This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions 
Responsible Owner: Health Care Devices Work Group |
Normative | Use Context: Country: World |
Official URL: http://hl7.org/fhir/ValueSet/devicealert-condition
|
Version: 6.0.0-ballot4 | |||
| active as of 2026-03-18 | Computable Name: DeviceAlertConditionCodes | |||
| Flags: | OID: | |||
This value set is used in the following places:
DeviceAlert Condition Codes
Generated Narrative: ValueSet devicealert-condition
Last updated: 2026-03-18T20:20:28.343Z
urn:iso:std:iso:11073:10101
version ⏿2024-12-05 where partition = 3 
This expansion generated 18 Mar 2026
ValueSet
Expansion from tx.fhir.org based on codesystem MDC Nomenclature v2024-12-05 (CodeSystem) 
This value set has >1000 codes in it. In order to keep the publication size manageable, only a selection (1000 codes) of the whole set of codes is shown
| System | Code | Display | Definition |
urn:iso:std:iso:11073:10101 |
196608 ![]() |
MDC_EVT |
|
urn:iso:std:iso:11073:10101 |
196610 ![]() |
MDC_EVT_ABNORM |
|
urn:iso:std:iso:11073:10101 |
196612 ![]() |
MDC_EVT_ABSENT |
|
urn:iso:std:iso:11073:10101 |
196614 ![]() |
MDC_EVT_ACTIVE | Active (NOS) |
urn:iso:std:iso:11073:10101 |
196616 ![]() |
MDC_EVT_ALARM |
|
urn:iso:std:iso:11073:10101 |
196620 ![]() |
MDC_EVT_CONN | Connection |
urn:iso:std:iso:11073:10101 |
196622 ![]() |
MDC_EVT_CONTAM | Contaminated |
urn:iso:std:iso:11073:10101 |
196624 ![]() |
MDC_EVT_DEFECT | Defect is detected in a device, sensor, etc. |
urn:iso:std:iso:11073:10101 |
196626 ![]() |
MDC_EVT_DEPLET | An agent is detected as depleted in a device, sensor, etc |
urn:iso:std:iso:11073:10101 |
196628 ![]() |
MDC_EVT_DETEC | Some signal or special condition was detected. |
urn:iso:std:iso:11073:10101 |
196630 ![]() |
MDC_EVT_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196632 ![]() |
MDC_EVT_DISTURB |
|
urn:iso:std:iso:11073:10101 |
196634 ![]() |
MDC_EVT_EMPTY | A reservoir, etc., is empty. |
urn:iso:std:iso:11073:10101 |
196636 ![]() |
MDC_EVT_EQU |
|
urn:iso:std:iso:11073:10101 |
196638 ![]() |
MDC_EVT_ERR |
|
urn:iso:std:iso:11073:10101 |
196640 ![]() |
MDC_EVT_ERRATIC | Erratic condition is detected. |
urn:iso:std:iso:11073:10101 |
196642 ![]() |
MDC_EVT_EXCESS |
|
urn:iso:std:iso:11073:10101 |
196644 ![]() |
MDC_EVT_EXH |
|
urn:iso:std:iso:11073:10101 |
196646 ![]() |
MDC_EVT_FAIL | An action, data transmission, etc., failed. |
urn:iso:std:iso:11073:10101 |
196648 ![]() |
MDC_EVT_HI | {numeric observation} > high limit |
urn:iso:std:iso:11073:10101 |
196650 ![]() |
MDC_EVT_HI_GT_LIM | A metric exceeds a given threshold |
urn:iso:std:iso:11073:10101 |
196652 ![]() |
MDC_EVT_HI_VAL_GT_LIM | A metric exceeds a given threshold. |
urn:iso:std:iso:11073:10101 |
196654 ![]() |
MDC_EVT_INCORRECT |
|
urn:iso:std:iso:11073:10101 |
196656 ![]() |
MDC_EVT_INFILT |
|
urn:iso:std:iso:11073:10101 |
196658 ![]() |
MDC_EVT_INGRESS |
|
urn:iso:std:iso:11073:10101 |
196660 ![]() |
MDC_EVT_INOP |
|
urn:iso:std:iso:11073:10101 |
196662 ![]() |
MDC_EVT_INTERF |
|
urn:iso:std:iso:11073:10101 |
196664 ![]() |
MDC_EVT_INTERRUP | A measurement, process, or data transmission was interrupted. |
urn:iso:std:iso:11073:10101 |
196666 ![]() |
MDC_EVT_IRREG | Irregular rhythm or waveform in a signal, etc. |
urn:iso:std:iso:11073:10101 |
196668 ![]() |
MDC_EVT_LEAK |
|
urn:iso:std:iso:11073:10101 |
196670 ![]() |
MDC_EVT_LO | {numeric observation} < low limit |
urn:iso:std:iso:11073:10101 |
196672 ![]() |
MDC_EVT_LO_LT_LIM | A metric falls short of a given threshold |
urn:iso:std:iso:11073:10101 |
196674 ![]() |
MDC_EVT_LO_VAL_LT_LIM | A metric falls short of a given threshold. |
urn:iso:std:iso:11073:10101 |
196676 ![]() |
MDC_EVT_LOST | Signal or synchronization, etc., was lost. |
urn:iso:std:iso:11073:10101 |
196678 ![]() |
MDC_EVT_MALF |
|
urn:iso:std:iso:11073:10101 |
196680 ![]() |
MDC_EVT_MODE |
|
urn:iso:std:iso:11073:10101 |
196682 ![]() |
MDC_EVT_NOISY | Signal is noisy. |
urn:iso:std:iso:11073:10101 |
196686 ![]() |
MDC_EVT_NOT_DEFLATED |
|
urn:iso:std:iso:11073:10101 |
196688 ![]() |
MDC_EVT_OBSTRUC | Flow is hindered. |
urn:iso:std:iso:11073:10101 |
196696 ![]() |
MDC_EVT_OVER | Overflow was detected in a measurement or calculation |
urn:iso:std:iso:11073:10101 |
196698 ![]() |
MDC_EVT_OVERFLOW | Overflow was detected in a measurement or calculation. |
urn:iso:std:iso:11073:10101 |
196700 ![]() |
MDC_EVT_PROB |
|
urn:iso:std:iso:11073:10101 |
196704 ![]() |
MDC_EVT_REVERSED | Flow is reversed |
urn:iso:std:iso:11073:10101 |
196708 ![]() |
MDC_EVT_SHORT |
|
urn:iso:std:iso:11073:10101 |
196710 ![]() |
MDC_EVT_STAT_DISP_STOP | The display is stopped. |
urn:iso:std:iso:11073:10101 |
196712 ![]() |
MDC_EVT_SUBATMOS |
|
urn:iso:std:iso:11073:10101 |
196714 ![]() |
MDC_EVT_SUST |
|
urn:iso:std:iso:11073:10101 |
196716 ![]() |
MDC_EVT_UNANALYZEABLE |
|
urn:iso:std:iso:11073:10101 |
196718 ![]() |
MDC_EVT_UNAVAIL | Resource is unavailable. |
urn:iso:std:iso:11073:10101 |
196720 ![]() |
MDC_EVT_UNDEF | Undefined. |
urn:iso:std:iso:11073:10101 |
196722 ![]() |
MDC_EVT_UNDER | Underflow was detected in a measurement or calculation |
urn:iso:std:iso:11073:10101 |
196724 ![]() |
MDC_EVT_UNEQU |
|
urn:iso:std:iso:11073:10101 |
196726 ![]() |
MDC_EVT_UNK | VMD or signal is unknown. |
urn:iso:std:iso:11073:10101 |
196728 ![]() |
MDC_EVT_UNPLUGGED |
|
urn:iso:std:iso:11073:10101 |
196730 ![]() |
MDC_EVT_VIOL |
|
urn:iso:std:iso:11073:10101 |
196732 ![]() |
MDC_EVT_WARMING |
|
urn:iso:std:iso:11073:10101 |
196734 ![]() |
MDC_EVT_WARN |
|
urn:iso:std:iso:11073:10101 |
196736 ![]() |
MDC_EVT_WEAK | Weak signal was detected. |
urn:iso:std:iso:11073:10101 |
196738 ![]() |
MDC_EVT_RECOV_ERR |
|
urn:iso:std:iso:11073:10101 |
196740 ![]() |
MDC_EVT_UNINTEN_INOP |
|
urn:iso:std:iso:11073:10101 |
196742 ![]() |
MDC_EVT_UNRECOV_ERR |
|
urn:iso:std:iso:11073:10101 |
196744 ![]() |
MDC_EVT_BREATH_ABSENT |
|
urn:iso:std:iso:11073:10101 |
196746 ![]() |
MDC_EVT_CALIB_FAIL |
|
urn:iso:std:iso:11073:10101 |
196748 ![]() |
MDC_EVT_COMM_LOST |
|
urn:iso:std:iso:11073:10101 |
196750 ![]() |
MDC_EVT_CONFIG_ERR |
|
urn:iso:std:iso:11073:10101 |
196752 ![]() |
MDC_EVT_DATA_ACQN_PROB | Unspecified problem in data acquisition |
urn:iso:std:iso:11073:10101 |
196754 ![]() |
MDC_EVT_FUNC_UNAVAIL | A resource is not available. |
urn:iso:std:iso:11073:10101 |
196756 ![]() |
MDC_EVT_GAIN_HI |
|
urn:iso:std:iso:11073:10101 |
196758 ![]() |
MDC_EVT_GAIN_LO |
|
urn:iso:std:iso:11073:10101 |
196760 ![]() |
MDC_EVT_HANDL_ERR |
|
urn:iso:std:iso:11073:10101 |
196762 ![]() |
MDC_EVT_INFLAT_OVER |
|
urn:iso:std:iso:11073:10101 |
196764 ![]() |
MDC_EVT_MIX_ERR |
|
urn:iso:std:iso:11073:10101 |
196766 ![]() |
MDC_EVT_POSN_IRREG |
|
urn:iso:std:iso:11073:10101 |
196768 ![]() |
MDC_EVT_POSN_PROB |
|
urn:iso:std:iso:11073:10101 |
196770 ![]() |
MDC_EVT_PROC_ERR |
|
urn:iso:std:iso:11073:10101 |
196772 ![]() |
MDC_EVT_RANGE_ERR |
|
urn:iso:std:iso:11073:10101 |
196774 ![]() |
MDC_EVT_RANGE_OVER |
|
urn:iso:std:iso:11073:10101 |
196776 ![]() |
MDC_EVT_RANGE_UNDER |
|
urn:iso:std:iso:11073:10101 |
196778 ![]() |
MDC_EVT_SHAPE_ERR | [Pattern] Shape error. |
urn:iso:std:iso:11073:10101 |
196780 ![]() |
MDC_EVT_SIG_ERRATIC | Error Event: Signal erratic |
urn:iso:std:iso:11073:10101 |
196782 ![]() |
MDC_EVT_SRC_ABSENT |
|
urn:iso:std:iso:11073:10101 |
196784 ![]() |
MDC_EVT_SUPPLY_LO |
|
urn:iso:std:iso:11073:10101 |
196786 ![]() |
MDC_EVT_SUPPLY_PROB |
|
urn:iso:std:iso:11073:10101 |
196788 ![]() |
MDC_EVT_SVC_QUALITY |
|
urn:iso:std:iso:11073:10101 |
196790 ![]() |
MDC_EVT_SYNCH_ERR |
|
urn:iso:std:iso:11073:10101 |
196792 ![]() |
MDC_EVT_SYNCH_INOP | Synchronisation inoperable |
urn:iso:std:iso:11073:10101 |
196794 ![]() |
MDC_EVT_TIMEOUT_ERR |
|
urn:iso:std:iso:11073:10101 |
196796 ![]() |
MDC_EVT_VIB_PROB | Vibration hinders adequate measurement. |
urn:iso:std:iso:11073:10101 |
196798 ![]() |
MDC_EVT_WEDGE_OCCL |
|
urn:iso:std:iso:11073:10101 |
196800 ![]() |
MDC_EVT_BATT_FAIL |
|
urn:iso:std:iso:11073:10101 |
196802 ![]() |
MDC_EVT_BATT_LO |
|
urn:iso:std:iso:11073:10101 |
196804 ![]() |
MDC_EVT_BATT_MALF | Battery malfunction |
urn:iso:std:iso:11073:10101 |
196806 ![]() |
MDC_EVT_BATT_PROB | Unspecified battery problem |
urn:iso:std:iso:11073:10101 |
196808 ![]() |
MDC_EVT_VENT_OCCL |
|
urn:iso:std:iso:11073:10101 |
196810 ![]() |
MDC_EVT_BUFF_OVERFLO | Use MDC_EVT_BUFF_OVERFLOW (3::502) |
urn:iso:std:iso:11073:10101 |
196812 ![]() |
MDC_EVT_CABLE_SHORT |
|
urn:iso:std:iso:11073:10101 |
196814 ![]() |
MDC_EVT_CATH_PULM_INFLAT_OVER |
|
urn:iso:std:iso:11073:10101 |
196816 ![]() |
MDC_EVT_CKT_SHORT | A short circuit was detected in a VMD. |
urn:iso:std:iso:11073:10101 |
196818 ![]() |
MDC_EVT_VENT_EXH |
|
urn:iso:std:iso:11073:10101 |
196820 ![]() |
MDC_EVT_CO2_CAN_LEAK |
|
urn:iso:std:iso:11073:10101 |
196822 ![]() |
MDC_EVT_CO2_SAMPL_LINE_DEFECT | Defect occurred in a CO2 sample line |
urn:iso:std:iso:11073:10101 |
196824 ![]() |
MDC_EVT_CO2_WIND_OBSTRUC |
|
urn:iso:std:iso:11073:10101 |
196826 ![]() |
MDC_EVT_COMM_LINK_NOISY |
|
urn:iso:std:iso:11073:10101 |
196828 ![]() |
MDC_EVT_COMM_MODULE_ERR |
|
urn:iso:std:iso:11073:10101 |
196830 ![]() |
MDC_EVT_COMPONENT_POSN_PROB |
|
urn:iso:std:iso:11073:10101 |
196832 ![]() |
MDC_EVT_CONNECTOR_SHORT |
|
urn:iso:std:iso:11073:10101 |
196834 ![]() |
MDC_EVT_CUFF_INCORRECT |
|
urn:iso:std:iso:11073:10101 |
196836 ![]() |
MDC_EVT_CUFF_LEAK | Cuff leak |
urn:iso:std:iso:11073:10101 |
196838 ![]() |
MDC_EVT_CUFF_NOT_DEFLATED |
|
urn:iso:std:iso:11073:10101 |
196840 ![]() |
MDC_EVT_CUFF_INFLAT_OVER |
|
urn:iso:std:iso:11073:10101 |
196842 ![]() |
MDC_EVT_DOOR_OR_HANDLE_POSN_PROB | A door or handle which must be closed for proper operation is open. |
urn:iso:std:iso:11073:10101 |
196844 ![]() |
MDC_EVT_ELEC_PWR_LINE_PROB |
|
urn:iso:std:iso:11073:10101 |
196846 ![]() |
MDC_EVT_ENDOTRACH_TUBE_LEAK |
|
urn:iso:std:iso:11073:10101 |
196850 ![]() |
MDC_EVT_EQUIP_MALF |
|
urn:iso:std:iso:11073:10101 |
196852 ![]() |
MDC_EVT_FLUID_LINE_DISTURB |
|
urn:iso:std:iso:11073:10101 |
196854 ![]() |
MDC_EVT_FLUID_LINE_INFILT |
|
urn:iso:std:iso:11073:10101 |
196856 ![]() |
MDC_EVT_FLUID_LINE_INGRESS |
|
urn:iso:std:iso:11073:10101 |
196858 ![]() |
MDC_EVT_TUBE_OCCL |
|
urn:iso:std:iso:11073:10101 |
196860 ![]() |
MDC_EVT_FLUID_LINE_PROB |
|
urn:iso:std:iso:11073:10101 |
196862 ![]() |
MDC_EVT_FLUID_LINE_FLOW_SENSOR_PROB |
|
urn:iso:std:iso:11073:10101 |
196864 ![]() |
MDC_EVT_GAS_CONTAM | Gas contamination |
urn:iso:std:iso:11073:10101 |
196866 ![]() |
MDC_EVT_GAS_AGENT_IDENT_MALF |
|
urn:iso:std:iso:11073:10101 |
196868 ![]() |
MDC_EVT_GAS_LINE_PROB |
|
urn:iso:std:iso:11073:10101 |
196870 ![]() |
MDC_EVT_HEATING_PWR_PROB |
|
urn:iso:std:iso:11073:10101 |
196872 ![]() |
MDC_EVT_HOSE_LEAK |
|
urn:iso:std:iso:11073:10101 |
196874 ![]() |
MDC_EVT_HOSE_OBSTRUC |
|
urn:iso:std:iso:11073:10101 |
196876 ![]() |
MDC_EVT_LEAD_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196878 ![]() |
MDC_EVT_LEAD_NOISY |
|
urn:iso:std:iso:11073:10101 |
196880 ![]() |
MDC_EVT_LEAD_OFF |
|
urn:iso:std:iso:11073:10101 |
196882 ![]() |
MDC_EVT_LEADS_OFF |
|
urn:iso:std:iso:11073:10101 |
196884 ![]() |
MDC_EVT_LIGHTS_IN_ROOM_OFF |
|
urn:iso:std:iso:11073:10101 |
196886 ![]() |
MDC_EVT_LIGHT_INTERF |
|
urn:iso:std:iso:11073:10101 |
196888 ![]() |
MDC_EVT_LIGHT_SRC_ABSENT |
|
urn:iso:std:iso:11073:10101 |
196890 ![]() |
MDC_EVT_MED_GAS_SUPPLY_LO |
|
urn:iso:std:iso:11073:10101 |
196892 ![]() |
MDC_EVT_MODULE_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196894 ![]() |
MDC_EVT_MODULE_EXCESS |
|
urn:iso:std:iso:11073:10101 |
196896 ![]() |
MDC_EVT_MODULE_UNK |
|
urn:iso:std:iso:11073:10101 |
196898 ![]() |
MDC_EVT_MS_SUBSYS_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196900 ![]() |
MDC_EVT_MSG_COMM_ERR |
|
urn:iso:std:iso:11073:10101 |
196904 ![]() |
MDC_EVT_O2_SUPPLY_LO |
|
urn:iso:std:iso:11073:10101 |
196906 ![]() |
MDC_EVT_OPTIC_MODULE_ABSENT |
|
urn:iso:std:iso:11073:10101 |
196908 ![]() |
MDC_EVT_OPTIC_MODULE_DEFECT |
|
urn:iso:std:iso:11073:10101 |
196910 ![]() |
MDC_EVT_PAPER_PROB |
|
urn:iso:std:iso:11073:10101 |
196912 ![]() |
MDC_EVT_PLUGIN_INCORRECT |
|
urn:iso:std:iso:11073:10101 |
196914 ![]() |
MDC_EVT_PLUGIN_POSN_IRREG | Problem in position of a plug-in device |
urn:iso:std:iso:11073:10101 |
196916 ![]() |
MDC_EVT_SENSOR_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196918 ![]() |
MDC_EVT_SENSOR_MALF |
|
urn:iso:std:iso:11073:10101 |
196920 ![]() |
MDC_EVT_SENSOR_PROB |
|
urn:iso:std:iso:11073:10101 |
196922 ![]() |
MDC_EVT_SIDESTRM_MALF |
|
urn:iso:std:iso:11073:10101 |
196924 ![]() |
MDC_EVT_SIDESTRM_OFF |
|
urn:iso:std:iso:11073:10101 |
196926 ![]() |
MDC_EVT_SIDESTRM_ON |
|
urn:iso:std:iso:11073:10101 |
196928 ![]() |
MDC_EVT_SITE_TIMER_PROB |
|
urn:iso:std:iso:11073:10101 |
196930 ![]() |
MDC_EVT_SW_VER_UNK |
|
urn:iso:std:iso:11073:10101 |
196934 ![]() |
MDC_EVT_TUBE_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196936 ![]() |
MDC_EVT_TUBE_LEAK |
|
urn:iso:std:iso:11073:10101 |
196938 ![]() |
MDC_EVT_TUBE_OBSTRUC |
|
urn:iso:std:iso:11073:10101 |
196940 ![]() |
MDC_EVT_FLUID_LINE_OCCL | Occlusion of fluid line. |
urn:iso:std:iso:11073:10101 |
196942 ![]() |
MDC_EVT_XDUCR_ABSENT |
|
urn:iso:std:iso:11073:10101 |
196944 ![]() |
MDC_EVT_XDUCR_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196946 ![]() |
MDC_EVT_XDUCR_MALF |
|
urn:iso:std:iso:11073:10101 |
196948 ![]() |
MDC_EVT_BW_INCORRECT |
|
urn:iso:std:iso:11073:10101 |
196950 ![]() |
MDC_EVT_FLOW_LO |
|
urn:iso:std:iso:11073:10101 |
196952 ![]() |
MDC_EVT_FLOW_REVERSED |
|
urn:iso:std:iso:11073:10101 |
196954 ![]() |
MDC_EVT_FLUID_LINE_DRIP_MALF |
|
urn:iso:std:iso:11073:10101 |
196956 ![]() |
MDC_EVT_INTENS_ERR |
|
urn:iso:std:iso:11073:10101 |
196958 ![]() |
MDC_EVT_INTENS_LIGHT_ERR |
|
urn:iso:std:iso:11073:10101 |
196960 ![]() |
MDC_EVT_MSMT_DISCONN |
|
urn:iso:std:iso:11073:10101 |
196962 ![]() |
MDC_EVT_MSMT_ERR |
|
urn:iso:std:iso:11073:10101 |
196964 ![]() |
MDC_EVT_MSMT_FAIL |
|
urn:iso:std:iso:11073:10101 |
196966 ![]() |
MDC_EVT_MSMT_INOP |
|
urn:iso:std:iso:11073:10101 |
196968 ![]() |
MDC_EVT_MSMT_INTERF |
|
urn:iso:std:iso:11073:10101 |
196970 ![]() |
MDC_EVT_MSMT_INTERRUP | Error Event: Measurement Interrupted (e.g., a noninvasive blood pressure) (there is a generic interrupted code for processing; however, this code does not have to do with processing. As an example of this code, the user might simply hit a stop button, and this action makes the measurement invalid.) |
urn:iso:std:iso:11073:10101 |
196972 ![]() |
MDC_EVT_MSMT_RANGE_OVER |
|
urn:iso:std:iso:11073:10101 |
196974 ![]() |
MDC_EVT_MSMT_RANGE_UNDER |
|
urn:iso:std:iso:11073:10101 |
196976 ![]() |
MDC_EVT_PRESS_HI_GT_LIM | High pressure |
urn:iso:std:iso:11073:10101 |
196978 ![]() |
MDC_EVT_PRESS_HI_VAL_GT_LIM | High pressure |
urn:iso:std:iso:11073:10101 |
196980 ![]() |
MDC_EVT_PRESS_SUBATMOS |
|
urn:iso:std:iso:11073:10101 |
196982 ![]() |
MDC_EVT_PRESS_SUPPLY_HI |
|
urn:iso:std:iso:11073:10101 |
196984 ![]() |
MDC_EVT_PRESS_SUPPLY_LO |
|
urn:iso:std:iso:11073:10101 |
196986 ![]() |
MDC_EVT_PRESS_CUFF_OVER |
|
urn:iso:std:iso:11073:10101 |
196988 ![]() |
MDC_EVT_SIG_LO |
|
urn:iso:std:iso:11073:10101 |
196992 ![]() |
MDC_EVT_SIG_UNANALYZEABLE |
|
urn:iso:std:iso:11073:10101 |
196996 ![]() |
MDC_EVT_SIG_RANGE_OVER |
|
urn:iso:std:iso:11073:10101 |
196998 ![]() |
MDC_EVT_SIG_RANGE_UNDER |
|
urn:iso:std:iso:11073:10101 |
197000 ![]() |
MDC_EVT_SIG_STRENGTH_WEAK |
|
urn:iso:std:iso:11073:10101 |
197002 ![]() |
MDC_EVT_TEMP_HI_GT_LIM |
|
urn:iso:std:iso:11073:10101 |
197004 ![]() |
MDC_EVT_TEMP_HI_VAL_GT_LIM |
|
urn:iso:std:iso:11073:10101 |
197006 ![]() |
MDC_EVT_UNIT_INVALID |
|
urn:iso:std:iso:11073:10101 |
197008 ![]() |
MDC_EVT_UNSUPPORTED |
|
urn:iso:std:iso:11073:10101 |
197010 ![]() |
MDC_EVT_MSG_NOM_ERR | A message contains wrong code. |
urn:iso:std:iso:11073:10101 |
197012 ![]() |
MDC_EVT_SIG_GAIN_LO |
|
urn:iso:std:iso:11073:10101 |
197014 ![]() |
MDC_EVT_OP_INVALID |
|
urn:iso:std:iso:11073:10101 |
197016 ![]() |
MDC_EVT_MATERIAL_LOW_OR_OUT | Unspecified tools or agents (e.g., calibration fluids) are low. |
