVT_MODULE_EXCESS
  1. Too many [plugin] modules
  2. Too many modules.
urn:iso:std:iso:11073:10101   196896 icon MDC_EVT_MODULE_UNK
  1. [Plugin] Module unknown
  2. [Plugin] Module unknown.
urn:iso:std:iso:11073:10101   196898 icon MDC_EVT_MS_SUBSYS_DISCONN
  1. Subsystem disconnected
  2. {Measurement module} subsystem disconnected.
urn:iso:std:iso:11073:10101   196900 icon MDC_EVT_MSG_COMM_ERR
  1. Error Event: Communication Message Error
  2. Subsystem has received false data packet.
urn:iso:std:iso:11073:10101   196904 icon MDC_EVT_O2_SUPPLY_LO
  1. Too low O2 delivery (concentration or flow)
  2. Too low O2 delivery (concentration or flow).
urn:iso:std:iso:11073:10101   196906 icon MDC_EVT_OPTIC_MODULE_ABSENT
  1. Optical Module Absent
  2. Optical module absent or missing.
urn:iso:std:iso:11073:10101   196908 icon MDC_EVT_OPTIC_MODULE_DEFECT
  1. Optical Module Defect
  2. Optical module defect.
urn:iso:std:iso:11073:10101   196910 icon MDC_EVT_PAPER_PROB
  1. Problem with recording paper
  2. [Hardcopy] paper problem.
urn:iso:std:iso:11073:10101   196912 icon MDC_EVT_PLUGIN_INCORRECT
  1. Incorrect plugin [module]
  2. Incorrect plugin [module].
urn:iso:std:iso:11073:10101   196914 icon MDC_EVT_PLUGIN_POSN_IRREG

Problem in position of a plug-in device

urn:iso:std:iso:11073:10101   196916 icon MDC_EVT_SENSOR_DISCONN
  1. Sensor disconnection or fault
  2. {SpO2} sensor disconnection or fault.
urn:iso:std:iso:11073:10101   196918 icon MDC_EVT_SENSOR_MALF
  1. Sensor malfunction
  2. {SpO2} sensor malfunction.
  3. {SpO2} sensor malfunction, a current state or condition of faulty or improper functioning.
urn:iso:std:iso:11073:10101   196920 icon MDC_EVT_SENSOR_PROB
  1. Flow sensor problem
  2. {SpO2} sensor problem.
urn:iso:std:iso:11073:10101   196922 icon MDC_EVT_SIDESTRM_MALF
  1. [CO2] Sidestream malfunction
  2. {Airway CO2} sidestream malfunction.
urn:iso:std:iso:11073:10101   196924 icon MDC_EVT_SIDESTRM_OFF
  1. [CO2] Sidestream off
  2. {Airway CO2} sidestream off.
urn:iso:std:iso:11073:10101   196926 icon MDC_EVT_SIDESTRM_ON
  1. [CO2] Sidestream on
  2. {Airway CO2} sidestream on.
urn:iso:std:iso:11073:10101   196928 icon MDC_EVT_SITE_TIMER_PROB
  1. Site timer problem
  2. Site Timer Problem.
urn:iso:std:iso:11073:10101   196930 icon MDC_EVT_SW_VER_UNK
  1. Communication error: unknown software version
  2. Communication error: unknown software version.
urn:iso:std:iso:11073:10101   196934 icon MDC_EVT_TUBE_DISCONN
  1. Tube disconnected, e.g., disconnection in fresh gas flow hose
  2. Tube disconnected, e.g. disconnection in fresh gas flow hose.
urn:iso:std:iso:11073:10101   196936 icon MDC_EVT_TUBE_LEAK
  1. Leak in tube
  2. Tube leak.
urn:iso:std:iso:11073:10101   196938 icon MDC_EVT_TUBE_OBSTRUC
  1. Flow in tube is obstructed
  2. Tube obstructed.
urn:iso:std:iso:11073:10101   196940 icon MDC_EVT_FLUID_LINE_OCCL

Occlusion of fluid line.

urn:iso:std:iso:11073:10101   196942 icon MDC_EVT_XDUCR_ABSENT
  1. Transducer absent
  2. {Temperature} transducer absent or missing.
urn:iso:std:iso:11073:10101   196944 icon MDC_EVT_XDUCR_DISCONN
  1. Error Event: Transducer Disconnected (specialized form of the generic disconnect event for measurements with intelligent transducer)
  2. Error Event: {SpO2} transducer disconnected (specialized form of the generic disconnect event for measurements with intelligent transducer.
urn:iso:std:iso:11073:10101   196946 icon MDC_EVT_XDUCR_MALF
  1. Transducer malfunctioning
  2. {Predictive-temperature} transducer malfunctioning.
urn:iso:std:iso:11073:10101   196948 icon MDC_EVT_BW_INCORRECT
  1. Bandwidth incorrect
  2. Bandwidth incorrect.
urn:iso:std:iso:11073:10101   196950 icon MDC_EVT_FLOW_LO
  1. Flow is low
  2. {Pump} flow low.
urn:iso:std:iso:11073:10101   196952 icon MDC_EVT_FLOW_REVERSED
  1. Flow is reversed
  2. {Ventilator} reverse flow (not specific to inspiratory or expiratory limb).
urn:iso:std:iso:11073:10101   196954 icon MDC_EVT_FLUID_LINE_DRIP_MALF
  1. Error in drip counting measurement
  2. Error in drip counting measurement.
urn:iso:std:iso:11073:10101   196956 icon MDC_EVT_INTENS_ERR
  1. Error Event: Radiation source intensity incorrect
  2. Intensity error (NOS).
urn:iso:std:iso:11073:10101   196958 icon MDC_EVT_INTENS_LIGHT_ERR
  1. Error Event: Light source intensity incorrect
  2. Light Intensity error.
urn:iso:std:iso:11073:10101   196960 icon MDC_EVT_MSMT_DISCONN
  1. Error Event: Measurement Unplugged (e.g., in modular patient monitor. Reasoning: In contrast to the disconnect events below, this event indicates that a measurement module was manually (==voluntarily) removed. Dependent on the alarm configuration of a monitor (specifically, with latched alarms), this condition must be announced to the user; and the user must specifically acknowledge the situation.)
  2. Error Event: {*} measurement unplugged (e.g., in modular patient monitor. Reasoning: In contrast to the disconnect events below, this event indicates that a measurement module was manually (==voluntarily) removed. Dependent on the alarm configuration of a monitor (specifically, with latched alarms), this condition must be announced to the user; and the user must specifically acknowledge the situation.). [The optional attribute MDC_ATTR_EVT_INTENTIONALITY may be included in the alert message to indicate degree of intentionality by the user.]
urn:iso:std:iso:11073:10101   196962 icon MDC_EVT_MSMT_ERR
  1. Unspecified error in processing of a biosignal
  2. Unspecified error in processing of {temperature} biosignal.
urn:iso:std:iso:11073:10101   196964 icon MDC_EVT_MSMT_FAIL
  1. Error Event: Measurement Failed (e.g., a noninvasive blood pressure)
  2. Error Event: {NBP} measurement failed (e.g., a noninvasive blood pressure).
urn:iso:std:iso:11073:10101   196966 icon MDC_EVT_MSMT_INOP
  1. Error Event: Measurement inoperable, Failed (e.g., a noninvasive blood pressure)
  2. {SpO2} No measurement
urn:iso:std:iso:11073:10101   196968 icon MDC_EVT_MSMT_INTERF
  1. Error Event: Measurement intereference (e.g., a noninvasive blood pressure)
  2. Interference in measurement
urn:iso:std:iso:11073:10101   196970 icon MDC_EVT_MSMT_INTERRUP

Error Event: Measurement Interrupted (e.g., a noninvasive blood pressure) (there is a generic interrupted code for processing; however, this code does not have to do with processing. As an example of this code, the user might simply hit a stop button, and this action makes the measurement invalid.)

urn:iso:std:iso:11073:10101   196972 icon MDC_EVT_MSMT_RANGE_OVER
  1. Error Event: Measurement Range Exceeded, i.e., the signal is out of the physiological range that is specified in the Metric object.
  2. Error Event: Metric (measurement) overrange.
  3. Error Event: {NBP} measurement range exceeded, i.e., the signal is out of the physiological range that is specified in the Metric object.
urn:iso:std:iso:11073:10101   196974 icon MDC_EVT_MSMT_RANGE_UNDER
  1. Error Event: Metric (measurement) underrange
  2. {NBP} metric (measurement) underrange.
urn:iso:std:iso:11073:10101   196976 icon MDC_EVT_PRESS_HI_GT_LIM

High pressure

urn:iso:std:iso:11073:10101   196978 icon MDC_EVT_PRESS_HI_VAL_GT_LIM

High pressure

urn:iso:std:iso:11073:10101   196980 icon MDC_EVT_PRESS_SUBATMOS
  1. Pressure subatmospheric [Vent]
  2. [Vent] Pressure subatmospheric.
urn:iso:std:iso:11073:10101   196982 icon MDC_EVT_PRESS_SUPPLY_HI
  1. High supply pressure
  2. Supply pressure high.
urn:iso:std:iso:11073:10101   196984 icon MDC_EVT_PRESS_SUPPLY_LO
  1. Low supply pressure
  2. Supply pressure low.
urn:iso:std:iso:11073:10101   196986 icon MDC_EVT_PRESS_CUFF_OVER
  1. Cuff over pressure
  2. {NBP} cuff overpressure.
urn:iso:std:iso:11073:10101   196988 icon MDC_EVT_SIG_LO
  1. Signal is low
  2. {SpO2} signal low.
urn:iso:std:iso:11073:10101   196992 icon MDC_EVT_SIG_UNANALYZEABLE
  1. Error Event: Signal Cannot Be Analyzed (for any secondary derived measurement when the input signal is bad)
  2. Error Event: Signal Cannot Be Analyzed (for any secondary derived measurement when the input signal is bad). [For example, {ECG QT} measurement is unanalyzable.]
urn:iso:std:iso:11073:10101   196996 icon MDC_EVT_SIG_RANGE_OVER
  1. Signal is overrange
  2. Signal out of physical range.
urn:iso:std:iso:11073:10101   196998 icon MDC_EVT_SIG_RANGE_UNDER
  1. Signal is underrange
  2. Signal out of range.
urn:iso:std:iso:11073:10101   197000 icon MDC_EVT_SIG_STRENGTH_WEAK
  1. Signal is weak
  2. {SvO2} signal strength is weak.
urn:iso:std:iso:11073:10101   197002 icon MDC_EVT_TEMP_HI_GT_LIM
  1. Temperature exceeds limit
  2. Temperature high: > limit.
urn:iso:std:iso:11073:10101   197004 icon MDC_EVT_TEMP_HI_VAL_GT_LIM
  1. Temperature value exceeds limit
  2. Temperature high: value > limit.
urn:iso:std:iso:11073:10101   197006 icon MDC_EVT_UNIT_INVALID
  1. Unit of measurement invalid
  2. Unit of measurement invalid.
urn:iso:std:iso:11073:10101   197008 icon MDC_EVT_UNSUPPORTED
  1. A component (sensor, module) is not supported
  2. {CCO} unsupported.
urn:iso:std:iso:11073:10101   197010 icon MDC_EVT_MSG_NOM_ERR

A message contains wrong code.

urn:iso:std:iso:11073:10101   197012 icon MDC_EVT_SIG_GAIN_LO
  1. Signal gain low: probably erroneous data extraction
  2. Signal gain low: probably erroneous data extraction.
urn:iso:std:iso:11073:10101   197014 icon MDC_EVT_OP_INVALID
  1. Unspecified handling error
  2. Unspecified handling error.
urn:iso:std:iso:11073:10101   197016 icon MDC_EVT_MATERIAL_LOW_OR_OUT

Unspecified tools or agents (e.g., calibration fluids) are low.

urn:iso:std:iso:11073:10101   197018 icon MDC_EVT_AL_LIMIT
  1. Alarm limit exceeded
  2. Alarm Limit.
urn:iso:std:iso:11073:10101   197020 icon MDC_EVT_QOS
  1. Communication error: quality of service (QOS)
  2. Unspecified Quality of Service event.
urn:iso:std:iso:11073:10101   197022 icon MDC_EVT_TIMING
  1. Unspecified timing error
  2. Unspecified timing error.
urn:iso:std:iso:11073:10101   197024 icon MDC_EVT_MSG_ERR_PROC
  1. Unspecified processing error message
  2. Messaging Error.
urn:iso:std:iso:11073:10101   197026 icon MDC_EVT_COMPUT_UNDERFLOW

Underflow was detected in a measurement or calculation.

urn:iso:std:iso:11073:10101   197028 icon MDC_EVT_PROC
  1. Unspecified processing error
  2. Unspecified processing event.
urn:iso:std:iso:11073:10101   197030 icon MDC_EVT_VENT_DELIV_O2_LO
  1. Ventilator - low O2 delivery
  2. Ventilator - low O2 delivery (concentration or flow).
urn:iso:std:iso:11073:10101   197034 icon MDC_EVT_SYNCH
  1. Synchronization event for synchronization of different processes
  2. Synchronization event for synchronization of different processes.
urn:iso:std:iso:11073:10101   197038 icon MDC_EVT_CUFF_POSN_ERR
  1. Cuff improperly placed
  2. {NBP} cuff has not been positioned correctly.
urn:iso:std:iso:11073:10101   197040 icon MDC_EVT_WAVE_ARTIF_ERR
  1. Artifact is detected in a waveform.
  2. Artifact is detected in a {*} waveform.
urn:iso:std:iso:11073:10101   197042 icon MDC_EVT_WAVE_SIG_QUAL_ERR

Disturbed waveform: result may be erroneous.

urn:iso:std:iso:11073:10101   197044 icon MDC_EVT_MSMT_INTERF_ERR
  1. Interference in measurement
  2. Error due to interference in measurement
urn:iso:std:iso:11073:10101   197046 icon MDC_EVT_WAVE_SHAPE_ABNORM

Shape/amplitude of waveform is abnormal.

urn:iso:std:iso:11073:10101   197048 icon MDC_EVT_SIG_NOISY

Noisy signal: result may be erroneous.

urn:iso:std:iso:11073:10101   197050 icon MDC_EVT_WAVE_OSCIL_ABSENT

Oscillation in waveform is expected, but not found.

urn:iso:std:iso:11073:10101   197052 icon MDC_EVT_SIG_ABSENT
  1. Typically, a zero voltage signal
  2. Typically, a zero voltage signal.
urn:iso:std:iso:11073:10101   197054 icon MDC_EVT_SIG_OUT_OF_RANGE
  1. Signal is out of range.
  2. {SvO2} signal is out of range.
urn:iso:std:iso:11073:10101   197056 icon MDC_EVT_SIG_PROC_ERR
  1. Unspecified signal processing error
  2. Unspecified signal processing error.
urn:iso:std:iso:11073:10101   197058 icon MDC_EVT_LIMIT_AL_HI

A metric exceeds a given threshold.

urn:iso:std:iso:11073:10101   197060 icon MDC_EVT_MSG_CORRUPT

Subsystem has received false data packet.

urn:iso:std:iso:11073:10101   197062 icon MDC_EVT_NBP_MOTION_DETEC
  1. Motions are detected, e.g., in NIBP measurement.
  2. NBP motion artifact has been detected.
urn:iso:std:iso:11073:10101   197064 icon MDC_EVT_NBP_CUFF_DISCONN_OR_LEAK
  1. Cuff is disconnected or leaking, e.g., in NIBP.
  2. NBP cuff is disconnected or leaking.
urn:iso:std:iso:11073:10101   197066 icon MDC_EVT_POWER_SUPPLY_PROB
  1. Problem in power supply
  2. {*} power supply problem.
urn:iso:std:iso:11073:10101   197068 icon MDC_EVT_VOLTAGE_OUT_OF_RANGE

Signal voltage is out of range.

urn:iso:std:iso:11073:10101   197070 icon MDC_EVT_CO2_MSMT_FAIL
  1. Failure occurred in a CO2 measuring device.
  2. A failure occurred in the airway CO2 measuring device.
urn:iso:std:iso:11073:10101   197072 icon MDC_EVT_CO2_SENSOR_FAIL
  1. Fault occurred in carbon dioxide sensor disc.
  2. A fault occurred in the airway CO2 sensor.
urn:iso:std:iso:11073:10101   197074 icon MDC_EVT_VENT_CYC_INSP_START
  1. Sync puls: Start of ventilator inspiratory cycle
  2. Sync puls: Start of ventilator inspiratory cycle.
urn:iso:std:iso:11073:10101   197076 icon MDC_EVT_COMM
  1. Communication error: NOS
  2. Unspecified communication event.
urn:iso:std:iso:11073:10101   197078 icon MDC_EVT_MSG_SEMAN_ERR

Subsystem has received false data packet.

urn:iso:std:iso:11073:10101   197080 icon MDC_EVT_FRAM_ERR
  1. Communication error: framing error
  2. Communication error: framing error.
urn:iso:std:iso:11073:10101   197082 icon MDC_EVT_PARITY_ERR
  1. Communication error: parity error
  2. Communication error: parity error.
urn:iso:std:iso:11073:10101   197084 icon MDC_EVT_DOOR_POSN_ERR
  1. A door or handle, which must be closed for operation, is open.
  2. Door Open
urn:iso:std:iso:11073:10101   197086 icon MDC_EVT_MSG_SYNTAX_UNDEF
  1. Undefined communication message syntax
  2. Undefined communication message syntax.
urn:iso:std:iso:11073:10101   197088 icon MDC_EVT_TIMER_SYNCH_TICK
  1. Timer tick of real-time clock for synchronization of all processes
  2. Timer tick of real-time clock for synchronization of all processes.
urn:iso:std:iso:11073:10101   197090 icon MDC_EVT_DATA_ACQN_ERR
  1. Unspecified problem in data acquisition
  2. Unspecified problem in data acquisition.
urn:iso:std:iso:11073:10101   197092 icon MDC_EVT_LIGHT_ON
  1. Error Event: Lights in the (sleep measurement) room are switched on {status lights on/off}
  2. Lights in the {sleep measurement} room are switched on (or device status or illumination lights are on).
urn:iso:std:iso:11073:10101   197094 icon MDC_EVT_TEMP_ENVIRON_LOW_ABNORM
  1. Abnormal low environmental temperature
  2. Abnormal low environmental temperature.
urn:iso:std:iso:11073:10101   197096 icon MDC_EVT_TEMP_ENVIRON_HI_ABNORM
  1. Abnormal high environmental temperature
  2. Abnormal high environmental temperature.
urn:iso:std:iso:11073:10101   197098 icon MDC_EVT_HUMID_EXCESS
  1. Too much humidity for accurate measurement
  2. Too much humidity for accurate measurement.
urn:iso:std:iso:11073:10101   197102 icon MDC_EVT_SIG_ABSENT_OSCIL
  1. Oscillation in signal is absent
  2. No oscillation.
urn:iso:std:iso:11073:10101   197104 icon MDC_EVT_SIG_AMPL_INVALID
  1. Signal amplitude is not as expected
  2. Invalid signal - shape/amplitude of signal unnormal.
urn:iso:std:iso:11073:10101   197106 icon MDC_EVT_SIG_RATE_EQU
  1. Pulserate coincidence
  2. Pulserate coincidence.
urn:iso:std:iso:11073:10101   197108 icon MDC_EVT_SIG_ARTIFACT
  1. Signal artifact detected
  2. {ECG} Artifact
urn:iso:std:iso:11073:10101   197110 icon MDC_EVT_BUFF_OVERFLOW
  1. Communication timing error: buffer overflow
  2. Communication timing error: buffer overflow.
urn:iso:std:iso:11073:10101   197112 icon MDC_EVT_VENT_TEMP_AWAY_HI

Airway temperature is too high (ventilator).

urn:iso:std:iso:11073:10101   197114 icon MDC_EVT_TEMP_ERR_ENVIRON
  1. Abnormal environmental temperature
  2. Abnormal environmental temperature.
urn:iso:std:iso:11073:10101   197116 icon MDC_EVT_VENT_ENDOTRACH_TUBE_OBSTRUC
  1. Example: obstruction of the endotracheal tube
  2. Example: obstruction of the endotracheal tube.
urn:iso:std:iso:11073:10101   197118 icon MDC_EVT_VENT_VOL_BREATHING_IRREG

Breathing volume is not constant.

urn:iso:std:iso:11073:10101   197120 icon MDC_EVT_VENT_VOL_MSMT_INOP

The volume measurement in a ventilator is inoperable.

urn:iso:std:iso:11073:10101   197122 icon MDC_EVT_RESPIRATOR_TEMP_HI

Respirator device temperature is too high.

urn:iso:std:iso:11073:10101   197124 icon MDC_EVT_VENT_GAS_AGENT_NOT_SELECTED

The gas agent must be selected for it to be measured by the airway gas analyzer.

urn:iso:std:iso:11073:10101   197126 icon MDC_EVT_VENT_SYNCH_INOP
  1. Ventilator synchronization inoperable
  2. Ventilator synchronization inoperable.
urn:iso:std:iso:11073:10101   197128 icon MDC_EVT_FLOW_DISTURB
  1. Flow is disturbed
  2. {Pump} flow impediment.
urn:iso:std:iso:11073:10101   197130 icon MDC_EVT_VENT_EXP_VALVE_STUCK
  1. The expiratory valve is stuck.
  2. Example: the expiratory valve is stuck.
urn:iso:std:iso:11073:10101   197132 icon MDC_EVT_TIME_PD_DELIV_COMP
  1. A specified period for delivery has elapsed
  2. Configured time to deliver whole syringe/bottle is over.
urn:iso:std:iso:11073:10101   197134 icon MDC_EVT_DEV_STAT_RPT

Device status report.

urn:iso:std:iso:11073:10101   197136 icon MDC_EVT_VENT_MIX_IRIS_INOP

Gaseous agent mixing iris is inoperable in a ventilator (anesthesia).

urn:iso:std:iso:11073:10101   197138 icon MDC_EVT_TIME_PD_STANDBY_COMP
  1. A specified period for stnadby has elapsed
  2. Standby Time Expired
urn:iso:std:iso:11073:10101   197140 icon MDC_EVT_VENT_BREATHING_SYS_VENTED

Breathing system is vented.

urn:iso:std:iso:11073:10101   197142 icon MDC_EVT_VENT_CO2_ABSORB_EXH
  1. Exhausted carbon dioxide absorber
  2. Exhausted carbon dioxide absorber.
urn:iso:std:iso:11073:10101   197144 icon MDC_EVT_VENT_CO2_SENSOR_LINE_OBSTRUC

The airway CO2 gas sampling line is blocked.

urn:iso:std:iso:11073:10101   197146 icon MDC_EVT_VENT_ENDOTRACH_TUBE_OCCL
  1. Example: occlusion of the endotracheal tube
  2. Example: occlusion of the endotracheal tube.
urn:iso:std:iso:11073:10101   197148 icon MDC_EVT_VENT_TEMP_HI

Ventilator device temperature is too high.

urn:iso:std:iso:11073:10101   197150 icon MDC_EVT_VENT_COMPONENT_DISCONN
  1. Disconnection of parts in a ventilator, e.g., disconnection in FGF hose
  2. Disconnection of a part (or parts) in a ventilator, e.g., disconnection in FGF hose.
urn:iso:std:iso:11073:10101   197154 icon MDC_EVT_VENT_PRESS_O2_INSP_INOP
  1. Inoperable inspiratory Omeasurement
  2. The inspiratory O2 pressure sensor is inoperable.
urn:iso:std:iso:11073:10101   197156 icon MDC_EVT_VENT_GAS_LINE_PROB
  1. Problem with gas lines to/from breathing system
  2. Problem with gas lines to/from breathing system.
urn:iso:std:iso:11073:10101   197158 icon MDC_EVT_VENT_GAS_MIXER_INOP

Gas mixer is inoperable.

urn:iso:std:iso:11073:10101   197160 icon MDC_EVT_VENT_BREATHING_SYS_LEAK
  1. Leak in breathing system
  2. Leak in breathing system detected.
urn:iso:std:iso:11073:10101   197162 icon MDC_EVT_LIMIT_AL_LO