urn:iso:std:iso:11073:10101 |
197018 ![]() |
MDC_EVT_AL_LIMIT |
|
urn:iso:std:iso:11073:10101 |
197020 ![]() |
MDC_EVT_QOS |
|
urn:iso:std:iso:11073:10101 |
197022 ![]() |
MDC_EVT_TIMING |
|
urn:iso:std:iso:11073:10101 |
197024 ![]() |
MDC_EVT_MSG_ERR_PROC |
|
urn:iso:std:iso:11073:10101 |
197026 ![]() |
MDC_EVT_COMPUT_UNDERFLOW | Underflow was detected in a measurement or calculation. |
urn:iso:std:iso:11073:10101 |
197028 ![]() |
MDC_EVT_PROC |
|
urn:iso:std:iso:11073:10101 |
197030 ![]() |
MDC_EVT_VENT_DELIV_O2_LO |
|
urn:iso:std:iso:11073:10101 |
197034 ![]() |
MDC_EVT_SYNCH |
|
urn:iso:std:iso:11073:10101 |
197038 ![]() |
MDC_EVT_CUFF_POSN_ERR |
|
urn:iso:std:iso:11073:10101 |
197040 ![]() |
MDC_EVT_WAVE_ARTIF_ERR |
|
urn:iso:std:iso:11073:10101 |
197042 ![]() |
MDC_EVT_WAVE_SIG_QUAL_ERR | Disturbed waveform: result may be erroneous. |
urn:iso:std:iso:11073:10101 |
197044 ![]() |
MDC_EVT_MSMT_INTERF_ERR |
|
urn:iso:std:iso:11073:10101 |
197046 ![]() |
MDC_EVT_WAVE_SHAPE_ABNORM | Shape/amplitude of waveform is abnormal. |
urn:iso:std:iso:11073:10101 |
197048 ![]() |
MDC_EVT_SIG_NOISY | Noisy signal: result may be erroneous. |
urn:iso:std:iso:11073:10101 |
197050 ![]() |
MDC_EVT_WAVE_OSCIL_ABSENT | Oscillation in waveform is expected, but not found. |
urn:iso:std:iso:11073:10101 |
197052 ![]() |
MDC_EVT_SIG_ABSENT |
|
urn:iso:std:iso:11073:10101 |
197054 ![]() |
MDC_EVT_SIG_OUT_OF_RANGE |
|
urn:iso:std:iso:11073:10101 |
197056 ![]() |
MDC_EVT_SIG_PROC_ERR |
|
urn:iso:std:iso:11073:10101 |
197058 ![]() |
MDC_EVT_LIMIT_AL_HI | A metric exceeds a given threshold. |
urn:iso:std:iso:11073:10101 |
197060 ![]() |
MDC_EVT_MSG_CORRUPT | Subsystem has received false data packet. |
urn:iso:std:iso:11073:10101 |
197062 ![]() |
MDC_EVT_NBP_MOTION_DETEC |
|
urn:iso:std:iso:11073:10101 |
197064 ![]() |
MDC_EVT_NBP_CUFF_DISCONN_OR_LEAK |
|
urn:iso:std:iso:11073:10101 |
197066 ![]() |
MDC_EVT_POWER_SUPPLY_PROB |
|
urn:iso:std:iso:11073:10101 |
197068 ![]() |
MDC_EVT_VOLTAGE_OUT_OF_RANGE | Signal voltage is out of range. |
urn:iso:std:iso:11073:10101 |
197070 ![]() |
MDC_EVT_CO2_MSMT_FAIL |
|
urn:iso:std:iso:11073:10101 |
197072 ![]() |
MDC_EVT_CO2_SENSOR_FAIL |
|
urn:iso:std:iso:11073:10101 |
197074 ![]() |
MDC_EVT_VENT_CYC_INSP_START |
|
urn:iso:std:iso:11073:10101 |
197076 ![]() |
MDC_EVT_COMM |
|
urn:iso:std:iso:11073:10101 |
197078 ![]() |
MDC_EVT_MSG_SEMAN_ERR | Subsystem has received false data packet. |
urn:iso:std:iso:11073:10101 |
197080 ![]() |
MDC_EVT_FRAM_ERR |
|
urn:iso:std:iso:11073:10101 |
197082 ![]() |
MDC_EVT_PARITY_ERR |
|
urn:iso:std:iso:11073:10101 |
197084 ![]() |
MDC_EVT_DOOR_POSN_ERR |
|
urn:iso:std:iso:11073:10101 |
197086 ![]() |
MDC_EVT_MSG_SYNTAX_UNDEF |
|
urn:iso:std:iso:11073:10101 |
197088 ![]() |
MDC_EVT_TIMER_SYNCH_TICK |
|
urn:iso:std:iso:11073:10101 |
197090 ![]() |
MDC_EVT_DATA_ACQN_ERR |
|
urn:iso:std:iso:11073:10101 |
197092 ![]() |
MDC_EVT_LIGHT_ON |
|
urn:iso:std:iso:11073:10101 |
197094 ![]() |
MDC_EVT_TEMP_ENVIRON_LOW_ABNORM |
|
urn:iso:std:iso:11073:10101 |
197096 ![]() |
MDC_EVT_TEMP_ENVIRON_HI_ABNORM |
|
urn:iso:std:iso:11073:10101 |
197098 ![]() |
MDC_EVT_HUMID_EXCESS |
|
urn:iso:std:iso:11073:10101 |
197102 ![]() |
MDC_EVT_SIG_ABSENT_OSCIL |
|
urn:iso:std:iso:11073:10101 |
197104 ![]() |
MDC_EVT_SIG_AMPL_INVALID |
|
urn:iso:std:iso:11073:10101 |
197106 ![]() |
MDC_EVT_SIG_RATE_EQU |
|
urn:iso:std:iso:11073:10101 |
197108 ![]() |
MDC_EVT_SIG_ARTIFACT |
|
urn:iso:std:iso:11073:10101 |
197110 ![]() |
MDC_EVT_BUFF_OVERFLOW |
|
urn:iso:std:iso:11073:10101 |
197112 ![]() |
MDC_EVT_VENT_TEMP_AWAY_HI | Airway temperature is too high (ventilator). |
urn:iso:std:iso:11073:10101 |
197114 ![]() |
MDC_EVT_TEMP_ERR_ENVIRON |
|
urn:iso:std:iso:11073:10101 |
197116 ![]() |
MDC_EVT_VENT_ENDOTRACH_TUBE_OBSTRUC |
|
urn:iso:std:iso:11073:10101 |
197118 ![]() |
MDC_EVT_VENT_VOL_BREATHING_IRREG | Breathing volume is not constant. |
urn:iso:std:iso:11073:10101 |
197120 ![]() |
MDC_EVT_VENT_VOL_MSMT_INOP | The volume measurement in a ventilator is inoperable. |
urn:iso:std:iso:11073:10101 |
197122 ![]() |
MDC_EVT_RESPIRATOR_TEMP_HI | Respirator device temperature is too high. |
urn:iso:std:iso:11073:10101 |
197124 ![]() |
MDC_EVT_VENT_GAS_AGENT_NOT_SELECTED | The gas agent must be selected for it to be measured by the airway gas analyzer. |
urn:iso:std:iso:11073:10101 |
197126 ![]() |
MDC_EVT_VENT_SYNCH_INOP |
|
urn:iso:std:iso:11073:10101 |
197128 ![]() |
MDC_EVT_FLOW_DISTURB |
|
urn:iso:std:iso:11073:10101 |
197130 ![]() |
MDC_EVT_VENT_EXP_VALVE_STUCK |
|
urn:iso:std:iso:11073:10101 |
197132 ![]() |
MDC_EVT_TIME_PD_DELIV_COMP |
|
urn:iso:std:iso:11073:10101 |
197134 ![]() |
MDC_EVT_DEV_STAT_RPT | Device status report. |
urn:iso:std:iso:11073:10101 |
197136 ![]() |
MDC_EVT_VENT_MIX_IRIS_INOP | Gaseous agent mixing iris is inoperable in a ventilator (anesthesia). |
urn:iso:std:iso:11073:10101 |
197138 ![]() |
MDC_EVT_TIME_PD_STANDBY_COMP |
|
urn:iso:std:iso:11073:10101 |
197140 ![]() |
MDC_EVT_VENT_BREATHING_SYS_VENTED | Breathing system is vented. |
urn:iso:std:iso:11073:10101 |
197142 ![]() |
MDC_EVT_VENT_CO2_ABSORB_EXH |
|
urn:iso:std:iso:11073:10101 |
197144 ![]() |
MDC_EVT_VENT_CO2_SENSOR_LINE_OBSTRUC | The airway CO2 gas sampling line is blocked. |
urn:iso:std:iso:11073:10101 |
197146 ![]() |
MDC_EVT_VENT_ENDOTRACH_TUBE_OCCL |
|
urn:iso:std:iso:11073:10101 |
197148 ![]() |
MDC_EVT_VENT_TEMP_HI | Ventilator device temperature is too high. |
urn:iso:std:iso:11073:10101 |
197150 ![]() |
MDC_EVT_VENT_COMPONENT_DISCONN |
|
urn:iso:std:iso:11073:10101 |
197154 ![]() |
MDC_EVT_VENT_PRESS_O2_INSP_INOP |
|
urn:iso:std:iso:11073:10101 |
197156 ![]() |
MDC_EVT_VENT_GAS_LINE_PROB |
|
urn:iso:std:iso:11073:10101 |
197158 ![]() |
MDC_EVT_VENT_GAS_MIXER_INOP | Gas mixer is inoperable. |
urn:iso:std:iso:11073:10101 |
197160 ![]() |
MDC_EVT_VENT_BREATHING_SYS_LEAK |
|
urn:iso:std:iso:11073:10101 |
197162 ![]() |
MDC_EVT_LIMIT_AL_LO | A metric falls short of a given threshold. |
urn:iso:std:iso:11073:10101 |
197166 ![]() |
MDC_EVT_PRESS_FLUID_LINE_EXCESS |
|
urn:iso:std:iso:11073:10101 |
197168 ![]() |
MDC_EVT_POWER_PROB | Problem in power supply |
urn:iso:std:iso:11073:10101 |
197170 ![]() |
MDC_EVT_ENVIRON |
|
urn:iso:std:iso:11073:10101 |
197172 ![]() |
MDC_EVT_VENT_DISCONN | Patient is disconnected from ventilator. |
urn:iso:std:iso:11073:10101 |
197174 ![]() |
MDC_EVT_SYRINGE_TIMEOUT_WARN |
|
urn:iso:std:iso:11073:10101 |
197176 ![]() |
MDC_EVT_USER_INPUT_DATA_VAL_ERR_HI | User keyboard input is higher than available with syringe type (pump). |
urn:iso:std:iso:11073:10101 |
197178 ![]() |
MDC_EVT_VENT_INOP |
|
urn:iso:std:iso:11073:10101 |
197180 ![]() |
MDC_EVT_VENT_STUCK |
|
urn:iso:std:iso:11073:10101 |
197182 ![]() |
MDC_EVT_PUMP_SYRINGE_DELIV_TIMEOUT | Configured time to deliver whole syringe/bottle is over. |
urn:iso:std:iso:11073:10101 |
197184 ![]() |
MDC_EVT_FLOW_OBSTRUC |
|
urn:iso:std:iso:11073:10101 |
197186 ![]() |
MDC_EVT_HUMID_HI_ERR |
|
urn:iso:std:iso:11073:10101 |
197188 ![]() |
MDC_EVT_FLUID_LINE_HI_GT_LIM_PRESSURE |
|
urn:iso:std:iso:11073:10101 |
197190 ![]() |
MDC_EVT_FLOW_FLUID_LINE_RES_WARN |
|
urn:iso:std:iso:11073:10101 |
197192 ![]() |
MDC_EVT_TIMEOUT | Timeout: device should be either operated or turned off. |
urn:iso:std:iso:11073:10101 |
197194 ![]() |
MDC_EVT_PUMP_VOL_TBI_COMP |
|
urn:iso:std:iso:11073:10101 |
197196 ![]() |
MDC_EVT_DISPOS_LO |
|
urn:iso:std:iso:11073:10101 |
197198 ![]() |
MDC_EVT_EQUIP |
|
urn:iso:std:iso:11073:10101 |
197200 ![]() |
MDC_EVT_FLUID_LINE_AIR | Air in fluid line. |
urn:iso:std:iso:11073:10101 |
197202 ![]() |
MDC_EVT_VENT_FLOW_O2_DELIV_LO |
|
urn:iso:std:iso:11073:10101 |
197204 ![]() |
MDC_EVT_VENT_CONC_O2_DELIV_LO |
|
urn:iso:std:iso:11073:10101 |
197206 ![]() |
MDC_EVT_PUMP_FLOW_FREE |
|
urn:iso:std:iso:11073:10101 |
197208 ![]() |
MDC_EVT_INCOMPAT |
|
urn:iso:std:iso:11073:10101 |
197210 ![]() |
MDC_EVT_MULT_REPLY_UNAVAIL | The multiple reply remote operation function is not available (see Clause 6 in ISO/IEEE 11073-20101:2004) |
urn:iso:std:iso:11073:10101 |
258047 ![]() |
MDC_EVT_NOS |
|
urn:iso:std:iso:11073:10101 |
199680 ![]() |
MDC_EVT_APNEA |
|
urn:iso:std:iso:11073:10101 |
199682 ![]() |
MDC_EVT_ECG_NOT_PACED |
|
urn:iso:std:iso:11073:10101 |
199684 ![]() |
MDC_EVT_ECG_ASYSTOLE | No QRS-complex found in predefined time period |
urn:iso:std:iso:11073:10101 |
199686 ![]() |
MDC_EVT_ECG_BEAT_MISSED | Missed beat within some regular ECG rhythm |
urn:iso:std:iso:11073:10101 |
199688 ![]() |
MDC_EVT_ECG_BEAT_UNUSUAL |
|
urn:iso:std:iso:11073:10101 |
199690 ![]() |
MDC_EVT_ECG_BIGEM |
|
urn:iso:std:iso:11073:10101 |
199692 ![]() |
MDC_EVT_ECG_SINUS_BRADY |
|
urn:iso:std:iso:11073:10101 |
199694 ![]() |
MDC_EVT_ECG_BRADY_EXTREME | Limit Event: Extreme Bradycardia (escalated low HR limit, not a brady rhythm) |
urn:iso:std:iso:11073:10101 |
199696 ![]() |
MDC_EVT_ECG_BRADY_SUST |
|
urn:iso:std:iso:11073:10101 |
199700 ![]() |
MDC_EVT_ECG_FIB |
|
urn:iso:std:iso:11073:10101 |
199702 ![]() |
MDC_EVT_ECG_NO_ECT_BEAT |
|
urn:iso:std:iso:11073:10101 |
199704 ![]() |
MDC_EVT_ECG_PACED_BEAT | Pacer pulse sensed by heart |
urn:iso:std:iso:11073:10101 |
199706 ![]() |
MDC_EVT_STAT_ECG_PACING | Pacer operational and controlling heart rhythm |
urn:iso:std:iso:11073:10101 |
199708 ![]() |
MDC_EVT_ECG_PACING_CAPT |
|
urn:iso:std:iso:11073:10101 |
199710 ![]() |
MDC_EVT_ECG_PACING_NON_CAPT |
|
urn:iso:std:iso:11073:10101 |
199712 ![]() |
MDC_EVT_ECG_PACING_RUN |
|
urn:iso:std:iso:11073:10101 |
199714 ![]() |
MDC_EVT_ECG_PATT | Unspecified ECG (arrhythmia) event |
urn:iso:std:iso:11073:10101 |
199716 ![]() |
MDC_EVT_ECG_PAUSE |
|
urn:iso:std:iso:11073:10101 |
199718 ![]() |
MDC_EVT_ECG_QUADRIGEM | Quadrigeminy |
urn:iso:std:iso:11073:10101 |
199720 ![]() |
MDC_EVT_ECG_RHY | Rhythm |
urn:iso:std:iso:11073:10101 |
199722 ![]() |
MDC_EVT_ECG_RHY_ABSENT | No [cardiac] rhythm |
urn:iso:std:iso:11073:10101 |
199724 ![]() |
MDC_EVT_ECG_RHY_ECT | Ectopic rhythm |
urn:iso:std:iso:11073:10101 |
199726 ![]() |
MDC_EVT_ECG_RR_IRREG | Irregular rhythm |
urn:iso:std:iso:11073:10101 |
199728 ![]() |
MDC_EVT_ECG_TACHY | Tachycardia |
urn:iso:std:iso:11073:10101 |
199730 ![]() |
MDC_EVT_ECG_TACHY_EXTREME | Limit Event: Extreme Tachycardia (escalated high HR limit, not a tachy rhythm) |
urn:iso:std:iso:11073:10101 |
199732 ![]() |
MDC_EVT_ECG_TACHY_UNSPEC |
|
urn:iso:std:iso:11073:10101 |
199734 ![]() |
MDC_EVT_ECG_TRIGEM |
|
urn:iso:std:iso:11073:10101 |
199736 ![]() |
MDC_EVT_ECG_ATR_FIB | Atrial fibrillation |
urn:iso:std:iso:11073:10101 |
199738 ![]() |
MDC_EVT_ECG_ATR_P_C | Premature atrial contraction |
urn:iso:std:iso:11073:10101 |
199740 ![]() |
MDC_EVT_ECG_ATR_PACING |
|
urn:iso:std:iso:11073:10101 |
199742 ![]() |
MDC_EVT_ECG_ATR_STAND |
|
urn:iso:std:iso:11073:10101 |
199744 ![]() |
MDC_EVT_ECG_ATR_TACHY | Atrial tachycardia |
urn:iso:std:iso:11073:10101 |
199746 ![]() |
MDC_EVT_ECG_ATR_TACHY_MULTIFOCAL |
|
urn:iso:std:iso:11073:10101 |
199748 ![]() |
MDC_EVT_ECG_ATR_TACHY_PAROX |
|
urn:iso:std:iso:11073:10101 |
199750 ![]() |
MDC_EVT_ECG_AV_DISSOC |
|
urn:iso:std:iso:11073:10101 |
199752 ![]() |
MDC_EVT_ECG_AV_PACING_SEQ | AV Pacing Sequential |
urn:iso:std:iso:11073:10101 |
199754 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_1 |
|
urn:iso:std:iso:11073:10101 |
199756 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2 |
|
urn:iso:std:iso:11073:10101 |
199758 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_I |
|
urn:iso:std:iso:11073:10101 |
199760 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_II |
|
urn:iso:std:iso:11073:10101 |
199762 ![]() |
MDC_EVT_ECG_BB_BLK |
|
urn:iso:std:iso:11073:10101 |
199764 ![]() |
MDC_EVT_ECG_CARD_BEAT_RATE_HI |
|
urn:iso:std:iso:11073:10101 |
199766 ![]() |
MDC_EVT_ECG_CARD_BEAT_RATE_IRREG | Error Event: Irregular heart rate (which means the beat detector finds a highly variable heart rate and cannot derive a consistent/stable value) |
urn:iso:std:iso:11073:10101 |
199768 ![]() |
MDC_EVT_ECG_CARD_BEAT_RATE_LO |
|
urn:iso:std:iso:11073:10101 |
199770 ![]() |
MDC_EVT_ECG_CARD_BEAT |
|
urn:iso:std:iso:11073:10101 |
199772 ![]() |
MDC_EVT_ECG_HEART_DYING |
|
urn:iso:std:iso:11073:10101 |
199774 ![]() |
MDC_EVT_ECG_HEART_BLK |
|
urn:iso:std:iso:11073:10101 |
199776 ![]() |
MDC_EVT_ECG_HEART_BLK_COMP |
|
urn:iso:std:iso:11073:10101 |
199778 ![]() |
MDC_EVT_ECG_JUNC_P_C |
|
urn:iso:std:iso:11073:10101 |
199780 ![]() |
MDC_EVT_ECG_JUNC_TACHY | Junctional tachycardia |
urn:iso:std:iso:11073:10101 |
199782 ![]() |
MDC_EVT_ECG_JUNC_TACHY_PAROX |
|
urn:iso:std:iso:11073:10101 |
199784 ![]() |
MDC_EVT_ECG_LA_FASC_BLK |
|
urn:iso:std:iso:11073:10101 |
199786 ![]() |
MDC_EVT_ECG_LBB_BLK |
|
urn:iso:std:iso:11073:10101 |
199788 ![]() |
MDC_EVT_ECG_LP_FASC_BLK |
|
urn:iso:std:iso:11073:10101 |
199790 ![]() |
MDC_EVT_ECG_PACER_NOT_PACING | Pacer (device) not sensing |
urn:iso:std:iso:11073:10101 |
199792 ![]() |
MDC_EVT_ECG_PT_NOT_PACED |
|
urn:iso:std:iso:11073:10101 |
199794 ![]() |
MDC_EVT_ECG_RBB_BLK |
|
urn:iso:std:iso:11073:10101 |
199796 ![]() |
MDC_EVT_ECG_SV_BEAT |
|
urn:iso:std:iso:11073:10101 |
199798 ![]() |
MDC_EVT_ECG_SV_P_C | Supraventricular extrasystole |
urn:iso:std:iso:11073:10101 |
199800 ![]() |
MDC_EVT_ECG_SV_TACHY | Supraventricular tachycardia |
urn:iso:std:iso:11073:10101 |
199802 ![]() |
MDC_EVT_ECG_V_PARASYS | Ventricular parasystole |
urn:iso:std:iso:11073:10101 |
199804 ![]() |
MDC_EVT_ECG_V_BIGEM |
|
urn:iso:std:iso:11073:10101 |
199806 ![]() |
MDC_EVT_ECG_V_FIB | Ventricular fibrillation |
urn:iso:std:iso:11073:10101 |
199810 ![]() |
MDC_EVT_ECG_V_FLUT | Ventricular flutter |
urn:iso:std:iso:11073:10101 |
199812 ![]() |
MDC_EVT_ECG_V_P_C | Premature ventricular contraction |
urn:iso:std:iso:11073:10101 |
199814 ![]() |
MDC_EVT_ECG_V_P_C_RonT | Premature ventricular contraction, R-on-T |
urn:iso:std:iso:11073:10101 |
199816 ![]() |
MDC_EVT_ECG_V_P_C_MULTIFORM | Multiformed premature ventricular contractions |
urn:iso:std:iso:11073:10101 |
199818 ![]() |
MDC_EVT_ECG_V_P_C_PAIR | Pair of premature ventricular contractions |
urn:iso:std:iso:11073:10101 |
199820 ![]() |
MDC_EVT_ECG_V_P_C_RUN | Several consecutive ventricular extrasystoles |
urn:iso:std:iso:11073:10101 |
199822 ![]() |
MDC_EVT_ECG_V_P_C_TRIP | VPC Triplet |
urn:iso:std:iso:11073:10101 |
199824 ![]() |
MDC_EVT_ECG_V_PACING |
|
urn:iso:std:iso:11073:10101 |
199826 ![]() |
MDC_EVT_ECG_V_QUADRIGEM |
|
urn:iso:std:iso:11073:10101 |
199828 ![]() |
MDC_EVT_ECG_V_RHY | Ventricular rhythm: escalation of Run of PVC, not yet flutter |
urn:iso:std:iso:11073:10101 |
199830 ![]() |
MDC_EVT_ECG_V_STAND |
|
urn:iso:std:iso:11073:10101 |
199832 ![]() |
MDC_EVT_ECG_V_TACHY | Ventricular tachycardia |
urn:iso:std:iso:11073:10101 |
199834 ![]() |
MDC_EVT_ECG_V_TACHY_NON_SUST |
|
urn:iso:std:iso:11073:10101 |
199836 ![]() |
MDC_EVT_ECG_V_TACHY_SUST |
|
urn:iso:std:iso:11073:10101 |
199838 ![]() |
MDC_EVT_ECG_V_TACHY_TORSADE |
|
urn:iso:std:iso:11073:10101 |
199840 ![]() |
MDC_EVT_ECG_V_TACHY_RHY |
|
urn:iso:std:iso:11073:10101 |
199842 ![]() |
MDC_EVT_ECG_V_TACHY_RHY_SUST |
|
urn:iso:std:iso:11073:10101 |
199844 ![]() |
MDC_EVT_ECG_V_TRIGEM |
|
urn:iso:std:iso:11073:10101 |
199846 ![]() |
MDC_EVT_ECG_V_TRIGEM_RHY |
|
urn:iso:std:iso:11073:10101 |
199848 ![]() |
MDC_EVT_ECG_STAT_ECT |
|
urn:iso:std:iso:11073:10101 |
199850 ![]() |
MDC_EVT_ECG_STAT_RHY |
|
urn:iso:std:iso:11073:10101 |
199852 ![]() |
MDC_EVT_UNEQU_HR_AND_PR | Cardiac and Pulse Rates are unequal |
urn:iso:std:iso:11073:10101 |
199854 ![]() |
MDC_EVT_DESAT |
|
urn:iso:std:iso:11073:10101 |
199856 ![]() |
MDC_EVT_ECG_SV_P_C_RUN | Several consecutive supraventricular extrasystoles |
urn:iso:std:iso:11073:10101 |
199860 ![]() |
MDC_EVT_ECG_V_P_C_RATE | A specific limit alert on the PVC rate |
urn:iso:std:iso:11073:10101 |
199862 ![]() |
MDC_EVT_EEG_SPK_AND_WV | Spikes and waves in EEG |
urn:iso:std:iso:11073:10101 |
199864 ![]() |
MDC_EVT_RESP_VOL_BREATHING_IRREG | Breathing volume not constant |
urn:iso:std:iso:11073:10101 |
199866 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_3 |
|
urn:iso:std:iso:11073:10101 |
199868 ![]() |
MDC_EVT_ECG_JUNC_RHY | Junctional rhythm |
urn:iso:std:iso:11073:10101 |
199870 ![]() |
MDC_EVT_ECG_SINUS_TACHY | Sinus tachycardia |
urn:iso:std:iso:11073:10101 |
199872 ![]() |
MDC_EVT_EEG_DISCHG_SEIZ_CLIN | Clinical seizure discharge in EEG |
urn:iso:std:iso:11073:10101 |
199874 ![]() |
MDC_EVT_ECG_ARRHY | Unspecified ECG (arrhythmia) event |
urn:iso:std:iso:11073:10101 |
199876 ![]() |
MDC_EVT_EEG_DISCHG_EPILEPTIFORM | Epileptiform discharges in EEG |
urn:iso:std:iso:11073:10101 |
199878 ![]() |
MDC_EVT_EEG_SPK_SHARP | Sharp spikes in EEG |
urn:iso:std:iso:11073:10101 |
199880 ![]() |
MDC_EVT_ECG_RHY_CPLT | Couplet |
urn:iso:std:iso:11073:10101 |
199882 ![]() |
MDC_EVT_ECG_V_P_C_FREQ | Frequent premature ventricular contractions |
urn:iso:std:iso:11073:10101 |
199884 ![]() |
MDC_EVT_ECG_ATR_FLUT | Atrial flutter |
urn:iso:std:iso:11073:10101 |
199886 ![]() |
MDC_EVT_RESP_BREATHING_SPONT_ASSIST_PSW |
|
urn:iso:std:iso:11073:10101 |
199888 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2_1 | 2:1 AV block |
urn:iso:std:iso:11073:10101 |
199890 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_3_1 | 3:1 AV block |
urn:iso:std:iso:11073:10101 |
199892 ![]() |
MDC_EVT_VENT_RESP_APNEA_15_SEC | Apnea - pressure absent for 15 seconds |
urn:iso:std:iso:11073:10101 |
199894 ![]() |
MDC_EVT_ECG_PACER_ABSENT | No pacer detected |
urn:iso:std:iso:11073:10101 |
199896 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_4_1 | 4:1 AV block |
urn:iso:std:iso:11073:10101 |
199898 ![]() |
MDC_EVT_ECG_SV_P_C_FREQ | Frequent supraventricular extrasystoles |
urn:iso:std:iso:11073:10101 |
199900 ![]() |
MDC_EVT_VENT_RESP_APNEA_30_SEC | Apnea - no volume exhale for 30 seconds |
urn:iso:std:iso:11073:10101 |
199902 ![]() |
MDC_EVT_ECG_PACER_ARTIF_RECOG | Pacer artifact recognized |
urn:iso:std:iso:11073:10101 |
199904 ![]() |
MDC_EVT_ERR_EQU_HR_AND_RR |
|
urn:iso:std:iso:11073:10101 |
199906 ![]() |
MDC_EVT_ECG_JUNC_ESC_BEATS |
|
urn:iso:std:iso:11073:10101 |
199908 ![]() |
MDC_EVT_ECG_JUNC_TACHY_RUN | Run of junctional tachycardia |
urn:iso:std:iso:11073:10101 |
199910 ![]() |
MDC_EVT_EQU_HR_AND_PR | Cardiac and Pulse Rates are equal |
urn:iso:std:iso:11073:10101 |
199912 ![]() |
MDC_EVT_EEG_BACK_ACTIV_ABSENT | Back Activity Absent |
urn:iso:std:iso:11073:10101 |
199914 ![]() |
MDC_EVT_BACK_ACTIV_ASYM | Back Activity Asymmetric |
urn:iso:std:iso:11073:10101 |
199916 ![]() |
MDC_EVT_PULS_NON_PULSATILE |
|
urn:iso:std:iso:11073:10101 |
202752 ![]() |
MDC_EVT_STAT_AL_OFF |
|
urn:iso:std:iso:11073:10101 |
202754 ![]() |
MDC_EVT_STAT_AL_ON |
|
urn:iso:std:iso:11073:10101 |
202756 ![]() |
MDC_EVT_STAT_BACKUP_MODE |
|
urn:iso:std:iso:11073:10101 |
202758 ![]() |
MDC_EVT_STAT_BATT_CHARGING | Battery is now being recharged. |
urn:iso:std:iso:11073:10101 |
202760 ![]() |
MDC_EVT_STAT_CALIB_MODE |
|
urn:iso:std:iso:11073:10101 |
202762 ![]() |
MDC_EVT_STAT_CALIB_RUNNING |
|
urn:iso:std:iso:11073:10101 |
202764 ![]() |
MDC_EVT_STAT_CALIB_INVIVO_RUNNING |
|
urn:iso:std:iso:11073:10101 |
202766 ![]() |
MDC_EVT_STAT_CALIB_LIGHT_RUNNING |
|
urn:iso:std:iso:11073:10101 |
202768 ![]() |
MDC_EVT_STAT_CALIB_PREINS_RUNNING |
|
urn:iso:std:iso:11073:10101 |
202770 ![]() |
MDC_EVT_STAT_CONFIG |
|
urn:iso:std:iso:11073:10101 |
202772 ![]() |
MDC_EVT_STAT_SELFTEST_RUNNING |
|
urn:iso:std:iso:11073:10101 |
202774 ![]() |
MDC_EVT_STAT_STANDBY_MODE |
|
urn:iso:std:iso:11073:10101 |
202776 ![]() |
MDC_EVT_STAT_TEST_RUNNING | Indication: Diagnostic test in Progress, No Measurement Possible |
urn:iso:std:iso:11073:10101 |
202778 ![]() |
MDC_EVT_STAT_ZERO_RUNNING |
|
urn:iso:std:iso:11073:10101 |
202780 ![]() |
MDC_EVT_STAT_OPT_MOD_SENSOR_CONN |
|
urn:iso:std:iso:11073:10101 |
202782 ![]() |
MDC_EVT_STAT_OPT_MOD_SENSOR_WARMING |
|
urn:iso:std:iso:11073:10101 |
202784 ![]() |
MDC_EVT_STAT_SENSOR_WARMING |
|
urn:iso:std:iso:11073:10101 |
202786 ![]() |
MDC_EVT_STAT_WARMING |
|
urn:iso:std:iso:11073:10101 |
202788 ![]() |
MDC_EVT_STAT_PRESS_SUST |
|
urn:iso:std:iso:11073:10101 |
202790 ![]() |
MDC_EVT_STAT_ECG_AL_ALL_OFF | Status: All ECG alarms are off (still need these in France to meet French homologation, despite MDD). |
urn:iso:std:iso:11073:10101 |
202792 ![]() |
MDC_EVT_STAT_ECG_AL_SOME_OFF | Status: Some ECG alarms are off (still need these in France to meet French homologation, despite MDD). |
urn:iso:std:iso:11073:10101 |
202796 ![]() |
MDC_EVT_STAT_MODE_SIGH_ACTIVE | Sigh mode is active. |
urn:iso:std:iso:11073:10101 |
202798 ![]() |
MDC_EVT_STAT_UNCALIB | VMD is not calibrated. |
urn:iso:std:iso:11073:10101 |
202804 ![]() |
MDC_EVT_STAT_VENT_GAS_MIXER_FUNC_DISABL | The function of gaseous agent mixing iris in a ventilator (anesthesia machine) is disabled. |
urn:iso:std:iso:11073:10101 |
202806 ![]() |
MDC_EVT_STAT_ACTIVE |
|
urn:iso:std:iso:11073:10101 |
202810 ![]() |
MDC_EVT_STAT_VENT_TIME_RESP_VOL_LIMITED |
|
urn:iso:std:iso:11073:10101 |
202814 ![]() |
MDC_EVT_STAT_VENT_PRESS_RESP_VOL_LIMITED |
|
urn:iso:std:iso:11073:10101 |
202818 ![]() |
MDC_EVT_STAT_VENT_AL_TACHAPNEA_DISABL |
|
urn:iso:std:iso:11073:10101 |
202820 ![]() |
MDC_EVT_STAT_CHARGING |
|
urn:iso:std:iso:11073:10101 |
202822 ![]() |
MDC_EVT_STAT_AL_SILENCE |
|
urn:iso:std:iso:11073:10101 |
202824 ![]() |
MDC_EVT_STAT_AL |
|
urn:iso:std:iso:11073:10101 |
202828 ![]() |
MDC_EVT_STAT_DOOR_OPEN |
|
urn:iso:std:iso:11073:10101 |
202830 ![]() |
MDC_EVT_STAT_NBP_INFL_TO_MAX_CUFF_PRESS |
|
urn:iso:std:iso:11073:10101 |
202832 ![]() |
MDC_EVT_STAT_LEARN |
|
urn:iso:std:iso:11073:10101 |
202834 ![]() |
MDC_EVT_STAT_OFF |
|
urn:iso:std:iso:11073:10101 |
202836 ![]() |
MDC_EVT_STAT_STANDBY |
|
urn:iso:std:iso:11073:10101 |
202838 ![]() |
MDC_EVT_STAT_AL_TACHAPNEA_DISABL |
|
urn:iso:std:iso:11073:10101 |
202840 ![]() |
MDC_EVT_STAT_MODE_TEST | Device or VMD is in test mode. |
urn:iso:std:iso:11073:10101 |
202842 ![]() |
MDC_EVT_STAT_WAVE_LEARN |
|
urn:iso:std:iso:11073:10101 |
202852 ![]() |
MDC_EVT_STAT_DOOR_CLOS |
|
urn:iso:std:iso:11073:10101 |
202856 ![]() |
MDC_EVT_STAT_DEPLET | A sensor, absorber, etc., is depleted. |
urn:iso:std:iso:11073:10101 |
202858 ![]() |
MDC_EVT_STAT_NBP_DEFL_AND_MEAS_BP |
|
urn:iso:std:iso:11073:10101 |
202860 ![]() |
MDC_EVT_STAT_CONN |
|
urn:iso:std:iso:11073:10101 |
202864 ![]() |
MDC_EVT_STAT_DISCONN | Disconnection of a sensor, device, etc. |
urn:iso:std:iso:11073:10101 |
202866 ![]() |
MDC_EVT_STAT_SOUND_IN_ROOM_OFF |
|
urn:iso:std:iso:11073:10101 |
202868 ![]() |
MDC_EVT_STAT_LIGHTS_IN_ROOM_ON |
|
urn:iso:std:iso:11073:10101 |
202872 ![]() |
MDC_EVT_STAT_SOUND_IN_ROOM_ON |
|
urn:iso:std:iso:11073:10101 |
202874 ![]() |
MDC_EVT_STAT_ON |
|
urn:iso:std:iso:11073:10101 |
202876 ![]() |
MDC_EVT_STAT_CO2_WARMING |
|
urn:iso:std:iso:11073:10101 |
202878 ![]() |
MDC_EVT_STAT_CO2_AL_DISABL |
|
urn:iso:std:iso:11073:10101 |
202880 ![]() |
MDC_EVT_STAT_QRS_BEEP_OFF |
|
urn:iso:std:iso:11073:10101 |
202882 ![]() |
MDC_EVT_STAT_APNEA_AL_DISABL |
|
urn:iso:std:iso:11073:10101 |
202884 ![]() |
MDC_EVT_STAT_DEV_BATT_OPERATED | Device is battery operated. |
urn:iso:std:iso:11073:10101 |
202886 ![]() |
MDC_EVT_STAT_DEV |
|
urn:iso:std:iso:11073:10101 |
202888 ![]() |
MDC_EVT_STAT_DEV_MODE_PEDIATRIC | Device is in pediatric mode. |
urn:iso:std:iso:11073:10101 |
202890 ![]() |
MDC_EVT_STAT_DEV_MODE_ADULT | Device is in adult mode. |
urn:iso:std:iso:11073:10101 |
202892 ![]() |
MDC_EVT_STAT_DEV_MAINS_OPERATED | Device is mains-operated. |
urn:iso:std:iso:11073:10101 |
202894 ![]() |
MDC_EVT_STAT_DEV_MODE_COMPUT_CNTRLD | Device, e.g., pump, is in computer-controlled mode. |
urn:iso:std:iso:11073:10101 |
202896 ![]() |
MDC_EVT_STAT_POWER_SET_LINE |
|
urn:iso:std:iso:11073:10101 |
202898 ![]() |
MDC_EVT_STAT_POWER_SET_BATT |
|
urn:iso:std:iso:11073:10101 |
202900 ![]() |
MDC_EVT_STAT_CO2_UNCALIB |
|
urn:iso:std:iso:11073:10101 |
202902 ![]() |
MDC_EVT_STAT_RUNNING |
|
urn:iso:std:iso:11073:10101 |
217184 ![]() |
MDC_EVT_STAT_VENT_BREATH_SPONT |
|
urn:iso:std:iso:11073:10101 |
217188 ![]() |
MDC_EVT_STAT_VENT_BREATH_MAND |
|
urn:iso:std:iso:11073:10101 |
203266 ![]() |
MDC_EVT_ADVIS_CHK |
|
urn:iso:std:iso:11073:10101 |
203268 ![]() |
MDC_EVT_ADVIS_CALIB_CHK | Advisory: Check Calibration |
urn:iso:std:iso:11073:10101 |
203270 ![]() |
MDC_EVT_ADVIS_CALIB_REQD |
|
urn:iso:std:iso:11073:10101 |
203272 ![]() |
MDC_EVT_ADVIS_CALIB_AND_ZERO_CHK |
|
urn:iso:std:iso:11073:10101 |
203274 ![]() |
MDC_EVT_ADVIS_CONFIG_CHK |
|
urn:iso:std:iso:11073:10101 |
203276 ![]() |
MDC_EVT_ADVIS_SETTINGS_CHK |
|
urn:iso:std:iso:11073:10101 |
203278 ![]() |
MDC_EVT_ADVIS_SETUP_CHK |
|
urn:iso:std:iso:11073:10101 |
203280 ![]() |
MDC_EVT_ADVIS_SRC_CHK |
|
urn:iso:std:iso:11073:10101 |
203282 ![]() |
MDC_EVT_ADVIS_ZERO_CHK |
|
urn:iso:std:iso:11073:10101 |
203284 ![]() |
MDC_EVT_ADVIS_BATT_COND |
|
urn:iso:std:iso:11073:10101 |
203286 ![]() |
MDC_EVT_ADVIS_BATT_REPLACE |
|
urn:iso:std:iso:11073:10101 |
203288 ![]() |
MDC_EVT_ADVIS_CABLE_CHK |
|
urn:iso:std:iso:11073:10101 |
203290 ![]() |
MDC_EVT_ADVIS_CO2_SENSOR_CHK |
|
urn:iso:std:iso:11073:10101 |
203292 ![]() |
MDC_EVT_ADVIS_COMM_CABLE_CHK |
|
urn:iso:std:iso:11073:10101 |
203294 ![]() |
MDC_EVT_ADVIS_DISPOS_REPLACE |
|
urn:iso:std:iso:11073:10101 |
203296 ![]() |
MDC_EVT_ADVIS_GAS_AGENT_CHK |
|
urn:iso:std:iso:11073:10101 |
203298 ![]() |
MDC_EVT_ADVIS_LEAD_CHK |
|
urn:iso:std:iso:11073:10101 |
203300 ![]() |
MDC_EVT_ADVIS_O2_SENSOR_CHK |
|
urn:iso:std:iso:11073:10101 |
203302 ![]() |
MDC_EVT_ADVIS_REC_PAPER_REPLACE |
|
urn:iso:std:iso:11073:10101 |
203304 ![]() |
MDC_EVT_ADVIS_SENSOR_CHK |
|
urn:iso:std:iso:11073:10101 |
203306 ![]() |
MDC_EVT_ADVIS_STATUS_LOG_CHK |
|
urn:iso:std:iso:11073:10101 |
203310 ![]() |
MDC_EVT_ADVIS_VOL_SENSOR_CHK |
|
urn:iso:std:iso:11073:10101 |
203312 ![]() |
MDC_EVT_ADVIS_GAIN_DECR |
|
urn:iso:std:iso:11073:10101 |
203314 ![]() |
MDC_EVT_ADVIS_GAIN_INCR |
|
urn:iso:std:iso:11073:10101 |
203316 ![]() |
MDC_EVT_ADVIS_TIME_CHK |
|
urn:iso:std:iso:11073:10101 |
203318 ![]() |
MDC_EVT_ADVIS_UNIT_CHK |
|
urn:iso:std:iso:11073:10101 |
203320 ![]() |
MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_WARN |
|
urn:iso:std:iso:11073:10101 |
203322 ![]() |
MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_IMMED | Syringe needs to be replaced immediately. |
urn:iso:std:iso:11073:10101 |
203324 ![]() |
MDC_EVT_ADVIS_VENT_WATER_TRAP_CHK |
|
urn:iso:std:iso:11073:10101 |
203326 ![]() |
MDC_EVT_ADVIS_VAPORISER_CHK_DISCONN | Advisory: Vaporizer is not connected, not known or not allowed. |
urn:iso:std:iso:11073:10101 |
203328 ![]() |
MDC_EVT_ADVIS_VENT_PRESS_AWAY_CHK |
|
urn:iso:std:iso:11073:10101 |
203330 ![]() |
MDC_EVT_ADVIS_VENT_FLOW_SENSOR_CHK |
|
urn:iso:std:iso:11073:10101 |
203332 ![]() |
MDC_EVT_ADVIS_VENT_FLOW_CALIB | Flow calibration of ventilator is necessary. |
urn:iso:std:iso:11073:10101 |
203334 ![]() |
MDC_EVT_ADVIS_VENT_MIX_IRIS_CALIB |
|
urn:iso:std:iso:11073:10101 |
203336 ![]() |
MDC_EVT_ADVIS_VENT_AIR_SUPP_CHK | Checking of ventilator air supply is necessary. |
urn:iso:std:iso:11073:10101 |
203338 ![]() |
MDC_EVT_ADVIS_VENT_EXP_VALVE_CHK |
|
urn:iso:std:iso:11073:10101 |
258048 ![]() |
MDC_EVT_STANDBY_WARN | Warning that device will go to standy |
urn:iso:std:iso:11073:10101 |
203341 ![]() |
MDC_EVT_ADVIS_MAINT_NEEDED |
|
urn:iso:std:iso:11073:10101 |
197212 ![]() |
MDC_EVT_SYRINGE_PATIENT_PRESSURE_HI | IV Fluid pressure is too high on the downstream patient side. |
urn:iso:std:iso:11073:10101 |
197214 ![]() |
MDC_EVT_SYRINGE_PLUNGER_POSITION | Plunger out of position |
urn:iso:std:iso:11073:10101 |
197216 ![]() |
MDC_EVT_SYRINGE_FLANGE_POSITION | Flange out of position |
urn:iso:std:iso:11073:10101 |
197218 ![]() |
MDC_EVT_SYRINGE_BARREL_CAPTURE_FAULT | Syringe barrel capture fault. |
urn:iso:std:iso:11073:10101 |
197220 ![]() |
MDC_EVT_SYRINGE_PRESSURE_DISC_POSITION | Pressure disc out of position |
urn:iso:std:iso:11073:10101 |
197222 ![]() |
MDC_EVT_SYRINGE_NUT_ENGAGED | |
urn:iso:std:iso:11073:10101 |
197224 ![]() |
MDC_EVT_SYRINGE_END_OF_TRAVEL | End of plunger travel |
urn:iso:std:iso:11073:10101 |
197226 ![]() |
MDC_EVT_SYRINGE_EMPTY | Syringe is empty |
urn:iso:std:iso:11073:10101 |
197228 ![]() |
MDC_EVT_SYRINGE_PATIENT_PRESSURE_ALARM | |
urn:iso:std:iso:11073:10101 |
197230 ![]() |
MDC_EVT_SYRINGE_PLUNGER | |
urn:iso:std:iso:11073:10101 |
197232 ![]() |
MDC_EVT_SYRINGE_FLANGE | |
urn:iso:std:iso:11073:10101 |
197234 ![]() |
MDC_EVT_SYRINGE_LEVER | |
urn:iso:std:iso:11073:10101 |
197236 ![]() |
MDC_EVT_SYRINGE_PRESSURE_DISC | |
urn:iso:std:iso:11073:10101 |
197258 ![]() |
MDC_EVT_PCA_DOOR_UNLOCKED |
|
urn:iso:std:iso:11073:10101 |
197260 ![]() |
MDC_EVT_PCA_HANDSET_DETACHED |
|
urn:iso:std:iso:11073:10101 |
197262 ![]() |
MDC_EVT_PCA_MAX_LIMIT |
|
urn:iso:std:iso:11073:10101 |
197264 ![]() |
MDC_EVT_PCA_PAUSED |
|
urn:iso:std:iso:11073:10101 |
197288 ![]() |
MDC_EVT_PUMP_DELIV_START | Delivery Start |
urn:iso:std:iso:11073:10101 |
197290 ![]() |
MDC_EVT_PUMP_DELIV_STOP | Delivery Stop (or Paused) |
urn:iso:std:iso:11073:10101 |
197292 ![]() |
MDC_EVT_PUMP_DELIV_COMP | Delivery Complete |
urn:iso:std:iso:11073:10101 |
197294 ![]() |
MDC_EVT_COMM_STATUS_CHANGE |
|
urn:iso:std:iso:11073:10101 |
197296 ![]() |
MDC_EVT_PUMP_PROG_CLEARED | Program Cleared |
urn:iso:std:iso:11073:10101 |
197298 ![]() |
MDC_EVT_PUMP_AUTO_PROG_CLEARED | Auto-Program Cleared |
urn:iso:std:iso:11073:10101 |
197300 ![]() |
MDC_EVT_PATIENT_CHANGE |
|
urn:iso:std:iso:11073:10101 |
197302 ![]() |
MDC_EVT_PATIENT_ID_CHANGE |
|
urn:iso:std:iso:11073:10101 |
197304 ![]() |
MDC_EVT_PATIENT_WEIGHT_CHANGE |
|
urn:iso:std:iso:11073:10101 |
197328 ![]() |
MDC_EVT_IDLE |
|
urn:iso:std:iso:11073:10101 |
197330 ![]() |
MDC_EVT_CALLBACK |
|
urn:iso:std:iso:11073:10101 |
197332 ![]() |
MDC_EVT_VOL_INFUS_COMP |
|
urn:iso:std:iso:11073:10101 |
197334 ![]() |
MDC_EVT_VOL_INFUS_NEAR_COMP |
|
urn:iso:std:iso:11073:10101 |
197336 ![]() |
MDC_EVT_BATT_DEPL |
|
urn:iso:std:iso:11073:10101 |
197338 ![]() |
MDC_EVT_BATT_SERV |
|
urn:iso:std:iso:11073:10101 |
197340 ![]() |
MDC_EVT_EMER_STOP | Emergency Stop |
urn:iso:std:iso:11073:10101 |
197342 ![]() |
MDC_EVT_PWR_LOSS |
|
urn:iso:std:iso:11073:10101 |
197344 ![]() |
MDC_EVT_FLOW_STOP_OPEN | Flow stop valve is open |
urn:iso:std:iso:11073:10101 |
197346 ![]() |
MDC_EVT_CHECK_IV_SET |
|
urn:iso:std:iso:11073:10101 |
197348 ![]() |
MDC_EVT_UNKNOWN | An unknown event has occurred. |
urn:iso:std:iso:11073:10101 |
197350 ![]() |
MDC_EVT_DELAY_IMPOSSIBLE | Programmed start delay will not be reached |
urn:iso:std:iso:11073:10101 |
197352 ![]() |
MDC_EVT_PUMP_CHAMBER_BLOCKED | Pump chamber blocked. |
urn:iso:std:iso:11073:10101 |
197354 ![]() |
MDC_EVT_HANDSET_DETACHED |
|
urn:iso:std:iso:11073:10101 |
197306 ![]() |
MDC_EVT_PUMP_VOL_COUNTERS_CLEARED | Pump volume counters cleared |
urn:iso:std:iso:11073:10101 |
197308 ![]() |
MDC_EVT_DEVICE_TIME_CHANGED | Device time, civil time zone offsett and/or cumulative leap second information has changed |
urn:iso:std:iso:11073:10101 |
197356 ![]() |
MDC_EVT_PATIENT_PARAMETER_CHANGE |
|
urn:iso:std:iso:11073:10101 |
197358 ![]() |
MDC_EVT_FLUID_LINE_OCCL_UPSTREAM |
|
urn:iso:std:iso:11073:10101 |
197360 ![]() |
MDC_EVT_FLUID_LINE_OCCL_DOWNSTREAM |
|
urn:iso:std:iso:11073:10101 |
197362 ![]() |
MDC_EVT_FLUID_LINE_AIR_UPSTREAM |
|
urn:iso:std:iso:11073:10101 |
197364 ![]() |
MDC_EVT_FLUID_LINE_AIR_DOWNSTREAM |
|
urn:iso:std:iso:11073:10101 |
197376 ![]() |
MDC_EVT_DATA_INVALID | Invalid data (for any reason, including missing data) |
urn:iso:std:iso:11073:10101 |
197378 ![]() |
MDC_EVT_DATA_MISSING | Missing data (e.g., telemetry data dropouts) |
urn:iso:std:iso:11073:10101 |
203776 ![]() |
MDC_EVT_LS_DEVICE |
|
urn:iso:std:iso:11073:10101 |
203778 ![]() |
MDC_EVT_LS_PERSON |
|
urn:iso:std:iso:11073:10101 |
203780 ![]() |
MDC_EVT_LS_MOVEMENT |
|
urn:iso:std:iso:11073:10101 |
203782 ![]() |
MDC_EVT_LS_BOUNDARY |
|
urn:iso:std:iso:11073:10101 |
203784 ![]() |
MDC_EVT_LS_COLOCATION |
|
urn:iso:std:iso:11073:10101 |
203786 ![]() |
MDC_EVT_LS_DWELL |
|
urn:iso:std:iso:11073:10101 |
203788 ![]() |
MDC_EVT_LS_ACCELEROMETER |
|
urn:iso:std:iso:11073:10101 |