A metric falls short of a given threshold.

urn:iso:std:iso:11073:10101   197166 icon MDC_EVT_PRESS_FLUID_LINE_EXCESS
  1. High pressure in fluid line
  2. Too much pressure in line.
urn:iso:std:iso:11073:10101   197168 icon MDC_EVT_POWER_PROB

Problem in power supply

urn:iso:std:iso:11073:10101   197170 icon MDC_EVT_ENVIRON
  1. Unspecified device environment warning
  2. Unspecified environment(al) event.
urn:iso:std:iso:11073:10101   197172 icon MDC_EVT_VENT_DISCONN

Patient is disconnected from ventilator.

urn:iso:std:iso:11073:10101   197174 icon MDC_EVT_SYRINGE_TIMEOUT_WARN
  1. Advisory: Syringe has taken longer than expec ted time
  2. Syringe pre-alarm (x minutes).
urn:iso:std:iso:11073:10101   197176 icon MDC_EVT_USER_INPUT_DATA_VAL_ERR_HI

User keyboard input is higher than available with syringe type (pump).

urn:iso:std:iso:11073:10101   197178 icon MDC_EVT_VENT_INOP
  1. Ventilator is inoperable
  2. The ventilator is inoperable.
urn:iso:std:iso:11073:10101   197180 icon MDC_EVT_VENT_STUCK
  1. An unspecified component of the ventilator is stuck in position [if the expiratory valve is specifically known to be stuck, use MDC_EVT_VENT_EXP_VALVE_STUCK (3::522)]
  2. {Expiratory valve} is stuck.
urn:iso:std:iso:11073:10101   197182 icon MDC_EVT_PUMP_SYRINGE_DELIV_TIMEOUT

Configured time to deliver whole syringe/bottle is over.

urn:iso:std:iso:11073:10101   197184 icon MDC_EVT_FLOW_OBSTRUC
  1. Flow is obstructed.
  2. {Pump} flow is hindered.
urn:iso:std:iso:11073:10101   197186 icon MDC_EVT_HUMID_HI_ERR
  1. Too much humidity for accurate measurement
  2. Too much humidity for accurate measurement.
urn:iso:std:iso:11073:10101   197188 icon MDC_EVT_FLUID_LINE_HI_GT_LIM_PRESSURE
  1. High pressure in fluid line
  2. Too much pressure in line.
urn:iso:std:iso:11073:10101   197190 icon MDC_EVT_FLOW_FLUID_LINE_RES_WARN
  1. Advisory: Flow resistance warning
  2. Flow resistance warning.
urn:iso:std:iso:11073:10101   197192 icon MDC_EVT_TIMEOUT

Timeout: device should be either operated or turned off.

urn:iso:std:iso:11073:10101   197194 icon MDC_EVT_PUMP_VOL_TBI_COMP
  1. Total volume infused (pump)
  2. Total programmed volume infused (pump).
  3. Infusion complete, where the programmed volume has been infused (pump).
urn:iso:std:iso:11073:10101   197196 icon MDC_EVT_DISPOS_LO
  1. Disposables low or out
  2. Disposables low or out.
urn:iso:std:iso:11073:10101   197198 icon MDC_EVT_EQUIP
  1. Unspecified equipment event
  2. Unspecified Equipment event.
urn:iso:std:iso:11073:10101   197200 icon MDC_EVT_FLUID_LINE_AIR

Air in fluid line.

urn:iso:std:iso:11073:10101   197202 icon MDC_EVT_VENT_FLOW_O2_DELIV_LO
  1. Too low O2 delivery (flow)
  2. Too low oxygen delivery (flow).
urn:iso:std:iso:11073:10101   197204 icon MDC_EVT_VENT_CONC_O2_DELIV_LO
  1. Too low O2 delivery (concentration)
  2. Too low oxygen delivery (concentration).
urn:iso:std:iso:11073:10101   197206 icon MDC_EVT_PUMP_FLOW_FREE
  1. Pump in free flow
  2. Pump in free flow.
urn:iso:std:iso:11073:10101   197208 icon MDC_EVT_INCOMPAT
  1. Incompatibility of nomenclature or processing component, etc.
  2. This version of the {NMT} measurement module is not supported, or the module firmware is incomplete and needs to be upgraded.
urn:iso:std:iso:11073:10101   197210 icon MDC_EVT_MULT_REPLY_UNAVAIL

The multiple reply remote operation function is not available (see Clause 6 in ISO/IEEE 11073-20101:2004)

urn:iso:std:iso:11073:10101   258047 icon MDC_EVT_NOS
  1. Event, non-specific [NOS] (This code is unusual as it applies only to an object.)
  2. Event, non-specific [NOS]
urn:iso:std:iso:11073:10101   199680 icon MDC_EVT_APNEA
  1. No breathing within a pre-configured time span
  2. Apnea
urn:iso:std:iso:11073:10101   199682 icon MDC_EVT_ECG_NOT_PACED
  1. Beat not paced
  2. No pacer detected
urn:iso:std:iso:11073:10101   199684 icon MDC_EVT_ECG_ASYSTOLE

No QRS-complex found in predefined time period

urn:iso:std:iso:11073:10101   199686 icon MDC_EVT_ECG_BEAT_MISSED

Missed beat within some regular ECG rhythm

urn:iso:std:iso:11073:10101   199688 icon MDC_EVT_ECG_BEAT_UNUSUAL
  1. Unusual beat within some regular ECG rhythm
  2. Unusual beat
urn:iso:std:iso:11073:10101   199690 icon MDC_EVT_ECG_BIGEM
  1. Ventricular bigemini: a specific rhythm
  2. Ventricular bigeminy
  3. Ventricular bigeminy: a specific rhythm
urn:iso:std:iso:11073:10101   199692 icon MDC_EVT_ECG_SINUS_BRADY
  1. Bradycardia
  2. Sinus bradycardia
urn:iso:std:iso:11073:10101   199694 icon MDC_EVT_ECG_BRADY_EXTREME

Limit Event: Extreme Bradycardia (escalated low HR limit, not a brady rhythm)

urn:iso:std:iso:11073:10101   199696 icon MDC_EVT_ECG_BRADY_SUST
  1. Sustained Bradycardia
  2. Sustained bradycardia.
urn:iso:std:iso:11073:10101   199700 icon MDC_EVT_ECG_FIB
  1. Fibrillation (non-specific)
  2. Fibrillation
urn:iso:std:iso:11073:10101   199702 icon MDC_EVT_ECG_NO_ECT_BEAT
  1. No Ectopic beat
  2. No ectopic beat
urn:iso:std:iso:11073:10101   199704 icon MDC_EVT_ECG_PACED_BEAT

Pacer pulse sensed by heart

urn:iso:std:iso:11073:10101   199706 icon MDC_EVT_STAT_ECG_PACING

Pacer operational and controlling heart rhythm

urn:iso:std:iso:11073:10101   199708 icon MDC_EVT_ECG_PACING_CAPT
  1. Pacing captured (recognized by heart)
  2. Pacing capture
urn:iso:std:iso:11073:10101   199710 icon MDC_EVT_ECG_PACING_NON_CAPT
  1. Pacer not captured (not recognized by heart)
  2. Pacing not captured (not recognized by heart)
urn:iso:std:iso:11073:10101   199712 icon MDC_EVT_ECG_PACING_RUN
  1. Run of paced beats
  2. Pacing Run
urn:iso:std:iso:11073:10101   199714 icon MDC_EVT_ECG_PATT

Unspecified ECG (arrhythmia) event

urn:iso:std:iso:11073:10101   199716 icon MDC_EVT_ECG_PAUSE
  1. Prolonged RR interval, due to any reason
  2. Pause
urn:iso:std:iso:11073:10101   199718 icon MDC_EVT_ECG_QUADRIGEM

Quadrigeminy

urn:iso:std:iso:11073:10101   199720 icon MDC_EVT_ECG_RHY

Rhythm

urn:iso:std:iso:11073:10101   199722 icon MDC_EVT_ECG_RHY_ABSENT

No [cardiac] rhythm

urn:iso:std:iso:11073:10101   199724 icon MDC_EVT_ECG_RHY_ECT

Ectopic rhythm

urn:iso:std:iso:11073:10101   199726 icon MDC_EVT_ECG_RR_IRREG

Irregular rhythm

urn:iso:std:iso:11073:10101   199728 icon MDC_EVT_ECG_TACHY

Tachycardia

urn:iso:std:iso:11073:10101   199730 icon MDC_EVT_ECG_TACHY_EXTREME

Limit Event: Extreme Tachycardia (escalated high HR limit, not a tachy rhythm)

urn:iso:std:iso:11073:10101   199732 icon MDC_EVT_ECG_TACHY_UNSPEC
  1. Tacycardia (unspecified)
  2. Tachycardia Unspecified
urn:iso:std:iso:11073:10101   199734 icon MDC_EVT_ECG_TRIGEM
  1. Ventricular trigeminy
  2. Trigeminy
urn:iso:std:iso:11073:10101   199736 icon MDC_EVT_ECG_ATR_FIB

Atrial fibrillation

urn:iso:std:iso:11073:10101   199738 icon MDC_EVT_ECG_ATR_P_C

Premature atrial contraction

urn:iso:std:iso:11073:10101   199740 icon MDC_EVT_ECG_ATR_PACING
  1. Atrial Pacing
  2. Atrial Pacing.
urn:iso:std:iso:11073:10101   199742 icon MDC_EVT_ECG_ATR_STAND
  1. Atrial standstill
  2. Atrial Standstill.
urn:iso:std:iso:11073:10101   199744 icon MDC_EVT_ECG_ATR_TACHY

Atrial tachycardia

urn:iso:std:iso:11073:10101   199746 icon MDC_EVT_ECG_ATR_TACHY_MULTIFOCAL
  1. Atrial tachycardia multifocal
  2. Atrial Tachycardia Multifocal
urn:iso:std:iso:11073:10101   199748 icon MDC_EVT_ECG_ATR_TACHY_PAROX
  1. Atrial tachycardia paroxysmal
  2. Atrial Tachycardia Paroxysmal
urn:iso:std:iso:11073:10101   199750 icon MDC_EVT_ECG_AV_DISSOC
  1. AV Disassociation
  2. AV Dissociation
urn:iso:std:iso:11073:10101   199752 icon MDC_EVT_ECG_AV_PACING_SEQ

AV Pacing Sequential

urn:iso:std:iso:11073:10101   199754 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_1
  1. AV block 1°.
  2. AV block 1°
urn:iso:std:iso:11073:10101   199756 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2
  1. AV block 2°.
  2. AV block 2°
urn:iso:std:iso:11073:10101   199758 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_I
  1. AV block 2, Type I
  2. AV Heart Block Degree 2 Type I
urn:iso:std:iso:11073:10101   199760 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_II
  1. AV block 2, Type II
  2. AV Heart Block Degree 2 Type II
urn:iso:std:iso:11073:10101   199762 icon MDC_EVT_ECG_BB_BLK
  1. Bundle Branch block
  2. Bundle Branch Block
urn:iso:std:iso:11073:10101   199764 icon MDC_EVT_ECG_CARD_BEAT_RATE_HI
  1. High heart rate
  2. High Heart Rate
urn:iso:std:iso:11073:10101   199766 icon MDC_EVT_ECG_CARD_BEAT_RATE_IRREG

Error Event: Irregular heart rate (which means the beat detector finds a highly variable heart rate and cannot derive a consistent/stable value)

urn:iso:std:iso:11073:10101   199768 icon MDC_EVT_ECG_CARD_BEAT_RATE_LO
  1. Low heart rate
  2. Low Heart Rate
urn:iso:std:iso:11073:10101   199770 icon MDC_EVT_ECG_CARD_BEAT
  1. Heartbeat
  2. [Heart] Beat
urn:iso:std:iso:11073:10101   199772 icon MDC_EVT_ECG_HEART_DYING
  1. Dying heart
  2. Dying Heart
urn:iso:std:iso:11073:10101   199774 icon MDC_EVT_ECG_HEART_BLK
  1. Heart block
  2. Heart Block
urn:iso:std:iso:11073:10101   199776 icon MDC_EVT_ECG_HEART_BLK_COMP
  1. Complete Heart block
  2. Heart Block Complete
urn:iso:std:iso:11073:10101   199778 icon MDC_EVT_ECG_JUNC_P_C
  1. Junctional premature contraction
  2. Premature Contraction, Junctional
urn:iso:std:iso:11073:10101   199780 icon MDC_EVT_ECG_JUNC_TACHY

Junctional tachycardia

urn:iso:std:iso:11073:10101   199782 icon MDC_EVT_ECG_JUNC_TACHY_PAROX
  1. Paroxysmal Junctional tachycardia
  2. Paroxysmal supraventricular tachycardia
urn:iso:std:iso:11073:10101   199784 icon MDC_EVT_ECG_LA_FASC_BLK
  1. Left Anterior Fascicular Block
  2. Fascicular Block. LA.
urn:iso:std:iso:11073:10101   199786 icon MDC_EVT_ECG_LBB_BLK
  1. Left Bundle Branch block
  2. Left Bundle Branch Block
urn:iso:std:iso:11073:10101   199788 icon MDC_EVT_ECG_LP_FASC_BLK
  1. Left Posterior Fascicular Block
  2. Fascicular Block. LP
urn:iso:std:iso:11073:10101   199790 icon MDC_EVT_ECG_PACER_NOT_PACING

Pacer (device) not sensing

urn:iso:std:iso:11073:10101   199792 icon MDC_EVT_ECG_PT_NOT_PACED
  1. Patient not paced
  2. Patient Not Paced
urn:iso:std:iso:11073:10101   199794 icon MDC_EVT_ECG_RBB_BLK
  1. Right Bundle Branch block
  2. Right Bundle Branch Block
urn:iso:std:iso:11073:10101   199796 icon MDC_EVT_ECG_SV_BEAT
  1. Supraventricular beat
  2. SV Beat
urn:iso:std:iso:11073:10101   199798 icon MDC_EVT_ECG_SV_P_C

Supraventricular extrasystole

urn:iso:std:iso:11073:10101   199800 icon MDC_EVT_ECG_SV_TACHY

Supraventricular tachycardia

urn:iso:std:iso:11073:10101   199802 icon MDC_EVT_ECG_V_PARASYS

Ventricular parasystole

urn:iso:std:iso:11073:10101   199804 icon MDC_EVT_ECG_V_BIGEM
  1. Ventricular bigeminy
  2. Ventriclular bigeminy
urn:iso:std:iso:11073:10101   199806 icon MDC_EVT_ECG_V_FIB

Ventricular fibrillation

urn:iso:std:iso:11073:10101   199810 icon MDC_EVT_ECG_V_FLUT

Ventricular flutter

urn:iso:std:iso:11073:10101   199812 icon MDC_EVT_ECG_V_P_C

Premature ventricular contraction

urn:iso:std:iso:11073:10101   199814 icon MDC_EVT_ECG_V_P_C_RonT

Premature ventricular contraction, R-on-T

urn:iso:std:iso:11073:10101   199816 icon MDC_EVT_ECG_V_P_C_MULTIFORM

Multiformed premature ventricular contractions

urn:iso:std:iso:11073:10101   199818 icon MDC_EVT_ECG_V_P_C_PAIR

Pair of premature ventricular contractions

urn:iso:std:iso:11073:10101   199820 icon MDC_EVT_ECG_V_P_C_RUN

Several consecutive ventricular extrasystoles

urn:iso:std:iso:11073:10101   199822 icon MDC_EVT_ECG_V_P_C_TRIP

VPC Triplet

urn:iso:std:iso:11073:10101   199824 icon MDC_EVT_ECG_V_PACING
  1. Ventricular Pacing
  2. Ventricular pacing
urn:iso:std:iso:11073:10101   199826 icon MDC_EVT_ECG_V_QUADRIGEM
  1. Ventricular quadrigeminy
  2. Ventricular Quadrigeminy
urn:iso:std:iso:11073:10101   199828 icon MDC_EVT_ECG_V_RHY

Ventricular rhythm: escalation of Run of PVC, not yet flutter

urn:iso:std:iso:11073:10101   199830 icon MDC_EVT_ECG_V_STAND
  1. Ventricular standstill
  2. Ventricular Standstill
urn:iso:std:iso:11073:10101   199832 icon MDC_EVT_ECG_V_TACHY

Ventricular tachycardia

urn:iso:std:iso:11073:10101   199834 icon MDC_EVT_ECG_V_TACHY_NON_SUST
  1. Ventricular tachycardia, Non-sustained
  2. Ventricular Tachycardia, Non-sustained
urn:iso:std:iso:11073:10101   199836 icon MDC_EVT_ECG_V_TACHY_SUST
  1. Ventricular tachycardia, Sustained
  2. Ventricular Tachycardia, Sustained
urn:iso:std:iso:11073:10101   199838 icon MDC_EVT_ECG_V_TACHY_TORSADE
  1. Ventricular tachycardia, Torsades de Pointes
  2. Torsades de Pointes
urn:iso:std:iso:11073:10101   199840 icon MDC_EVT_ECG_V_TACHY_RHY
  1. Ventricular tachycardia Rhythm
  2. Ventricular Tachycardia Rhythm
urn:iso:std:iso:11073:10101   199842 icon MDC_EVT_ECG_V_TACHY_RHY_SUST
  1. Ventricular tachycardia Rhythm, Sustained
  2. Vent Tachycardia Rhythm, Sustained
urn:iso:std:iso:11073:10101   199844 icon MDC_EVT_ECG_V_TRIGEM
  1. Ventricular trigemini: a specific rhythm
  2. Ventricular trigeminy
  3. Ventricular trigeminy: a specific rhythm
urn:iso:std:iso:11073:10101   199846 icon MDC_EVT_ECG_V_TRIGEM_RHY
  1. Ventricular trigeminy rhythm
  2. Ventricular Trigeminy Rhythm
urn:iso:std:iso:11073:10101   199848 icon MDC_EVT_ECG_STAT_ECT
  1. Current ectopic rhythm status: conveys an enumerated summary of the predominant ECG ectopic rhythm type(s) over the reporting time interval
  2. Present ectopic arrhythmia type; "present" implies user-defined time-constant (e.g. within last minute).
urn:iso:std:iso:11073:10101   199850 icon MDC_EVT_ECG_STAT_RHY
  1. Current rhythm status: conveys an enumerated summary of the predominant ECG rhythm type(s) over the reporting time interval
  2. Present rhythm; "present" implies user-defined time-constant (e.g. within last minute)
urn:iso:std:iso:11073:10101   199852 icon MDC_EVT_UNEQU_HR_AND_PR

Cardiac and Pulse Rates are unequal

urn:iso:std:iso:11073:10101   199854 icon MDC_EVT_DESAT
  1. Limit Event: Desaturation (escalated low oxygen alarm, used esp. in neonatal)
  2. SpO2 Desaturation
urn:iso:std:iso:11073:10101   199856 icon MDC_EVT_ECG_SV_P_C_RUN

Several consecutive supraventricular extrasystoles

urn:iso:std:iso:11073:10101   199860 icon MDC_EVT_ECG_V_P_C_RATE

A specific limit alert on the PVC rate

urn:iso:std:iso:11073:10101   199862 icon MDC_EVT_EEG_SPK_AND_WV

Spikes and waves in EEG

urn:iso:std:iso:11073:10101   199864 icon MDC_EVT_RESP_VOL_BREATHING_IRREG

Breathing volume not constant

urn:iso:std:iso:11073:10101   199866 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_3
  1. AV block 3°.
  2. AV block 3°
urn:iso:std:iso:11073:10101   199868 icon MDC_EVT_ECG_JUNC_RHY

Junctional rhythm

urn:iso:std:iso:11073:10101   199870 icon MDC_EVT_ECG_SINUS_TACHY

Sinus tachycardia

urn:iso:std:iso:11073:10101   199872 icon MDC_EVT_EEG_DISCHG_SEIZ_CLIN

Clinical seizure discharge in EEG

urn:iso:std:iso:11073:10101   199874 icon MDC_EVT_ECG_ARRHY

Unspecified ECG (arrhythmia) event

urn:iso:std:iso:11073:10101   199876 icon MDC_EVT_EEG_DISCHG_EPILEPTIFORM

Epileptiform discharges in EEG

urn:iso:std:iso:11073:10101   199878 icon MDC_EVT_EEG_SPK_SHARP

Sharp spikes in EEG

urn:iso:std:iso:11073:10101   199880 icon MDC_EVT_ECG_RHY_CPLT

Couplet

urn:iso:std:iso:11073:10101   199882 icon MDC_EVT_ECG_V_P_C_FREQ

Frequent premature ventricular contractions

urn:iso:std:iso:11073:10101   199884 icon MDC_EVT_ECG_ATR_FLUT

Atrial flutter

urn:iso:std:iso:11073:10101   199886 icon MDC_EVT_RESP_BREATHING_SPONT_ASSIST_PSW
  1. Assisted spontaneous breathing longer than a predefined time span (PSW)
  2. Assisted spontaneous breathing longer then a predefined time span (PSW)
urn:iso:std:iso:11073:10101   199888 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2_1

2:1 AV block

urn:iso:std:iso:11073:10101   199890 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_3_1

3:1 AV block

urn:iso:std:iso:11073:10101   199892 icon MDC_EVT_VENT_RESP_APNEA_15_SEC

Apnea - pressure absent for 15 seconds

urn:iso:std:iso:11073:10101   199894 icon MDC_EVT_ECG_PACER_ABSENT

No pacer detected

urn:iso:std:iso:11073:10101   199896 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_4_1

4:1 AV block

urn:iso:std:iso:11073:10101   199898 icon MDC_EVT_ECG_SV_P_C_FREQ

Frequent supraventricular extrasystoles

urn:iso:std:iso:11073:10101   199900 icon MDC_EVT_VENT_RESP_APNEA_30_SEC

Apnea - no volume exhale for 30 seconds

urn:iso:std:iso:11073:10101   199902 icon MDC_EVT_ECG_PACER_ARTIF_RECOG

Pacer artifact recognized

urn:iso:std:iso:11073:10101   199904 icon MDC_EVT_ERR_EQU_HR_AND_RR
  1. Heart rate and respiration rate are reported to be the same value.
  2. Cardiac and Respiration Rates are reported to be equal.
urn:iso:std:iso:11073:10101   199906 icon MDC_EVT_ECG_JUNC_ESC_BEATS
  1. Junctional escape beats
  2. Junctional Escape Beats.
urn:iso:std:iso:11073:10101   199908 icon MDC_EVT_ECG_JUNC_TACHY_RUN

Run of junctional tachycardia

urn:iso:std:iso:11073:10101   199910 icon MDC_EVT_EQU_HR_AND_PR

Cardiac and Pulse Rates are equal

urn:iso:std:iso:11073:10101   199912 icon MDC_EVT_EEG_BACK_ACTIV_ABSENT

Back Activity Absent

urn:iso:std:iso:11073:10101   199914 icon MDC_EVT_BACK_ACTIV_ASYM

Back Activity Asymmetric

urn:iso:std:iso:11073:10101   199916 icon MDC_EVT_PULS_NON_PULSATILE
  1. NIBP non pulsatile
  2. Pulse absent or non-pulsatile
urn:iso:std:iso:11073:10101   202752 icon MDC_EVT_STAT_AL_OFF
  1. Indication: Alarm Intentionally Off (disabled)
  2. Indication: Alarm Intentionally Off (disabled). [This term is deprecated; use MDC_EVT_STAT_AIS_ALARM_OFF instead.]
urn:iso:std:iso:11073:10101   202754 icon MDC_EVT_STAT_AL_ON
  1. Indication: Alarm Intentionally On (enabled)
  2. Indication: Alarm Intentionally On (enabled). [This term is deprecated; use MDC_EVT_STAT_AIS_ENABLED instead.]
urn:iso:std:iso:11073:10101   202756 icon MDC_EVT_STAT_BACKUP_MODE
  1. Indication: Device in Backup mode, No Measurement Possible
  2. Status: Backup mode.
urn:iso:std:iso:11073:10101   202758 icon MDC_EVT_STAT_BATT_CHARGING

Battery is now being recharged.

urn:iso:std:iso:11073:10101   202760 icon MDC_EVT_STAT_CALIB_MODE
  1. Indication: Device in Calibration mode, No Measurement Possible
  2. Calibration Mode or status [NOS].
urn:iso:std:iso:11073:10101   202762 icon MDC_EVT_STAT_CALIB_RUNNING
  1. Indication: Calibration in Progress, No Measurement Possible
  2. {SpO2} Sensor calibrating
urn:iso:std:iso:11073:10101   202764 icon MDC_EVT_STAT_CALIB_INVIVO_RUNNING
  1. Indication: Calibration of invivo probe in Progress, No Measurement Possible
  2. Status: Invivo Calibration running.
urn:iso:std:iso:11073:10101   202766 icon MDC_EVT_STAT_CALIB_LIGHT_RUNNING
  1. Indication: Calibration of light source in Progress, No Measurement Possible
  2. Status: Light Calibration running.
urn:iso:std:iso:11073:10101   202768 icon MDC_EVT_STAT_CALIB_PREINS_RUNNING
  1. Indication: Calibration of an optical (or other) sensor prior to insertion of a sensor/catheter
  2. Status: Pre-insertion Calibration running.
urn:iso:std:iso:11073:10101   202770 icon MDC_EVT_STAT_CONFIG
  1. Indication: Configuration in Progress, No Measurement Possible
  2. Status: Configuring {*}.
urn:iso:std:iso:11073:10101   202772 icon MDC_EVT_STAT_SELFTEST_RUNNING
  1. Indication: Self test in Progress, No Measurement Possible
  2. Status: {Cardiac output} self test running.
urn:iso:std:iso:11073:10101   202774 icon MDC_EVT_STAT_STANDBY_MODE
  1. Indication: In standby mode, No Measurement Possible
  2. Indication: standby.
urn:iso:std:iso:11073:10101   202776 icon MDC_EVT_STAT_TEST_RUNNING

Indication: Diagnostic test in Progress, No Measurement Possible

urn:iso:std:iso:11073:10101   202778 icon MDC_EVT_STAT_ZERO_RUNNING
  1. Indication: Zero calibration in Progress, No Measurement Possible
  2. Status: Zero running.
urn:iso:std:iso:11073:10101   202780 icon MDC_EVT_STAT_OPT_MOD_SENSOR_CONN
  1. Indication: Optical sensor connected
  2. Status: {SvO2} optical module connected.
urn:iso:std:iso:11073:10101   202782 icon MDC_EVT_STAT_OPT_MOD_SENSOR_WARMING
  1. Indication: Optical sensor warming in Progress, No Measurement Possible
  2. Status: {SvO2} optical module sensor or component warming up.
urn:iso:std:iso:11073:10101   202784 icon MDC_EVT_STAT_SENSOR_WARMING
  1. Indication: Sensor warming in Progress, No Measurement Possible
  2. Status: {Airway gas analyzer} sensor warming.
urn:iso:std:iso:11073:10101   202786 icon MDC_EVT_STAT_WARMING
  1. Indication: Device warming in Progress, No Measurement Possible
  2. Status: {*} sensor or component warming.
urn:iso:std:iso:11073:10101   202788 icon MDC_EVT_STAT_PRESS_SUST
  1. [Vent] Pressure sustained
  2. Status: [Vent] Pressure sustained.
urn:iso:std:iso:11073:10101   202790 icon MDC_EVT_STAT_ECG_AL_ALL_OFF

Status: All ECG alarms are off (still need these in France to meet French homologation, despite MDD).

urn:iso:std:iso:11073:10101   202792 icon MDC_EVT_STAT_ECG_AL_SOME_OFF

Status: Some ECG alarms are off (still need these in France to meet French homologation, despite MDD).

urn:iso:std:iso:11073:10101   202796 icon MDC_EVT_STAT_MODE_SIGH_ACTIVE

Sigh mode is active.

urn:iso:std:iso:11073:10101   202798 icon MDC_EVT_STAT_UNCALIB

VMD is not calibrated.

urn:iso:std:iso:11073:10101   202804 icon MDC_EVT_STAT_VENT_GAS_MIXER_FUNC_DISABL

The function of gaseous agent mixing iris in a ventilator (anesthesia machine) is disabled.

urn:iso:std:iso:11073:10101   202806 icon MDC_EVT_STAT_ACTIVE
  1. Active state of, e.g., device
  2. Active state of, e.g., device.
urn:iso:std:iso:11073:10101   202810 icon MDC_EVT_STAT_VENT_TIME_RESP_VOL_LIMITED
  1. Respiratory volume time is limited.
  2. Tidal volume is time limited.
urn:iso:std:iso:11073:10101   202814 icon MDC_EVT_STAT_VENT_PRESS_RESP_VOL_LIMITED
  1. Respiratory volume pressure is limited.
  2. Tidal volume is pressure limited.
urn:iso:std:iso:11073:10101   202818 icon MDC_EVT_STAT_VENT_AL_TACHAPNEA_DISABL
  1. Tachyapnea alarm in a ventilator is disabled.
  2. Tachyapnea alarm in a ventilator is disabled. [This term is deprecated; use MDC_EVT_STAT_VENT_TACHYPNEA_AIS_ALARM_OFF instead.]
urn:iso:std:iso:11073:10101   202820 icon MDC_EVT_STAT_CHARGING
  1. Charging state of, e.g., battery
  2. Charging state of, e.g., battery.
urn:iso:std:iso:11073:10101   202822 icon MDC_EVT_STAT_AL_SILENCE
  1. Alarm is silenced (speaker off).
  2. Alarm is silenced (speaker off). [This term is deprecated; use MDC_EVT_STAT_AIS_AUDIO_OFF instead.]
urn:iso:std:iso:11073:10101   202824 icon MDC_EVT_STAT_AL
  1. Alarm state of, e.g., device or signal
  2. Alarm state of, e.g., device or signal.
urn:iso:std:iso:11073:10101   202828 icon MDC_EVT_STAT_DOOR_OPEN
  1. Door in the (sleep measurement) room is opened.
  2. Door in the {sleep measurement} room is opened.
urn:iso:std:iso:11073:10101   202830 icon MDC_EVT_STAT_NBP_INFL_TO_MAX_CUFF_PRESS
  1. NIBP is inflating cuff to maximum cuff pressure.
  2. Noninvasive blood pressure device is inflating cuff to maximum cuff pressure.
urn:iso:std:iso:11073:10101   202832 icon MDC_EVT_STAT_LEARN
  1. Indication: Learning - analyzing waveform
  2. The {ECG} signal processing algorithm is in the «learning» state.
urn:iso:std:iso:11073:10101   202834 icon MDC_EVT_STAT_OFF
  1. Device or VMD is in off condition.
  2. Off (e.g. device or VMD is in an off condition)
urn:iso:std:iso:11073:10101   202836 icon MDC_EVT_STAT_STANDBY
  1. Indication: Device In Standby Mode
  2. Indication: the {*} device or subsystem is In standby mode.
urn:iso:std:iso:11073:10101   202838 icon MDC_EVT_STAT_AL_TACHAPNEA_DISABL
  1. Tachyapnea alarm is disabled.
  2. Tachyapnea alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_TACHYPNEA_AIS_ALARM_OFF instead.]
urn:iso:std:iso:11073:10101   202840 icon MDC_EVT_STAT_MODE_TEST

Device or VMD is in test mode.

urn:iso:std:iso:11073:10101   202842 icon MDC_EVT_STAT_WAVE_LEARN
  1. Device or VMD learns waveform for recognition.
  2. {ecgResp} Learning
  3. {ecg or other algorithm} Learning
urn:iso:std:iso:11073:10101   202852 icon MDC_EVT_STAT_DOOR_CLOS
  1. Door in the (sleep measurement) room is closed.
  2. Door in the {sleep measurement} room is closed.
urn:iso:std:iso:11073:10101   202856 icon MDC_EVT_STAT_DEPLET

A sensor, absorber, etc., is depleted.

urn:iso:std:iso:11073:10101   202858 icon MDC_EVT_STAT_NBP_DEFL_AND_MEAS_BP
  1. NIBP is deflating cuff and measuring blood pressure.
  2. Noninvasive blood pressure device is deflating cuff and measuring blood pressure.
urn:iso:std:iso:11073:10101   202860 icon MDC_EVT_STAT_CONN
  1. Connected state of device, sensor, etc.
  2. Connected state of {*} device, sensor, etc.
urn:iso:std:iso:11073:10101   202864 icon MDC_EVT_STAT_DISCONN

Disconnection of a sensor, device, etc.

urn:iso:std:iso:11073:10101   202866 icon MDC_EVT_STAT_SOUND_IN_ROOM_OFF
  1. Sound in the (sleep measurement) room is switched off.
  2. Sound in the {sleep measurement} room is switched off.
urn:iso:std:iso:11073:10101   202868 icon MDC_EVT_STAT_LIGHTS_IN_ROOM_ON
  1. Lights in the (sleep measurement) room are switched on.
  2. Lights in the {sleep measurement} room are switched on.
urn:iso:std:iso:11073:10101   202872 icon MDC_EVT_STAT_SOUND_IN_ROOM_ON
  1. Sound in the (sleep measurement) room is switched on.
  2. Sound in the {sleep measurement} room is switched on.
urn:iso:std:iso:11073:10101   202874 icon MDC_EVT_STAT_ON
  1. Device or VMD is in on condition
  2. On (e.g. device or VMD is in an on condition)
urn:iso:std:iso:11073:10101   202876 icon MDC_EVT_STAT_CO2_WARMING
  1. Carbon dioxide monitor in warm-up mode
  2. The airway CO2 monitor in warm-up mode.
urn:iso:std:iso:11073:10101   202878 icon MDC_EVT_STAT_CO2_AL_DISABL
  1. Carbon dioxide alarm is disabled.
  2. Carbon dioxide alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_CO2_AIS_ALARM_OFF instead.]
urn:iso:std:iso:11073:10101   202880 icon MDC_EVT_STAT_QRS_BEEP_OFF
  1. The beep is off (QRS).
  2. QRS detection auditory information signal is off.
urn:iso:std:iso:11073:10101   202882 icon MDC_EVT_STAT_APNEA_AL_DISABL
  1. Apnea alarm is disabled.
  2. Apnea alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_APNEA_RELATED_AIS_ALARM_OFF instead.]
urn:iso:std:iso:11073:10101   202884 icon MDC_EVT_STAT_DEV_BATT_OPERATED

Device is battery operated.

urn:iso:std:iso:11073:10101   202886 icon MDC_EVT_STAT_DEV
  1. Report of functional status of device
  2. Device (functional) status.
urn:iso:std:iso:11073:10101   202888 icon MDC_EVT_STAT_DEV_MODE_PEDIATRIC

Device is in pediatric mode.

urn:iso:std:iso:11073:10101   202890 icon MDC_EVT_STAT_DEV_MODE_ADULT

Device is in adult mode.

urn:iso:std:iso:11073:10101   202892 icon MDC_EVT_STAT_DEV_MAINS_OPERATED

Device is mains-operated.

urn:iso:std:iso:11073:10101   202894 icon MDC_EVT_STAT_DEV_MODE_COMPUT_CNTRLD

Device, e.g., pump, is in computer-controlled mode.

urn:iso:std:iso:11073:10101   202896 icon MDC_EVT_STAT_POWER_SET_LINE
  1. Device changed to mains-operated
  2. Indication: power supply by line, likely by operator selection.
urn:iso:std:iso:11073:10101   202898 icon MDC_EVT_STAT_POWER_SET_BATT
  1. Device changed to battery operation
  2. Indication: power supply by battery, likely by operator selection.
urn:iso:std:iso:11073:10101   202900 icon MDC_EVT_STAT_CO2_UNCALIB
  1. Carbon dioxide is not calibrated.
  2. The airway CO2 monitor is not calibrated.
urn:iso:std:iso:11073:10101   202902 icon MDC_EVT_STAT_RUNNING
  1. Indication: Device Active/Pump Running
  2. {NBP} Running
urn:iso:std:iso:11073:10101   217184 icon MDC_EVT_STAT_VENT_BREATH_SPONT
  1. Spontaneous breath of the patient, e.g., during weaning
  2. Spontaneous breath of the patient, e.g., during weaning.
urn:iso:std:iso:11073:10101   217188 icon MDC_EVT_STAT_VENT_BREATH_MAND
  1. Machine generated breath of the patient, e.g., during weaning
  2. Machine generated breath of the patient, e.g., during weaning.
urn:iso:std:iso:11073:10101   203266 icon MDC_EVT_ADVIS_CHK
  1. Advisory: Check device or system (NOS)
  2. Check {fresh-gas setting}
urn:iso:std:iso:11073:10101   203268 icon MDC_EVT_ADVIS_CALIB_CHK

Advisory: Check Calibration

urn:iso:std:iso:11073:10101   203270 icon MDC_EVT_ADVIS_CALIB_REQD
  1. Advisory: Calibration required
  2. Advisory: {NBP} calibration required.
urn:iso:std:iso:11073:10101   203272 icon MDC_EVT_ADVIS_CALIB_AND_ZERO_CHK
  1. Advisory: Check Calibration/Zero (system is not sure if calibration data is still ok.)
  2. Advisory: Check Calibration/Zero required
  3. Advisory: Check {invasive blood pressure} calibration/zero (device or system is not sure if calibration data is still ok.).
urn:iso:std:iso:11073:10101   203274 icon MDC_EVT_ADVIS_CONFIG_CHK
  1. Advisory: Check Configuration
  2. Advisory: Check configuration.
urn:iso:std:iso:11073:10101   203276 icon MDC_EVT_ADVIS_SETTINGS_CHK
  1. Advisory: Check Settings
  2. Advisory: Check setting[s].
urn:iso:std:iso:11073:10101   203278 icon MDC_EVT_ADVIS_SETUP_CHK
  1. Advisory: Check Set up
  2. Advisory: Check setup.
urn:iso:std:iso:11073:10101   203280 icon MDC_EVT_ADVIS_SRC_CHK
  1. Advisory: Check Source
  2. Advisory: Check data source or module.
urn:iso:std:iso:11073:10101   203282 icon MDC_EVT_ADVIS_ZERO_CHK
  1. Advisory: Check Zero
  2. Advisory: Check zero, e.g. check {invasive blood pressure} zero.
urn:iso:std:iso:11073:10101   203284 icon MDC_EVT_ADVIS_BATT_COND
  1. Advisory: Condition Battery (battery needs a special ‘condition’ charge cycle for full capacity.)
  2. Advisory: Condition Battery (battery needs a special 'condition' charge cycle for full capacity.).
urn:iso:std:iso:11073:10101   203286 icon MDC_EVT_ADVIS_BATT_REPLACE
  1. Advisory: Replace Battery (a full charge is now a too small fraction of the original capacity or this is not a rechargeable battery that is close to empty.)
  2. Advisory: Replace Battery (a full charge is now a too small fraction of the original capacity, or this is not a rechargeable battery that is close to empty.).
urn:iso:std:iso:11073:10101   203288 icon MDC_EVT_ADVIS_CABLE_CHK
  1. Advisory: Check cable
  2. Advisory: Check cable.
urn:iso:std:iso:11073:10101   203290 icon MDC_EVT_ADVIS_CO2_SENSOR_CHK
  1. Advisory: Check CO sensor
  2. Advisory: Check the airway CO2 sensor.
urn:iso:std:iso:11073:10101   203292 icon MDC_EVT_ADVIS_COMM_CABLE_CHK
  1. Advisory: Check communication cable
  2. Advisory: Check comm cable.
urn:iso:std:iso:11073:10101   203294 icon MDC_EVT_ADVIS_DISPOS_REPLACE
  1. Advisory: Replace disposable
  2. Advisory: Replace disposable.
urn:iso:std:iso:11073:10101   203296 icon MDC_EVT_ADVIS_GAS_AGENT_CHK
  1. Advisory: Check gas agent
  2. Advisory: Check gas agent.
urn:iso:std:iso:11073:10101   203298 icon MDC_EVT_ADVIS_LEAD_CHK
  1. Advisory: Check patient lead or connector
  2. Advisory: Check patient {ECG} leads or connector.
urn:iso:std:iso:11073:10101   203300 icon MDC_EVT_ADVIS_O2_SENSOR_CHK
  1. Advisory: Check O sensor
  2. Advisory: Check O2 sensor.
urn:iso:std:iso:11073:10101   203302 icon MDC_EVT_ADVIS_REC_PAPER_REPLACE
  1. Problem with recording paper subdevice
  2. Problem with recording paper subdevice.
urn:iso:std:iso:11073:10101   203304 icon MDC_EVT_ADVIS_SENSOR_CHK
  1. The sensor must be checked.
  2. Advisory: Check sensor.
  3. {ecgResp} Check sensor
  4. {sensor} Check sensor
urn:iso:std:iso:11073:10101   203306 icon MDC_EVT_ADVIS_STATUS_LOG_CHK
  1. Advisory: Check Log (a fatal system error was entered in a log object and should be read.)
  2. Advisory: Check Log (a fatal system error was entered in a log object and should be read.).
urn:iso:std:iso:11073:10101   203310 icon MDC_EVT_ADVIS_VOL_SENSOR_CHK
  1. Advisory: Check volume sensor
  2. Advisory: Check volume sensor.
urn:iso:std:iso:11073:10101   203312 icon MDC_EVT_ADVIS_GAIN_DECR
  1. Advisory: Decrease Gain (system asks user to decrease the gain; this advisory is different from the overrange error, ErrorEvent, that already is in the nomenclature; it is an "advisory.")
  2. Advisory: Signal voltage out of range; gain adjustment necessary
  3. Advisory: Decrease Gain (system asks user to decrease the gain; this advisory is different from the overrange error, ErrorEvent, that already is in the nomenclature; it is an "advisory.").
urn:iso:std:iso:11073:10101   203314 icon MDC_EVT_ADVIS_GAIN_INCR
  1. Advisory: Signal voltage out of range; gain adjustment necessary
  2. Signal voltage out of range.
urn:iso:std:iso:11073:10101   203316 icon MDC_EVT_ADVIS_TIME_CHK
  1. Advisory: Check time (system asks user to check the time)
  2. Advisory: Check time.
urn:iso:std:iso:11073:10101   203318 icon MDC_EVT_ADVIS_UNIT_CHK
  1. Advisory: Check unit (system asks user to check unit)
  2. Advisory: Check units [of msmt].
urn:iso:std:iso:11073:10101   203320 icon MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_WARN
  1. Advisory: Syringe needs to be replaced soon.
  2. Syringe needs to be replaced soon.
urn:iso:std:iso:11073:10101   203322 icon MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_IMMED

Syringe needs to be replaced immediately.

urn:iso:std:iso:11073:10101   203324 icon MDC_EVT_ADVIS_VENT_WATER_TRAP_CHK
  1. Checking of water trap in a ventilator is necessary.
  2. Advisory: Check water trap in a ventilator.
  3. Check ventilator water trap.
urn:iso:std:iso:11073:10101   203326 icon MDC_EVT_ADVIS_VAPORISER_CHK_DISCONN

Advisory: Vaporizer is not connected, not known or not allowed.

urn:iso:std:iso:11073:10101   203328 icon MDC_EVT_ADVIS_VENT_PRESS_AWAY_CHK
  1. Checking of airway pressure in a ventilator is necessary.
  2. Advisory: Check airway pressure in ventilator.
urn:iso:std:iso:11073:10101   203330 icon MDC_EVT_ADVIS_VENT_FLOW_SENSOR_CHK
  1. Checking of flow sensor in a ventilator is necessary.
  2. Check flow sensor in a ventilator.
urn:iso:std:iso:11073:10101   203332 icon MDC_EVT_ADVIS_VENT_FLOW_CALIB

Flow calibration of ventilator is necessary.

urn:iso:std:iso:11073:10101   203334 icon MDC_EVT_ADVIS_VENT_MIX_IRIS_CALIB
  1. The mixing iris in agent vaporizer in a ventilator must be checked (anesthesia machine).
  2. The mixing iris in agent vaporizer in an ventilator must be checked (anesthesia machine).
urn:iso:std:iso:11073:10101   203336 icon MDC_EVT_ADVIS_VENT_AIR_SUPP_CHK

Checking of ventilator air supply is necessary.

urn:iso:std:iso:11073:10101   203338 icon MDC_EVT_ADVIS_VENT_EXP_VALVE_CHK
  1. Checking of expiration valve is necessary.
  2. Check expiration valve.
  3. Checking of expiratory valve is necessary.
urn:iso:std:iso:11073:10101   258048 icon MDC_EVT_STANDBY_WARN

Warning that device will go to standy

urn:iso:std:iso:11073:10101   203341 icon MDC_EVT_ADVIS_MAINT_NEEDED
  1. Maintenance is required
  2. Maintenance is required (This code is unusual as it applies only to an object.)
  3. A device has identified the need for maintenance (e.g., PM period has expired)
urn:iso:std:iso:11073:10101   197212 icon MDC_EVT_SYRINGE_PATIENT_PRESSURE_HI

IV Fluid pressure is too high on the downstream patient side.

urn:iso:std:iso:11073:10101   197214 icon MDC_EVT_SYRINGE_PLUNGER_POSITION

Plunger out of position

urn:iso:std:iso:11073:10101   197216 icon MDC_EVT_SYRINGE_FLANGE_POSITION

Flange out of position

urn:iso:std:iso:11073:10101   197218 icon MDC_EVT_SYRINGE_BARREL_CAPTURE_FAULT

Syringe barrel capture fault.

urn:iso:std:iso:11073:10101   197220 icon MDC_EVT_SYRINGE_PRESSURE_DISC_POSITION

Pressure disc out of position

urn:iso:std:iso:11073:10101   197222 icon MDC_EVT_SYRINGE_NUT_ENGAGED
urn:iso:std:iso:11073:10101   197224 icon MDC_EVT_SYRINGE_END_OF_TRAVEL

End of plunger travel

urn:iso:std:iso:11073:10101   197226 icon MDC_EVT_SYRINGE_EMPTY

Syringe is empty

urn:iso:std:iso:11073:10101   197228 icon MDC_EVT_SYRINGE_PATIENT_PRESSURE_ALARM
urn:iso:std:iso:11073:10101   197230 icon MDC_EVT_SYRINGE_PLUNGER
urn:iso:std:iso:11073:10101   197232 icon MDC_EVT_SYRINGE_FLANGE
urn:iso:std:iso:11073:10101   197234 icon MDC_EVT_SYRINGE_LEVER
urn:iso:std:iso:11073:10101   197236 icon MDC_EVT_SYRINGE_PRESSURE_DISC
urn:iso:std:iso:11073:10101   197258 icon MDC_EVT_PCA_DOOR_UNLOCKED
  1. Advisory: Patient controlled analgesia: door unlocked
  2. PCA Door is unlocked
urn:iso:std:iso:11073:10101   197260 icon MDC_EVT_PCA_HANDSET_DETACHED
  1. Advisory: Patient controlled analgesia: handset detached
  2. PCA Handset is detached from unit.
urn:iso:std:iso:11073:10101   197262 icon MDC_EVT_PCA_MAX_LIMIT
  1. Advisory: Patient controlled analgesia: maximum limit reached
  2. Maximum PCA dose limit reached
urn:iso:std:iso:11073:10101   197264 icon MDC_EVT_PCA_PAUSED
  1. Advisory: Patient controlled analgesia: paused
  2. PCA paused, reason not specified.
urn:iso:std:iso:11073:10101   197288 icon MDC_EVT_PUMP_DELIV_START

Delivery Start

urn:iso:std:iso:11073:10101   197290 icon MDC_EVT_PUMP_DELIV_STOP

Delivery Stop (or Paused)

urn:iso:std:iso:11073:10101   197292 icon MDC_EVT_PUMP_DELIV_COMP

Delivery Complete

urn:iso:std:iso:11073:10101   197294 icon MDC_EVT_COMM_STATUS_CHANGE
  1. Communication status change
  2. Communication Status Change
urn:iso:std:iso:11073:10101   197296 icon MDC_EVT_PUMP_PROG_CLEARED