203790 ![]() |
MDC_EVT_LS_TAMPER |
|
urn:iso:std:iso:11073:10101 |
203792 ![]() |
MDC_EVT_LS_INTERACTION |
|
urn:iso:std:iso:11073:10101 |
203794 ![]() |
MDC_EVT_LS_MISSING |
|
urn:iso:std:iso:11073:10101 |
203796 ![]() |
MDC_EVT_LS_ENVIRONMENT |
|
urn:iso:std:iso:11073:10101 |
203798 ![]() |
MDC_EVT_LS_BATTERY |
|
urn:iso:std:iso:11073:10101 |
196848 ![]() |
MDC_EVT_CUFF_LOOSE | Cuff loose |
urn:iso:std:iso:11073:10101 |
202826 ![]() |
MDC_EVT_STAT_AL_PAUSED |
|
urn:iso:std:iso:11073:10101 |
197440 ![]() |
MDC_EVT_SW_VER_REPORT | An event or report regarding software version and update status |
urn:iso:std:iso:11073:10101 |
197442 ![]() |
MDC_EVT_TLS_CERT_EXPIRY | An event or report regarding that the TLS (Transport Layer Security) certificate is about to expire or has expired |
urn:iso:std:iso:11073:10101 |
196609 ![]() |
MDC_EVT | Definition for base term 3::0 MDC_EVT is: 1. An event has occurred (NOS) 2. Event (NOS). |
urn:iso:std:iso:11073:10101 |
196611 ![]() |
MDC_EVT_ABNORM | Definition for base term 3::2 MDC_EVT_ABNORM is: 1. Abnormal condition detected (NOS) 2. Abnormal condition detected. |
urn:iso:std:iso:11073:10101 |
196613 ![]() |
MDC_EVT_ABSENT | Definition for base term 3::4 MDC_EVT_ABSENT is: 1. Absent 2. Absent. |
urn:iso:std:iso:11073:10101 |
196615 ![]() |
MDC_EVT_ACTIVE | Definition for base term 3::6 MDC_EVT_ACTIVE is: Active (NOS) |
urn:iso:std:iso:11073:10101 |
203285 ![]() |
MDC_EVT_ADVIS_BATT_COND | Definition for base term 3::6676 MDC_EVT_ADVIS_BATT_COND is: 1. Advisory: Condition Battery (battery needs a special ‘condition’ charge cycle for full capacity.) 2. Advisory: Condition Battery (battery needs a special 'condition' charge cycle for full capacity.). |
urn:iso:std:iso:11073:10101 |
203287 ![]() |
MDC_EVT_ADVIS_BATT_REPLACE | Definition for base term 3::6678 MDC_EVT_ADVIS_BATT_REPLACE is: 1. Advisory: Replace Battery (a full charge is now a too small fraction of the original capacity or this is not a rechargeable battery that is close to empty.) 2. Advisory: Replace Battery (a full charge is now a too small fraction of the original capacity, or this is not a rechargeable battery that is close to empty.). |
urn:iso:std:iso:11073:10101 |
203289 ![]() |
MDC_EVT_ADVIS_CABLE_CHK | Definition for base term 3::6680 MDC_EVT_ADVIS_CABLE_CHK is: 1. Advisory: Check cable 2. Advisory: Check cable. |
urn:iso:std:iso:11073:10101 |
203273 ![]() |
MDC_EVT_ADVIS_CALIB_AND_ZERO_CHK | Definition for base term 3::6664 MDC_EVT_ADVIS_CALIB_AND_ZERO_CHK is: 1. Advisory: Check Calibration/Zero (system is not sure if calibration data is still ok.) 2. Advisory: Check Calibration/Zero required 3. Advisory: Check {invasive blood pressure} calibration/zero (device or system is not sure if calibration data is still ok.). |
urn:iso:std:iso:11073:10101 |
203269 ![]() |
MDC_EVT_ADVIS_CALIB_CHK | Definition for base term 3::6660 MDC_EVT_ADVIS_CALIB_CHK is: Advisory: Check Calibration |
urn:iso:std:iso:11073:10101 |
203271 ![]() |
MDC_EVT_ADVIS_CALIB_REQD | Definition for base term 3::6662 MDC_EVT_ADVIS_CALIB_REQD is: 1. Advisory: Calibration required 2. Advisory: {NBP} calibration required. |
urn:iso:std:iso:11073:10101 |
203267 ![]() |
MDC_EVT_ADVIS_CHK | Definition for base term 3::6658 MDC_EVT_ADVIS_CHK is: 1. Advisory: Check device or system (NOS) 2. Check {fresh-gas setting} |
urn:iso:std:iso:11073:10101 |
203291 ![]() |
MDC_EVT_ADVIS_CO2_SENSOR_CHK | Definition for base term 3::6682 MDC_EVT_ADVIS_CO2_SENSOR_CHK is: 1. Advisory: Check CO sensor 2. Advisory: Check the airway CO2 sensor. |
urn:iso:std:iso:11073:10101 |
203293 ![]() |
MDC_EVT_ADVIS_COMM_CABLE_CHK | Definition for base term 3::6684 MDC_EVT_ADVIS_COMM_CABLE_CHK is: 1. Advisory: Check communication cable 2. Advisory: Check comm cable. |
urn:iso:std:iso:11073:10101 |
203275 ![]() |
MDC_EVT_ADVIS_CONFIG_CHK | Definition for base term 3::6666 MDC_EVT_ADVIS_CONFIG_CHK is: 1. Advisory: Check Configuration 2. Advisory: Check configuration. |
urn:iso:std:iso:11073:10101 |
203295 ![]() |
MDC_EVT_ADVIS_DISPOS_REPLACE | Definition for base term 3::6686 MDC_EVT_ADVIS_DISPOS_REPLACE is: 1. Advisory: Replace disposable 2. Advisory: Replace disposable. |
urn:iso:std:iso:11073:10101 |
203313 ![]() |
MDC_EVT_ADVIS_GAIN_DECR | Definition for base term 3::6704 MDC_EVT_ADVIS_GAIN_DECR is: 1. Advisory: Decrease Gain (system asks user to decrease the gain; this advisory is different from the overrange error, ErrorEvent, that already is in the nomenclature; it is an "advisory.") 2. Advisory: Signal voltage out of range; gain adjustment necessary 3. Advisory: Decrease Gain (system asks user to decrease the gain; this advisory is different from the overrange error, ErrorEvent, that already is in the nomenclature; it is an "advisory."). |
urn:iso:std:iso:11073:10101 |
203315 ![]() |
MDC_EVT_ADVIS_GAIN_INCR | Definition for base term 3::6706 MDC_EVT_ADVIS_GAIN_INCR is: 1. Advisory: Signal voltage out of range; gain adjustment necessary 2. Signal voltage out of range. |
urn:iso:std:iso:11073:10101 |
203297 ![]() |
MDC_EVT_ADVIS_GAS_AGENT_CHK | Definition for base term 3::6688 MDC_EVT_ADVIS_GAS_AGENT_CHK is: 1. Advisory: Check gas agent 2. Advisory: Check gas agent. |
urn:iso:std:iso:11073:10101 |
203299 ![]() |
MDC_EVT_ADVIS_LEAD_CHK | Definition for base term 3::6690 MDC_EVT_ADVIS_LEAD_CHK is: 1. Advisory: Check patient lead or connector 2. Advisory: Check patient {ECG} leads or connector. |
urn:iso:std:iso:11073:10101 |
203301 ![]() |
MDC_EVT_ADVIS_O2_SENSOR_CHK | Definition for base term 3::6692 MDC_EVT_ADVIS_O2_SENSOR_CHK is: 1. Advisory: Check O sensor 2. Advisory: Check O2 sensor. |
urn:iso:std:iso:11073:10101 |
203323 ![]() |
MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_IMMED | Definition for base term 3::6714 MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_IMMED is: Syringe needs to be replaced immediately. |
urn:iso:std:iso:11073:10101 |
203321 ![]() |
MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_WARN | Definition for base term 3::6712 MDC_EVT_ADVIS_PUMP_SYRINGE_REPLACE_WARN is: 1. Advisory: Syringe needs to be replaced soon. 2. Syringe needs to be replaced soon. |
urn:iso:std:iso:11073:10101 |
203303 ![]() |
MDC_EVT_ADVIS_REC_PAPER_REPLACE | Definition for base term 3::6694 MDC_EVT_ADVIS_REC_PAPER_REPLACE is: 1. Problem with recording paper subdevice 2. Problem with recording paper subdevice. |
urn:iso:std:iso:11073:10101 |
203305 ![]() |
MDC_EVT_ADVIS_SENSOR_CHK | Definition for base term 3::6696 MDC_EVT_ADVIS_SENSOR_CHK is: 1. The sensor must be checked. 2. Advisory: Check sensor. 3. {ecgResp} Check sensor 4. {sensor} Check sensor |
urn:iso:std:iso:11073:10101 |
203277 ![]() |
MDC_EVT_ADVIS_SETTINGS_CHK | Definition for base term 3::6668 MDC_EVT_ADVIS_SETTINGS_CHK is: 1. Advisory: Check Settings 2. Advisory: Check setting[s]. |
urn:iso:std:iso:11073:10101 |
203279 ![]() |
MDC_EVT_ADVIS_SETUP_CHK | Definition for base term 3::6670 MDC_EVT_ADVIS_SETUP_CHK is: 1. Advisory: Check Set up 2. Advisory: Check setup. |
urn:iso:std:iso:11073:10101 |
203281 ![]() |
MDC_EVT_ADVIS_SRC_CHK | Definition for base term 3::6672 MDC_EVT_ADVIS_SRC_CHK is: 1. Advisory: Check Source 2. Advisory: Check data source or module. |
urn:iso:std:iso:11073:10101 |
203307 ![]() |
MDC_EVT_ADVIS_STATUS_LOG_CHK | Definition for base term 3::6698 MDC_EVT_ADVIS_STATUS_LOG_CHK is: 1. Advisory: Check Log (a fatal system error was entered in a log object and should be read.) 2. Advisory: Check Log (a fatal system error was entered in a log object and should be read.). |
urn:iso:std:iso:11073:10101 |
203317 ![]() |
MDC_EVT_ADVIS_TIME_CHK | Definition for base term 3::6708 MDC_EVT_ADVIS_TIME_CHK is: 1. Advisory: Check time (system asks user to check the time) 2. Advisory: Check time. |
urn:iso:std:iso:11073:10101 |
203319 ![]() |
MDC_EVT_ADVIS_UNIT_CHK | Definition for base term 3::6710 MDC_EVT_ADVIS_UNIT_CHK is: 1. Advisory: Check unit (system asks user to check unit) 2. Advisory: Check units [of msmt]. |
urn:iso:std:iso:11073:10101 |
203327 ![]() |
MDC_EVT_ADVIS_VAPORISER_CHK_DISCONN | Definition for base term 3::6718 MDC_EVT_ADVIS_VAPORISER_CHK_DISCONN is: Advisory: Vaporizer is not connected, not known or not allowed. |
urn:iso:std:iso:11073:10101 |
203337 ![]() |
MDC_EVT_ADVIS_VENT_AIR_SUPP_CHK | Definition for base term 3::6728 MDC_EVT_ADVIS_VENT_AIR_SUPP_CHK is: Checking of ventilator air supply is necessary. |
urn:iso:std:iso:11073:10101 |
203339 ![]() |
MDC_EVT_ADVIS_VENT_EXP_VALVE_CHK | Definition for base term 3::6730 MDC_EVT_ADVIS_VENT_EXP_VALVE_CHK is: 1. Checking of expiration valve is necessary. 2. Check expiration valve. 3. Checking of expiratory valve is necessary. |
urn:iso:std:iso:11073:10101 |
203333 ![]() |
MDC_EVT_ADVIS_VENT_FLOW_CALIB | Definition for base term 3::6724 MDC_EVT_ADVIS_VENT_FLOW_CALIB is: Flow calibration of ventilator is necessary. |
urn:iso:std:iso:11073:10101 |
203331 ![]() |
MDC_EVT_ADVIS_VENT_FLOW_SENSOR_CHK | Definition for base term 3::6722 MDC_EVT_ADVIS_VENT_FLOW_SENSOR_CHK is: 1. Checking of flow sensor in a ventilator is necessary. 2. Check flow sensor in a ventilator. |
urn:iso:std:iso:11073:10101 |
203335 ![]() |
MDC_EVT_ADVIS_VENT_MIX_IRIS_CALIB | Definition for base term 3::6726 MDC_EVT_ADVIS_VENT_MIX_IRIS_CALIB is: 1. The mixing iris in agent vaporizer in a ventilator must be checked (anesthesia machine). 2. The mixing iris in agent vaporizer in an ventilator must be checked (anesthesia machine). |
urn:iso:std:iso:11073:10101 |
203329 ![]() |
MDC_EVT_ADVIS_VENT_PRESS_AWAY_CHK | Definition for base term 3::6720 MDC_EVT_ADVIS_VENT_PRESS_AWAY_CHK is: 1. Checking of airway pressure in a ventilator is necessary. 2. Advisory: Check airway pressure in ventilator. |
urn:iso:std:iso:11073:10101 |
203325 ![]() |
MDC_EVT_ADVIS_VENT_WATER_TRAP_CHK | Definition for base term 3::6716 MDC_EVT_ADVIS_VENT_WATER_TRAP_CHK is: 1. Checking of water trap in a ventilator is necessary. 2. Advisory: Check water trap in a ventilator. 3. Check ventilator water trap. |
urn:iso:std:iso:11073:10101 |
203311 ![]() |
MDC_EVT_ADVIS_VOL_SENSOR_CHK | Definition for base term 3::6702 MDC_EVT_ADVIS_VOL_SENSOR_CHK is: 1. Advisory: Check volume sensor 2. Advisory: Check volume sensor. |
urn:iso:std:iso:11073:10101 |
203283 ![]() |
MDC_EVT_ADVIS_ZERO_CHK | Definition for base term 3::6674 MDC_EVT_ADVIS_ZERO_CHK is: 1. Advisory: Check Zero 2. Advisory: Check zero, e.g. check {invasive blood pressure} zero. |
urn:iso:std:iso:11073:10101 |
197019 ![]() |
MDC_EVT_AL_LIMIT | Definition for base term 3::410 MDC_EVT_AL_LIMIT is: 1. Alarm limit exceeded 2. Alarm Limit. |
urn:iso:std:iso:11073:10101 |
196617 ![]() |
MDC_EVT_ALARM | Definition for base term 3::8 MDC_EVT_ALARM is: 1. Alarm (NOS) 2. Alarm (NOS). |
urn:iso:std:iso:11073:10101 |
199681 ![]() |
MDC_EVT_APNEA | Definition for base term 3::3072 MDC_EVT_APNEA is: 1. No breathing within a pre-configured time span 2. Apnea |
urn:iso:std:iso:11073:10101 |
199915 ![]() |
MDC_EVT_BACK_ACTIV_ASYM | Definition for base term 3::3306 MDC_EVT_BACK_ACTIV_ASYM is: Back Activity Asymmetric |
urn:iso:std:iso:11073:10101 |
197337 ![]() |
MDC_EVT_BATT_DEPL | Definition for base term 3::728 MDC_EVT_BATT_DEPL is: 1. Battery depleted 2. Depleted Battery |
urn:iso:std:iso:11073:10101 |
196801 ![]() |
MDC_EVT_BATT_FAIL | Definition for base term 3::192 MDC_EVT_BATT_FAIL is: 1. Battery failed or is defective 2. {*} Battery inoperable |
urn:iso:std:iso:11073:10101 |
196803 ![]() |
MDC_EVT_BATT_LO | Definition for base term 3::194 MDC_EVT_BATT_LO is: 1. Battery discharged or is defective. 2. {ecgResp} Battery low 3. {device or sensor} Battery low |
urn:iso:std:iso:11073:10101 |
196805 ![]() |
MDC_EVT_BATT_MALF | Definition for base term 3::196 MDC_EVT_BATT_MALF is: Battery malfunction |
urn:iso:std:iso:11073:10101 |
196807 ![]() |
MDC_EVT_BATT_PROB | Definition for base term 3::198 MDC_EVT_BATT_PROB is: Unspecified battery problem |
urn:iso:std:iso:11073:10101 |
197339 ![]() |
MDC_EVT_BATT_SERV | Definition for base term 3::730 MDC_EVT_BATT_SERV is: 1. Battery service required 2. Service Battery |
urn:iso:std:iso:11073:10101 |
196745 ![]() |
MDC_EVT_BREATH_ABSENT | Definition for base term 3::136 MDC_EVT_BREATH_ABSENT is: 1. Error Event: Breath Absent (this is not apnea, but a technical ventilator event.) 2. Error Event: breath absent (this is not apnea, but a technical ventilator event.). |
urn:iso:std:iso:11073:10101 |
197111 ![]() |
MDC_EVT_BUFF_OVERFLOW | Definition for base term 3::502 MDC_EVT_BUFF_OVERFLOW is: 1. Communication timing error: buffer overflow 2. Communication timing error: buffer overflow. |
urn:iso:std:iso:11073:10101 |
196949 ![]() |
MDC_EVT_BW_INCORRECT | Definition for base term 3::340 MDC_EVT_BW_INCORRECT is: 1. Bandwidth incorrect 2. Bandwidth incorrect. |
urn:iso:std:iso:11073:10101 |
196813 ![]() |
MDC_EVT_CABLE_SHORT | Definition for base term 3::204 MDC_EVT_CABLE_SHORT is: 1. Communication error: cable short 2. {SpO2} Cable failure |
urn:iso:std:iso:11073:10101 |
196747 ![]() |
MDC_EVT_CALIB_FAIL | Definition for base term 3::138 MDC_EVT_CALIB_FAIL is: 1. Calibration is not successful. 2. {SpO2} Only Mode (not fully calibrated) |
urn:iso:std:iso:11073:10101 |
197331 ![]() |
MDC_EVT_CALLBACK | Definition for base term 3::722 MDC_EVT_CALLBACK is: 1. Callback 2. Callback notififaction to the clinician, e.g. that the secondary infusion has been completed |
urn:iso:std:iso:11073:10101 |
196815 ![]() |
MDC_EVT_CATH_PULM_INFLAT_OVER | Definition for base term 3::206 MDC_EVT_CATH_PULM_INFLAT_OVER is: 1. Pulmonary Capillary Wedge Pressure: over inflation 2. {Pulmonary artery catheter} catheter cuff over-inflated. |
urn:iso:std:iso:11073:10101 |
197347 ![]() |
MDC_EVT_CHECK_IV_SET | Definition for base term 3::738 MDC_EVT_CHECK_IV_SET is: 1. Advisory: Check Intravenous Set 2. Check IV set. |
urn:iso:std:iso:11073:10101 |
196817 ![]() |
MDC_EVT_CKT_SHORT | Definition for base term 3::208 MDC_EVT_CKT_SHORT is: A short circuit was detected in a VMD. |
urn:iso:std:iso:11073:10101 |
196821 ![]() |
MDC_EVT_CO2_CAN_LEAK | Definition for base term 3::212 MDC_EVT_CO2_CAN_LEAK is: 1. CO2 Canister leak 2. CO2 canister leak. |
urn:iso:std:iso:11073:10101 |
197071 ![]() |
MDC_EVT_CO2_MSMT_FAIL | Definition for base term 3::462 MDC_EVT_CO2_MSMT_FAIL is: 1. Failure occurred in a CO2 measuring device. 2. A failure occurred in the airway CO2 measuring device. |
urn:iso:std:iso:11073:10101 |
196823 ![]() |
MDC_EVT_CO2_SAMPL_LINE_DEFECT | Definition for base term 3::214 MDC_EVT_CO2_SAMPL_LINE_DEFECT is: Defect occurred in a CO2 sample line |
urn:iso:std:iso:11073:10101 |
197073 ![]() |
MDC_EVT_CO2_SENSOR_FAIL | Definition for base term 3::464 MDC_EVT_CO2_SENSOR_FAIL is: 1. Fault occurred in carbon dioxide sensor disc. 2. A fault occurred in the airway CO2 sensor. |
urn:iso:std:iso:11073:10101 |
196825 ![]() |
MDC_EVT_CO2_WIND_OBSTRUC | Definition for base term 3::216 MDC_EVT_CO2_WIND_OBSTRUC is: 1. Carbon dioxide measurement window in a CO2 measuring device is occluded. 2. The airway CO2 sensor window is occluded. |
urn:iso:std:iso:11073:10101 |
197077 ![]() |
MDC_EVT_COMM | Definition for base term 3::468 MDC_EVT_COMM is: 1. Communication error: NOS 2. Unspecified communication event. |
urn:iso:std:iso:11073:10101 |
196827 ![]() |
MDC_EVT_COMM_LINK_NOISY | Definition for base term 3::218 MDC_EVT_COMM_LINK_NOISY is: 1. Error Event: Communication Link Noisy 2. Comm link noisy. |
urn:iso:std:iso:11073:10101 |
196749 ![]() |
MDC_EVT_COMM_LOST | Definition for base term 3::140 MDC_EVT_COMM_LOST is: 1. Error Event: Communication Lost 2. {Monitor} No communications |
urn:iso:std:iso:11073:10101 |
196829 ![]() |
MDC_EVT_COMM_MODULE_ERR | Definition for base term 3::220 MDC_EVT_COMM_MODULE_ERR is: 1. Error Event: Communication Module Error 2. Communication module error. |
urn:iso:std:iso:11073:10101 |
197295 ![]() |
MDC_EVT_COMM_STATUS_CHANGE | Definition for base term 3::686 MDC_EVT_COMM_STATUS_CHANGE is: 1. Communication status change 2. Communication Status Change |
urn:iso:std:iso:11073:10101 |
196831 ![]() |