Program Cleared

urn:iso:std:iso:11073:10101   197298 icon MDC_EVT_PUMP_AUTO_PROG_CLEARED

Auto-Program Cleared

urn:iso:std:iso:11073:10101   197300 icon MDC_EVT_PATIENT_CHANGE
  1. Advisory: The patient connected to a device has changed
  2. Patient Change
urn:iso:std:iso:11073:10101   197302 icon MDC_EVT_PATIENT_ID_CHANGE
  1. Advisory: The ID of the patient connected to the device has changed
  2. Patient ID Change
urn:iso:std:iso:11073:10101   197304 icon MDC_EVT_PATIENT_WEIGHT_CHANGE
  1. Advisory: The patient weight has changed
  2. Patient Weight Change
urn:iso:std:iso:11073:10101   197328 icon MDC_EVT_IDLE
  1. Idle state of, e.g., device
  2. Idle state of, e.g., {pump} device
urn:iso:std:iso:11073:10101   197330 icon MDC_EVT_CALLBACK
  1. Callback
  2. Callback notififaction to the clinician, e.g. that the secondary infusion has been completed
urn:iso:std:iso:11073:10101   197332 icon MDC_EVT_VOL_INFUS_COMP
  1. Advisory: Infusion of the specified volume has been completed
  2. Infusion complete, where the volume is deternined by the size of the container.
  3. Infusion complete, where the volume is determined by the size of the container.
urn:iso:std:iso:11073:10101   197334 icon MDC_EVT_VOL_INFUS_NEAR_COMP
  1. Advisory: Infusion of the specified volume is nearly complete
  2. Infusion near completion, where the volume us determined by the size of the container.
  3. Infusion near completion, where the volume is determined by the size of the container.
urn:iso:std:iso:11073:10101   197336 icon MDC_EVT_BATT_DEPL
  1. Battery depleted
  2. Depleted Battery
urn:iso:std:iso:11073:10101   197338 icon MDC_EVT_BATT_SERV
  1. Battery service required
  2. Service Battery
urn:iso:std:iso:11073:10101   197340 icon MDC_EVT_EMER_STOP

Emergency Stop

urn:iso:std:iso:11073:10101   197342 icon MDC_EVT_PWR_LOSS
  1. Loss of power supply
  2. Power Loss
urn:iso:std:iso:11073:10101   197344 icon MDC_EVT_FLOW_STOP_OPEN

Flow stop valve is open

urn:iso:std:iso:11073:10101   197346 icon MDC_EVT_CHECK_IV_SET
  1. Advisory: Check Intravenous Set
  2. Check IV set.
urn:iso:std:iso:11073:10101   197348 icon MDC_EVT_UNKNOWN

An unknown event has occurred.

urn:iso:std:iso:11073:10101   197350 icon MDC_EVT_DELAY_IMPOSSIBLE

Programmed start delay will not be reached

urn:iso:std:iso:11073:10101   197352 icon MDC_EVT_PUMP_CHAMBER_BLOCKED

Pump chamber blocked.

urn:iso:std:iso:11073:10101   197354 icon MDC_EVT_HANDSET_DETACHED
  1. Advisory: Handset detached
  2. {*} Handset is detached from unit
urn:iso:std:iso:11073:10101   197306 icon MDC_EVT_PUMP_VOL_COUNTERS_CLEARED

Pump volume counters cleared

urn:iso:std:iso:11073:10101   197308 icon MDC_EVT_DEVICE_TIME_CHANGED

Device time, civil time zone offsett and/or cumulative leap second information has changed

urn:iso:std:iso:11073:10101   197356 icon MDC_EVT_PATIENT_PARAMETER_CHANGE
  1. Any patient parameter has changed, e.g., body mass, height, and/or BSA.
  2. Any patient parameter has changed, e..g. body mass, height and/or BSA.
urn:iso:std:iso:11073:10101   197358 icon MDC_EVT_FLUID_LINE_OCCL_UPSTREAM
  1. Occlusion of upstream fluid line, from pump to IV fluid sources (aka proximal).
  2. Occlusion of upstream fluid line, from pump to IV fluid sources (aka proximal)
urn:iso:std:iso:11073:10101   197360 icon MDC_EVT_FLUID_LINE_OCCL_DOWNSTREAM
  1. Occlusion of downstream fluid line, from pump to patient (aka distal)..
  2. Occlusion of downstream fluid line, from pump to patient (aka distal)
urn:iso:std:iso:11073:10101   197362 icon MDC_EVT_FLUID_LINE_AIR_UPSTREAM
  1. Air in upstream fluid line, from pump to IV fluid sources (aka proximal).
  2. Air in upstream fluid line, from pump to IV fluid sources (aka proximal)
urn:iso:std:iso:11073:10101   197364 icon MDC_EVT_FLUID_LINE_AIR_DOWNSTREAM
  1. Air in downstream fluid line, from pump to patient (aka distal).
  2. Air in downstream fluid line, from pump to patient (aka distal)
urn:iso:std:iso:11073:10101   197376 icon MDC_EVT_DATA_INVALID

Invalid data (for any reason, including missing data)

urn:iso:std:iso:11073:10101   197378 icon MDC_EVT_DATA_MISSING

Missing data (e.g., telemetry data dropouts)

urn:iso:std:iso:11073:10101   203776 icon MDC_EVT_LS_DEVICE
  1. Report of location of a device as item
  2. Report of location of a device as item.
urn:iso:std:iso:11073:10101   203778 icon MDC_EVT_LS_PERSON
  1. Report of location of a person as item
  2. Report of location of a person as item.
urn:iso:std:iso:11073:10101   203780 icon MDC_EVT_LS_MOVEMENT
  1. Report of movement of expected stationary item
  2. Report of movement of expected stationary item.
urn:iso:std:iso:11073:10101   203782 icon MDC_EVT_LS_BOUNDARY
  1. Report of constrained location item exceeding defined boundary
  2. Report of constrained location item exceeding defined boundary.
urn:iso:std:iso:11073:10101   203784 icon MDC_EVT_LS_COLOCATION
  1. Report of item colocation with another item
  2. Report of item colocation with another item.
urn:iso:std:iso:11073:10101   203786 icon MDC_EVT_LS_DWELL
  1. Report of expected moving item dwelling in location longer than a defined period
  2. Report of expected moving item dwelling in location longer than a defined period.
urn:iso:std:iso:11073:10101   203788 icon MDC_EVT_LS_ACCELEROMETER
  1. Report of item acceleration increase potentially due to leaning or falling
  2. Report of item aceleration increase potentially due to leaning or falling.
urn:iso:std:iso:11073:10101   203790 icon MDC_EVT_LS_TAMPER
  1. Report of item tamper interlock being indicated
  2. Report of item tamper interlock being indicated.
urn:iso:std:iso:11073:10101   203792 icon MDC_EVT_LS_INTERACTION
  1. Report of operator interaction with item by button press, cord pull
  2. Report of operator interaction with item by button press, cord pull.
urn:iso:std:iso:11073:10101   203794 icon MDC_EVT_LS_MISSING
  1. Report of loss of communication with item
  2. Report of loss of communication with item.
urn:iso:std:iso:11073:10101   203796 icon MDC_EVT_LS_ENVIRONMENT
  1. Report of item environment of temperature, humidity, pressure, gases
  2. Report of item environment of temperature, humidity, pressure, gases.
urn:iso:std:iso:11073:10101   203798 icon MDC_EVT_LS_BATTERY
  1. Report of item active tag battery status
  2. Report of item active tag battery status.
urn:iso:std:iso:11073:10101   196848 icon MDC_EVT_CUFF_LOOSE

Cuff loose

urn:iso:std:iso:11073:10101   202826 icon MDC_EVT_STAT_AL_PAUSED
  1. Indication: Alarm paused
  2. Alarm is paused (visual and audio indications are off). [This term is deprecated; use MDC_EVT_STAT_AIS_ALARM_PAUSED instead.]
urn:iso:std:iso:11073:10101   197440 icon MDC_EVT_SW_VER_REPORT

An event or report regarding software version and update status

urn:iso:std:iso:11073:10101   197442 icon MDC_EVT_TLS_CERT_EXPIRY

An event or report regarding that the TLS (Transport Layer Security) certificate is about to expire or has expired

urn:iso:std:iso:11073:10101   196609 icon MDC_EVT

Definition for base term 3::0 MDC_EVT is: 1. An event has occurred (NOS) 2. Event (NOS).

urn:iso:std:iso:11073:10101   196611 icon MDC_EVT_ABNORM

Definition for base term 3::2 MDC_EVT_ABNORM is: 1. Abnormal condition detected (NOS) 2. Abnormal condition detected.

urn:iso:std:iso:11073:10101   196613 icon MDC_EVT_ABSENT

Definition for base term 3::4 MDC_EVT_ABSENT is: 1. Absent 2. Absent.

urn:iso:std:iso:11073:10101   196615 icon MDC_EVT_ACTIVE

Definition for base term 3::6 MDC_EVT_ACTIVE is: Active (NOS)

urn:iso:std:iso:11073:10101   203285 icon MDC_EVT_ADVIS_BATT_COND

Definition for base term 3::6676 MDC_EVT_ADVIS_BATT_COND is: 1. Advisory: Condition Battery (battery needs a special ‘condition’ charge cycle for full capacity.) 2. Advisory: Condition Battery (battery needs a special 'condition' charge cycle for full capacity.).

urn:iso:std:iso:11073:10101   203287 icon MDC_EVT_ADVIS_BATT_REPLACE

Definition for base term 3::6678 MDC_EVT_ADVIS_BATT_REPLACE is: 1. Advisory: Replace Battery (a full charge is now a too small fraction of the original capacity or this is not a rechargeable battery that is close to empty.) 2. Advisory: Replace Battery (a full charge is now a too small fraction of the original capacity, or this is not a rechargeable battery that is close to empty.).

urn:iso:std:iso:11073:10101   203289 icon MDC_EVT_ADVIS_CABLE_CHK

Definition for base term 3::6680 MDC_EVT_ADVIS_CABLE_CHK is: 1. Advisory: Check cable 2. Advisory: Check cable.

urn:iso:std:iso:11073:10101   203273 icon MDC_EVT_ADVIS_CALIB_AND_ZERO_CHK

Definition for base term 3::6664 MDC_EVT_ADVIS_CALIB_AND_ZERO_CHK is: 1. Advisory: Check Calibration/Zero (system is not sure if calibration data is still ok.) 2. Advisory: Check Calibration/Zero required 3. Advisory: Check {invasive blood pressure} calibration/zero (device or system is not sure if calibration data is still ok.).

urn:iso:std:iso:11073:10101   203269 icon MDC_EVT_ADVIS_CALIB_CHK

Definition for base term 3::6660 MDC_EVT_ADVIS_CALIB_CHK is: Advisory: Check Calibration

urn:iso:std:iso:11073:10101   203271 icon MDC_EVT_ADVIS_CALIB_REQD

Definition for base term 3::6662 MDC_EVT_ADVIS_CALIB_REQD is: 1. Advisory: Calibration required 2. Advisory: {NBP} calibration required.

urn:iso:std:iso:11073:10101   203267 icon MDC_EVT_ADVIS_CHK

Definition for base term 3::6658 MDC_EVT_ADVIS_CHK is: 1. Advisory: Check device or system (NOS) 2. Check {fresh-gas setting}

urn:iso:std:iso:11073:10101   203291 icon MDC_EVT_ADVIS_CO2_SENSOR_CHK

Definition for base term 3::6682 MDC_EVT_ADVIS_CO2_SENSOR_CHK is: 1. Advisory: Check CO sensor 2. Advisory: Check the airway CO2 sensor.

urn:iso:std:iso:11073:10101   203293 icon MDC_EVT_ADVIS_COMM_CABLE_CHK

Definition for base term 3::6684 MDC_EVT_ADVIS_COMM_CABLE_CHK is: 1. Advisory: Check communication cable 2. Advisory: Check comm cable.

urn:iso:std:iso:11073:10101   203275 icon MDC_EVT_ADVIS_CONFIG_CHK

Definition for base term 3::6666 MDC_EVT_ADVIS_CONFIG_CHK is: 1. Advisory: Check Configuration 2. Advisory: Check configuration.

urn:iso:std:iso:11073:10101   203295 icon MDC_EVT_ADVIS_DISPOS_REPLACE

Definition for base term 3::6686 MDC_EVT_ADVIS_DISPOS_REPLACE is: 1. Advisory: Replace disposable 2. Advisory: Replace disposable.

urn:iso:std:iso:11073:10101   203313 icon MDC_EVT_ADVIS_GAIN_DECR

Definition for base term 3::6704 MDC_EVT_ADVIS_GAIN_DECR is: 1. Advisory: Decrease Gain (system asks user to decrease the gain; this advisory is different from the overrange error, ErrorEvent, that already is in the nomenclature; it is an "advisory.") 2. Advisory: Signal voltage out of range; gain adjustment necessary 3. Advisory: Decrease Gain (system asks user to decrease the gain; this advisory is different from the overrange error, ErrorEvent, that already is in the nomenclature; it is an "advisory.").

urn:iso:std:iso:11073:10101   203315 icon MDC_EVT_ADVIS_GAIN_INCR

Definition for base term 3::6706 MDC_EVT_ADVIS_GAIN_INCR is: 1. Advisory: Signal voltage out of range; gain adjustment necessary 2. Signal voltage out of range.

urn:iso:std:iso:11073:10101   203297 icon MDC_EVT_ADVIS_GAS_AGENT_CHK

Definition for base term 3::6688 MDC_EVT_ADVIS_GAS_AGENT_CHK is: 1. Advisory: Check gas agent 2. Advisory: Check gas agent.

urn:iso:std:iso:11073:10101   203299 icon MDC_EVT_ADVIS_LEAD_CHK

Definition for base term 3::6690 MDC_EVT_ADVIS_LEAD_CHK is: 1. Advisory: Check patient lead or connector 2. Advisory: Check patient {ECG} leads or connector.

urn:iso:std:iso:11073:10101   203301 icon MDC_EVT_ADVIS_O2_SENSOR_CHK

Definition for base term 3::6692 MDC_EVT_ADVIS_O2_SENSOR_CHK is: 1. Advisory: Check O sensor 2. Advisory: Check O2 sensor.

urn:iso:std:iso:11073:10101   203323 icon MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_IMMED

Definition for base term 3::6714 MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_IMMED is: Syringe needs to be replaced immediately.

urn:iso:std:iso:11073:10101   203321 icon MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_WARN

Definition for base term 3::6712 MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_WARN is: 1. Advisory: Syringe needs to be replaced soon. 2. Syringe needs to be replaced soon.

urn:iso:std:iso:11073:10101   203303 icon MDC_EVT_ADVIS_REC_PAPER_REPLACE

Definition for base term 3::6694 MDC_EVT_ADVIS_REC_PAPER_REPLACE is: 1. Problem with recording paper subdevice 2. Problem with recording paper subdevice.

urn:iso:std:iso:11073:10101   203305 icon MDC_EVT_ADVIS_SENSOR_CHK

Definition for base term 3::6696 MDC_EVT_ADVIS_SENSOR_CHK is: 1. The sensor must be checked. 2. Advisory: Check sensor. 3. {ecgResp} Check sensor 4. {sensor} Check sensor

urn:iso:std:iso:11073:10101   203277 icon MDC_EVT_ADVIS_SETTINGS_CHK

Definition for base term 3::6668 MDC_EVT_ADVIS_SETTINGS_CHK is: 1. Advisory: Check Settings 2. Advisory: Check setting[s].

urn:iso:std:iso:11073:10101   203279 icon MDC_EVT_ADVIS_SETUP_CHK

Definition for base term 3::6670 MDC_EVT_ADVIS_SETUP_CHK is: 1. Advisory: Check Set up 2. Advisory: Check setup.

urn:iso:std:iso:11073:10101   203281 icon MDC_EVT_ADVIS_SRC_CHK

Definition for base term 3::6672 MDC_EVT_ADVIS_SRC_CHK is: 1. Advisory: Check Source 2. Advisory: Check data source or module.

urn:iso:std:iso:11073:10101   203307 icon MDC_EVT_ADVIS_STATUS_LOG_CHK

Definition for base term 3::6698 MDC_EVT_ADVIS_STATUS_LOG_CHK is: 1. Advisory: Check Log (a fatal system error was entered in a log object and should be read.) 2. Advisory: Check Log (a fatal system error was entered in a log object and should be read.).

urn:iso:std:iso:11073:10101   203317 icon MDC_EVT_ADVIS_TIME_CHK

Definition for base term 3::6708 MDC_EVT_ADVIS_TIME_CHK is: 1. Advisory: Check time (system asks user to check the time) 2. Advisory: Check time.

urn:iso:std:iso:11073:10101   203319 icon MDC_EVT_ADVIS_UNIT_CHK

Definition for base term 3::6710 MDC_EVT_ADVIS_UNIT_CHK is: 1. Advisory: Check unit (system asks user to check unit) 2. Advisory: Check units [of msmt].

urn:iso:std:iso:11073:10101   203327 icon MDC_EVT_ADVIS_VAPORISER_CHK_DISCONN

Definition for base term 3::6718 MDC_EVT_ADVIS_VAPORISER_CHK_DISCONN is: Advisory: Vaporizer is not connected, not known or not allowed.

urn:iso:std:iso:11073:10101   203337 icon MDC_EVT_ADVIS_VENT_AIR_SUPP_CHK

Definition for base term 3::6728 MDC_EVT_ADVIS_VENT_AIR_SUPP_CHK is: Checking of ventilator air supply is necessary.

urn:iso:std:iso:11073:10101   203339 icon MDC_EVT_ADVIS_VENT_EXP_VALVE_CHK

Definition for base term 3::6730 MDC_EVT_ADVIS_VENT_EXP_VALVE_CHK is: 1. Checking of expiration valve is necessary. 2. Check expiration valve. 3. Checking of expiratory valve is necessary.

urn:iso:std:iso:11073:10101   203333 icon MDC_EVT_ADVIS_VENT_FLOW_CALIB

Definition for base term 3::6724 MDC_EVT_ADVIS_VENT_FLOW_CALIB is: Flow calibration of ventilator is necessary.

urn:iso:std:iso:11073:10101   203331 icon MDC_EVT_ADVIS_VENT_FLOW_SENSOR_CHK

Definition for base term 3::6722 MDC_EVT_ADVIS_VENT_FLOW_SENSOR_CHK is: 1. Checking of flow sensor in a ventilator is necessary. 2. Check flow sensor in a ventilator.

urn:iso:std:iso:11073:10101   203335 icon MDC_EVT_ADVIS_VENT_MIX_IRIS_CALIB

Definition for base term 3::6726 MDC_EVT_ADVIS_VENT_MIX_IRIS_CALIB is: 1. The mixing iris in agent vaporizer in a ventilator must be checked (anesthesia machine). 2. The mixing iris in agent vaporizer in an ventilator must be checked (anesthesia machine).

urn:iso:std:iso:11073:10101   203329 icon MDC_EVT_ADVIS_VENT_PRESS_AWAY_CHK

Definition for base term 3::6720 MDC_EVT_ADVIS_VENT_PRESS_AWAY_CHK is: 1. Checking of airway pressure in a ventilator is necessary. 2. Advisory: Check airway pressure in ventilator.

urn:iso:std:iso:11073:10101   203325 icon MDC_EVT_ADVIS_VENT_WATER_TRAP_CHK

Definition for base term 3::6716 MDC_EVT_ADVIS_VENT_WATER_TRAP_CHK is: 1. Checking of water trap in a ventilator is necessary. 2. Advisory: Check water trap in a ventilator. 3. Check ventilator water trap.

urn:iso:std:iso:11073:10101   203311 icon MDC_EVT_ADVIS_VOL_SENSOR_CHK

Definition for base term 3::6702 MDC_EVT_ADVIS_VOL_SENSOR_CHK is: 1. Advisory: Check volume sensor 2. Advisory: Check volume sensor.

urn:iso:std:iso:11073:10101   203283 icon MDC_EVT_ADVIS_ZERO_CHK

Definition for base term 3::6674 MDC_EVT_ADVIS_ZERO_CHK is: 1. Advisory: Check Zero 2. Advisory: Check zero, e.g. check {invasive blood pressure} zero.

urn:iso:std:iso:11073:10101   197019 icon MDC_EVT_AL_LIMIT

Definition for base term 3::410 MDC_EVT_AL_LIMIT is: 1. Alarm limit exceeded 2. Alarm Limit.

urn:iso:std:iso:11073:10101   196617 icon MDC_EVT_ALARM

Definition for base term 3::8 MDC_EVT_ALARM is: 1. Alarm (NOS) 2. Alarm (NOS).

urn:iso:std:iso:11073:10101   199681 icon MDC_EVT_APNEA

Definition for base term 3::3072 MDC_EVT_APNEA is: 1. No breathing within a pre-configured time span 2. Apnea

urn:iso:std:iso:11073:10101   199915 icon MDC_EVT_BACK_ACTIV_ASYM

Definition for base term 3::3306 MDC_EVT_BACK_ACTIV_ASYM is: Back Activity Asymmetric

urn:iso:std:iso:11073:10101   197337 icon MDC_EVT_BATT_DEPL

Definition for base term 3::728 MDC_EVT_BATT_DEPL is: 1. Battery depleted 2. Depleted Battery

urn:iso:std:iso:11073:10101   196801 icon MDC_EVT_BATT_FAIL

Definition for base term 3::192 MDC_EVT_BATT_FAIL is: 1. Battery failed or is defective 2. {*} Battery inoperable

urn:iso:std:iso:11073:10101   196803 icon MDC_EVT_BATT_LO

Definition for base term 3::194 MDC_EVT_BATT_LO is: 1. Battery discharged or is defective. 2. {ecgResp} Battery low 3. {device or sensor} Battery low

urn:iso:std:iso:11073:10101   196805 icon MDC_EVT_BATT_MALF

Definition for base term 3::196 MDC_EVT_BATT_MALF is: Battery malfunction

urn:iso:std:iso:11073:10101   196807 icon MDC_EVT_BATT_PROB

Definition for base term 3::198 MDC_EVT_BATT_PROB is: Unspecified battery problem

urn:iso:std:iso:11073:10101   197339 icon MDC_EVT_BATT_SERV

Definition for base term 3::730 MDC_EVT_BATT_SERV is: 1. Battery service required 2. Service Battery

urn:iso:std:iso:11073:10101   196745 icon MDC_EVT_BREATH_ABSENT

Definition for base term 3::136 MDC_EVT_BREATH_ABSENT is: 1. Error Event: Breath Absent (this is not apnea, but a technical ventilator event.) 2. Error Event: breath absent (this is not apnea, but a technical ventilator event.).

urn:iso:std:iso:11073:10101   197111 icon MDC_EVT_BUFF_OVERFLOW

Definition for base term 3::502 MDC_EVT_BUFF_OVERFLOW is: 1. Communication timing error: buffer overflow 2. Communication timing error: buffer overflow.

urn:iso:std:iso:11073:10101   196949 icon MDC_EVT_BW_INCORRECT

Definition for base term 3::340 MDC_EVT_BW_INCORRECT is: 1. Bandwidth incorrect 2. Bandwidth incorrect.

urn:iso:std:iso:11073:10101   196813 icon MDC_EVT_CABLE_SHORT

Definition for base term 3::204 MDC_EVT_CABLE_SHORT is: 1. Communication error: cable short 2. {SpO2} Cable failure

urn:iso:std:iso:11073:10101   196747 icon MDC_EVT_CALIB_FAIL

Definition for base term 3::138 MDC_EVT_CALIB_FAIL is: 1. Calibration is not successful. 2. {SpO2} Only Mode (not fully calibrated)

urn:iso:std:iso:11073:10101   197331 icon MDC_EVT_CALLBACK

Definition for base term 3::722 MDC_EVT_CALLBACK is: 1. Callback 2. Callback notififaction to the clinician, e.g. that the secondary infusion has been completed

urn:iso:std:iso:11073:10101   196815 icon MDC_EVT_CATH_PULM_INFLAT_OVER

Definition for base term 3::206 MDC_EVT_CATH_PULM_INFLAT_OVER is: 1. Pulmonary Capillary Wedge Pressure: over inflation 2. {Pulmonary artery catheter} catheter cuff over-inflated.

urn:iso:std:iso:11073:10101   197347 icon MDC_EVT_CHECK_IV_SET

Definition for base term 3::738 MDC_EVT_CHECK_IV_SET is: 1. Advisory: Check Intravenous Set 2. Check IV set.

urn:iso:std:iso:11073:10101   196817 icon MDC_EVT_CKT_SHORT

Definition for base term 3::208 MDC_EVT_CKT_SHORT is: A short circuit was detected in a VMD.

urn:iso:std:iso:11073:10101   196821 icon MDC_EVT_CO2_CAN_LEAK

Definition for base term 3::212 MDC_EVT_CO2_CAN_LEAK is: 1. CO2 Canister leak 2. CO2 canister leak.

urn:iso:std:iso:11073:10101   197071 icon MDC_EVT_CO2_MSMT_FAIL

Definition for base term 3::462 MDC_EVT_CO2_MSMT_FAIL is: 1. Failure occurred in a CO2 measuring device. 2. A failure occurred in the airway CO2 measuring device.

urn:iso:std:iso:11073:10101   196823 icon MDC_EVT_CO2_SAMPL_LINE_DEFECT

Definition for base term 3::214 MDC_EVT_CO2_SAMPL_LINE_DEFECT is: Defect occurred in a CO2 sample line

urn:iso:std:iso:11073:10101   197073 icon MDC_EVT_CO2_SENSOR_FAIL

Definition for base term 3::464 MDC_EVT_CO2_SENSOR_FAIL is: 1. Fault occurred in carbon dioxide sensor disc. 2. A fault occurred in the airway CO2 sensor.

urn:iso:std:iso:11073:10101   196825 icon MDC_EVT_CO2_WIND_OBSTRUC

Definition for base term 3::216 MDC_EVT_CO2_WIND_OBSTRUC is: 1. Carbon dioxide measurement window in a CO2 measuring device is occluded. 2. The airway CO2 sensor window is occluded.

urn:iso:std:iso:11073:10101   197077 icon MDC_EVT_COMM

Definition for base term 3::468 MDC_EVT_COMM is: 1. Communication error: NOS 2. Unspecified communication event.

urn:iso:std:iso:11073:10101   196827 icon MDC_EVT_COMM_LINK_NOISY

Definition for base term 3::218 MDC_EVT_COMM_LINK_NOISY is: 1. Error Event: Communication Link Noisy 2. Comm link noisy.

urn:iso:std:iso:11073:10101   196749 icon MDC_EVT_COMM_LOST

Definition for base term 3::140 MDC_EVT_COMM_LOST is: 1. Error Event: Communication Lost 2. {Monitor} No communications

urn:iso:std:iso:11073:10101   196829 icon MDC_EVT_COMM_MODULE_ERR

Definition for base term 3::220 MDC_EVT_COMM_MODULE_ERR is: 1. Error Event: Communication Module Error 2. Communication module error.

urn:iso:std:iso:11073:10101   197295 icon MDC_EVT_COMM_STATUS_CHANGE

Definition for base term 3::686 MDC_EVT_COMM_STATUS_CHANGE is: 1. Communication status change 2. Communication Status Change

urn:iso:std:iso:11073:10101   196831 icon MDC_EVT_COMPONENT_POSN_PROB

Definition for base term 3::222 MDC_EVT_COMPONENT_POSN_PROB is: 1. Supply or disposable positioning problem 2. Supply or disposable positioning problem.

urn:iso:std:iso:11073:10101   197027 icon MDC_EVT_COMPUT_UNDERFLOW

Definition for base term 3::418 MDC_EVT_COMPUT_UNDERFLOW is: Underflow was detected in a measurement or calculation.

urn:iso:std:iso:11073:10101   196751 icon MDC_EVT_CONFIG_ERR

Definition for base term 3::142 MDC_EVT_CONFIG_ERR is: 1. Device configuration: combination is not valid. 2. {SpO2} Connection not supported

urn:iso:std:iso:11073:10101   196621 icon MDC_EVT_CONN

Definition for base term 3::12 MDC_EVT_CONN is: Connection

urn:iso:std:iso:11073:10101   196833 icon MDC_EVT_CONNECTOR_SHORT

Definition for base term 3::224 MDC_EVT_CONNECTOR_SHORT is: 1. Connection short 2. Connector short.

urn:iso:std:iso:11073:10101   196623 icon MDC_EVT_CONTAM

Definition for base term 3::14 MDC_EVT_CONTAM is: Contaminated

urn:iso:std:iso:11073:10101   196835 icon MDC_EVT_CUFF_INCORRECT

Definition for base term 3::226 MDC_EVT_CUFF_INCORRECT is: 1. Incorrect Cuff 2. Incorrect NIBP cuff type

urn:iso:std:iso:11073:10101   196841 icon MDC_EVT_CUFF_INFLAT_OVER

Definition for base term 3::232 MDC_EVT_CUFF_INFLAT_OVER is: 1. Cuff over inflated 2. {NBP} cuff over-inflated, i.e. cuff pressure high.

urn:iso:std:iso:11073:10101   196837 icon MDC_EVT_CUFF_LEAK

Definition for base term 3::228 MDC_EVT_CUFF_LEAK is: Cuff leak

urn:iso:std:iso:11073:10101   196849 icon MDC_EVT_CUFF_LOOSE

Definition for base term 3::240 MDC_EVT_CUFF_LOOSE is: Cuff loose

urn:iso:std:iso:11073:10101   196839 icon MDC_EVT_CUFF_NOT_DEFLATED

Definition for base term 3::230 MDC_EVT_CUFF_NOT_DEFLATED is: 1. Cuff not fully deflated 2. {NBP} cuff not deflated.

urn:iso:std:iso:11073:10101   197039 icon MDC_EVT_CUFF_POSN_ERR

Definition for base term 3::430 MDC_EVT_CUFF_POSN_ERR is: 1. Cuff improperly placed 2. {NBP} cuff has not been positioned correctly.

urn:iso:std:iso:11073:10101   197091 icon MDC_EVT_DATA_ACQN_ERR

Definition for base term 3::482 MDC_EVT_DATA_ACQN_ERR is: 1. Unspecified problem in data acquisition 2. Unspecified problem in data acquisition.

urn:iso:std:iso:11073:10101   196753 icon MDC_EVT_DATA_ACQN_PROB

Definition for base term 3::144 MDC_EVT_DATA_ACQN_PROB is: Unspecified problem in data acquisition

urn:iso:std:iso:11073:10101   197377 icon MDC_EVT_DATA_INVALID

Definition for base term 3::768 MDC_EVT_DATA_INVALID is: Invalid data (for any reason, including missing data)

urn:iso:std:iso:11073:10101   197379 icon MDC_EVT_DATA_MISSING

Definition for base term 3::770 MDC_EVT_DATA_MISSING is: Missing data (e.g., telemetry data dropouts)

urn:iso:std:iso:11073:10101   196625 icon MDC_EVT_DEFECT

Definition for base term 3::16 MDC_EVT_DEFECT is: Defect is detected in a device, sensor, etc.

urn:iso:std:iso:11073:10101   196627 icon MDC_EVT_DEPLET

Definition for base term 3::18 MDC_EVT_DEPLET is: An agent is detected as depleted in a device, sensor, etc

urn:iso:std:iso:11073:10101   199855 icon MDC_EVT_DESAT

Definition for base term 3::3246 MDC_EVT_DESAT is: 1. Limit Event: Desaturation (escalated low oxygen alarm, used esp. in neonatal) 2. SpO2 Desaturation

urn:iso:std:iso:11073:10101   196629 icon MDC_EVT_DETEC

Definition for base term 3::20 MDC_EVT_DETEC is: Some signal or special condition was detected.

urn:iso:std:iso:11073:10101   197135 icon MDC_EVT_DEV_STAT_RPT

Definition for base term 3::526 MDC_EVT_DEV_STAT_RPT is: Device status report.

urn:iso:std:iso:11073:10101   196631 icon MDC_EVT_DISCONN

Definition for base term 3::22 MDC_EVT_DISCONN is: 1. Disconnection, e.g., in sampling line 2. Disconnection, e.g., in sampling line.

urn:iso:std:iso:11073:10101   197197 icon MDC_EVT_DISPOS_LO

Definition for base term 3::588 MDC_EVT_DISPOS_LO is: 1. Disposables low or out 2. Disposables low or out.

urn:iso:std:iso:11073:10101   196633 icon MDC_EVT_DISTURB

Definition for base term 3::24 MDC_EVT_DISTURB is: 1. Signal is disturbed. 2. {Airway gas concentration} signal is disturbed.

urn:iso:std:iso:11073:10101   196843 icon MDC_EVT_DOOR_OR_HANDLE_POSN_PROB

Definition for base term 3::234 MDC_EVT_DOOR_OR_HANDLE_POSN_PROB is: A door or handle which must be closed for proper operation is open.

urn:iso:std:iso:11073:10101   197085 icon MDC_EVT_DOOR_POSN_ERR

Definition for base term 3::476 MDC_EVT_DOOR_POSN_ERR is: 1. A door or handle, which must be closed for operation, is open. 2. Door Open

urn:iso:std:iso:11073:10101   199875 icon MDC_EVT_ECG_ARRHY

Definition for base term 3::3266 MDC_EVT_ECG_ARRHY is: Unspecified ECG (arrhythmia) event

urn:iso:std:iso:11073:10101   199685 icon MDC_EVT_ECG_ASYSTOLE

Definition for base term 3::3076 MDC_EVT_ECG_ASYSTOLE is: No QRS-complex found in predefined time period

urn:iso:std:iso:11073:10101   199737 icon MDC_EVT_ECG_ATR_FIB

Definition for base term 3::3128 MDC_EVT_ECG_ATR_FIB is: Atrial fibrillation

urn:iso:std:iso:11073:10101   199885 icon MDC_EVT_ECG_ATR_FLUT

Definition for base term 3::3276 MDC_EVT_ECG_ATR_FLUT is: Atrial flutter

urn:iso:std:iso:11073:10101   199739 icon MDC_EVT_ECG_ATR_P_C

Definition for base term 3::3130 MDC_EVT_ECG_ATR_P_C is: Premature atrial contraction

urn:iso:std:iso:11073:10101   199741 icon MDC_EVT_ECG_ATR_PACING

Definition for base term 3::3132 MDC_EVT_ECG_ATR_PACING is: 1. Atrial Pacing 2. Atrial Pacing.

urn:iso:std:iso:11073:10101   199743 icon MDC_EVT_ECG_ATR_STAND

Definition for base term 3::3134 MDC_EVT_ECG_ATR_STAND is: 1. Atrial standstill 2. Atrial Standstill.

urn:iso:std:iso:11073:10101   199745 icon MDC_EVT_ECG_ATR_TACHY

Definition for base term 3::3136 MDC_EVT_ECG_ATR_TACHY is: Atrial tachycardia

urn:iso:std:iso:11073:10101   199747 icon MDC_EVT_ECG_ATR_TACHY_MULTIFOCAL

Definition for base term 3::3138 MDC_EVT_ECG_ATR_TACHY_MULTIFOCAL is: 1. Atrial tachycardia multifocal 2. Atrial Tachycardia Multifocal

urn:iso:std:iso:11073:10101   199749 icon MDC_EVT_ECG_ATR_TACHY_PAROX

Definition for base term 3::3140 MDC_EVT_ECG_ATR_TACHY_PAROX is: 1. Atrial tachycardia paroxysmal 2. Atrial Tachycardia Paroxysmal

urn:iso:std:iso:11073:10101   199751 icon MDC_EVT_ECG_AV_DISSOC

Definition for base term 3::3142 MDC_EVT_ECG_AV_DISSOC is: 1. AV Disassociation 2. AV Dissociation

urn:iso:std:iso:11073:10101   199755 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_1

Definition for base term 3::3146 MDC_EVT_ECG_AV_HEART_BLK_DEG_1 is: 1. AV block 1°. 2. AV block 1°

urn:iso:std:iso:11073:10101   199757 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2

Definition for base term 3::3148 MDC_EVT_ECG_AV_HEART_BLK_DEG_2 is: 1. AV block 2°. 2. AV block 2°

urn:iso:std:iso:11073:10101   199889 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2_1

Definition for base term 3::3280 MDC_EVT_ECG_AV_HEART_BLK_DEG_2_1 is: 2:1 AV block

urn:iso:std:iso:11073:10101   199759 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_I

Definition for base term 3::3150 MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_I is: 1. AV block 2, Type I 2. AV Heart Block Degree 2 Type I

urn:iso:std:iso:11073:10101   199761 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_II

Definition for base term 3::3152 MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_II is: 1. AV block 2, Type II 2. AV Heart Block Degree 2 Type II

urn:iso:std:iso:11073:10101   199867 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_3

Definition for base term 3::3258 MDC_EVT_ECG_AV_HEART_BLK_DEG_3 is: 1. AV block 3°. 2. AV block 3°

urn:iso:std:iso:11073:10101   199891 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_3_1

Definition for base term 3::3282 MDC_EVT_ECG_AV_HEART_BLK_DEG_3_1 is: 3:1 AV block

urn:iso:std:iso:11073:10101   199897 icon MDC_EVT_ECG_AV_HEART_BLK_DEG_4_1

Definition for base term 3::3288 MDC_EVT_ECG_AV_HEART_BLK_DEG_4_1 is: 4:1 AV block

urn:iso:std:iso:11073:10101   199753 icon MDC_EVT_ECG_AV_PACING_SEQ

Definition for base term 3::3144 MDC_EVT_ECG_AV_PACING_SEQ is: AV Pacing Sequential

urn:iso:std:iso:11073:10101   199763 icon MDC_EVT_ECG_BB_BLK

Definition for base term 3::3154 MDC_EVT_ECG_BB_BLK is: 1. Bundle Branch block 2. Bundle Branch Block

urn:iso:std:iso:11073:10101   199687 icon MDC_EVT_ECG_BEAT_MISSED

Definition for base term 3::3078 MDC_EVT_ECG_BEAT_MISSED is: Missed beat within some regular ECG rhythm

urn:iso:std:iso:11073:10101   199689 icon MDC_EVT_ECG_BEAT_UNUSUAL

Definition for base term 3::3080 MDC_EVT_ECG_BEAT_UNUSUAL is: 1. Unusual beat within some regular ECG rhythm 2. Unusual beat

urn:iso:std:iso:11073:10101   199691 icon MDC_EVT_ECG_BIGEM

Definition for base term 3::3082 MDC_EVT_ECG_BIGEM is: 1. Ventricular bigemini: a specific rhythm 2. Ventricular bigeminy 3. Ventricular bigeminy: a specific rhythm

urn:iso:std:iso:11073:10101   199695 icon MDC_EVT_ECG_BRADY_EXTREME

Definition for base term 3::3086 MDC_EVT_ECG_BRADY_EXTREME is: Limit Event: Extreme Bradycardia (escalated low HR limit, not a brady rhythm)

urn:iso:std:iso:11073:10101   199697 icon MDC_EVT_ECG_BRADY_SUST

Definition for base term 3::3088 MDC_EVT_ECG_BRADY_SUST is: 1. Sustained Bradycardia 2. Sustained bradycardia.

urn:iso:std:iso:11073:10101   199771 icon MDC_EVT_ECG_CARD_BEAT

Definition for base term 3::3162 MDC_EVT_ECG_CARD_BEAT is: 1. Heartbeat 2. [Heart] Beat

urn:iso:std:iso:11073:10101   199765 icon MDC_EVT_ECG_CARD_BEAT_RATE_HI

Definition for base term 3::3156 MDC_EVT_ECG_CARD_BEAT_RATE_HI is: 1. High heart rate 2. High Heart Rate

urn:iso:std:iso:11073:10101   199767 icon MDC_EVT_ECG_CARD_BEAT_RATE_IRREG

Definition for base term 3::3158 MDC_EVT_ECG_CARD_BEAT_RATE_IRREG is: Error Event: Irregular heart rate (which means the beat detector finds a highly variable heart rate and cannot derive a consistent/stable value)

urn:iso:std:iso:11073:10101   199769 icon MDC_EVT_ECG_CARD_BEAT_RATE_LO

Definition for base term 3::3160 MDC_EVT_ECG_CARD_BEAT_RATE_LO is: 1. Low heart rate 2. Low Heart Rate

urn:iso:std:iso:11073:10101   199701 icon MDC_EVT_ECG_FIB

Definition for base term 3::3092 MDC_EVT_ECG_FIB is: 1. Fibrillation (non-specific) 2. Fibrillation

urn:iso:std:iso:11073:10101   199775 icon MDC_EVT_ECG_HEART_BLK

Definition for base term 3::3166 MDC_EVT_ECG_HEART_BLK is: 1. Heart block 2. Heart Block

urn:iso:std:iso:11073:10101   199777 icon MDC_EVT_ECG_HEART_BLK_COMP

Definition for base term 3::3168 MDC_EVT_ECG_HEART_BLK_COMP is: 1. Complete Heart block 2. Heart Block Complete

urn:iso:std:iso:11073:10101   199773 icon MDC_EVT_ECG_HEART_DYING

Definition for base term 3::3164 MDC_EVT_ECG_HEART_DYING is: 1. Dying heart 2. Dying Heart

urn:iso:std:iso:11073:10101   199907 icon MDC_EVT_ECG_JUNC_ESC_BEATS

Definition for base term 3::3298 MDC_EVT_ECG_JUNC_ESC_BEATS is: 1. Junctional escape beats 2. Junctional Escape Beats.

urn:iso:std:iso:11073:10101   199779 icon MDC_EVT_ECG_JUNC_P_C

Definition for base term 3::3170 MDC_EVT_ECG_JUNC_P_C is: 1. Junctional premature contraction 2. Premature Contraction, Junctional

urn:iso:std:iso:11073:10101   199869 icon MDC_EVT_ECG_JUNC_RHY

Definition for base term 3::3260 MDC_EVT_ECG_JUNC_RHY is: Junctional rhythm

urn:iso:std:iso:11073:10101   199781 icon MDC_EVT_ECG_JUNC_TACHY

Definition for base term 3::3172 MDC_EVT_ECG_JUNC_TACHY is: Junctional tachycardia

urn:iso:std:iso:11073:10101   199783 icon MDC_EVT_ECG_JUNC_TACHY_PAROX

Definition for base term 3::3174 MDC_EVT_ECG_JUNC_TACHY_PAROX is: 1. Paroxysmal Junctional tachycardia 2. Paroxysmal supraventricular tachycardia

urn:iso:std:iso:11073:10101   199909 icon MDC_EVT_ECG_JUNC_TACHY_RUN

Definition for base term 3::3300 MDC_EVT_ECG_JUNC_TACHY_RUN is: Run of junctional tachycardia

urn:iso:std:iso:11073:10101   199785 icon MDC_EVT_ECG_LA_FASC_BLK

Definition for base term 3::3176 MDC_EVT_ECG_LA_FASC_BLK is: 1. Left Anterior Fascicular Block 2. Fascicular Block. LA.

urn:iso:std:iso:11073:10101   199787 icon MDC_EVT_ECG_LBB_BLK

Definition for base term 3::3178 MDC_EVT_ECG_LBB_BLK is: 1. Left Bundle Branch block 2. Left Bundle Branch Block

urn:iso:std:iso:11073:10101   199789 icon MDC_EVT_ECG_LP_FASC_BLK

Definition for base term 3::3180 MDC_EVT_ECG_LP_FASC_BLK is: 1. Left Posterior Fascicular Block 2. Fascicular Block. LP

urn:iso:std:iso:11073:10101   199703 icon MDC_EVT_ECG_NO_ECT_BEAT

Definition for base term 3::3094 MDC_EVT_ECG_NO_ECT_BEAT is: 1. No Ectopic beat 2. No ectopic beat

urn:iso:std:iso:11073:10101   199683 icon MDC_EVT_ECG_NOT_PACED

Definition for base term 3::3074 MDC_EVT_ECG_NOT_PACED is: 1. Beat not paced 2. No pacer detected

urn:iso:std:iso:11073:10101   199705 icon MDC_EVT_ECG_PACED_BEAT

Definition for base term 3::3096 MDC_EVT_ECG_PACED_BEAT is: Pacer pulse sensed by heart

urn:iso:std:iso:11073:10101   199895 icon MDC_EVT_ECG_PACER_ABSENT

Definition for base term 3::3286 MDC_EVT_ECG_PACER_ABSENT is: No pacer detected

urn:iso:std:iso:11073:10101   199903 icon MDC_EVT_ECG_PACER_ARTIF_RECOG

Definition for base term 3::3294 MDC_EVT_ECG_PACER_ARTIF_RECOG is: Pacer artifact recognized

urn:iso:std:iso:11073:10101   199791 icon MDC_EVT_ECG_PACER_NOT_PACING

Definition for base term 3::3182 MDC_EVT_ECG_PACER_NOT_PACING is: Pacer (device) not sensing

urn:iso:std:iso:11073:10101   199709 icon MDC_EVT_ECG_PACING_CAPT

Definition for base term 3::3100 MDC_EVT_ECG_PACING_CAPT is: 1. Pacing captured (recognized by heart) 2. Pacing capture

urn:iso:std:iso:11073:10101   199711 icon MDC_EVT_ECG_PACING_NON_CAPT

Definition for base term 3::3102 MDC_EVT_ECG_PACING_NON_CAPT is: 1. Pacer not captured (not recognized by heart) 2. Pacing not captured (not recognized by heart)

urn:iso:std:iso:11073:10101   199713 icon MDC_EVT_ECG_PACING_RUN

Definition for base term 3::3104 MDC_EVT_ECG_PACING_RUN is: 1. Run of paced beats 2. Pacing Run

urn:iso:std:iso:11073:10101   199715 icon MDC_EVT_ECG_PATT

Definition for base term 3::3106 MDC_EVT_ECG_PATT is: Unspecified ECG (arrhythmia) event

urn:iso:std:iso:11073:10101   199717 icon MDC_EVT_ECG_PAUSE

Definition for base term 3::3108 MDC_EVT_ECG_PAUSE is: 1. Prolonged RR interval, due to any reason 2. Pause

urn:iso:std:iso:11073:10101   199793 icon MDC_EVT_ECG_PT_NOT_PACED

Definition for base term 3::3184 MDC_EVT_ECG_PT_NOT_PACED is: 1. Patient not paced 2. Patient Not Paced

urn:iso:std:iso:11073:10101   199719 icon MDC_EVT_ECG_QUADRIGEM

Definition for base term 3::3110 MDC_EVT_ECG_QUADRIGEM is: Quadrigeminy

urn:iso:std:iso:11073:10101   199795 icon MDC_EVT_ECG_RBB_BLK

Definition for base term 3::3186 MDC_EVT_ECG_RBB_BLK is: 1. Right Bundle Branch block 2. Right Bundle Branch Block

urn:iso:std:iso:11073:10101   199721 icon MDC_EVT_ECG_RHY

Definition for base term 3::3112 MDC_EVT_ECG_RHY is: Rhythm

urn:iso:std:iso:11073:10101   199723 icon MDC_EVT_ECG_RHY_ABSENT

Definition for base term 3::3114 MDC_EVT_ECG_RHY_ABSENT is: No [cardiac] rhythm

urn:iso:std:iso:11073:10101   199881 icon MDC_EVT_ECG_RHY_CPLT

Definition for base term 3::3272 MDC_EVT_ECG_RHY_CPLT is: Couplet

urn:iso:std:iso:11073:10101   199725 icon MDC_EVT_ECG_RHY_ECT

Definition for base term 3::3116 MDC_EVT_ECG_RHY_ECT is: Ectopic rhythm

urn:iso:std:iso:11073:10101   199727 icon MDC_EVT_ECG_RR_IRREG

Definition for base term 3::3118 MDC_EVT_ECG_RR_IRREG is: Irregular rhythm

urn:iso:std:iso:11073:10101   199693 icon MDC_EVT_ECG_SINUS_BRADY

Definition for base term 3::3084 MDC_EVT_ECG_SINUS_BRADY is: 1. Bradycardia 2. Sinus bradycardia

urn:iso:std:iso:11073:10101   199871 icon MDC_EVT_ECG_SINUS_TACHY

Definition for base term 3::3262 MDC_EVT_ECG_SINUS_TACHY is: Sinus tachycardia

urn:iso:std:iso:11073:10101   199849 icon MDC_EVT_ECG_STAT_ECT

Definition for base term 3::3240 MDC_EVT_ECG_STAT_ECT is: 1. Current ectopic rhythm status: conveys an enumerated summary of the predominant ECG ectopic rhythm type(s) over the reporting time interval 2. Present ectopic arrhythmia type; "present" implies user-defined time-constant (e.g. within last minute).