MDC_EVT_COMPONENT_POSN_PROB | Definition for base term 3::222 MDC_EVT_COMPONENT_POSN_PROB is: 1. Supply or disposable positioning problem 2. Supply or disposable positioning problem. |
urn:iso:std:iso:11073:10101 |
197027 ![]() |
MDC_EVT_COMPUT_UNDERFLOW | Definition for base term 3::418 MDC_EVT_COMPUT_UNDERFLOW is: Underflow was detected in a measurement or calculation. |
urn:iso:std:iso:11073:10101 |
196751 ![]() |
MDC_EVT_CONFIG_ERR | Definition for base term 3::142 MDC_EVT_CONFIG_ERR is: 1. Device configuration: combination is not valid. 2. {SpO2} Connection not supported |
urn:iso:std:iso:11073:10101 |
196621 ![]() |
MDC_EVT_CONN | Definition for base term 3::12 MDC_EVT_CONN is: Connection |
urn:iso:std:iso:11073:10101 |
196833 ![]() |
MDC_EVT_CONNECTOR_SHORT | Definition for base term 3::224 MDC_EVT_CONNECTOR_SHORT is: 1. Connection short 2. Connector short. |
urn:iso:std:iso:11073:10101 |
196623 ![]() |
MDC_EVT_CONTAM | Definition for base term 3::14 MDC_EVT_CONTAM is: Contaminated |
urn:iso:std:iso:11073:10101 |
196835 ![]() |
MDC_EVT_CUFF_INCORRECT | Definition for base term 3::226 MDC_EVT_CUFF_INCORRECT is: 1. Incorrect Cuff 2. Incorrect NIBP cuff type |
urn:iso:std:iso:11073:10101 |
196841 ![]() |
MDC_EVT_CUFF_INFLAT_OVER | Definition for base term 3::232 MDC_EVT_CUFF_INFLAT_OVER is: 1. Cuff over inflated 2. {NBP} cuff over-inflated, i.e. cuff pressure high. |
urn:iso:std:iso:11073:10101 |
196837 ![]() |
MDC_EVT_CUFF_LEAK | Definition for base term 3::228 MDC_EVT_CUFF_LEAK is: Cuff leak |
urn:iso:std:iso:11073:10101 |
196849 ![]() |
MDC_EVT_CUFF_LOOSE | Definition for base term 3::240 MDC_EVT_CUFF_LOOSE is: Cuff loose |
urn:iso:std:iso:11073:10101 |
196839 ![]() |
MDC_EVT_CUFF_NOT_DEFLATED | Definition for base term 3::230 MDC_EVT_CUFF_NOT_DEFLATED is: 1. Cuff not fully deflated 2. {NBP} cuff not deflated. |
urn:iso:std:iso:11073:10101 |
197039 ![]() |
MDC_EVT_CUFF_POSN_ERR | Definition for base term 3::430 MDC_EVT_CUFF_POSN_ERR is: 1. Cuff improperly placed 2. {NBP} cuff has not been positioned correctly. |
urn:iso:std:iso:11073:10101 |
197091 ![]() |
MDC_EVT_DATA_ACQN_ERR | Definition for base term 3::482 MDC_EVT_DATA_ACQN_ERR is: 1. Unspecified problem in data acquisition 2. Unspecified problem in data acquisition. |
urn:iso:std:iso:11073:10101 |
196753 ![]() |
MDC_EVT_DATA_ACQN_PROB | Definition for base term 3::144 MDC_EVT_DATA_ACQN_PROB is: Unspecified problem in data acquisition |
urn:iso:std:iso:11073:10101 |
197377 ![]() |
MDC_EVT_DATA_INVALID | Definition for base term 3::768 MDC_EVT_DATA_INVALID is: Invalid data (for any reason, including missing data) |
urn:iso:std:iso:11073:10101 |
197379 ![]() |
MDC_EVT_DATA_MISSING | Definition for base term 3::770 MDC_EVT_DATA_MISSING is: Missing data (e.g., telemetry data dropouts) |
urn:iso:std:iso:11073:10101 |
196625 ![]() |
MDC_EVT_DEFECT | Definition for base term 3::16 MDC_EVT_DEFECT is: Defect is detected in a device, sensor, etc. |
urn:iso:std:iso:11073:10101 |
196627 ![]() |
MDC_EVT_DEPLET | Definition for base term 3::18 MDC_EVT_DEPLET is: An agent is detected as depleted in a device, sensor, etc |
urn:iso:std:iso:11073:10101 |
199855 ![]() |
MDC_EVT_DESAT | Definition for base term 3::3246 MDC_EVT_DESAT is: 1. Limit Event: Desaturation (escalated low oxygen alarm, used esp. in neonatal) 2. SpO2 Desaturation |
urn:iso:std:iso:11073:10101 |
196629 ![]() |
MDC_EVT_DETEC | Definition for base term 3::20 MDC_EVT_DETEC is: Some signal or special condition was detected. |
urn:iso:std:iso:11073:10101 |
197135 ![]() |
MDC_EVT_DEV_STAT_RPT | Definition for base term 3::526 MDC_EVT_DEV_STAT_RPT is: Device status report. |
urn:iso:std:iso:11073:10101 |
196631 ![]() |
MDC_EVT_DISCONN | Definition for base term 3::22 MDC_EVT_DISCONN is: 1. Disconnection, e.g., in sampling line 2. Disconnection, e.g., in sampling line. |
urn:iso:std:iso:11073:10101 |
197197 ![]() |
MDC_EVT_DISPOS_LO | Definition for base term 3::588 MDC_EVT_DISPOS_LO is: 1. Disposables low or out 2. Disposables low or out. |
urn:iso:std:iso:11073:10101 |
196633 ![]() |
MDC_EVT_DISTURB | Definition for base term 3::24 MDC_EVT_DISTURB is: 1. Signal is disturbed. 2. {Airway gas concentration} signal is disturbed. |
urn:iso:std:iso:11073:10101 |
196843 ![]() |
MDC_EVT_DOOR_OR_HANDLE_POSN_PROB | Definition for base term 3::234 MDC_EVT_DOOR_OR_HANDLE_POSN_PROB is: A door or handle which must be closed for proper operation is open. |
urn:iso:std:iso:11073:10101 |
197085 ![]() |
MDC_EVT_DOOR_POSN_ERR | Definition for base term 3::476 MDC_EVT_DOOR_POSN_ERR is: 1. A door or handle, which must be closed for operation, is open. 2. Door Open |
urn:iso:std:iso:11073:10101 |
199875 ![]() |
MDC_EVT_ECG_ARRHY | Definition for base term 3::3266 MDC_EVT_ECG_ARRHY is: Unspecified ECG (arrhythmia) event |
urn:iso:std:iso:11073:10101 |
199685 ![]() |
MDC_EVT_ECG_ASYSTOLE | Definition for base term 3::3076 MDC_EVT_ECG_ASYSTOLE is: No QRS-complex found in predefined time period |
urn:iso:std:iso:11073:10101 |
199737 ![]() |
MDC_EVT_ECG_ATR_FIB | Definition for base term 3::3128 MDC_EVT_ECG_ATR_FIB is: Atrial fibrillation |
urn:iso:std:iso:11073:10101 |
199885 ![]() |
MDC_EVT_ECG_ATR_FLUT | Definition for base term 3::3276 MDC_EVT_ECG_ATR_FLUT is: Atrial flutter |
urn:iso:std:iso:11073:10101 |
199739 ![]() |
MDC_EVT_ECG_ATR_P_C | Definition for base term 3::3130 MDC_EVT_ECG_ATR_P_C is: Premature atrial contraction |
urn:iso:std:iso:11073:10101 |
199741 ![]() |
MDC_EVT_ECG_ATR_PACING | Definition for base term 3::3132 MDC_EVT_ECG_ATR_PACING is: 1. Atrial Pacing 2. Atrial Pacing. |
urn:iso:std:iso:11073:10101 |
199743 ![]() |
MDC_EVT_ECG_ATR_STAND | Definition for base term 3::3134 MDC_EVT_ECG_ATR_STAND is: 1. Atrial standstill 2. Atrial Standstill. |
urn:iso:std:iso:11073:10101 |
199745 ![]() |
MDC_EVT_ECG_ATR_TACHY | Definition for base term 3::3136 MDC_EVT_ECG_ATR_TACHY is: Atrial tachycardia |
urn:iso:std:iso:11073:10101 |
199747 ![]() |
MDC_EVT_ECG_ATR_TACHY_MULTIFOCAL | Definition for base term 3::3138 MDC_EVT_ECG_ATR_TACHY_MULTIFOCAL is: 1. Atrial tachycardia multifocal 2. Atrial Tachycardia Multifocal |
urn:iso:std:iso:11073:10101 |
199749 ![]() |
MDC_EVT_ECG_ATR_TACHY_PAROX | Definition for base term 3::3140 MDC_EVT_ECG_ATR_TACHY_PAROX is: 1. Atrial tachycardia paroxysmal 2. Atrial Tachycardia Paroxysmal |
urn:iso:std:iso:11073:10101 |
199751 ![]() |
MDC_EVT_ECG_AV_DISSOC | Definition for base term 3::3142 MDC_EVT_ECG_AV_DISSOC is: 1. AV Disassociation 2. AV Dissociation |
urn:iso:std:iso:11073:10101 |
199755 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_1 | Definition for base term 3::3146 MDC_EVT_ECG_AV_HEART_BLK_DEG_1 is: 1. AV block 1°. 2. AV block 1° |
urn:iso:std:iso:11073:10101 |
199757 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2 | Definition for base term 3::3148 MDC_EVT_ECG_AV_HEART_BLK_DEG_2 is: 1. AV block 2°. 2. AV block 2° |
urn:iso:std:iso:11073:10101 |
199889 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2_1 | Definition for base term 3::3280 MDC_EVT_ECG_AV_HEART_BLK_DEG_2_1 is: 2:1 AV block |
urn:iso:std:iso:11073:10101 |
199759 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_I | Definition for base term 3::3150 MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_I is: 1. AV block 2, Type I 2. AV Heart Block Degree 2 Type I |
urn:iso:std:iso:11073:10101 |
199761 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_II | Definition for base term 3::3152 MDC_EVT_ECG_AV_HEART_BLK_DEG_2_TYPE_II is: 1. AV block 2, Type II 2. AV Heart Block Degree 2 Type II |
urn:iso:std:iso:11073:10101 |
199867 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_3 | Definition for base term 3::3258 MDC_EVT_ECG_AV_HEART_BLK_DEG_3 is: 1. AV block 3°. 2. AV block 3° |
urn:iso:std:iso:11073:10101 |
199891 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_3_1 | Definition for base term 3::3282 MDC_EVT_ECG_AV_HEART_BLK_DEG_3_1 is: 3:1 AV block |
urn:iso:std:iso:11073:10101 |
199897 ![]() |
MDC_EVT_ECG_AV_HEART_BLK_DEG_4_1 | Definition for base term 3::3288 MDC_EVT_ECG_AV_HEART_BLK_DEG_4_1 is: 4:1 AV block |
urn:iso:std:iso:11073:10101 |
199753 ![]() |
MDC_EVT_ECG_AV_PACING_SEQ | Definition for base term 3::3144 MDC_EVT_ECG_AV_PACING_SEQ is: AV Pacing Sequential |
urn:iso:std:iso:11073:10101 |
199763 ![]() |
MDC_EVT_ECG_BB_BLK | Definition for base term 3::3154 MDC_EVT_ECG_BB_BLK is: 1. Bundle Branch block 2. Bundle Branch Block |
urn:iso:std:iso:11073:10101 |
199687 ![]() |
MDC_EVT_ECG_BEAT_MISSED | Definition for base term 3::3078 MDC_EVT_ECG_BEAT_MISSED is: Missed beat within some regular ECG rhythm |
urn:iso:std:iso:11073:10101 |
199689 ![]() |
MDC_EVT_ECG_BEAT_UNUSUAL | Definition for base term 3::3080 MDC_EVT_ECG_BEAT_UNUSUAL is: 1. Unusual beat within some regular ECG rhythm 2. Unusual beat |
urn:iso:std:iso:11073:10101 |
199691 ![]() |
MDC_EVT_ECG_BIGEM | Definition for base term 3::3082 MDC_EVT_ECG_BIGEM is: 1. Ventricular bigemini: a specific rhythm 2. Ventricular bigeminy 3. Ventricular bigeminy: a specific rhythm |
urn:iso:std:iso:11073:10101 |
199695 ![]() |
MDC_EVT_ECG_BRADY_EXTREME | Definition for base term 3::3086 MDC_EVT_ECG_BRADY_EXTREME is: Limit Event: Extreme Bradycardia (escalated low HR limit, not a brady rhythm) |
urn:iso:std:iso:11073:10101 |
199697 ![]() |
MDC_EVT_ECG_BRADY_SUST | Definition for base term 3::3088 MDC_EVT_ECG_BRADY_SUST is: 1. Sustained Bradycardia 2. Sustained bradycardia. |
urn:iso:std:iso:11073:10101 |
199771 ![]() |
MDC_EVT_ECG_CARD_BEAT | Definition for base term 3::3162 MDC_EVT_ECG_CARD_BEAT is: 1. Heartbeat 2. [Heart] Beat |
urn:iso:std:iso:11073:10101 |
199765 ![]() |
MDC_EVT_ECG_CARD_BEAT_RATE_HI | Definition for base term 3::3156 MDC_EVT_ECG_CARD_BEAT_RATE_HI is: 1. High heart rate 2. High Heart Rate |
urn:iso:std:iso:11073:10101 |
199767 ![]() |
MDC_EVT_ECG_CARD_BEAT_RATE_IRREG | Definition for base term 3::3158 MDC_EVT_ECG_CARD_BEAT_RATE_IRREG is: Error Event: Irregular heart rate (which means the beat detector finds a highly variable heart rate and cannot derive a consistent/stable value) |
urn:iso:std:iso:11073:10101 |
199769 ![]() |
MDC_EVT_ECG_CARD_BEAT_RATE_LO | Definition for base term 3::3160 MDC_EVT_ECG_CARD_BEAT_RATE_LO is: 1. Low heart rate 2. Low Heart Rate |
urn:iso:std:iso:11073:10101 |
199701 ![]() |
MDC_EVT_ECG_FIB | Definition for base term 3::3092 MDC_EVT_ECG_FIB is: 1. Fibrillation (non-specific) 2. Fibrillation |
urn:iso:std:iso:11073:10101 |
199775 ![]() |
MDC_EVT_ECG_HEART_BLK | Definition for base term 3::3166 MDC_EVT_ECG_HEART_BLK is: 1. Heart block 2. Heart Block |
urn:iso:std:iso:11073:10101 |
199777 ![]() |
MDC_EVT_ECG_HEART_BLK_COMP | Definition for base term 3::3168 MDC_EVT_ECG_HEART_BLK_COMP is: 1. Complete Heart block 2. Heart Block Complete |
urn:iso:std:iso:11073:10101 |
199773 ![]() |
MDC_EVT_ECG_HEART_DYING | Definition for base term 3::3164 MDC_EVT_ECG_HEART_DYING is: 1. Dying heart 2. Dying Heart |
urn:iso:std:iso:11073:10101 |
199907 ![]() |
MDC_EVT_ECG_JUNC_ESC_BEATS | Definition for base term 3::3298 MDC_EVT_ECG_JUNC_ESC_BEATS is: 1. Junctional escape beats 2. Junctional Escape Beats. |
urn:iso:std:iso:11073:10101 |
199779 ![]() |
MDC_EVT_ECG_JUNC_P_C | Definition for base term 3::3170 MDC_EVT_ECG_JUNC_P_C is: 1. Junctional premature contraction 2. Premature Contraction, Junctional |
urn:iso:std:iso:11073:10101 |
199869 ![]() |
MDC_EVT_ECG_JUNC_RHY | Definition for base term 3::3260 MDC_EVT_ECG_JUNC_RHY is: Junctional rhythm |
urn:iso:std:iso:11073:10101 |
199781 ![]() |
MDC_EVT_ECG_JUNC_TACHY | Definition for base term 3::3172 MDC_EVT_ECG_JUNC_TACHY is: Junctional tachycardia |
urn:iso:std:iso:11073:10101 |
199783 ![]() |
MDC_EVT_ECG_JUNC_TACHY_PAROX | Definition for base term 3::3174 MDC_EVT_ECG_JUNC_TACHY_PAROX is: 1. Paroxysmal Junctional tachycardia 2. Paroxysmal supraventricular tachycardia |
urn:iso:std:iso:11073:10101 |
199909 ![]() |
MDC_EVT_ECG_JUNC_TACHY_RUN | Definition for base term 3::3300 MDC_EVT_ECG_JUNC_TACHY_RUN is: Run of junctional tachycardia |
urn:iso:std:iso:11073:10101 |
199785 ![]() |
MDC_EVT_ECG_LA_FASC_BLK | Definition for base term 3::3176 MDC_EVT_ECG_LA_FASC_BLK is: 1. Left Anterior Fascicular Block 2. Fascicular Block. LA. |
urn:iso:std:iso:11073:10101 |
199787 ![]() |
MDC_EVT_ECG_LBB_BLK | Definition for base term 3::3178 MDC_EVT_ECG_LBB_BLK is: 1. Left Bundle Branch block 2. Left Bundle Branch Block |
urn:iso:std:iso:11073:10101 |
199789 ![]() |
MDC_EVT_ECG_LP_FASC_BLK | Definition for base term 3::3180 MDC_EVT_ECG_LP_FASC_BLK is: 1. Left Posterior Fascicular Block 2. Fascicular Block. LP |
urn:iso:std:iso:11073:10101 |
199703 ![]() |
MDC_EVT_ECG_NO_ECT_BEAT | Definition for base term 3::3094 MDC_EVT_ECG_NO_ECT_BEAT is: 1. No Ectopic beat 2. No ectopic beat |
urn:iso:std:iso:11073:10101 |
199683 ![]() |
MDC_EVT_ECG_NOT_PACED | Definition for base term 3::3074 MDC_EVT_ECG_NOT_PACED is: 1. Beat not paced 2. No pacer detected |
urn:iso:std:iso:11073:10101 |
199705 ![]() |
MDC_EVT_ECG_PACED_BEAT | Definition for base term 3::3096 MDC_EVT_ECG_PACED_BEAT is: Pacer pulse sensed by heart |
urn:iso:std:iso:11073:10101 |
199895 ![]() |
MDC_EVT_ECG_PACER_ABSENT | Definition for base term 3::3286 MDC_EVT_ECG_PACER_ABSENT is: No pacer detected |
urn:iso:std:iso:11073:10101 |
199903 ![]() |
MDC_EVT_ECG_PACER_ARTIF_RECOG | Definition for base term 3::3294 MDC_EVT_ECG_PACER_ARTIF_RECOG is: Pacer artifact recognized |
urn:iso:std:iso:11073:10101 |
199791 ![]() |
MDC_EVT_ECG_PACER_NOT_PACING | Definition for base term 3::3182 MDC_EVT_ECG_PACER_NOT_PACING is: Pacer (device) not sensing |
urn:iso:std:iso:11073:10101 |
199709 ![]() |
MDC_EVT_ECG_PACING_CAPT | Definition for base term 3::3100 MDC_EVT_ECG_PACING_CAPT is: 1. Pacing captured (recognized by heart) 2. Pacing capture |
urn:iso:std:iso:11073:10101 |
199711 ![]() |
MDC_EVT_ECG_PACING_NON_CAPT | Definition for base term 3::3102 MDC_EVT_ECG_PACING_NON_CAPT is: 1. Pacer not captured (not recognized by heart) 2. Pacing not captured (not recognized by heart) |
urn:iso:std:iso:11073:10101 |
199713 ![]() |
MDC_EVT_ECG_PACING_RUN | Definition for base term 3::3104 MDC_EVT_ECG_PACING_RUN is: 1. Run of paced beats 2. Pacing Run |
urn:iso:std:iso:11073:10101 |
199715 ![]() |
MDC_EVT_ECG_PATT | Definition for base term 3::3106 MDC_EVT_ECG_PATT is: Unspecified ECG (arrhythmia) event |
urn:iso:std:iso:11073:10101 |
199717 ![]() |
MDC_EVT_ECG_PAUSE | Definition for base term 3::3108 MDC_EVT_ECG_PAUSE is: 1. Prolonged RR interval, due to any reason 2. Pause |
urn:iso:std:iso:11073:10101 |
199793 ![]() |
MDC_EVT_ECG_PT_NOT_PACED | Definition for base term 3::3184 MDC_EVT_ECG_PT_NOT_PACED is: 1. Patient not paced 2. Patient Not Paced |
urn:iso:std:iso:11073:10101 |
199719 ![]() |
MDC_EVT_ECG_QUADRIGEM | Definition for base term 3::3110 MDC_EVT_ECG_QUADRIGEM is: Quadrigeminy |
urn:iso:std:iso:11073:10101 |
199795 ![]() |
MDC_EVT_ECG_RBB_BLK | Definition for base term 3::3186 MDC_EVT_ECG_RBB_BLK is: 1. Right Bundle Branch block 2. Right Bundle Branch Block |
urn:iso:std:iso:11073:10101 |
199721 ![]() |
MDC_EVT_ECG_RHY | Definition for base term 3::3112 MDC_EVT_ECG_RHY is: Rhythm |
urn:iso:std:iso:11073:10101 |
199723 ![]() |
MDC_EVT_ECG_RHY_ABSENT | Definition for base term 3::3114 MDC_EVT_ECG_RHY_ABSENT is: No [cardiac] rhythm |
urn:iso:std:iso:11073:10101 |
199881 ![]() |
MDC_EVT_ECG_RHY_CPLT | Definition for base term 3::3272 MDC_EVT_ECG_RHY_CPLT is: Couplet |
urn:iso:std:iso:11073:10101 |
199725 ![]() |
MDC_EVT_ECG_RHY_ECT | Definition for base term 3::3116 MDC_EVT_ECG_RHY_ECT is: Ectopic rhythm |
urn:iso:std:iso:11073:10101 |
199727 ![]() |
MDC_EVT_ECG_RR_IRREG | Definition for base term 3::3118 MDC_EVT_ECG_RR_IRREG is: Irregular rhythm |
urn:iso:std:iso:11073:10101 |
199693 ![]() |
MDC_EVT_ECG_SINUS_BRADY | Definition for base term 3::3084 MDC_EVT_ECG_SINUS_BRADY is: 1. Bradycardia 2. Sinus bradycardia |
urn:iso:std:iso:11073:10101 |
199871 ![]() |
MDC_EVT_ECG_SINUS_TACHY | Definition for base term 3::3262 MDC_EVT_ECG_SINUS_TACHY is: Sinus tachycardia |
urn:iso:std:iso:11073:10101 |
199849 ![]() |
MDC_EVT_ECG_STAT_ECT | Definition for base term 3::3240 MDC_EVT_ECG_STAT_ECT is: 1. Current ectopic rhythm status: conveys an enumerated summary of the predominant ECG ectopic rhythm type(s) over the reporting time interval 2. Present ectopic arrhythmia type; "present" implies user-defined time-constant (e.g. within last minute). |
urn:iso:std:iso:11073:10101 |
199851 ![]() |
MDC_EVT_ECG_STAT_RHY | Definition for base term 3::3242 MDC_EVT_ECG_STAT_RHY is: 1. Current rhythm status: conveys an enumerated summary of the predominant ECG rhythm type(s) over the reporting time interval 2. Present rhythm; "present" implies user-defined time-constant (e.g. within last minute) |
urn:iso:std:iso:11073:10101 |
199797 ![]() |
MDC_EVT_ECG_SV_BEAT | Definition for base term 3::3188 MDC_EVT_ECG_SV_BEAT is: 1. Supraventricular beat 2. SV Beat |
urn:iso:std:iso:11073:10101 |
199799 ![]() |
MDC_EVT_ECG_SV_P_C | Definition for base term 3::3190 MDC_EVT_ECG_SV_P_C is: Supraventricular extrasystole |
urn:iso:std:iso:11073:10101 |
199899 ![]() |
MDC_EVT_ECG_SV_P_C_FREQ | Definition for base term 3::3290 MDC_EVT_ECG_SV_P_C_FREQ is: Frequent supraventricular extrasystoles |
urn:iso:std:iso:11073:10101 |
199857 ![]() |
MDC_EVT_ECG_SV_P_C_RUN | Definition for base term 3::3248 MDC_EVT_ECG_SV_P_C_RUN is: Several consecutive supraventricular extrasystoles |
urn:iso:std:iso:11073:10101 |
199801 ![]() |
MDC_EVT_ECG_SV_TACHY | Definition for base term 3::3192 MDC_EVT_ECG_SV_TACHY is: Supraventricular tachycardia |
urn:iso:std:iso:11073:10101 |
199729 ![]() |
MDC_EVT_ECG_TACHY | Definition for base term 3::3120 MDC_EVT_ECG_TACHY is: Tachycardia |
urn:iso:std:iso:11073:10101 |
199731 ![]() |
MDC_EVT_ECG_TACHY_EXTREME | Definition for base term 3::3122 MDC_EVT_ECG_TACHY_EXTREME is: Limit Event: Extreme Tachycardia (escalated high HR limit, not a tachy rhythm) |
urn:iso:std:iso:11073:10101 |
199733 ![]() |
MDC_EVT_ECG_TACHY_UNSPEC | Definition for base term 3::3124 MDC_EVT_ECG_TACHY_UNSPEC is: 1. Tacycardia (unspecified) 2. Tachycardia Unspecified |
urn:iso:std:iso:11073:10101 |
199735 ![]() |
MDC_EVT_ECG_TRIGEM | Definition for base term 3::3126 MDC_EVT_ECG_TRIGEM is: 1. Ventricular trigeminy 2. Trigeminy |
urn:iso:std:iso:11073:10101 |
199805 ![]() |
MDC_EVT_ECG_V_BIGEM | Definition for base term 3::3196 MDC_EVT_ECG_V_BIGEM is: 1. Ventricular bigeminy 2. Ventriclular bigeminy |
urn:iso:std:iso:11073:10101 |
199807 ![]() |
MDC_EVT_ECG_V_FIB | Definition for base term 3::3198 MDC_EVT_ECG_V_FIB is: Ventricular fibrillation |
urn:iso:std:iso:11073:10101 |
199811 ![]() |
MDC_EVT_ECG_V_FLUT | Definition for base term 3::3202 MDC_EVT_ECG_V_FLUT is: Ventricular flutter |
urn:iso:std:iso:11073:10101 |
199813 ![]() |
MDC_EVT_ECG_V_P_C | Definition for base term 3::3204 MDC_EVT_ECG_V_P_C is: Premature ventricular contraction |
urn:iso:std:iso:11073:10101 |
199883 ![]() |
MDC_EVT_ECG_V_P_C_FREQ | Definition for base term 3::3274 MDC_EVT_ECG_V_P_C_FREQ is: Frequent premature ventricular contractions |
urn:iso:std:iso:11073:10101 |
199817 ![]() |
MDC_EVT_ECG_V_P_C_MULTIFORM | Definition for base term 3::3208 MDC_EVT_ECG_V_P_C_MULTIFORM is: Multiformed premature ventricular contractions |
urn:iso:std:iso:11073:10101 |
199819 ![]() |
MDC_EVT_ECG_V_P_C_PAIR | Definition for base term 3::3210 MDC_EVT_ECG_V_P_C_PAIR is: Pair of premature ventricular contractions |
urn:iso:std:iso:11073:10101 |
199861 ![]() |
MDC_EVT_ECG_V_P_C_RATE | Definition for base term 3::3252 MDC_EVT_ECG_V_P_C_RATE is: A specific limit alert on the PVC rate |
urn:iso:std:iso:11073:10101 |
199815 ![]() |
MDC_EVT_ECG_V_P_C_RonT | Definition for base term 3::3206 MDC_EVT_ECG_V_P_C_RonT is: Premature ventricular contraction, R-on-T |
urn:iso:std:iso:11073:10101 |
199821 ![]() |
MDC_EVT_ECG_V_P_C_RUN | Definition for base term 3::3212 MDC_EVT_ECG_V_P_C_RUN is: Several consecutive ventricular extrasystoles |
urn:iso:std:iso:11073:10101 |
199823 ![]() |
MDC_EVT_ECG_V_P_C_TRIP | Definition for base term 3::3214 MDC_EVT_ECG_V_P_C_TRIP is: VPC Triplet |
urn:iso:std:iso:11073:10101 |
199825 ![]() |
MDC_EVT_ECG_V_PACING | Definition for base term 3::3216 MDC_EVT_ECG_V_PACING is: 1. Ventricular Pacing 2. Ventricular pacing |
urn:iso:std:iso:11073:10101 |
199803 ![]() |
MDC_EVT_ECG_V_PARASYS | Definition for base term 3::3194 MDC_EVT_ECG_V_PARASYS is: Ventricular parasystole |
urn:iso:std:iso:11073:10101 |
199827 ![]() |
MDC_EVT_ECG_V_QUADRIGEM | Definition for base term 3::3218 MDC_EVT_ECG_V_QUADRIGEM is: 1. Ventricular quadrigeminy 2. Ventricular Quadrigeminy |
urn:iso:std:iso:11073:10101 |
199829 ![]() |
MDC_EVT_ECG_V_RHY | Definition for base term 3::3220 MDC_EVT_ECG_V_RHY is: Ventricular rhythm: escalation of Run of PVC, not yet flutter |
urn:iso:std:iso:11073:10101 |
199831 ![]() |
MDC_EVT_ECG_V_STAND | Definition for base term 3::3222 MDC_EVT_ECG_V_STAND is: 1. Ventricular standstill 2. Ventricular Standstill |
urn:iso:std:iso:11073:10101 |
199833 ![]() |
MDC_EVT_ECG_V_TACHY | Definition for base term 3::3224 MDC_EVT_ECG_V_TACHY is: Ventricular tachycardia |
urn:iso:std:iso:11073:10101 |
199835 ![]() |
MDC_EVT_ECG_V_TACHY_NON_SUST | Definition for base term 3::3226 MDC_EVT_ECG_V_TACHY_NON_SUST is: 1. Ventricular tachycardia, Non-sustained 2. Ventricular Tachycardia, Non-sustained |
urn:iso:std:iso:11073:10101 |
199841 ![]() |
MDC_EVT_ECG_V_TACHY_RHY | Definition for base term 3::3232 MDC_EVT_ECG_V_TACHY_RHY is: 1. Ventricular tachycardia Rhythm 2. Ventricular Tachycardia Rhythm |
urn:iso:std:iso:11073:10101 |
199843 ![]() |
MDC_EVT_ECG_V_TACHY_RHY_SUST | Definition for base term 3::3234 MDC_EVT_ECG_V_TACHY_RHY_SUST is: 1. Ventricular tachycardia Rhythm, Sustained 2. Vent Tachycardia Rhythm, Sustained |
urn:iso:std:iso:11073:10101 |
199837 ![]() |
MDC_EVT_ECG_V_TACHY_SUST | Definition for base term 3::3228 MDC_EVT_ECG_V_TACHY_SUST is: 1. Ventricular tachycardia, Sustained 2. Ventricular Tachycardia, Sustained |
urn:iso:std:iso:11073:10101 |
199839 ![]() |
MDC_EVT_ECG_V_TACHY_TORSADE | Definition for base term 3::3230 MDC_EVT_ECG_V_TACHY_TORSADE is: 1. Ventricular tachycardia, Torsades de Pointes 2. Torsades de Pointes |
urn:iso:std:iso:11073:10101 |
199845 ![]() |
MDC_EVT_ECG_V_TRIGEM | Definition for base term 3::3236 MDC_EVT_ECG_V_TRIGEM is: 1. Ventricular trigemini: a specific rhythm 2. Ventricular trigeminy 3. Ventricular trigeminy: a specific rhythm |
urn:iso:std:iso:11073:10101 |
199847 ![]() |
MDC_EVT_ECG_V_TRIGEM_RHY | Definition for base term 3::3238 MDC_EVT_ECG_V_TRIGEM_RHY is: 1. Ventricular trigeminy rhythm 2. Ventricular Trigeminy Rhythm |
urn:iso:std:iso:11073:10101 |
199913 ![]() |
MDC_EVT_EEG_BACK_ACTIV_ABSENT | Definition for base term 3::3304 MDC_EVT_EEG_BACK_ACTIV_ABSENT is: Back Activity Absent |
urn:iso:std:iso:11073:10101 |
199877 ![]() |
MDC_EVT_EEG_DISCHG_EPILEPTIFORM | Definition for base term 3::3268 MDC_EVT_EEG_DISCHG_EPILEPTIFORM is: Epileptiform discharges in EEG |
urn:iso:std:iso:11073:10101 |
199873 ![]() |
MDC_EVT_EEG_DISCHG_SEIZ_CLIN | Definition for base term 3::3264 MDC_EVT_EEG_DISCHG_SEIZ_CLIN is: Clinical seizure discharge in EEG |
urn:iso:std:iso:11073:10101 |
199863 ![]() |
MDC_EVT_EEG_SPK_AND_WV | Definition for base term 3::3254 MDC_EVT_EEG_SPK_AND_WV is: Spikes and waves in EEG |
urn:iso:std:iso:11073:10101 |
199879 ![]() |
MDC_EVT_EEG_SPK_SHARP | Definition for base term 3::3270 MDC_EVT_EEG_SPK_SHARP is: Sharp spikes in EEG |
urn:iso:std:iso:11073:10101 |
196845 ![]() |
MDC_EVT_ELEC_PWR_LINE_PROB | Definition for base term 3::236 MDC_EVT_ELEC_PWR_LINE_PROB is: 1. Electric power line: unspecified problem 2. Electric power line: unspecified problem. |
urn:iso:std:iso:11073:10101 |
197341 ![]() |
MDC_EVT_EMER_STOP | Definition for base term 3::732 MDC_EVT_EMER_STOP is: Emergency Stop |
urn:iso:std:iso:11073:10101 |
196635 ![]() |
MDC_EVT_EMPTY | Definition for base term 3::26 MDC_EVT_EMPTY is: A reservoir, etc., is empty. |
urn:iso:std:iso:11073:10101 |
196847 ![]() |
MDC_EVT_ENDOTRACH_TUBE_LEAK | Definition for base term 3::238 MDC_EVT_ENDOTRACH_TUBE_LEAK is: 1. Endotracheal tube leak (ventilator) 2. Endotracheal tube leak (ventilator). |
urn:iso:std:iso:11073:10101 |
197171 ![]() |
MDC_EVT_ENVIRON | Definition for base term 3::562 MDC_EVT_ENVIRON is: 1. Unspecified device environment warning 2. Unspecified environment(al) event. |
urn:iso:std:iso:11073:10101 |
196637 ![]() |
MDC_EVT_EQU | Definition for base term 3::28 MDC_EVT_EQU is: 1. Unspecified device error 2. Unspecified device error. |
urn:iso:std:iso:11073:10101 |
199911 ![]() |
MDC_EVT_EQU_HR_AND_PR | Definition for base term 3::3302 MDC_EVT_EQU_HR_AND_PR is: Cardiac and Pulse Rates are equal |
urn:iso:std:iso:11073:10101 |
197199 ![]() |
MDC_EVT_EQUIP | Definition for base term 3::590 MDC_EVT_EQUIP is: 1. Unspecified equipment event 2. Unspecified Equipment event. |
urn:iso:std:iso:11073:10101 |
196851 ![]() |
MDC_EVT_EQUIP_MALF | Definition for base term 3::242 MDC_EVT_EQUIP_MALF is: 1. Unspecified device malfunction error warning 2. {ECG} equipment malfunction. |
urn:iso:std:iso:11073:10101 |
196639 ![]() |
MDC_EVT_ERR | Definition for base term 3::30 MDC_EVT_ERR is: 1. Error condition is detected 2. Problem in power supply module. |
urn:iso:std:iso:11073:10101 |
199905 ![]() |
MDC_EVT_ERR_EQU_HR_AND_RR | Definition for base term 3::3296 MDC_EVT_ERR_EQU_HR_AND_RR is: 1. Heart rate and respiration rate are reported to be the same value. 2. Cardiac and Respiration Rates are reported to be equal. |
urn:iso:std:iso:11073:10101 |
196641 ![]() |
MDC_EVT_ERRATIC | Definition for base term 3::32 MDC_EVT_ERRATIC is: Erratic condition is detected. |
urn:iso:std:iso:11073:10101 |
196643 ![]() |
MDC_EVT_EXCESS | Definition for base term 3::34 MDC_EVT_EXCESS is: 1. A reservoir, etc., has excess content 2. Excess(ive) [NOS]. |
urn:iso:std:iso:11073:10101 |
196645 ![]() |
MDC_EVT_EXH | Definition for base term 3::36 MDC_EVT_EXH is: 1. A consumable is exhausted 2. Exhausted. |
urn:iso:std:iso:11073:10101 |
196647 ![]() |
MDC_EVT_FAIL | Definition for base term 3::38 MDC_EVT_FAIL is: An action, data transmission, etc., failed. |
urn:iso:std:iso:11073:10101 |
197129 ![]() |
MDC_EVT_FLOW_DISTURB | Definition for base term 3::520 MDC_EVT_FLOW_DISTURB is: 1. Flow is disturbed 2. {Pump} flow impediment. |
urn:iso:std:iso:11073:10101 |
197191 ![]() |
MDC_EVT_FLOW_FLUID_LINE_RES_WARN | Definition for base term 3::582 MDC_EVT_FLOW_FLUID_LINE_RES_WARN is: 1. Advisory: Flow resistance warning 2. Flow resistance warning. |
urn:iso:std:iso:11073:10101 |
196951 ![]() |
MDC_EVT_FLOW_LO | Definition for base term 3::342 MDC_EVT_FLOW_LO is: 1. Flow is low 2. {Pump} flow low. |
urn:iso:std:iso:11073:10101 |
197185 ![]() |
MDC_EVT_FLOW_OBSTRUC | Definition for base term 3::576 MDC_EVT_FLOW_OBSTRUC is: 1. Flow is obstructed. 2. {Pump} flow is hindered. |
urn:iso:std:iso:11073:10101 |
196953 ![]() |
MDC_EVT_FLOW_REVERSED | Definition for base term 3::344 MDC_EVT_FLOW_REVERSED is: 1. Flow is reversed 2. {Ventilator} reverse flow (not specific to inspiratory or expiratory limb). |
urn:iso:std:iso:11073:10101 |
197345 ![]() |
MDC_EVT_FLOW_STOP_OPEN | Definition for base term 3::736 MDC_EVT_FLOW_STOP_OPEN is: Flow stop valve is open |
urn:iso:std:iso:11073:10101 |
197201 ![]() |
MDC_EVT_FLUID_LINE_AIR | Definition for base term 3::592 MDC_EVT_FLUID_LINE_AIR is: Air in fluid line. |
urn:iso:std:iso:11073:10101 |
196853 ![]() |
MDC_EVT_FLUID_LINE_DISTURB | Definition for base term 3::244 MDC_EVT_FLUID_LINE_DISTURB is: 1. Flow disturbance 2. Pump flow disturbance. |
urn:iso:std:iso:11073:10101 |
196955 ![]() |
MDC_EVT_FLUID_LINE_DRIP_MALF | Definition for base term 3::346 MDC_EVT_FLUID_LINE_DRIP_MALF is: 1. Error in drip counting measurement 2. Error in drip counting measurement. |
urn:iso:std:iso:11073:10101 |
196863 ![]() |
MDC_EVT_FLUID_LINE_FLOW_SENSOR_PROB | Definition for base term 3::254 MDC_EVT_FLUID_LINE_FLOW_SENSOR_PROB is: 1. Flow sensor problem 2. Flow sensor problem. |
urn:iso:std:iso:11073:10101 |
197189 ![]() |
MDC_EVT_FLUID_LINE_HI_GT_LIM_PRESSURE | Definition for base term 3::580 MDC_EVT_FLUID_LINE_HI_GT_LIM_PRESSURE is: 1. High pressure in fluid line 2. Too much pressure in line. |
urn:iso:std:iso:11073:10101 |
196855 ![]() |
MDC_EVT_FLUID_LINE_INFILT | Definition for base term 3::246 MDC_EVT_FLUID_LINE_INFILT is: 1. Infiltration of fluid line 2. Infiltration of fluid line. |
urn:iso:std:iso:11073:10101 |
196857 ![]() |
MDC_EVT_FLUID_LINE_INGRESS | Definition for base term 3::248 MDC_EVT_FLUID_LINE_INGRESS is: 1. Ingress in fluid line 2. Fluid line ingress. |
urn:iso:std:iso:11073:10101 |
196941 ![]() |
MDC_EVT_FLUID_LINE_OCCL | Definition for base term 3::332 MDC_EVT_FLUID_LINE_OCCL is: Occlusion of fluid line. |
urn:iso:std:iso:11073:10101 |
196861 ![]() |
MDC_EVT_FLUID_LINE_PROB | Definition for base term 3::252 MDC_EVT_FLUID_LINE_PROB is: 1. Problem in fluid line 2. Problem in fluid line. |
urn:iso:std:iso:11073:10101 |
197081 ![]() |
MDC_EVT_FRAM_ERR | Definition for base term 3::472 MDC_EVT_FRAM_ERR is: 1. Communication error: framing error 2. Communication error: framing error. |
urn:iso:std:iso:11073:10101 |
196755 ![]() |
MDC_EVT_FUNC_UNAVAIL | Definition for base term 3::146 MDC_EVT_FUNC_UNAVAIL is: A resource is not available. |
urn:iso:std:iso:11073:10101 |
196757 ![]() |
MDC_EVT_GAIN_HI | Definition for base term 3::148 MDC_EVT_GAIN_HI is: 1. Signal gain high: probably erroneous data extraction 2. Gain high. |
urn:iso:std:iso:11073:10101 |
196759 ![]() |
MDC_EVT_GAIN_LO | Definition for base term 3::150 MDC_EVT_GAIN_LO is: 1. Signal gain low: probably erroneous data extraction 2. Gain low. |
urn:iso:std:iso:11073:10101 |
196867 ![]() |
MDC_EVT_GAS_AGENT_IDENT_MALF | Definition for base term 3::258 MDC_EVT_GAS_AGENT_IDENT_MALF is: 1. Gas agent identification malfunction 2. Gas agent identification malfunction. |
urn:iso:std:iso:11073:10101 |
196865 ![]() |
MDC_EVT_GAS_CONTAM | Definition for base term 3::256 MDC_EVT_GAS_CONTAM is: Gas contamination |
urn:iso:std:iso:11073:10101 |
196869 ![]() |
MDC_EVT_GAS_LINE_PROB | Definition for base term 3::260 MDC_EVT_GAS_LINE_PROB is: 1. Gas line problem 2. Gas line problem (with the breathing system). |
urn:iso:std:iso:11073:10101 |
196761 ![]() |
MDC_EVT_HANDL_ERR | Definition for base term 3::152 MDC_EVT_HANDL_ERR is: 1. Not specified, unnormal handling of a device, device component, cabling, or transducer 2. Not specified, unnormal handling of a device, device component, cabling, or transducer. |
urn:iso:std:iso:11073:10101 |
197355 ![]() |
MDC_EVT_HANDSET_DETACHED | Definition for base term 3::746 MDC_EVT_HANDSET_DETACHED is: 1. Advisory: Handset detached 2. {*} Handset is detached from unit |
urn:iso:std:iso:11073:10101 |
196871 ![]() |
MDC_EVT_HEATING_PWR_PROB | Definition for base term 3::262 MDC_EVT_HEATING_PWR_PROB is: 1. Heater power problem 2. Heating Power problem. |
urn:iso:std:iso:11073:10101 |
196649 ![]() |
MDC_EVT_HI | Definition for base term 3::40 MDC_EVT_HI is: {numeric observation} > high limit |
urn:iso:std:iso:11073:10101 |
196651 ![]() |
MDC_EVT_HI_GT_LIM | Definition for base term 3::42 MDC_EVT_HI_GT_LIM is: A metric exceeds a given threshold |
urn:iso:std:iso:11073:10101 |
196653 ![]() |
MDC_EVT_HI_VAL_GT_LIM | Definition for base term 3::44 MDC_EVT_HI_VAL_GT_LIM is: A metric exceeds a given threshold. |
urn:iso:std:iso:11073:10101 |
196873 ![]() |
MDC_EVT_HOSE_LEAK | Definition for base term 3::264 MDC_EVT_HOSE_LEAK is: 1. Leak in hose within breathing system 2. Leak in breathing system. |
urn:iso:std:iso:11073:10101 |
196875 ![]() |
MDC_EVT_HOSE_OBSTRUC | Definition for base term 3::266 MDC_EVT_HOSE_OBSTRUC is: 1. Flow in hose is obstructed 2. (Ventilator) hose obstructed. |
urn:iso:std:iso:11073:10101 |
197099 ![]() |
MDC_EVT_HUMID_EXCESS | Definition for base term 3::490 MDC_EVT_HUMID_EXCESS is: 1. Too much humidity for accurate measurement 2. Too much humidity for accurate measurement. |
urn:iso:std:iso:11073:10101 |
197187 ![]() |
MDC_EVT_HUMID_HI_ERR | Definition for base term 3::578 MDC_EVT_HUMID_HI_ERR is: 1. Too much humidity for accurate measurement 2. Too much humidity for accurate measurement. |
urn:iso:std:iso:11073:10101 |
197329 ![]() |