urn:iso:std:iso:11073:10101   199851 icon MDC_EVT_ECG_STAT_RHY

Definition for base term 3::3242 MDC_EVT_ECG_STAT_RHY is: 1. Current rhythm status: conveys an enumerated summary of the predominant ECG rhythm type(s) over the reporting time interval 2. Present rhythm; "present" implies user-defined time-constant (e.g. within last minute)

urn:iso:std:iso:11073:10101   199797 icon MDC_EVT_ECG_SV_BEAT

Definition for base term 3::3188 MDC_EVT_ECG_SV_BEAT is: 1. Supraventricular beat 2. SV Beat

urn:iso:std:iso:11073:10101   199799 icon MDC_EVT_ECG_SV_P_C

Definition for base term 3::3190 MDC_EVT_ECG_SV_P_C is: Supraventricular extrasystole

urn:iso:std:iso:11073:10101   199899 icon MDC_EVT_ECG_SV_P_C_FREQ

Definition for base term 3::3290 MDC_EVT_ECG_SV_P_C_FREQ is: Frequent supraventricular extrasystoles

urn:iso:std:iso:11073:10101   199857 icon MDC_EVT_ECG_SV_P_C_RUN

Definition for base term 3::3248 MDC_EVT_ECG_SV_P_C_RUN is: Several consecutive supraventricular extrasystoles

urn:iso:std:iso:11073:10101   199801 icon MDC_EVT_ECG_SV_TACHY

Definition for base term 3::3192 MDC_EVT_ECG_SV_TACHY is: Supraventricular tachycardia

urn:iso:std:iso:11073:10101   199729 icon MDC_EVT_ECG_TACHY

Definition for base term 3::3120 MDC_EVT_ECG_TACHY is: Tachycardia

urn:iso:std:iso:11073:10101   199731 icon MDC_EVT_ECG_TACHY_EXTREME

Definition for base term 3::3122 MDC_EVT_ECG_TACHY_EXTREME is: Limit Event: Extreme Tachycardia (escalated high HR limit, not a tachy rhythm)

urn:iso:std:iso:11073:10101   199733 icon MDC_EVT_ECG_TACHY_UNSPEC

Definition for base term 3::3124 MDC_EVT_ECG_TACHY_UNSPEC is: 1. Tacycardia (unspecified) 2. Tachycardia Unspecified

urn:iso:std:iso:11073:10101   199735 icon MDC_EVT_ECG_TRIGEM

Definition for base term 3::3126 MDC_EVT_ECG_TRIGEM is: 1. Ventricular trigeminy 2. Trigeminy

urn:iso:std:iso:11073:10101   199805 icon MDC_EVT_ECG_V_BIGEM

Definition for base term 3::3196 MDC_EVT_ECG_V_BIGEM is: 1. Ventricular bigeminy 2. Ventriclular bigeminy

urn:iso:std:iso:11073:10101   199807 icon MDC_EVT_ECG_V_FIB

Definition for base term 3::3198 MDC_EVT_ECG_V_FIB is: Ventricular fibrillation

urn:iso:std:iso:11073:10101   199811 icon MDC_EVT_ECG_V_FLUT

Definition for base term 3::3202 MDC_EVT_ECG_V_FLUT is: Ventricular flutter

urn:iso:std:iso:11073:10101   199813 icon MDC_EVT_ECG_V_P_C

Definition for base term 3::3204 MDC_EVT_ECG_V_P_C is: Premature ventricular contraction

urn:iso:std:iso:11073:10101   199883 icon MDC_EVT_ECG_V_P_C_FREQ

Definition for base term 3::3274 MDC_EVT_ECG_V_P_C_FREQ is: Frequent premature ventricular contractions

urn:iso:std:iso:11073:10101   199817 icon MDC_EVT_ECG_V_P_C_MULTIFORM

Definition for base term 3::3208 MDC_EVT_ECG_V_P_C_MULTIFORM is: Multiformed premature ventricular contractions

urn:iso:std:iso:11073:10101   199819 icon MDC_EVT_ECG_V_P_C_PAIR

Definition for base term 3::3210 MDC_EVT_ECG_V_P_C_PAIR is: Pair of premature ventricular contractions

urn:iso:std:iso:11073:10101   199861 icon MDC_EVT_ECG_V_P_C_RATE

Definition for base term 3::3252 MDC_EVT_ECG_V_P_C_RATE is: A specific limit alert on the PVC rate

urn:iso:std:iso:11073:10101   199815 icon MDC_EVT_ECG_V_P_C_RonT

Definition for base term 3::3206 MDC_EVT_ECG_V_P_C_RonT is: Premature ventricular contraction, R-on-T

urn:iso:std:iso:11073:10101   199821 icon MDC_EVT_ECG_V_P_C_RUN

Definition for base term 3::3212 MDC_EVT_ECG_V_P_C_RUN is: Several consecutive ventricular extrasystoles

urn:iso:std:iso:11073:10101   199823 icon MDC_EVT_ECG_V_P_C_TRIP

Definition for base term 3::3214 MDC_EVT_ECG_V_P_C_TRIP is: VPC Triplet

urn:iso:std:iso:11073:10101   199825 icon MDC_EVT_ECG_V_PACING

Definition for base term 3::3216 MDC_EVT_ECG_V_PACING is: 1. Ventricular Pacing 2. Ventricular pacing

urn:iso:std:iso:11073:10101   199803 icon MDC_EVT_ECG_V_PARASYS

Definition for base term 3::3194 MDC_EVT_ECG_V_PARASYS is: Ventricular parasystole

urn:iso:std:iso:11073:10101   199827 icon MDC_EVT_ECG_V_QUADRIGEM

Definition for base term 3::3218 MDC_EVT_ECG_V_QUADRIGEM is: 1. Ventricular quadrigeminy 2. Ventricular Quadrigeminy

urn:iso:std:iso:11073:10101   199829 icon MDC_EVT_ECG_V_RHY

Definition for base term 3::3220 MDC_EVT_ECG_V_RHY is: Ventricular rhythm: escalation of Run of PVC, not yet flutter

urn:iso:std:iso:11073:10101   199831 icon MDC_EVT_ECG_V_STAND

Definition for base term 3::3222 MDC_EVT_ECG_V_STAND is: 1. Ventricular standstill 2. Ventricular Standstill

urn:iso:std:iso:11073:10101   199833 icon MDC_EVT_ECG_V_TACHY

Definition for base term 3::3224 MDC_EVT_ECG_V_TACHY is: Ventricular tachycardia

urn:iso:std:iso:11073:10101   199835 icon MDC_EVT_ECG_V_TACHY_NON_SUST

Definition for base term 3::3226 MDC_EVT_ECG_V_TACHY_NON_SUST is: 1. Ventricular tachycardia, Non-sustained 2. Ventricular Tachycardia, Non-sustained

urn:iso:std:iso:11073:10101   199841 icon MDC_EVT_ECG_V_TACHY_RHY

Definition for base term 3::3232 MDC_EVT_ECG_V_TACHY_RHY is: 1. Ventricular tachycardia Rhythm 2. Ventricular Tachycardia Rhythm

urn:iso:std:iso:11073:10101   199843 icon MDC_EVT_ECG_V_TACHY_RHY_SUST

Definition for base term 3::3234 MDC_EVT_ECG_V_TACHY_RHY_SUST is: 1. Ventricular tachycardia Rhythm, Sustained 2. Vent Tachycardia Rhythm, Sustained

urn:iso:std:iso:11073:10101   199837 icon MDC_EVT_ECG_V_TACHY_SUST

Definition for base term 3::3228 MDC_EVT_ECG_V_TACHY_SUST is: 1. Ventricular tachycardia, Sustained 2. Ventricular Tachycardia, Sustained

urn:iso:std:iso:11073:10101   199839 icon MDC_EVT_ECG_V_TACHY_TORSADE

Definition for base term 3::3230 MDC_EVT_ECG_V_TACHY_TORSADE is: 1. Ventricular tachycardia, Torsades de Pointes 2. Torsades de Pointes

urn:iso:std:iso:11073:10101   199845 icon MDC_EVT_ECG_V_TRIGEM

Definition for base term 3::3236 MDC_EVT_ECG_V_TRIGEM is: 1. Ventricular trigemini: a specific rhythm 2. Ventricular trigeminy 3. Ventricular trigeminy: a specific rhythm

urn:iso:std:iso:11073:10101   199847 icon MDC_EVT_ECG_V_TRIGEM_RHY

Definition for base term 3::3238 MDC_EVT_ECG_V_TRIGEM_RHY is: 1. Ventricular trigeminy rhythm 2. Ventricular Trigeminy Rhythm

urn:iso:std:iso:11073:10101   199913 icon MDC_EVT_EEG_BACK_ACTIV_ABSENT

Definition for base term 3::3304 MDC_EVT_EEG_BACK_ACTIV_ABSENT is: Back Activity Absent

urn:iso:std:iso:11073:10101   199877 icon MDC_EVT_EEG_DISCHG_EPILEPTIFORM

Definition for base term 3::3268 MDC_EVT_EEG_DISCHG_EPILEPTIFORM is: Epileptiform discharges in EEG

urn:iso:std:iso:11073:10101   199873 icon MDC_EVT_EEG_DISCHG_SEIZ_CLIN

Definition for base term 3::3264 MDC_EVT_EEG_DISCHG_SEIZ_CLIN is: Clinical seizure discharge in EEG

urn:iso:std:iso:11073:10101   199863 icon MDC_EVT_EEG_SPK_AND_WV

Definition for base term 3::3254 MDC_EVT_EEG_SPK_AND_WV is: Spikes and waves in EEG

urn:iso:std:iso:11073:10101   199879 icon MDC_EVT_EEG_SPK_SHARP

Definition for base term 3::3270 MDC_EVT_EEG_SPK_SHARP is: Sharp spikes in EEG

urn:iso:std:iso:11073:10101   196845 icon MDC_EVT_ELEC_PWR_LINE_PROB

Definition for base term 3::236 MDC_EVT_ELEC_PWR_LINE_PROB is: 1. Electric power line: unspecified problem 2. Electric power line: unspecified problem.

urn:iso:std:iso:11073:10101   197341 icon MDC_EVT_EMER_STOP

Definition for base term 3::732 MDC_EVT_EMER_STOP is: Emergency Stop

urn:iso:std:iso:11073:10101   196635 icon MDC_EVT_EMPTY

Definition for base term 3::26 MDC_EVT_EMPTY is: A reservoir, etc., is empty.

urn:iso:std:iso:11073:10101   196847 icon MDC_EVT_ENDOTRACH_TUBE_LEAK

Definition for base term 3::238 MDC_EVT_ENDOTRACH_TUBE_LEAK is: 1. Endotracheal tube leak (ventilator) 2. Endotracheal tube leak (ventilator).

urn:iso:std:iso:11073:10101   197171 icon MDC_EVT_ENVIRON

Definition for base term 3::562 MDC_EVT_ENVIRON is: 1. Unspecified device environment warning 2. Unspecified environment(al) event.

urn:iso:std:iso:11073:10101   196637 icon MDC_EVT_EQU

Definition for base term 3::28 MDC_EVT_EQU is: 1. Unspecified device error 2. Unspecified device error.

urn:iso:std:iso:11073:10101   199911 icon MDC_EVT_EQU_HR_AND_PR

Definition for base term 3::3302 MDC_EVT_EQU_HR_AND_PR is: Cardiac and Pulse Rates are equal

urn:iso:std:iso:11073:10101   197199 icon MDC_EVT_EQUIP

Definition for base term 3::590 MDC_EVT_EQUIP is: 1. Unspecified equipment event 2. Unspecified Equipment event.

urn:iso:std:iso:11073:10101   196851 icon MDC_EVT_EQUIP_MALF

Definition for base term 3::242 MDC_EVT_EQUIP_MALF is: 1. Unspecified device malfunction error warning 2. {ECG} equipment malfunction.

urn:iso:std:iso:11073:10101   196639 icon MDC_EVT_ERR

Definition for base term 3::30 MDC_EVT_ERR is: 1. Error condition is detected 2. Problem in power supply module.

urn:iso:std:iso:11073:10101   199905 icon MDC_EVT_ERR_EQU_HR_AND_RR

Definition for base term 3::3296 MDC_EVT_ERR_EQU_HR_AND_RR is: 1. Heart rate and respiration rate are reported to be the same value. 2. Cardiac and Respiration Rates are reported to be equal.

urn:iso:std:iso:11073:10101   196641 icon MDC_EVT_ERRATIC

Definition for base term 3::32 MDC_EVT_ERRATIC is: Erratic condition is detected.

urn:iso:std:iso:11073:10101   196643 icon MDC_EVT_EXCESS

Definition for base term 3::34 MDC_EVT_EXCESS is: 1. A reservoir, etc., has excess content 2. Excess(ive) [NOS].

urn:iso:std:iso:11073:10101   196645 icon MDC_EVT_EXH

Definition for base term 3::36 MDC_EVT_EXH is: 1. A consumable is exhausted 2. Exhausted.

urn:iso:std:iso:11073:10101   196647 icon MDC_EVT_FAIL

Definition for base term 3::38 MDC_EVT_FAIL is: An action, data transmission, etc., failed.

urn:iso:std:iso:11073:10101   197129 icon MDC_EVT_FLOW_DISTURB

Definition for base term 3::520 MDC_EVT_FLOW_DISTURB is: 1. Flow is disturbed 2. {Pump} flow impediment.

urn:iso:std:iso:11073:10101   197191 icon MDC_EVT_FLOW_FLUID_LINE_RES_WARN

Definition for base term 3::582 MDC_EVT_FLOW_FLUID_LINE_RES_WARN is: 1. Advisory: Flow resistance warning 2. Flow resistance warning.

urn:iso:std:iso:11073:10101   196951 icon MDC_EVT_FLOW_LO

Definition for base term 3::342 MDC_EVT_FLOW_LO is: 1. Flow is low 2. {Pump} flow low.

urn:iso:std:iso:11073:10101   197185 icon MDC_EVT_FLOW_OBSTRUC

Definition for base term 3::576 MDC_EVT_FLOW_OBSTRUC is: 1. Flow is obstructed. 2. {Pump} flow is hindered.

urn:iso:std:iso:11073:10101   196953 icon MDC_EVT_FLOW_REVERSED

Definition for base term 3::344 MDC_EVT_FLOW_REVERSED is: 1. Flow is reversed 2. {Ventilator} reverse flow (not specific to inspiratory or expiratory limb).

urn:iso:std:iso:11073:10101   197345 icon MDC_EVT_FLOW_STOP_OPEN

Definition for base term 3::736 MDC_EVT_FLOW_STOP_OPEN is: Flow stop valve is open

urn:iso:std:iso:11073:10101   197201 icon MDC_EVT_FLUID_LINE_AIR

Definition for base term 3::592 MDC_EVT_FLUID_LINE_AIR is: Air in fluid line.

urn:iso:std:iso:11073:10101   196853 icon MDC_EVT_FLUID_LINE_DISTURB

Definition for base term 3::244 MDC_EVT_FLUID_LINE_DISTURB is: 1. Flow disturbance 2. Pump flow disturbance.

urn:iso:std:iso:11073:10101   196955 icon MDC_EVT_FLUID_LINE_DRIP_MALF

Definition for base term 3::346 MDC_EVT_FLUID_LINE_DRIP_MALF is: 1. Error in drip counting measurement 2. Error in drip counting measurement.

urn:iso:std:iso:11073:10101   196863 icon MDC_EVT_FLUID_LINE_FLOW_SENSOR_PROB

Definition for base term 3::254 MDC_EVT_FLUID_LINE_FLOW_SENSOR_PROB is: 1. Flow sensor problem 2. Flow sensor problem.

urn:iso:std:iso:11073:10101   197189 icon MDC_EVT_FLUID_LINE_HI_GT_LIM_PRESSURE

Definition for base term 3::580 MDC_EVT_FLUID_LINE_HI_GT_LIM_PRESSURE is: 1. High pressure in fluid line 2. Too much pressure in line.

urn:iso:std:iso:11073:10101   196855 icon MDC_EVT_FLUID_LINE_INFILT

Definition for base term 3::246 MDC_EVT_FLUID_LINE_INFILT is: 1. Infiltration of fluid line 2. Infiltration of fluid line.

urn:iso:std:iso:11073:10101   196857 icon MDC_EVT_FLUID_LINE_INGRESS

Definition for base term 3::248 MDC_EVT_FLUID_LINE_INGRESS is: 1. Ingress in fluid line 2. Fluid line ingress.

urn:iso:std:iso:11073:10101   196941 icon MDC_EVT_FLUID_LINE_OCCL

Definition for base term 3::332 MDC_EVT_FLUID_LINE_OCCL is: Occlusion of fluid line.

urn:iso:std:iso:11073:10101   196861 icon MDC_EVT_FLUID_LINE_PROB

Definition for base term 3::252 MDC_EVT_FLUID_LINE_PROB is: 1. Problem in fluid line 2. Problem in fluid line.

urn:iso:std:iso:11073:10101   197081 icon MDC_EVT_FRAM_ERR

Definition for base term 3::472 MDC_EVT_FRAM_ERR is: 1. Communication error: framing error 2. Communication error: framing error.

urn:iso:std:iso:11073:10101   196755 icon MDC_EVT_FUNC_UNAVAIL

Definition for base term 3::146 MDC_EVT_FUNC_UNAVAIL is: A resource is not available.

urn:iso:std:iso:11073:10101   196757 icon MDC_EVT_GAIN_HI

Definition for base term 3::148 MDC_EVT_GAIN_HI is: 1. Signal gain high: probably erroneous data extraction 2. Gain high.

urn:iso:std:iso:11073:10101   196759 icon MDC_EVT_GAIN_LO

Definition for base term 3::150 MDC_EVT_GAIN_LO is: 1. Signal gain low: probably erroneous data extraction 2. Gain low.

urn:iso:std:iso:11073:10101   196867 icon MDC_EVT_GAS_AGENT_IDENT_MALF

Definition for base term 3::258 MDC_EVT_GAS_AGENT_IDENT_MALF is: 1. Gas agent identification malfunction 2. Gas agent identification malfunction.

urn:iso:std:iso:11073:10101   196865 icon MDC_EVT_GAS_CONTAM

Definition for base term 3::256 MDC_EVT_GAS_CONTAM is: Gas contamination

urn:iso:std:iso:11073:10101   196869 icon MDC_EVT_GAS_LINE_PROB

Definition for base term 3::260 MDC_EVT_GAS_LINE_PROB is: 1. Gas line problem 2. Gas line problem (with the breathing system).

urn:iso:std:iso:11073:10101   196761 icon MDC_EVT_HANDL_ERR

Definition for base term 3::152 MDC_EVT_HANDL_ERR is: 1. Not specified, unnormal handling of a device, device component, cabling, or transducer 2. Not specified, unnormal handling of a device, device component, cabling, or transducer.

urn:iso:std:iso:11073:10101   197355 icon MDC_EVT_HANDSET_DETACHED

Definition for base term 3::746 MDC_EVT_HANDSET_DETACHED is: 1. Advisory: Handset detached 2. {*} Handset is detached from unit

urn:iso:std:iso:11073:10101   196871 icon MDC_EVT_HEATING_PWR_PROB

Definition for base term 3::262 MDC_EVT_HEATING_PWR_PROB is: 1. Heater power problem 2. Heating Power problem.

urn:iso:std:iso:11073:10101   196649 icon MDC_EVT_HI

Definition for base term 3::40 MDC_EVT_HI is: {numeric observation} > high limit

urn:iso:std:iso:11073:10101   196651 icon MDC_EVT_HI_GT_LIM

Definition for base term 3::42 MDC_EVT_HI_GT_LIM is: A metric exceeds a given threshold

urn:iso:std:iso:11073:10101   196653 icon MDC_EVT_HI_VAL_GT_LIM

Definition for base term 3::44 MDC_EVT_HI_VAL_GT_LIM is: A metric exceeds a given threshold.

urn:iso:std:iso:11073:10101   196873 icon MDC_EVT_HOSE_LEAK

Definition for base term 3::264 MDC_EVT_HOSE_LEAK is: 1. Leak in hose within breathing system 2. Leak in breathing system.

urn:iso:std:iso:11073:10101   196875 icon MDC_EVT_HOSE_OBSTRUC

Definition for base term 3::266 MDC_EVT_HOSE_OBSTRUC is: 1. Flow in hose is obstructed 2. (Ventilator) hose obstructed.

urn:iso:std:iso:11073:10101   197099 icon MDC_EVT_HUMID_EXCESS

Definition for base term 3::490 MDC_EVT_HUMID_EXCESS is: 1. Too much humidity for accurate measurement 2. Too much humidity for accurate measurement.

urn:iso:std:iso:11073:10101   197187 icon MDC_EVT_HUMID_HI_ERR

Definition for base term 3::578 MDC_EVT_HUMID_HI_ERR is: 1. Too much humidity for accurate measurement 2. Too much humidity for accurate measurement.

urn:iso:std:iso:11073:10101   197329 icon MDC_EVT_IDLE

Definition for base term 3::720 MDC_EVT_IDLE is: 1. Idle state of, e.g., device 2. Idle state of, e.g., {pump} device

urn:iso:std:iso:11073:10101   197209 icon MDC_EVT_INCOMPAT

Definition for base term 3::600 MDC_EVT_INCOMPAT is: 1. Incompatibility of nomenclature or processing component, etc. 2. This version of the {NMT} measurement module is not supported, or the module firmware is incomplete and needs to be upgraded.

urn:iso:std:iso:11073:10101   196655 icon MDC_EVT_INCORRECT

Definition for base term 3::46 MDC_EVT_INCORRECT is: 1. Incorrect result of a calculation, e.g., CRC in data transmission, of a data structure, etc., detected 2. Incorrect result of a calculation, e.g., CRC in data transmission, of a data structure, etc., detected.

urn:iso:std:iso:11073:10101   196657 icon MDC_EVT_INFILT

Definition for base term 3::48 MDC_EVT_INFILT is: 1. Infiltration NOS 2. Infiltration [NOS].

urn:iso:std:iso:11073:10101   196763 icon MDC_EVT_INFLAT_OVER

Definition for base term 3::154 MDC_EVT_INFLAT_OVER is: 1. Over inflated (non-specific) 2. Over-inflated.

urn:iso:std:iso:11073:10101   196659 icon MDC_EVT_INGRESS

Definition for base term 3::50 MDC_EVT_INGRESS is: 1. Ingress of contaminant NOS 2. Ingress [NOS].

urn:iso:std:iso:11073:10101   196661 icon MDC_EVT_INOP

Definition for base term 3::52 MDC_EVT_INOP is: 1. (Un)intentional inoperable condition NOS 2. (Un)intentional inoperable condition.

urn:iso:std:iso:11073:10101   196957 icon MDC_EVT_INTENS_ERR

Definition for base term 3::348 MDC_EVT_INTENS_ERR is: 1. Error Event: Radiation source intensity incorrect 2. Intensity error (NOS).