MDC_EVT_IDLE | Definition for base term 3::720 MDC_EVT_IDLE is: 1. Idle state of, e.g., device 2. Idle state of, e.g., {pump} device |
urn:iso:std:iso:11073:10101 |
197209 ![]() |
MDC_EVT_INCOMPAT | Definition for base term 3::600 MDC_EVT_INCOMPAT is: 1. Incompatibility of nomenclature or processing component, etc. 2. This version of the {NMT} measurement module is not supported, or the module firmware is incomplete and needs to be upgraded. |
urn:iso:std:iso:11073:10101 |
196655 ![]() |
MDC_EVT_INCORRECT | Definition for base term 3::46 MDC_EVT_INCORRECT is: 1. Incorrect result of a calculation, e.g., CRC in data transmission, of a data structure, etc., detected 2. Incorrect result of a calculation, e.g., CRC in data transmission, of a data structure, etc., detected. |
urn:iso:std:iso:11073:10101 |
196657 ![]() |
MDC_EVT_INFILT | Definition for base term 3::48 MDC_EVT_INFILT is: 1. Infiltration NOS 2. Infiltration [NOS]. |
urn:iso:std:iso:11073:10101 |
196763 ![]() |
MDC_EVT_INFLAT_OVER | Definition for base term 3::154 MDC_EVT_INFLAT_OVER is: 1. Over inflated (non-specific) 2. Over-inflated. |
urn:iso:std:iso:11073:10101 |
196659 ![]() |
MDC_EVT_INGRESS | Definition for base term 3::50 MDC_EVT_INGRESS is: 1. Ingress of contaminant NOS 2. Ingress [NOS]. |
urn:iso:std:iso:11073:10101 |
196661 ![]() |
MDC_EVT_INOP | Definition for base term 3::52 MDC_EVT_INOP is: 1. (Un)intentional inoperable condition NOS 2. (Un)intentional inoperable condition. |
urn:iso:std:iso:11073:10101 |
196957 ![]() |
MDC_EVT_INTENS_ERR | Definition for base term 3::348 MDC_EVT_INTENS_ERR is: 1. Error Event: Radiation source intensity incorrect 2. Intensity error (NOS). |
urn:iso:std:iso:11073:10101 |
196959 ![]() |
MDC_EVT_INTENS_LIGHT_ERR | Definition for base term 3::350 MDC_EVT_INTENS_LIGHT_ERR is: 1. Error Event: Light source intensity incorrect 2. Light Intensity error. |
urn:iso:std:iso:11073:10101 |
196663 ![]() |
MDC_EVT_INTERF | Definition for base term 3::54 MDC_EVT_INTERF is: 1. Interference NOS 2. Interference [NOS]. |
urn:iso:std:iso:11073:10101 |
196665 ![]() |
MDC_EVT_INTERRUP | Definition for base term 3::56 MDC_EVT_INTERRUP is: A measurement, process, or data transmission was interrupted. |
urn:iso:std:iso:11073:10101 |
196667 ![]() |
MDC_EVT_IRREG | Definition for base term 3::58 MDC_EVT_IRREG is: Irregular rhythm or waveform in a signal, etc. |
urn:iso:std:iso:11073:10101 |
196877 ![]() |
MDC_EVT_LEAD_DISCONN | Definition for base term 3::268 MDC_EVT_LEAD_DISCONN is: 1. Error Event: (ECG) Lead Disconnected (specialized form of the generic disconnect event. In case of ECG, some ECG devices reconstruct leads when a single lead of a multilead cable falls off. This needs a special user notification, because the situation might not be visible on the display waves. Reasoning: see above.) 2. Error Event: {ECG} Lead Disconnected (specialized form of the generic disconnect event). [In the case of ECG, some ECG devices reconstruct leads when a single lead of a multilead cable falls off. This needs a special user notification, because the situation might not be visible on the display waves. Reasoning: see above.] |
urn:iso:std:iso:11073:10101 |
196879 ![]() |
MDC_EVT_LEAD_NOISY | Definition for base term 3::270 MDC_EVT_LEAD_NOISY is: 1. Error Event: (ECG) Lead Noisy 2. {ECG} lead data is invalid due to excessive signal noise, bad electrode contact, interference from external devices and/or incorrect {ST} lead selection(s). |
urn:iso:std:iso:11073:10101 |
196881 ![]() |
MDC_EVT_LEAD_OFF | Definition for base term 3::272 MDC_EVT_LEAD_OFF is: 1. Error Event: (ECG) Lead Disconnected 2. {ECG} Lead off |
urn:iso:std:iso:11073:10101 |
196883 ![]() |
MDC_EVT_LEADS_OFF | Definition for base term 3::274 MDC_EVT_LEADS_OFF is: 1. Error Event: (ECG) Leads Disconnected 2. One or more {ECG} leads are not attached to the patient. |
urn:iso:std:iso:11073:10101 |
196669 ![]() |
MDC_EVT_LEAK | Definition for base term 3::60 MDC_EVT_LEAK is: 1. Leakage in a gas or fluid filled system detected 2. Leakage in a gas or fluid filled system detected. |
urn:iso:std:iso:11073:10101 |
196887 ![]() |
MDC_EVT_LIGHT_INTERF | Definition for base term 3::278 MDC_EVT_LIGHT_INTERF is: 1. Error Event: Light Interference (SpO2 measurement, special kind of interference) 2. {SpO2} Regulation error: an excessive amount of ambient light is present, giving low amplitude and inaccurate readings as a result. |
urn:iso:std:iso:11073:10101 |
197093 ![]() |
MDC_EVT_LIGHT_ON | Definition for base term 3::484 MDC_EVT_LIGHT_ON is: 1. Error Event: Lights in the (sleep measurement) room are switched on {status lights on/off} 2. Lights in the {sleep measurement} room are switched on (or device status or illumination lights are on). |
urn:iso:std:iso:11073:10101 |
196889 ![]() |
MDC_EVT_LIGHT_SRC_ABSENT | Definition for base term 3::280 MDC_EVT_LIGHT_SRC_ABSENT is: 1. Error Event: Light source absent 2. Light source absent or missing. |
urn:iso:std:iso:11073:10101 |
196885 ![]() |
MDC_EVT_LIGHTS_IN_ROOM_OFF | Definition for base term 3::276 MDC_EVT_LIGHTS_IN_ROOM_OFF is: 1. Lights in the (sleep measurement) room are switched off. 2. Lights in the {sleep measurement} room are switched off. |
urn:iso:std:iso:11073:10101 |
197059 ![]() |
MDC_EVT_LIMIT_AL_HI | Definition for base term 3::450 MDC_EVT_LIMIT_AL_HI is: A metric exceeds a given threshold. |
urn:iso:std:iso:11073:10101 |
197163 ![]() |
MDC_EVT_LIMIT_AL_LO | Definition for base term 3::554 MDC_EVT_LIMIT_AL_LO is: A metric falls short of a given threshold. |
urn:iso:std:iso:11073:10101 |
196671 ![]() |
MDC_EVT_LO | Definition for base term 3::62 MDC_EVT_LO is: {numeric observation} < low limit |
urn:iso:std:iso:11073:10101 |
196673 ![]() |
MDC_EVT_LO_LT_LIM | Definition for base term 3::64 MDC_EVT_LO_LT_LIM is: A metric falls short of a given threshold |
urn:iso:std:iso:11073:10101 |
196675 ![]() |
MDC_EVT_LO_VAL_LT_LIM | Definition for base term 3::66 MDC_EVT_LO_VAL_LT_LIM is: A metric falls short of a given threshold. |
urn:iso:std:iso:11073:10101 |
196677 ![]() |
MDC_EVT_LOST | Definition for base term 3::68 MDC_EVT_LOST is: Signal or synchronization, etc., was lost. |
urn:iso:std:iso:11073:10101 |
203789 ![]() |
MDC_EVT_LS_ACCELEROMETER | Definition for base term 3::7180 MDC_EVT_LS_ACCELEROMETER is: 1. Report of item acceleration increase potentially due to leaning or falling 2. Report of item aceleration increase potentially due to leaning or falling. |
urn:iso:std:iso:11073:10101 |
203799 ![]() |
MDC_EVT_LS_BATTERY | Definition for base term 3::7190 MDC_EVT_LS_BATTERY is: 1. Report of item active tag battery status 2. Report of item active tag battery status. |
urn:iso:std:iso:11073:10101 |
203783 ![]() |
MDC_EVT_LS_BOUNDARY | Definition for base term 3::7174 MDC_EVT_LS_BOUNDARY is: 1. Report of constrained location item exceeding defined boundary 2. Report of constrained location item exceeding defined boundary. |
urn:iso:std:iso:11073:10101 |
203785 ![]() |
MDC_EVT_LS_COLOCATION | Definition for base term 3::7176 MDC_EVT_LS_COLOCATION is: 1. Report of item colocation with another item 2. Report of item colocation with another item. |
urn:iso:std:iso:11073:10101 |
203777 ![]() |
MDC_EVT_LS_DEVICE | Definition for base term 3::7168 MDC_EVT_LS_DEVICE is: 1. Report of location of a device as item 2. Report of location of a device as item. |
urn:iso:std:iso:11073:10101 |
203787 ![]() |
MDC_EVT_LS_DWELL | Definition for base term 3::7178 MDC_EVT_LS_DWELL is: 1. Report of expected moving item dwelling in location longer than a defined period 2. Report of expected moving item dwelling in location longer than a defined period. |
urn:iso:std:iso:11073:10101 |
203797 ![]() |
MDC_EVT_LS_ENVIRONMENT | Definition for base term 3::7188 MDC_EVT_LS_ENVIRONMENT is: 1. Report of item environment of temperature, humidity, pressure, gases 2. Report of item environment of temperature, humidity, pressure, gases. |
urn:iso:std:iso:11073:10101 |
203793 ![]() |
MDC_EVT_LS_INTERACTION | Definition for base term 3::7184 MDC_EVT_LS_INTERACTION is: 1. Report of operator interaction with item by button press, cord pull 2. Report of operator interaction with item by button press, cord pull. |
urn:iso:std:iso:11073:10101 |
203795 ![]() |
MDC_EVT_LS_MISSING | Definition for base term 3::7186 MDC_EVT_LS_MISSING is: 1. Report of loss of communication with item 2. Report of loss of communication with item. |
urn:iso:std:iso:11073:10101 |
203781 ![]() |
MDC_EVT_LS_MOVEMENT | Definition for base term 3::7172 MDC_EVT_LS_MOVEMENT is: 1. Report of movement of expected stationary item 2. Report of movement of expected stationary item. |
urn:iso:std:iso:11073:10101 |
203779 ![]() |
MDC_EVT_LS_PERSON | Definition for base term 3::7170 MDC_EVT_LS_PERSON is: 1. Report of location of a person as item 2. Report of location of a person as item. |
urn:iso:std:iso:11073:10101 |
203791 ![]() |
MDC_EVT_LS_TAMPER | Definition for base term 3::7182 MDC_EVT_LS_TAMPER is: 1. Report of item tamper interlock being indicated 2. Report of item tamper interlock being indicated. |
urn:iso:std:iso:11073:10101 |
196679 ![]() |
MDC_EVT_MALF | Definition for base term 3::70 MDC_EVT_MALF is: 1. Malfunction of a device, VMD, or sensor is detected. 2. {NMT} hardware malfunction; unplugging or restarting the {NMT} measurement module may correct the problem. |
urn:iso:std:iso:11073:10101 |
197017 ![]() |
MDC_EVT_MATERIAL_LOW_OR_OUT | Definition for base term 3::408 MDC_EVT_MATERIAL_LOW_OR_OUT is: Unspecified tools or agents (e.g., calibration fluids) are low. |
urn:iso:std:iso:11073:10101 |
196891 ![]() |
MDC_EVT_MED_GAS_SUPPLY_LO | Definition for base term 3::282 MDC_EVT_MED_GAS_SUPPLY_LO is: 1. Medical gas or supply low 2. Medical gas or supply low. |
urn:iso:std:iso:11073:10101 |
196765 ![]() |
MDC_EVT_MIX_ERR | Definition for base term 3::156 MDC_EVT_MIX_ERR is: 1. Mix errror 2. Gas (or other) mixer inoperable. |
urn:iso:std:iso:11073:10101 |
196681 ![]() |
MDC_EVT_MODE | Definition for base term 3::72 MDC_EVT_MODE is: 1. Mode status 2. Mode status (notification) |
urn:iso:std:iso:11073:10101 |
196893 ![]() |
MDC_EVT_MODULE_DISCONN | Definition for base term 3::284 MDC_EVT_MODULE_DISCONN is: 1. Module disconnnected 2. Module disconnected |
urn:iso:std:iso:11073:10101 |
196895 ![]() |
MDC_EVT_MODULE_EXCESS | Definition for base term 3::286 MDC_EVT_MODULE_EXCESS is: 1. Too many [plugin] modules 2. Too many modules. |
urn:iso:std:iso:11073:10101 |
196897 ![]() |
MDC_EVT_MODULE_UNK | Definition for base term 3::288 MDC_EVT_MODULE_UNK is: 1. [Plugin] Module unknown 2. [Plugin] Module unknown. |
urn:iso:std:iso:11073:10101 |
196899 ![]() |
MDC_EVT_MS_SUBSYS_DISCONN | Definition for base term 3::290 MDC_EVT_MS_SUBSYS_DISCONN is: 1. Subsystem disconnected 2. {Measurement module} subsystem disconnected. |
urn:iso:std:iso:11073:10101 |
196901 ![]() |
MDC_EVT_MSG_COMM_ERR | Definition for base term 3::292 MDC_EVT_MSG_COMM_ERR is: 1. Error Event: Communication Message Error 2. Subsystem has received false data packet. |
urn:iso:std:iso:11073:10101 |
197061 ![]() |
MDC_EVT_MSG_CORRUPT | Definition for base term 3::452 MDC_EVT_MSG_CORRUPT is: Subsystem has received false data packet. |
urn:iso:std:iso:11073:10101 |
197025 ![]() |
MDC_EVT_MSG_ERR_PROC | Definition for base term 3::416 MDC_EVT_MSG_ERR_PROC is: 1. Unspecified processing error message 2. Messaging Error. |
urn:iso:std:iso:11073:10101 |
197011 ![]() |
MDC_EVT_MSG_NOM_ERR | Definition for base term 3::402 MDC_EVT_MSG_NOM_ERR is: A message contains wrong code. |
urn:iso:std:iso:11073:10101 |
197079 ![]() |
MDC_EVT_MSG_SEMAN_ERR | Definition for base term 3::470 MDC_EVT_MSG_SEMAN_ERR is: Subsystem has received false data packet. |
urn:iso:std:iso:11073:10101 |
197087 ![]() |
MDC_EVT_MSG_SYNTAX_UNDEF | Definition for base term 3::478 MDC_EVT_MSG_SYNTAX_UNDEF is: 1. Undefined communication message syntax 2. Undefined communication message syntax. |
urn:iso:std:iso:11073:10101 |
196961 ![]() |
MDC_EVT_MSMT_DISCONN | Definition for base term 3::352 MDC_EVT_MSMT_DISCONN is: 1. Error Event: Measurement Unplugged (e.g., in modular patient monitor. Reasoning: In contrast to the disconnect events below, this event indicates that a measurement module was manually (==voluntarily) removed. Dependent on the alarm configuration of a monitor (specifically, with latched alarms), this condition must be announced to the user; and the user must specifically acknowledge the situation.) 2. Error Event: {*} measurement unplugged (e.g., in modular patient monitor. Reasoning: In contrast to the disconnect events below, this event indicates that a measurement module was manually (==voluntarily) removed. Dependent on the alarm configuration of a monitor (specifically, with latched alarms), this condition must be announced to the user; and the user must specifically acknowledge the situation.). [The optional attribute MDC_ATTR_EVT_INTENTIONALITY may be included in the alert message to indicate degree of intentionality by the user.] |
urn:iso:std:iso:11073:10101 |
196963 ![]() |
MDC_EVT_MSMT_ERR | Definition for base term 3::354 MDC_EVT_MSMT_ERR is: 1. Unspecified error in processing of a biosignal 2. Unspecified error in processing of {temperature} biosignal. |
urn:iso:std:iso:11073:10101 |
196965 ![]() |
MDC_EVT_MSMT_FAIL | Definition for base term 3::356 MDC_EVT_MSMT_FAIL is: 1. Error Event: Measurement Failed (e.g., a noninvasive blood pressure) 2. Error Event: {NBP} measurement failed (e.g., a noninvasive blood pressure). |
urn:iso:std:iso:11073:10101 |
196967 ![]() |
MDC_EVT_MSMT_INOP | Definition for base term 3::358 MDC_EVT_MSMT_INOP is: 1. Error Event: Measurement inoperable, Failed (e.g., a noninvasive blood pressure) 2. {SpO2} No measurement |
urn:iso:std:iso:11073:10101 |
196969 ![]() |
MDC_EVT_MSMT_INTERF | Definition for base term 3::360 MDC_EVT_MSMT_INTERF is: 1. Error Event: Measurement intereference (e.g., a noninvasive blood pressure) 2. Interference in measurement |
urn:iso:std:iso:11073:10101 |
197045 ![]() |
MDC_EVT_MSMT_INTERF_ERR | Definition for base term 3::436 MDC_EVT_MSMT_INTERF_ERR is: 1. Interference in measurement 2. Error due to interference in measurement |
urn:iso:std:iso:11073:10101 |
196971 ![]() |
MDC_EVT_MSMT_INTERRUP | Definition for base term 3::362 MDC_EVT_MSMT_INTERRUP is: Error Event: Measurement Interrupted (e.g., a noninvasive blood pressure) (there is a generic interrupted code for processing; however, this code does not have to do with processing. As an example of this code, the user might simply hit a stop button, and this action makes the measurement invalid.) |
urn:iso:std:iso:11073:10101 |
196973 ![]() |
MDC_EVT_MSMT_RANGE_OVER | Definition for base term 3::364 MDC_EVT_MSMT_RANGE_OVER is: 1. Error Event: Measurement Range Exceeded, i.e., the signal is out of the physiological range that is specified in the Metric object. 2. Error Event: Metric (measurement) overrange. 3. Error Event: {NBP} measurement range exceeded, i.e., the signal is out of the physiological range that is specified in the Metric object. |
urn:iso:std:iso:11073:10101 |
196975 ![]() |
MDC_EVT_MSMT_RANGE_UNDER | Definition for base term 3::366 MDC_EVT_MSMT_RANGE_UNDER is: 1. Error Event: Metric (measurement) underrange 2. {NBP} metric (measurement) underrange. |
urn:iso:std:iso:11073:10101 |
197211 ![]() |
MDC_EVT_MULT_REPLY_UNAVAIL | Definition for base term 3::602 MDC_EVT_MULT_REPLY_UNAVAIL is: The multiple reply remote operation function is not available (see Clause 6 in ISO/IEEE 11073-20101:2004) |
urn:iso:std:iso:11073:10101 |
197065 ![]() |
MDC_EVT_NBP_CUFF_DISCONN_OR_LEAK | Definition for base term 3::456 MDC_EVT_NBP_CUFF_DISCONN_OR_LEAK is: 1. Cuff is disconnected or leaking, e.g., in NIBP. 2. NBP cuff is disconnected or leaking. |
urn:iso:std:iso:11073:10101 |
197063 ![]() |
MDC_EVT_NBP_MOTION_DETEC | Definition for base term 3::454 MDC_EVT_NBP_MOTION_DETEC is: 1. Motions are detected, e.g., in NIBP measurement. 2. NBP motion artifact has been detected. |
urn:iso:std:iso:11073:10101 |
196683 ![]() |
MDC_EVT_NOISY | Definition for base term 3::74 MDC_EVT_NOISY is: Signal is noisy. |
urn:iso:std:iso:11073:10101 |