urn:iso:std:iso:11073:10101   196959 icon MDC_EVT_INTENS_LIGHT_ERR

Definition for base term 3::350 MDC_EVT_INTENS_LIGHT_ERR is: 1. Error Event: Light source intensity incorrect 2. Light Intensity error.

urn:iso:std:iso:11073:10101   196663 icon MDC_EVT_INTERF

Definition for base term 3::54 MDC_EVT_INTERF is: 1. Interference NOS 2. Interference [NOS].

urn:iso:std:iso:11073:10101   196665 icon MDC_EVT_INTERRUP

Definition for base term 3::56 MDC_EVT_INTERRUP is: A measurement, process, or data transmission was interrupted.

urn:iso:std:iso:11073:10101   196667 icon MDC_EVT_IRREG

Definition for base term 3::58 MDC_EVT_IRREG is: Irregular rhythm or waveform in a signal, etc.

urn:iso:std:iso:11073:10101   196877 icon MDC_EVT_LEAD_DISCONN

Definition for base term 3::268 MDC_EVT_LEAD_DISCONN is: 1. Error Event: (ECG) Lead Disconnected (specialized form of the generic disconnect event. In case of ECG, some ECG devices reconstruct leads when a single lead of a multilead cable falls off. This needs a special user notification, because the situation might not be visible on the display waves. Reasoning: see above.) 2. Error Event: {ECG} Lead Disconnected (specialized form of the generic disconnect event). [In the case of ECG, some ECG devices reconstruct leads when a single lead of a multilead cable falls off. This needs a special user notification, because the situation might not be visible on the display waves. Reasoning: see above.]

urn:iso:std:iso:11073:10101   196879 icon MDC_EVT_LEAD_NOISY

Definition for base term 3::270 MDC_EVT_LEAD_NOISY is: 1. Error Event: (ECG) Lead Noisy 2. {ECG} lead data is invalid due to excessive signal noise, bad electrode contact, interference from external devices and/or incorrect {ST} lead selection(s).

urn:iso:std:iso:11073:10101   196881 icon MDC_EVT_LEAD_OFF

Definition for base term 3::272 MDC_EVT_LEAD_OFF is: 1. Error Event: (ECG) Lead Disconnected 2. {ECG} Lead off

urn:iso:std:iso:11073:10101   196883 icon MDC_EVT_LEADS_OFF

Definition for base term 3::274 MDC_EVT_LEADS_OFF is: 1. Error Event: (ECG) Leads Disconnected 2. One or more {ECG} leads are not attached to the patient.

urn:iso:std:iso:11073:10101   196669 icon MDC_EVT_LEAK

Definition for base term 3::60 MDC_EVT_LEAK is: 1. Leakage in a gas or fluid filled system detected 2. Leakage in a gas or fluid filled system detected.

urn:iso:std:iso:11073:10101   196887 icon MDC_EVT_LIGHT_INTERF

Definition for base term 3::278 MDC_EVT_LIGHT_INTERF is: 1. Error Event: Light Interference (SpO2 measurement, special kind of interference) 2. {SpO2} Regulation error: an excessive amount of ambient light is present, giving low amplitude and inaccurate readings as a result.

urn:iso:std:iso:11073:10101   197093 icon MDC_EVT_LIGHT_ON

Definition for base term 3::484 MDC_EVT_LIGHT_ON is: 1. Error Event: Lights in the (sleep measurement) room are switched on {status lights on/off} 2. Lights in the {sleep measurement} room are switched on (or device status or illumination lights are on).

urn:iso:std:iso:11073:10101   196889 icon MDC_EVT_LIGHT_SRC_ABSENT

Definition for base term 3::280 MDC_EVT_LIGHT_SRC_ABSENT is: 1. Error Event: Light source absent 2. Light source absent or missing.

urn:iso:std:iso:11073:10101   196885 icon MDC_EVT_LIGHTS_IN_ROOM_OFF

Definition for base term 3::276 MDC_EVT_LIGHTS_IN_ROOM_OFF is: 1. Lights in the (sleep measurement) room are switched off. 2. Lights in the {sleep measurement} room are switched off.

urn:iso:std:iso:11073:10101   197059 icon MDC_EVT_LIMIT_AL_HI

Definition for base term 3::450 MDC_EVT_LIMIT_AL_HI is: A metric exceeds a given threshold.

urn:iso:std:iso:11073:10101   197163 icon MDC_EVT_LIMIT_AL_LO

Definition for base term 3::554 MDC_EVT_LIMIT_AL_LO is: A metric falls short of a given threshold.

urn:iso:std:iso:11073:10101   196671 icon MDC_EVT_LO

Definition for base term 3::62 MDC_EVT_LO is: {numeric observation} < low limit

urn:iso:std:iso:11073:10101   196673 icon MDC_EVT_LO_LT_LIM

Definition for base term 3::64 MDC_EVT_LO_LT_LIM is: A metric falls short of a given threshold

urn:iso:std:iso:11073:10101   196675 icon MDC_EVT_LO_VAL_LT_LIM

Definition for base term 3::66 MDC_EVT_LO_VAL_LT_LIM is: A metric falls short of a given threshold.

urn:iso:std:iso:11073:10101   196677 icon MDC_EVT_LOST

Definition for base term 3::68 MDC_EVT_LOST is: Signal or synchronization, etc., was lost.

urn:iso:std:iso:11073:10101   203789 icon MDC_EVT_LS_ACCELEROMETER

Definition for base term 3::7180 MDC_EVT_LS_ACCELEROMETER is: 1. Report of item acceleration increase potentially due to leaning or falling 2. Report of item aceleration increase potentially due to leaning or falling.

urn:iso:std:iso:11073:10101   203799 icon MDC_EVT_LS_BATTERY

Definition for base term 3::7190 MDC_EVT_LS_BATTERY is: 1. Report of item active tag battery status 2. Report of item active tag battery status.

urn:iso:std:iso:11073:10101   203783 icon MDC_EVT_LS_BOUNDARY

Definition for base term 3::7174 MDC_EVT_LS_BOUNDARY is: 1. Report of constrained location item exceeding defined boundary 2. Report of constrained location item exceeding defined boundary.

urn:iso:std:iso:11073:10101   203785 icon MDC_EVT_LS_COLOCATION

Definition for base term 3::7176 MDC_EVT_LS_COLOCATION is: 1. Report of item colocation with another item 2. Report of item colocation with another item.

urn:iso:std:iso:11073:10101   203777 icon MDC_EVT_LS_DEVICE

Definition for base term 3::7168 MDC_EVT_LS_DEVICE is: 1. Report of location of a device as item 2. Report of location of a device as item.

urn:iso:std:iso:11073:10101   203787 icon MDC_EVT_LS_DWELL

Definition for base term 3::7178 MDC_EVT_LS_DWELL is: 1. Report of expected moving item dwelling in location longer than a defined period 2. Report of expected moving item dwelling in location longer than a defined period.

urn:iso:std:iso:11073:10101   203797 icon MDC_EVT_LS_ENVIRONMENT

Definition for base term 3::7188 MDC_EVT_LS_ENVIRONMENT is: 1. Report of item environment of temperature, humidity, pressure, gases 2. Report of item environment of temperature, humidity, pressure, gases.

urn:iso:std:iso:11073:10101   203793 icon MDC_EVT_LS_INTERACTION

Definition for base term 3::7184 MDC_EVT_LS_INTERACTION is: 1. Report of operator interaction with item by button press, cord pull 2. Report of operator interaction with item by button press, cord pull.

urn:iso:std:iso:11073:10101   203795 icon MDC_EVT_LS_MISSING

Definition for base term 3::7186 MDC_EVT_LS_MISSING is: 1. Report of loss of communication with item 2. Report of loss of communication with item.

urn:iso:std:iso:11073:10101   203781 icon MDC_EVT_LS_MOVEMENT

Definition for base term 3::7172 MDC_EVT_LS_MOVEMENT is: 1. Report of movement of expected stationary item 2. Report of movement of expected stationary item.

urn:iso:std:iso:11073:10101   203779 icon MDC_EVT_LS_PERSON

Definition for base term 3::7170 MDC_EVT_LS_PERSON is: 1. Report of location of a person as item 2. Report of location of a person as item.

urn:iso:std:iso:11073:10101   203791 icon MDC_EVT_LS_TAMPER

Definition for base term 3::7182 MDC_EVT_LS_TAMPER is: 1. Report of item tamper interlock being indicated 2. Report of item tamper interlock being indicated.

urn:iso:std:iso:11073:10101   196679 icon MDC_EVT_MALF

Definition for base term 3::70 MDC_EVT_MALF is: 1. Malfunction of a device, VMD, or sensor is detected. 2. {NMT} hardware malfunction; unplugging or restarting the {NMT} measurement module may correct the problem.

urn:iso:std:iso:11073:10101   197017 icon MDC_EVT_MATERIAL_LOW_OR_OUT

Definition for base term 3::408 MDC_EVT_MATERIAL_LOW_OR_OUT is: Unspecified tools or agents (e.g., calibration fluids) are low.

urn:iso:std:iso:11073:10101   196891 icon MDC_EVT_MED_GAS_SUPPLY_LO

Definition for base term 3::282 MDC_EVT_MED_GAS_SUPPLY_LO is: 1. Medical gas or supply low 2. Medical gas or supply low.

urn:iso:std:iso:11073:10101   196765 icon MDC_EVT_MIX_ERR

Definition for base term 3::156 MDC_EVT_MIX_ERR is: 1. Mix errror 2. Gas (or other) mixer inoperable.

urn:iso:std:iso:11073:10101   196681 icon MDC_EVT_MODE

Definition for base term 3::72 MDC_EVT_MODE is: 1. Mode status 2. Mode status (notification)

urn:iso:std:iso:11073:10101   196893 icon MDC_EVT_MODULE_DISCONN

Definition for base term 3::284 MDC_EVT_MODULE_DISCONN is: 1. Module disconnnected 2. Module disconnected

urn:iso:std:iso:11073:10101   196895 icon MDC_EVT_MODULE_EXCESS

Definition for base term 3::286 MDC_EVT_MODULE_EXCESS is: 1. Too many [plugin] modules 2. Too many modules.

urn:iso:std:iso:11073:10101   196897 icon MDC_EVT_MODULE_UNK

Definition for base term 3::288 MDC_EVT_MODULE_UNK is: 1. [Plugin] Module unknown 2. [Plugin] Module unknown.

urn:iso:std:iso:11073:10101   196899 icon MDC_EVT_MS_SUBSYS_DISCONN

Definition for base term 3::290 MDC_EVT_MS_SUBSYS_DISCONN is: 1. Subsystem disconnected 2. {Measurement module} subsystem disconnected.

urn:iso:std:iso:11073:10101   196901 icon MDC_EVT_MSG_COMM_ERR

Definition for base term 3::292 MDC_EVT_MSG_COMM_ERR is: 1. Error Event: Communication Message Error 2. Subsystem has received false data packet.

urn:iso:std:iso:11073:10101   197061 icon MDC_EVT_MSG_CORRUPT

Definition for base term 3::452 MDC_EVT_MSG_CORRUPT is: Subsystem has received false data packet.

urn:iso:std:iso:11073:10101   197025 icon MDC_EVT_MSG_ERR_PROC

Definition for base term 3::416 MDC_EVT_MSG_ERR_PROC is: 1. Unspecified processing error message 2. Messaging Error.

urn:iso:std:iso:11073:10101   197011 icon MDC_EVT_MSG_NOM_ERR

Definition for base term 3::402 MDC_EVT_MSG_NOM_ERR is: A message contains wrong code.

urn:iso:std:iso:11073:10101   197079 icon MDC_EVT_MSG_SEMAN_ERR

Definition for base term 3::470 MDC_EVT_MSG_SEMAN_ERR is: Subsystem has received false data packet.

urn:iso:std:iso:11073:10101   197087 icon MDC_EVT_MSG_SYNTAX_UNDEF

Definition for base term 3::478 MDC_EVT_MSG_SYNTAX_UNDEF is: 1. Undefined communication message syntax 2. Undefined communication message syntax.

urn:iso:std:iso:11073:10101   196961 icon MDC_EVT_MSMT_DISCONN

Definition for base term 3::352 MDC_EVT_MSMT_DISCONN is: 1. Error Event: Measurement Unplugged (e.g., in modular patient monitor. Reasoning: In contrast to the disconnect events below, this event indicates that a measurement module was manually (==voluntarily) removed. Dependent on the alarm configuration of a monitor (specifically, with latched alarms), this condition must be announced to the user; and the user must specifically acknowledge the situation.) 2. Error Event: {*} measurement unplugged (e.g., in modular patient monitor. Reasoning: In contrast to the disconnect events below, this event indicates that a measurement module was manually (==voluntarily) removed. Dependent on the alarm configuration of a monitor (specifically, with latched alarms), this condition must be announced to the user; and the user must specifically acknowledge the situation.). [The optional attribute MDC_ATTR_EVT_INTENTIONALITY may be included in the alert message to indicate degree of intentionality by the user.]

urn:iso:std:iso:11073:10101   196963 icon MDC_EVT_MSMT_ERR

Definition for base term 3::354 MDC_EVT_MSMT_ERR is: 1. Unspecified error in processing of a biosignal 2. Unspecified error in processing of {temperature} biosignal.

urn:iso:std:iso:11073:10101   196965 icon MDC_EVT_MSMT_FAIL

Definition for base term 3::356 MDC_EVT_MSMT_FAIL is: 1. Error Event: Measurement Failed (e.g., a noninvasive blood pressure) 2. Error Event: {NBP} measurement failed (e.g., a noninvasive blood pressure).

urn:iso:std:iso:11073:10101   196967 icon MDC_EVT_MSMT_INOP

Definition for base term 3::358 MDC_EVT_MSMT_INOP is: 1. Error Event: Measurement inoperable, Failed (e.g., a noninvasive blood pressure) 2. {SpO2} No measurement

urn:iso:std:iso:11073:10101   196969 icon MDC_EVT_MSMT_INTERF

Definition for base term 3::360 MDC_EVT_MSMT_INTERF is: 1. Error Event: Measurement intereference (e.g., a noninvasive blood pressure) 2. Interference in measurement

urn:iso:std:iso:11073:10101   197045 icon MDC_EVT_MSMT_INTERF_ERR

Definition for base term 3::436 MDC_EVT_MSMT_INTERF_ERR is: 1. Interference in measurement 2. Error due to interference in measurement

urn:iso:std:iso:11073:10101   196971 icon MDC_EVT_MSMT_INTERRUP

Definition for base term 3::362 MDC_EVT_MSMT_INTERRUP is: Error Event: Measurement Interrupted (e.g., a noninvasive blood pressure) (there is a generic interrupted code for processing; however, this code does not have to do with processing. As an example of this code, the user might simply hit a stop button, and this action makes the measurement invalid.)

urn:iso:std:iso:11073:10101   196973 icon MDC_EVT_MSMT_RANGE_OVER

Definition for base term 3::364 MDC_EVT_MSMT_RANGE_OVER is: 1. Error Event: Measurement Range Exceeded, i.e., the signal is out of the physiological range that is specified in the Metric object. 2. Error Event: Metric (measurement) overrange. 3. Error Event: {NBP} measurement range exceeded, i.e., the signal is out of the physiological range that is specified in the Metric object.

urn:iso:std:iso:11073:10101   196975 icon MDC_EVT_MSMT_RANGE_UNDER

Definition for base term 3::366 MDC_EVT_MSMT_RANGE_UNDER is: 1. Error Event: Metric (measurement) underrange 2. {NBP} metric (measurement) underrange.

urn:iso:std:iso:11073:10101   197211 icon MDC_EVT_MULT_REPLY_UNAVAIL

Definition for base term 3::602 MDC_EVT_MULT_REPLY_UNAVAIL is: The multiple reply remote operation function is not available (see Clause 6 in ISO/IEEE 11073-20101:2004)

urn:iso:std:iso:11073:10101   197065 icon MDC_EVT_NBP_CUFF_DISCONN_OR_LEAK

Definition for base term 3::456 MDC_EVT_NBP_CUFF_DISCONN_OR_LEAK is: 1. Cuff is disconnected or leaking, e.g., in NIBP. 2. NBP cuff is disconnected or leaking.

urn:iso:std:iso:11073:10101   197063 icon MDC_EVT_NBP_MOTION_DETEC

Definition for base term 3::454 MDC_EVT_NBP_MOTION_DETEC is: 1. Motions are detected, e.g., in NIBP measurement. 2. NBP motion artifact has been detected.

urn:iso:std:iso:11073:10101   196683 icon MDC_EVT_NOISY

Definition for base term 3::74 MDC_EVT_NOISY is: Signal is noisy.

urn:iso:std:iso:11073:10101   196687 icon MDC_EVT_NOT_DEFLATED

Definition for base term 3::78 MDC_EVT_NOT_DEFLATED is: 1. Cuff not fully deflated 2. {NBP Cuff} Deflation error

urn:iso:std:iso:11073:10101   196905 icon MDC_EVT_O2_SUPPLY_LO

Definition for base term 3::296 MDC_EVT_O2_SUPPLY_LO is: 1. Too low O2 delivery (concentration or flow) 2. Too low O2 delivery (concentration or flow).

urn:iso:std:iso:11073:10101   196689 icon MDC_EVT_OBSTRUC

Definition for base term 3::80 MDC_EVT_OBSTRUC is: Flow is hindered.

urn:iso:std:iso:11073:10101   197015 icon MDC_EVT_OP_INVALID

Definition for base term 3::406 MDC_EVT_OP_INVALID is: 1. Unspecified handling error 2. Unspecified handling error.

urn:iso:std:iso:11073:10101   196907 icon MDC_EVT_OPTIC_MODULE_ABSENT

Definition for base term 3::298 MDC_EVT_OPTIC_MODULE_ABSENT is: 1. Optical Module Absent 2. Optical module absent or missing.

urn:iso:std:iso:11073:10101   196909 icon MDC_EVT_OPTIC_MODULE_DEFECT

Definition for base term 3::300 MDC_EVT_OPTIC_MODULE_DEFECT is: 1. Optical Module Defect 2. Optical module defect.

urn:iso:std:iso:11073:10101   196697 icon MDC_EVT_OVER

Definition for base term 3::88 MDC_EVT_OVER is: Overflow was detected in a measurement or calculation

urn:iso:std:iso:11073:10101   196699 icon MDC_EVT_OVERFLOW

Definition for base term 3::90 MDC_EVT_OVERFLOW is: Overflow was detected in a measurement or calculation.

urn:iso:std:iso:11073:10101   196911 icon MDC_EVT_PAPER_PROB

Definition for base term 3::302 MDC_EVT_PAPER_PROB is: 1. Problem with recording paper 2. [Hardcopy] paper problem.

urn:iso:std:iso:11073:10101   197083 icon MDC_EVT_PARITY_ERR

Definition for base term 3::474 MDC_EVT_PARITY_ERR is: 1. Communication error: parity error 2. Communication error: parity error.

urn:iso:std:iso:11073:10101   197301 icon MDC_EVT_PATIENT_CHANGE

Definition for base term 3::692 MDC_EVT_PATIENT_CHANGE is: 1. Advisory: The patient connected to a device has changed 2. Patient Change

urn:iso:std:iso:11073:10101   197303 icon MDC_EVT_PATIENT_ID_CHANGE

Definition for base term 3::694 MDC_EVT_PATIENT_ID_CHANGE is: 1. Advisory: The ID of the patient connected to the device has changed 2. Patient ID Change

urn:iso:std:iso:11073:10101   197305 icon MDC_EVT_PATIENT_WEIGHT_CHANGE

Definition for base term 3::696 MDC_EVT_PATIENT_WEIGHT_CHANGE is: 1. Advisory: The patient weight has changed 2. Patient Weight Change

urn:iso:std:iso:11073:10101   197259 icon MDC_EVT_PCA_DOOR_UNLOCKED

Definition for base term 3::650 MDC_EVT_PCA_DOOR_UNLOCKED is: 1. Advisory: Patient controlled analgesia: door unlocked 2. PCA Door is unlocked

urn:iso:std:iso:11073:10101   197261 icon MDC_EVT_PCA_HANDSET_DETACHED

Definition for base term 3::652 MDC_EVT_PCA_HANDSET_DETACHED is: 1. Advisory: Patient controlled analgesia: handset detached 2. PCA Handset is detached from unit.

urn:iso:std:iso:11073:10101   197263 icon MDC_EVT_PCA_MAX_LIMIT

Definition for base term 3::654 MDC_EVT_PCA_MAX_LIMIT is: 1. Advisory: Patient controlled analgesia: maximum limit reached 2. Maximum PCA dose limit reached

urn:iso:std:iso:11073:10101   197265 icon MDC_EVT_PCA_PAUSED

Definition for base term 3::656 MDC_EVT_PCA_PAUSED is: 1. Advisory: Patient controlled analgesia: paused 2. PCA paused, reason not specified.

urn:iso:std:iso:11073:10101   196913 icon MDC_EVT_PLUGIN_INCORRECT

Definition for base term 3::304 MDC_EVT_PLUGIN_INCORRECT is: 1. Incorrect plugin [module] 2. Incorrect plugin [module].

urn:iso:std:iso:11073:10101   196915 icon MDC_EVT_PLUGIN_POSN_IRREG

Definition for base term 3::306 MDC_EVT_PLUGIN_POSN_IRREG is: Problem in position of a plug-in device

urn:iso:std:iso:11073:10101   196767 icon MDC_EVT_POSN_IRREG

Definition for base term 3::158 MDC_EVT_POSN_IRREG is: 1. Irregular position of a plug-in device 2. Problem in position of a plug-in device 3. Position irregular. 4. Irregular position of a plug-in device.

urn:iso:std:iso:11073:10101   196769 icon MDC_EVT_POSN_PROB

Definition for base term 3::160 MDC_EVT_POSN_PROB is: 1. Irregular position of a plug-in device 2. Problem in position of a plug-in device 3. Position irregular. 4. Irregular position of a plug-in device.

urn:iso:std:iso:11073:10101   197169 icon MDC_EVT_POWER_PROB

Definition for base term 3::560 MDC_EVT_POWER_PROB is: Problem in power supply

urn:iso:std:iso:11073:10101   197067 icon MDC_EVT_POWER_SUPPLY_PROB

Definition for base term 3::458 MDC_EVT_POWER_SUPPLY_PROB is: 1. Problem in power supply 2. {*} power supply problem.

urn:iso:std:iso:11073:10101   196987 icon MDC_EVT_PRESS_CUFF_OVER

Definition for base term 3::378 MDC_EVT_PRESS_CUFF_OVER is: 1. Cuff over pressure 2. {NBP} cuff overpressure.

urn:iso:std:iso:11073:10101   197167 icon MDC_EVT_PRESS_FLUID_LINE_EXCESS

Definition for base term 3::558 MDC_EVT_PRESS_FLUID_LINE_EXCESS is: 1. High pressure in fluid line 2. Too much pressure in line.

urn:iso:std:iso:11073:10101   196977 icon MDC_EVT_PRESS_HI_GT_LIM

Definition for base term 3::368 MDC_EVT_PRESS_HI_GT_LIM is: High pressure

urn:iso:std:iso:11073:10101   196979 icon MDC_EVT_PRESS_HI_VAL_GT_LIM

Definition for base term 3::370 MDC_EVT_PRESS_HI_VAL_GT_LIM is: High pressure

urn:iso:std:iso:11073:10101   196981 icon MDC_EVT_PRESS_SUBATMOS

Definition for base term 3::372 MDC_EVT_PRESS_SUBATMOS is: 1. Pressure subatmospheric [Vent] 2. [Vent] Pressure subatmospheric.

urn:iso:std:iso:11073:10101   196983 icon MDC_EVT_PRESS_SUPPLY_HI

Definition for base term 3::374 MDC_EVT_PRESS_SUPPLY_HI is: 1. High supply pressure 2. Supply pressure high.

urn:iso:std:iso:11073:10101   196985 icon MDC_EVT_PRESS_SUPPLY_LO

Definition for base term 3::376 MDC_EVT_PRESS_SUPPLY_LO is: 1. Low supply pressure 2. Supply pressure low.

urn:iso:std:iso:11073:10101   196701 icon MDC_EVT_PROB

Definition for base term 3::92 MDC_EVT_PROB is: 1. Unspecified device error 2. Problem (NOS).

urn:iso:std:iso:11073:10101   197029 icon MDC_EVT_PROC

Definition for base term 3::420 MDC_EVT_PROC is: 1. Unspecified processing error 2. Unspecified processing event.

urn:iso:std:iso:11073:10101   196771 icon MDC_EVT_PROC_ERR

Definition for base term 3::162 MDC_EVT_PROC_ERR is: 1. Unspecified processing error 2. Unspecified processing error.

urn:iso:std:iso:11073:10101   199917 icon MDC_EVT_PULS_NON_PULSATILE

Definition for base term 3::3308 MDC_EVT_PULS_NON_PULSATILE is: 1. NIBP non pulsatile 2. Pulse absent or non-pulsatile

urn:iso:std:iso:11073:10101   197353 icon MDC_EVT_PUMP_CHAMBER_BLOCKED

Definition for base term 3::744 MDC_EVT_PUMP_CHAMBER_BLOCKED is: Pump chamber blocked.

urn:iso:std:iso:11073:10101   197207 icon MDC_EVT_PUMP_FLOW_FREE

Definition for base term 3::598 MDC_EVT_PUMP_FLOW_FREE is: 1. Pump in free flow 2. Pump in free flow.

urn:iso:std:iso:11073:10101   197183 icon MDC_EVT_PUMP_SYRINGE_DELIV_TIMEOUT

Definition for base term 3::574 MDC_EVT_PUMP_SYRINGE_DELIV_TIMEOUT is: Configured time to deliver whole syringe/bottle is over.

urn:iso:std:iso:11073:10101   197195 icon MDC_EVT_PUMP_VOL_TBI_COMP

Definition for base term 3::586 MDC_EVT_PUMP_VOL_TBI_COMP is: 1. Total volume infused (pump) 2. Total programmed volume infused (pump). 3. Infusion complete, where the programmed volume has been infused (pump).

urn:iso:std:iso:11073:10101   197343 icon MDC_EVT_PWR_LOSS

Definition for base term 3::734 MDC_EVT_PWR_LOSS is: 1. Loss of power supply 2. Power Loss

urn:iso:std:iso:11073:10101   197021 icon MDC_EVT_QOS

Definition for base term 3::412 MDC_EVT_QOS is: 1. Communication error: quality of service (QOS) 2. Unspecified Quality of Service event.

urn:iso:std:iso:11073:10101   196773 icon MDC_EVT_RANGE_ERR

Definition for base term 3::164 MDC_EVT_RANGE_ERR is: 1. Signal amplitude is incorrect for processing 2. Signal out of range

urn:iso:std:iso:11073:10101   196775 icon MDC_EVT_RANGE_OVER

Definition for base term 3::166 MDC_EVT_RANGE_OVER is: 1. Signal amplitude is too high for processing. 2. {Impedance respiration rate} Out of range (high)

urn:iso:std:iso:11073:10101   196777 icon MDC_EVT_RANGE_UNDER

Definition for base term 3::168 MDC_EVT_RANGE_UNDER is: 1. Signal amplitude is too low for processing, e.g., waveform detection. 2. {ST} Out of range (low)

urn:iso:std:iso:11073:10101   196739 icon MDC_EVT_RECOV_ERR

Definition for base term 3::130 MDC_EVT_RECOV_ERR is: 1. Recoverable state machine error in communication 2. Recoverable state machine error in communication.

urn:iso:std:iso:11073:10101   199887 icon MDC_EVT_RESP_BREATHING_SPONT_ASSIST_PSW

Definition for base term 3::3278 MDC_EVT_RESP_BREATHING_SPONT_ASSIST_PSW is: 1. Assisted spontaneous breathing longer than a predefined time span (PSW) 2. Assisted spontaneous breathing longer then a predefined time span (PSW)

urn:iso:std:iso:11073:10101   199865 icon MDC_EVT_RESP_VOL_BREATHING_IRREG

Definition for base term 3::3256 MDC_EVT_RESP_VOL_BREATHING_IRREG is: Breathing volume not constant

urn:iso:std:iso:11073:10101   197123 icon MDC_EVT_RESPIRATOR_TEMP_HI

Definition for base term 3::514 MDC_EVT_RESPIRATOR_TEMP_HI is: Respirator device temperature is too high.

urn:iso:std:iso:11073:10101   196705 icon MDC_EVT_REVERSED

Definition for base term 3::96 MDC_EVT_REVERSED is: Flow is reversed

urn:iso:std:iso:11073:10101   196917 icon MDC_EVT_SENSOR_DISCONN

Definition for base term 3::308 MDC_EVT_SENSOR_DISCONN is: 1. Sensor disconnection or fault 2. {SpO2} sensor disconnection or fault.

urn:iso:std:iso:11073:10101   196919 icon MDC_EVT_SENSOR_MALF

Definition for base term 3::310 MDC_EVT_SENSOR_MALF is: 1. Sensor malfunction 2. {SpO2} sensor malfunction. 3. {SpO2} sensor malfunction, a current state or condition of faulty or improper functioning.

urn:iso:std:iso:11073:10101   196921 icon MDC_EVT_SENSOR_PROB

Definition for base term 3::312 MDC_EVT_SENSOR_PROB is: 1. Flow sensor problem 2. {SpO2} sensor problem.

urn:iso:std:iso:11073:10101   196779 icon MDC_EVT_SHAPE_ERR

Definition for base term 3::170 MDC_EVT_SHAPE_ERR is: [Pattern] Shape error.

urn:iso:std:iso:11073:10101   196709 icon MDC_EVT_SHORT

Definition for base term 3::100 MDC_EVT_SHORT is: 1. Error Event: Sensor electrical lead (e.g., ECG) is shorted (NOS) 2. Short (electrical) [NOS].

urn:iso:std:iso:11073:10101   196923 icon MDC_EVT_SIDESTRM_MALF

Definition for base term 3::314 MDC_EVT_SIDESTRM_MALF is: 1. [CO2] Sidestream malfunction 2. {Airway CO2} sidestream malfunction.

urn:iso:std:iso:11073:10101   196925 icon MDC_EVT_SIDESTRM_OFF

Definition for base term 3::316 MDC_EVT_SIDESTRM_OFF is: 1. [CO2] Sidestream off 2. {Airway CO2} sidestream off.

urn:iso:std:iso:11073:10101   196927 icon MDC_EVT_SIDESTRM_ON

Definition for base term 3::318 MDC_EVT_SIDESTRM_ON is: 1. [CO2] Sidestream on 2. {Airway CO2} sidestream on.

urn:iso:std:iso:11073:10101   197053 icon MDC_EVT_SIG_ABSENT

Definition for base term 3::444 MDC_EVT_SIG_ABSENT is: 1. Typically, a zero voltage signal 2. Typically, a zero voltage signal.

urn:iso:std:iso:11073:10101   197103 icon MDC_EVT_SIG_ABSENT_OSCIL

Definition for base term 3::494 MDC_EVT_SIG_ABSENT_OSCIL is: 1. Oscillation in signal is absent 2. No oscillation.

urn:iso:std:iso:11073:10101   197105 icon MDC_EVT_SIG_AMPL_INVALID

Definition for base term 3::496 MDC_EVT_SIG_AMPL_INVALID is: 1. Signal amplitude is not as expected 2. Invalid signal - shape/amplitude of signal unnormal.

urn:iso:std:iso:11073:10101   197109 icon MDC_EVT_SIG_ARTIFACT

Definition for base term 3::500 MDC_EVT_SIG_ARTIFACT is: 1. Signal artifact detected 2. {ECG} Artifact

urn:iso:std:iso:11073:10101   196781 icon MDC_EVT_SIG_ERRATIC

Definition for base term 3::172 MDC_EVT_SIG_ERRATIC is: Error Event: Signal erratic

urn:iso:std:iso:11073:10101   197013 icon MDC_EVT_SIG_GAIN_LO

Definition for base term 3::404 MDC_EVT_SIG_GAIN_LO is: 1. Signal gain low: probably erroneous data extraction 2. Signal gain low: probably erroneous data extraction.

urn:iso:std:iso:11073:10101   196989 icon MDC_EVT_SIG_LO

Definition for base term 3::380 MDC_EVT_SIG_LO is: 1. Signal is low 2. {SpO2} signal low.

urn:iso:std:iso:11073:10101   197049 icon MDC_EVT_SIG_NOISY

Definition for base term 3::440 MDC_EVT_SIG_NOISY is: Noisy signal: result may be erroneous.

urn:iso:std:iso:11073:10101   197055 icon MDC_EVT_SIG_OUT_OF_RANGE

Definition for base term 3::446 MDC_EVT_SIG_OUT_OF_RANGE is: 1. Signal is out of range. 2. {SvO2} signal is out of range.

urn:iso:std:iso:11073:10101   197057 icon MDC_EVT_SIG_PROC_ERR

Definition for base term 3::448 MDC_EVT_SIG_PROC_ERR is: 1. Unspecified signal processing error 2. Unspecified signal processing error.

urn:iso:std:iso:11073:10101   196997 icon MDC_EVT_SIG_RANGE_OVER

Definition for base term 3::388 MDC_EVT_SIG_RANGE_OVER is: 1. Signal is overrange 2. Signal out of physical range.

urn:iso:std:iso:11073:10101   196999 icon MDC_EVT_SIG_RANGE_UNDER

Definition for base term 3::390 MDC_EVT_SIG_RANGE_UNDER is: 1. Signal is underrange 2. Signal out of range.

urn:iso:std:iso:11073:10101   197107 icon MDC_EVT_SIG_RATE_EQU

Definition for base term 3::498 MDC_EVT_SIG_RATE_EQU is: 1. Pulserate coincidence 2. Pulserate coincidence.

urn:iso:std:iso:11073:10101   197001 icon MDC_EVT_SIG_STRENGTH_WEAK

Definition for base term 3::392 MDC_EVT_SIG_STRENGTH_WEAK is: 1. Signal is weak 2. {SvO2} signal strength is weak.

urn:iso:std:iso:11073:10101   196993 icon MDC_EVT_SIG_UNANALYZEABLE

Definition for base term 3::384 MDC_EVT_SIG_UNANALYZEABLE is: 1. Error Event: Signal Cannot Be Analyzed (for any secondary derived measurement when the input signal is bad) 2. Error Event: Signal Cannot Be Analyzed (for any secondary derived measurement when the input signal is bad). [For example, {ECG QT} measurement is unanalyzable.]

urn:iso:std:iso:11073:10101   196929 icon MDC_EVT_SITE_TIMER_PROB

Definition for base term 3::320 MDC_EVT_SITE_TIMER_PROB is: 1. Site timer problem 2. Site Timer Problem.

urn:iso:std:iso:11073:10101   196783 icon MDC_EVT_SRC_ABSENT

Definition for base term 3::174 MDC_EVT_SRC_ABSENT is: 1. Error Event: Signal source absent 2. Source absent or missing.

urn:iso:std:iso:11073:10101   258049 icon MDC_EVT_STANDBY_WARN

Definition for base term 3::61440 MDC_EVT_STANDBY_WARN is: Warning that device will go to standy

urn:iso:std:iso:11073:10101   202807 icon MDC_EVT_STAT_ACTIVE

Definition for base term 3::6198 MDC_EVT_STAT_ACTIVE is: 1. Active state of, e.g., device 2. Active state of, e.g., device.

urn:iso:std:iso:11073:10101   202825 icon MDC_EVT_STAT_AL

Definition for base term 3::6216 MDC_EVT_STAT_AL is: 1. Alarm state of, e.g., device or signal 2. Alarm state of, e.g., device or signal.

urn:iso:std:iso:11073:10101   202753 icon MDC_EVT_STAT_AL_OFF

Definition for base term 3::6144 MDC_EVT_STAT_AL_OFF is: 1. Indication: Alarm Intentionally Off (disabled) 2. Indication: Alarm Intentionally Off (disabled). [This term is deprecated; use MDC_EVT_STAT_AIS_ALARM_OFF instead.]

urn:iso:std:iso:11073:10101   202755 icon MDC_EVT_STAT_AL_ON

Definition for base term 3::6146 MDC_EVT_STAT_AL_ON is: 1. Indication: Alarm Intentionally On (enabled) 2. Indication: Alarm Intentionally On (enabled). [This term is deprecated; use MDC_EVT_STAT_AIS_ENABLED instead.]

urn:iso:std:iso:11073:10101   202827 icon MDC_EVT_STAT_AL_PAUSED

Definition for base term 3::6218 MDC_EVT_STAT_AL_PAUSED is: 1. Indication: Alarm paused 2. Alarm is paused (visual and audio indications are off). [This term is deprecated; use MDC_EVT_STAT_AIS_ALARM_PAUSED instead.]

urn:iso:std:iso:11073:10101   202823 icon MDC_EVT_STAT_AL_SILENCE

Definition for base term 3::6214 MDC_EVT_STAT_AL_SILENCE is: 1. Alarm is silenced (speaker off). 2. Alarm is silenced (speaker off). [This term is deprecated; use MDC_EVT_STAT_AIS_AUDIO_OFF instead.]

urn:iso:std:iso:11073:10101   202839 icon MDC_EVT_STAT_AL_TACHAPNEA_DISABL

Definition for base term 3::6230 MDC_EVT_STAT_AL_TACHAPNEA_DISABL is: 1. Tachyapnea alarm is disabled. 2. Tachyapnea alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_TACHYPNEA_AIS_ALARM_OFF instead.]

urn:iso:std:iso:11073:10101   202883 icon MDC_EVT_STAT_APNEA_AL_DISABL

Definition for base term 3::6274 MDC_EVT_STAT_APNEA_AL_DISABL is: 1. Apnea alarm is disabled. 2. Apnea alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_APNEA_RELATED_AIS_ALARM_OFF instead.]

urn:iso:std:iso:11073:10101   202757 icon MDC_EVT_STAT_BACKUP_MODE

Definition for base term 3::6148 MDC_EVT_STAT_BACKUP_MODE is: 1. Indication: Device in Backup mode, No Measurement Possible 2. Status: Backup mode.

urn:iso:std:iso:11073:10101   202759 icon MDC_EVT_STAT_BATT_CHARGING

Definition for base term 3::6150 MDC_EVT_STAT_BATT_CHARGING is: Battery is now being recharged.

urn:iso:std:iso:11073:10101   202765 icon MDC_EVT_STAT_CALIB_INVIVO_RUNNING

Definition for base term 3::6156 MDC_EVT_STAT_CALIB_INVIVO_RUNNING is: 1. Indication: Calibration of invivo probe in Progress, No Measurement Possible 2. Status: Invivo Calibration running.

urn:iso:std:iso:11073:10101   202767 icon MDC_EVT_STAT_CALIB_LIGHT_RUNNING

Definition for base term 3::6158 MDC_EVT_STAT_CALIB_LIGHT_RUNNING is: 1. Indication: Calibration of light source in Progress, No Measurement Possible 2. Status: Light Calibration running.

urn:iso:std:iso:11073:10101   202761 icon MDC_EVT_STAT_CALIB_MODE

Definition for base term 3::6152 MDC_EVT_STAT_CALIB_MODE is: 1. Indication: Device in Calibration mode, No Measurement Possible 2. Calibration Mode or status [NOS].

urn:iso:std:iso:11073:10101   202769 icon MDC_EVT_STAT_CALIB_PREINS_RUNNING

Definition for base term 3::6160 MDC_EVT_STAT_CALIB_PREINS_RUNNING is: 1. Indication: Calibration of an optical (or other) sensor prior to insertion of a sensor/catheter 2. Status: Pre-insertion Calibration running.

urn:iso:std:iso:11073:10101   202763 icon MDC_EVT_STAT_CALIB_RUNNING

Definition for base term 3::6154 MDC_EVT_STAT_CALIB_RUNNING is: 1. Indication: Calibration in Progress, No Measurement Possible 2. {SpO2} Sensor calibrating

urn:iso:std:iso:11073:10101   202821 icon MDC_EVT_STAT_CHARGING

Definition for base term 3::6212 MDC_EVT_STAT_CHARGING is: 1. Charging state of, e.g., battery 2. Charging state of, e.g., battery.

urn:iso:std:iso:11073:10101   202879 icon MDC_EVT_STAT_CO2_AL_DISABL

Definition for base term 3::6270 MDC_EVT_STAT_CO2_AL_DISABL is: 1. Carbon dioxide alarm is disabled. 2. Carbon dioxide alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_CO2_AIS_ALARM_OFF instead.]

urn:iso:std:iso:11073:10101   202901 icon MDC_EVT_STAT_CO2_UNCALIB

Definition for base term 3::6292 MDC_EVT_STAT_CO2_UNCALIB is: 1. Carbon dioxide is not calibrated. 2. The airway CO2 monitor is not calibrated.

urn:iso:std:iso:11073:10101   202877 icon MDC_EVT_STAT_CO2_WARMING

Definition for base term 3::6268 MDC_EVT_STAT_CO2_WARMING is: 1. Carbon dioxide monitor in warm-up mode 2. The airway CO2 monitor in warm-up mode.

urn:iso:std:iso:11073:10101   202771 icon MDC_EVT_STAT_CONFIG

Definition for base term 3::6162 MDC_EVT_STAT_CONFIG is: 1. Indication: Configuration in Progress, No Measurement Possible 2. Status: Configuring {*}.

urn:iso:std:iso:11073:10101   202861 icon MDC_EVT_STAT_CONN

Definition for base term 3::6252 MDC_EVT_STAT_CONN is: 1. Connected state of device, sensor, etc. 2. Connected state of {*} device, sensor, etc.

urn:iso:std:iso:11073:10101   202857 icon MDC_EVT_STAT_DEPLET

Definition for base term 3::6248 MDC_EVT_STAT_DEPLET is: A sensor, absorber, etc., is depleted.

urn:iso:std:iso:11073:10101   202887 icon MDC_EVT_STAT_DEV

Definition for base term 3::6278 MDC_EVT_STAT_DEV is: 1. Report of functional status of device 2. Device (functional) status.

urn:iso:std:iso:11073:10101   202885 icon MDC_EVT_STAT_DEV_BATT_OPERATED

Definition for base term 3::6276 MDC_EVT_STAT_DEV_BATT_OPERATED is: Device is battery operated.

urn:iso:std:iso:11073:10101   202893 icon MDC_EVT_STAT_DEV_MAINS_OPERATED

Definition for base term 3::6284 MDC_EVT_STAT_DEV_MAINS_OPERATED is: Device is mains-operated.

urn:iso:std:iso:11073:10101   202891 icon MDC_EVT_STAT_DEV_MODE_ADULT

Definition for base term 3::6282 MDC_EVT_STAT_DEV_MODE_ADULT is: Device is in adult mode.

urn:iso:std:iso:11073:10101   202895 icon MDC_EVT_STAT_DEV_MODE_COMPUT_CNTRLD

Definition for base term 3::6286 MDC_EVT_STAT_DEV_MODE_COMPUT_CNTRLD is: Device, e.g., pump, is in computer-controlled mode.

urn:iso:std:iso:11073:10101   202889 icon MDC_EVT_STAT_DEV_MODE_PEDIATRIC

Definition for base term 3::6280 MDC_EVT_STAT_DEV_MODE_PEDIATRIC is: Device is in pediatric mode.

urn:iso:std:iso:11073:10101   202865 icon MDC_EVT_STAT_DISCONN

Definition for base term 3::6256 MDC_EVT_STAT_DISCONN is: Disconnection of a sensor, device, etc.

urn:iso:std:iso:11073:10101   196711 icon MDC_EVT_STAT_DISP_STOP

Definition for base term 3::102 MDC_EVT_STAT_DISP_STOP is: The display is stopped.

urn:iso:std:iso:11073:10101   202853 icon MDC_EVT_STAT_DOOR_CLOS

Definition for base term 3::6244 MDC_EVT_STAT_DOOR_CLOS is: 1. Door in the (sleep measurement) room is closed. 2. Door in the {sleep measurement} room is closed.

urn:iso:std:iso:11073:10101   202829 icon MDC_EVT_STAT_DOOR_OPEN

Definition for base term 3::6220 MDC_EVT_STAT_DOOR_OPEN is: 1. Door in the (sleep measurement) room is opened. 2. Door in the {sleep measurement} room is opened.

urn:iso:std:iso:11073:10101   202791 icon MDC_EVT_STAT_ECG_AL_ALL_OFF

Definition for base term 3::6182 MDC_EVT_STAT_ECG_AL_ALL_OFF is: Status: All ECG alarms are off (still need these in France to meet French homologation, despite MDD).

urn:iso:std:iso:11073:10101   202793 icon MDC_EVT_STAT_ECG_AL_SOME_OFF

Definition for base term 3::6184 MDC_EVT_STAT_ECG_AL_SOME_OFF is: Status: Some ECG alarms are off (still need these in France to meet French homologation, despite MDD).

urn:iso:std:iso:11073:10101   199707 icon MDC_EVT_STAT_ECG_PACING

Definition for base term 3::3098 MDC_EVT_STAT_ECG_PACING is: Pacer operational and controlling heart rhythm

urn:iso:std:iso:11073:10101   202833 icon MDC_EVT_STAT_LEARN

Definition for base term 3::6224 MDC_EVT_STAT_LEARN is: 1. Indication: Learning - analyzing waveform 2. The {ECG} signal processing algorithm is in the «learning» state.

urn:iso:std:iso:11073:10101   202869 icon MDC_EVT_STAT_LIGHTS_IN_ROOM_ON

Definition for base term 3::6260 MDC_EVT_STAT_LIGHTS_IN_ROOM_ON is: 1. Lights in the (sleep measurement) room are switched on. 2. Lights in the {sleep measurement} room are switched on.

urn:iso:std:iso:11073:10101   202797 icon MDC_EVT_STAT_MODE_SIGH_ACTIVE

Definition for base term 3::6188 MDC_EVT_STAT_MODE_SIGH_ACTIVE is: Sigh mode is active.

urn:iso:std:iso:11073:10101   202841 icon MDC_EVT_STAT_MODE_TEST

Definition for base term 3::6232 MDC_EVT_STAT_MODE_TEST is: Device or VMD is in test mode.

urn:iso:std:iso:11073:10101   202859 icon MDC_EVT_STAT_NBP_DEFL_AND_MEAS_BP

Definition for base term 3::6250 MDC_EVT_STAT_NBP_DEFL_AND_MEAS_BP is: 1. NIBP is deflating cuff and measuring blood pressure. 2. Noninvasive blood pressure device is deflating cuff and measuring blood pressure.

urn:iso:std:iso:11073:10101   202831 icon MDC_EVT_STAT_NBP_INFL_TO_MAX_CUFF_PRESS

Definition for base term 3::6222 MDC_EVT_STAT_NBP_INFL_TO_MAX_CUFF_PRESS is: 1. NIBP is inflating cuff to maximum cuff pressure. 2. Noninvasive blood pressure device is inflating cuff to maximum cuff pressure.

urn:iso:std:iso:11073:10101   202835 icon MDC_EVT_STAT_OFF

Definition for base term 3::6226 MDC_EVT_STAT_OFF is: 1. Device or VMD is in off condition. 2. Off (e.g. device or VMD is in an off condition)

urn:iso:std:iso:11073:10101   202875 icon MDC_EVT_STAT_ON

Definition for base term 3::6266 MDC_EVT_STAT_ON is: 1. Device or VMD is in on condition 2. On (e.g. device or VMD is in an on condition)

urn:iso:std:iso:11073:10101   202781 icon MDC_EVT_STAT_OPT_MOD_SENSOR_CONN

Definition for base term 3::6172 MDC_EVT_STAT_OPT_MOD_SENSOR_CONN is: 1. Indication: Optical sensor connected 2. Status: {SvO2} optical module connected.

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

Lvl A few code lists that FHIR defines are hierarchical - each code is assigned a level. For value sets, levels are mostly used to organize codes for user convenience, but may follow code system hierarchy - see Code System for further information
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code