196687 ![]() |
MDC_EVT_NOT_DEFLATED | Definition for base term 3::78 MDC_EVT_NOT_DEFLATED is: 1. Cuff not fully deflated 2. {NBP Cuff} Deflation error |
urn:iso:std:iso:11073:10101 |
196905 ![]() |
MDC_EVT_O2_SUPPLY_LO | Definition for base term 3::296 MDC_EVT_O2_SUPPLY_LO is: 1. Too low O2 delivery (concentration or flow) 2. Too low O2 delivery (concentration or flow). |
urn:iso:std:iso:11073:10101 |
196689 ![]() |
MDC_EVT_OBSTRUC | Definition for base term 3::80 MDC_EVT_OBSTRUC is: Flow is hindered. |
urn:iso:std:iso:11073:10101 |
197015 ![]() |
MDC_EVT_OP_INVALID | Definition for base term 3::406 MDC_EVT_OP_INVALID is: 1. Unspecified handling error 2. Unspecified handling error. |
urn:iso:std:iso:11073:10101 |
196907 ![]() |
MDC_EVT_OPTIC_MODULE_ABSENT | Definition for base term 3::298 MDC_EVT_OPTIC_MODULE_ABSENT is: 1. Optical Module Absent 2. Optical module absent or missing. |
urn:iso:std:iso:11073:10101 |
196909 ![]() |
MDC_EVT_OPTIC_MODULE_DEFECT | Definition for base term 3::300 MDC_EVT_OPTIC_MODULE_DEFECT is: 1. Optical Module Defect 2. Optical module defect. |
urn:iso:std:iso:11073:10101 |
196697 ![]() |
MDC_EVT_OVER | Definition for base term 3::88 MDC_EVT_OVER is: Overflow was detected in a measurement or calculation |
urn:iso:std:iso:11073:10101 |
196699 ![]() |
MDC_EVT_OVERFLOW | Definition for base term 3::90 MDC_EVT_OVERFLOW is: Overflow was detected in a measurement or calculation. |
urn:iso:std:iso:11073:10101 |
196911 ![]() |
MDC_EVT_PAPER_PROB | Definition for base term 3::302 MDC_EVT_PAPER_PROB is: 1. Problem with recording paper 2. [Hardcopy] paper problem. |
urn:iso:std:iso:11073:10101 |
197083 ![]() |
MDC_EVT_PARITY_ERR | Definition for base term 3::474 MDC_EVT_PARITY_ERR is: 1. Communication error: parity error 2. Communication error: parity error. |
urn:iso:std:iso:11073:10101 |
197301 ![]() |
MDC_EVT_PATIENT_CHANGE | Definition for base term 3::692 MDC_EVT_PATIENT_CHANGE is: 1. Advisory: The patient connected to a device has changed 2. Patient Change |
urn:iso:std:iso:11073:10101 |
197303 ![]() |
MDC_EVT_PATIENT_ID_CHANGE | Definition for base term 3::694 MDC_EVT_PATIENT_ID_CHANGE is: 1. Advisory: The ID of the patient connected to the device has changed 2. Patient ID Change |
urn:iso:std:iso:11073:10101 |
197305 ![]() |
MDC_EVT_PATIENT_WEIGHT_CHANGE | Definition for base term 3::696 MDC_EVT_PATIENT_WEIGHT_CHANGE is: 1. Advisory: The patient weight has changed 2. Patient Weight Change |
urn:iso:std:iso:11073:10101 |
197259 ![]() |
MDC_EVT_PCA_DOOR_UNLOCKED | Definition for base term 3::650 MDC_EVT_PCA_DOOR_UNLOCKED is: 1. Advisory: Patient controlled analgesia: door unlocked 2. PCA Door is unlocked |
urn:iso:std:iso:11073:10101 |
197261 ![]() |
MDC_EVT_PCA_HANDSET_DETACHED | Definition for base term 3::652 MDC_EVT_PCA_HANDSET_DETACHED is: 1. Advisory: Patient controlled analgesia: handset detached 2. PCA Handset is detached from unit. |
urn:iso:std:iso:11073:10101 |
197263 ![]() |
MDC_EVT_PCA_MAX_LIMIT | Definition for base term 3::654 MDC_EVT_PCA_MAX_LIMIT is: 1. Advisory: Patient controlled analgesia: maximum limit reached 2. Maximum PCA dose limit reached |
urn:iso:std:iso:11073:10101 |
197265 ![]() |
MDC_EVT_PCA_PAUSED | Definition for base term 3::656 MDC_EVT_PCA_PAUSED is: 1. Advisory: Patient controlled analgesia: paused 2. PCA paused, reason not specified. |
urn:iso:std:iso:11073:10101 |
196913 ![]() |
MDC_EVT_PLUGIN_INCORRECT | Definition for base term 3::304 MDC_EVT_PLUGIN_INCORRECT is: 1. Incorrect plugin [module] 2. Incorrect plugin [module]. |
urn:iso:std:iso:11073:10101 |
196915 ![]() |
MDC_EVT_PLUGIN_POSN_IRREG | Definition for base term 3::306 MDC_EVT_PLUGIN_POSN_IRREG is: Problem in position of a plug-in device |
urn:iso:std:iso:11073:10101 |
196767 ![]() |
MDC_EVT_POSN_IRREG | Definition for base term 3::158 MDC_EVT_POSN_IRREG is: 1. Irregular position of a plug-in device 2. Problem in position of a plug-in device 3. Position irregular. 4. Irregular position of a plug-in device. |
urn:iso:std:iso:11073:10101 |
196769 ![]() |
MDC_EVT_POSN_PROB | Definition for base term 3::160 MDC_EVT_POSN_PROB is: 1. Irregular position of a plug-in device 2. Problem in position of a plug-in device 3. Position irregular. 4. Irregular position of a plug-in device. |
urn:iso:std:iso:11073:10101 |
197169 ![]() |
MDC_EVT_POWER_PROB | Definition for base term 3::560 MDC_EVT_POWER_PROB is: Problem in power supply |
urn:iso:std:iso:11073:10101 |
197067 ![]() |
MDC_EVT_POWER_SUPPLY_PROB | Definition for base term 3::458 MDC_EVT_POWER_SUPPLY_PROB is: 1. Problem in power supply 2. {*} power supply problem. |
urn:iso:std:iso:11073:10101 |
196987 ![]() |
MDC_EVT_PRESS_CUFF_OVER | Definition for base term 3::378 MDC_EVT_PRESS_CUFF_OVER is: 1. Cuff over pressure 2. {NBP} cuff overpressure. |
urn:iso:std:iso:11073:10101 |
197167 ![]() |
MDC_EVT_PRESS_FLUID_LINE_EXCESS | Definition for base term 3::558 MDC_EVT_PRESS_FLUID_LINE_EXCESS is: 1. High pressure in fluid line 2. Too much pressure in line. |
urn:iso:std:iso:11073:10101 |
196977 ![]() |
MDC_EVT_PRESS_HI_GT_LIM | Definition for base term 3::368 MDC_EVT_PRESS_HI_GT_LIM is: High pressure |
urn:iso:std:iso:11073:10101 |
196979 ![]() |
MDC_EVT_PRESS_HI_VAL_GT_LIM | Definition for base term 3::370 MDC_EVT_PRESS_HI_VAL_GT_LIM is: High pressure |
urn:iso:std:iso:11073:10101 |
196981 ![]() |
MDC_EVT_PRESS_SUBATMOS | Definition for base term 3::372 MDC_EVT_PRESS_SUBATMOS is: 1. Pressure subatmospheric [Vent] 2. [Vent] Pressure subatmospheric. |
urn:iso:std:iso:11073:10101 |
196983 ![]() |
MDC_EVT_PRESS_SUPPLY_HI | Definition for base term 3::374 MDC_EVT_PRESS_SUPPLY_HI is: 1. High supply pressure 2. Supply pressure high. |
urn:iso:std:iso:11073:10101 |
196985 ![]() |
MDC_EVT_PRESS_SUPPLY_LO | Definition for base term 3::376 MDC_EVT_PRESS_SUPPLY_LO is: 1. Low supply pressure 2. Supply pressure low. |
urn:iso:std:iso:11073:10101 |
196701 ![]() |
MDC_EVT_PROB | Definition for base term 3::92 MDC_EVT_PROB is: 1. Unspecified device error 2. Problem (NOS). |
urn:iso:std:iso:11073:10101 |
197029 ![]() |
MDC_EVT_PROC | Definition for base term 3::420 MDC_EVT_PROC is: 1. Unspecified processing error 2. Unspecified processing event. |
urn:iso:std:iso:11073:10101 |
196771 ![]() |
MDC_EVT_PROC_ERR | Definition for base term 3::162 MDC_EVT_PROC_ERR is: 1. Unspecified processing error 2. Unspecified processing error. |
urn:iso:std:iso:11073:10101 |
199917 ![]() |
MDC_EVT_PULS_NON_PULSATILE | Definition for base term 3::3308 MDC_EVT_PULS_NON_PULSATILE is: 1. NIBP non pulsatile 2. Pulse absent or non-pulsatile |
urn:iso:std:iso:11073:10101 |
197353 ![]() |
MDC_EVT_PUMP_CHAMBER_BLOCKED | Definition for base term 3::744 MDC_EVT_PUMP_CHAMBER_BLOCKED is: Pump chamber blocked. |
urn:iso:std:iso:11073:10101 |
197207 ![]() |
MDC_EVT_PUMP_FLOW_FREE | Definition for base term 3::598 MDC_EVT_PUMP_FLOW_FREE is: 1. Pump in free flow 2. Pump in free flow. |
urn:iso:std:iso:11073:10101 |
197183 ![]() |
MDC_EVT_PUMP_SYRINGE_DELIV_TIMEOUT | Definition for base term 3::574 MDC_EVT_PUMP_SYRINGE_DELIV_TIMEOUT is: Configured time to deliver whole syringe/bottle is over. |
urn:iso:std:iso:11073:10101 |
197195 ![]() |
MDC_EVT_PUMP_VOL_TBI_COMP | Definition for base term 3::586 MDC_EVT_PUMP_VOL_TBI_COMP is: 1. Total volume infused (pump) 2. Total programmed volume infused (pump). 3. Infusion complete, where the programmed volume has been infused (pump). |
urn:iso:std:iso:11073:10101 |
197343 ![]() |
MDC_EVT_PWR_LOSS | Definition for base term 3::734 MDC_EVT_PWR_LOSS is: 1. Loss of power supply 2. Power Loss |
urn:iso:std:iso:11073:10101 |
197021 ![]() |
MDC_EVT_QOS | Definition for base term 3::412 MDC_EVT_QOS is: 1. Communication error: quality of service (QOS) 2. Unspecified Quality of Service event. |
urn:iso:std:iso:11073:10101 |
196773 ![]() |
MDC_EVT_RANGE_ERR | Definition for base term 3::164 MDC_EVT_RANGE_ERR is: 1. Signal amplitude is incorrect for processing 2. Signal out of range |
urn:iso:std:iso:11073:10101 |
196775 ![]() |
MDC_EVT_RANGE_OVER | Definition for base term 3::166 MDC_EVT_RANGE_OVER is: 1. Signal amplitude is too high for processing. 2. {Impedance respiration rate} Out of range (high) |
urn:iso:std:iso:11073:10101 |
196777 ![]() |
MDC_EVT_RANGE_UNDER | Definition for base term 3::168 MDC_EVT_RANGE_UNDER is: 1. Signal amplitude is too low for processing, e.g., waveform detection. 2. {ST} Out of range (low) |
urn:iso:std:iso:11073:10101 |
196739 ![]() |
MDC_EVT_RECOV_ERR | Definition for base term 3::130 MDC_EVT_RECOV_ERR is: 1. Recoverable state machine error in communication 2. Recoverable state machine error in communication. |
urn:iso:std:iso:11073:10101 |
199887 ![]() |
MDC_EVT_RESP_BREATHING_SPONT_ASSIST_PSW | Definition for base term 3::3278 MDC_EVT_RESP_BREATHING_SPONT_ASSIST_PSW is: 1. Assisted spontaneous breathing longer than a predefined time span (PSW) 2. Assisted spontaneous breathing longer then a predefined time span (PSW) |
urn:iso:std:iso:11073:10101 |
199865 ![]() |
MDC_EVT_RESP_VOL_BREATHING_IRREG | Definition for base term 3::3256 MDC_EVT_RESP_VOL_BREATHING_IRREG is: Breathing volume not constant |
urn:iso:std:iso:11073:10101 |
197123 ![]() |
MDC_EVT_RESPIRATOR_TEMP_HI | Definition for base term 3::514 MDC_EVT_RESPIRATOR_TEMP_HI is: Respirator device temperature is too high. |
urn:iso:std:iso:11073:10101 |
196705 ![]() |
MDC_EVT_REVERSED | Definition for base term 3::96 MDC_EVT_REVERSED is: Flow is reversed |
urn:iso:std:iso:11073:10101 |
196917 ![]() |
MDC_EVT_SENSOR_DISCONN | Definition for base term 3::308 MDC_EVT_SENSOR_DISCONN is: 1. Sensor disconnection or fault 2. {SpO2} sensor disconnection or fault. |
urn:iso:std:iso:11073:10101 |
196919 ![]() |
MDC_EVT_SENSOR_MALF | Definition for base term 3::310 MDC_EVT_SENSOR_MALF is: 1. Sensor malfunction 2. {SpO2} sensor malfunction. 3. {SpO2} sensor malfunction, a current state or condition of faulty or improper functioning. |
urn:iso:std:iso:11073:10101 |
196921 ![]() |
MDC_EVT_SENSOR_PROB | Definition for base term 3::312 MDC_EVT_SENSOR_PROB is: 1. Flow sensor problem 2. {SpO2} sensor problem. |
urn:iso:std:iso:11073:10101 |
196779 ![]() |
MDC_EVT_SHAPE_ERR | Definition for base term 3::170 MDC_EVT_SHAPE_ERR is: [Pattern] Shape error. |
urn:iso:std:iso:11073:10101 |
196709 ![]() |
MDC_EVT_SHORT | Definition for base term 3::100 MDC_EVT_SHORT is: 1. Error Event: Sensor electrical lead (e.g., ECG) is shorted (NOS) 2. Short (electrical) [NOS]. |
urn:iso:std:iso:11073:10101 |
196923 ![]() |
MDC_EVT_SIDESTRM_MALF | Definition for base term 3::314 MDC_EVT_SIDESTRM_MALF is: 1. [CO2] Sidestream malfunction 2. {Airway CO2} sidestream malfunction. |
urn:iso:std:iso:11073:10101 |
196925 ![]() |
MDC_EVT_SIDESTRM_OFF | Definition for base term 3::316 MDC_EVT_SIDESTRM_OFF is: 1. [CO2] Sidestream off 2. {Airway CO2} sidestream off. |
urn:iso:std:iso:11073:10101 |
196927 ![]() |
MDC_EVT_SIDESTRM_ON | Definition for base term 3::318 MDC_EVT_SIDESTRM_ON is: 1. [CO2] Sidestream on 2. {Airway CO2} sidestream on. |
urn:iso:std:iso:11073:10101 |
197053 ![]() |
MDC_EVT_SIG_ABSENT | Definition for base term 3::444 MDC_EVT_SIG_ABSENT is: 1. Typically, a zero voltage signal 2. Typically, a zero voltage signal. |
urn:iso:std:iso:11073:10101 |
197103 ![]() |
MDC_EVT_SIG_ABSENT_OSCIL | Definition for base term 3::494 MDC_EVT_SIG_ABSENT_OSCIL is: 1. Oscillation in signal is absent 2. No oscillation. |
urn:iso:std:iso:11073:10101 |
197105 ![]() |
MDC_EVT_SIG_AMPL_INVALID | Definition for base term 3::496 MDC_EVT_SIG_AMPL_INVALID is: 1. Signal amplitude is not as expected 2. Invalid signal - shape/amplitude of signal unnormal. |
urn:iso:std:iso:11073:10101 |
197109 ![]() |
MDC_EVT_SIG_ARTIFACT | Definition for base term 3::500 MDC_EVT_SIG_ARTIFACT is: 1. Signal artifact detected 2. {ECG} Artifact |
urn:iso:std:iso:11073:10101 |
196781 ![]() |
MDC_EVT_SIG_ERRATIC | Definition for base term 3::172 MDC_EVT_SIG_ERRATIC is: Error Event: Signal erratic |
urn:iso:std:iso:11073:10101 |
197013 ![]() |
MDC_EVT_SIG_GAIN_LO | Definition for base term 3::404 MDC_EVT_SIG_GAIN_LO is: 1. Signal gain low: probably erroneous data extraction 2. Signal gain low: probably erroneous data extraction. |
urn:iso:std:iso:11073:10101 |
196989 ![]() |
MDC_EVT_SIG_LO | Definition for base term 3::380 MDC_EVT_SIG_LO is: 1. Signal is low 2. {SpO2} signal low. |
urn:iso:std:iso:11073:10101 |
197049 ![]() |
MDC_EVT_SIG_NOISY | Definition for base term 3::440 MDC_EVT_SIG_NOISY is: Noisy signal: result may be erroneous. |
urn:iso:std:iso:11073:10101 |
197055 ![]() |
MDC_EVT_SIG_OUT_OF_RANGE | Definition for base term 3::446 MDC_EVT_SIG_OUT_OF_RANGE is: 1. Signal is out of range. 2. {SvO2} signal is out of range. |
urn:iso:std:iso:11073:10101 |
197057 ![]() |
MDC_EVT_SIG_PROC_ERR | Definition for base term 3::448 MDC_EVT_SIG_PROC_ERR is: 1. Unspecified signal processing error 2. Unspecified signal processing error. |
urn:iso:std:iso:11073:10101 |
196997 ![]() |
MDC_EVT_SIG_RANGE_OVER | Definition for base term 3::388 MDC_EVT_SIG_RANGE_OVER is: 1. Signal is overrange 2. Signal out of physical range. |
urn:iso:std:iso:11073:10101 |
196999 ![]() |
MDC_EVT_SIG_RANGE_UNDER | Definition for base term 3::390 MDC_EVT_SIG_RANGE_UNDER is: 1. Signal is underrange 2. Signal out of range. |
urn:iso:std:iso:11073:10101 |
197107 ![]() |
MDC_EVT_SIG_RATE_EQU | Definition for base term 3::498 MDC_EVT_SIG_RATE_EQU is: 1. Pulserate coincidence 2. Pulserate coincidence. |
urn:iso:std:iso:11073:10101 |
197001 ![]() |
MDC_EVT_SIG_STRENGTH_WEAK | Definition for base term 3::392 MDC_EVT_SIG_STRENGTH_WEAK is: 1. Signal is weak 2. {SvO2} signal strength is weak. |
urn:iso:std:iso:11073:10101 |
196993 ![]() |
MDC_EVT_SIG_UNANALYZEABLE | Definition for base term 3::384 MDC_EVT_SIG_UNANALYZEABLE is: 1. Error Event: Signal Cannot Be Analyzed (for any secondary derived measurement when the input signal is bad) 2. Error Event: Signal Cannot Be Analyzed (for any secondary derived measurement when the input signal is bad). [For example, {ECG QT} measurement is unanalyzable.] |
urn:iso:std:iso:11073:10101 |
196929 ![]() |
MDC_EVT_SITE_TIMER_PROB | Definition for base term 3::320 MDC_EVT_SITE_TIMER_PROB is: 1. Site timer problem 2. Site Timer Problem. |
urn:iso:std:iso:11073:10101 |
196783 ![]() |
MDC_EVT_SRC_ABSENT | Definition for base term 3::174 MDC_EVT_SRC_ABSENT is: 1. Error Event: Signal source absent 2. Source absent or missing. |
urn:iso:std:iso:11073:10101 |
258049 ![]() |
MDC_EVT_STANDBY_WARN | Definition for base term 3::61440 MDC_EVT_STANDBY_WARN is: Warning that device will go to standy |
urn:iso:std:iso:11073:10101 |
202807 ![]() |
MDC_EVT_STAT_ACTIVE | Definition for base term 3::6198 MDC_EVT_STAT_ACTIVE is: 1. Active state of, e.g., device 2. Active state of, e.g., device. |
urn:iso:std:iso:11073:10101 |
202825 ![]() |
MDC_EVT_STAT_AL | Definition for base term 3::6216 MDC_EVT_STAT_AL is: 1. Alarm state of, e.g., device or signal 2. Alarm state of, e.g., device or signal. |
urn:iso:std:iso:11073:10101 |
202753 ![]() |
MDC_EVT_STAT_AL_OFF | Definition for base term 3::6144 MDC_EVT_STAT_AL_OFF is: 1. Indication: Alarm Intentionally Off (disabled) 2. Indication: Alarm Intentionally Off (disabled). [This term is deprecated; use MDC_EVT_STAT_AIS_ALARM_OFF instead.] |
urn:iso:std:iso:11073:10101 |
202755 ![]() |
MDC_EVT_STAT_AL_ON | Definition for base term 3::6146 MDC_EVT_STAT_AL_ON is: 1. Indication: Alarm Intentionally On (enabled) 2. Indication: Alarm Intentionally On (enabled). [This term is deprecated; use MDC_EVT_STAT_AIS_ENABLED instead.] |
urn:iso:std:iso:11073:10101 |
202827 ![]() |
MDC_EVT_STAT_AL_PAUSED | Definition for base term 3::6218 MDC_EVT_STAT_AL_PAUSED is: 1. Indication: Alarm paused 2. Alarm is paused (visual and audio indications are off). [This term is deprecated; use MDC_EVT_STAT_AIS_ALARM_PAUSED instead.] |
urn:iso:std:iso:11073:10101 |
202823 ![]() |
MDC_EVT_STAT_AL_SILENCE | Definition for base term 3::6214 MDC_EVT_STAT_AL_SILENCE is: 1. Alarm is silenced (speaker off). 2. Alarm is silenced (speaker off). [This term is deprecated; use MDC_EVT_STAT_AIS_AUDIO_OFF instead.] |
urn:iso:std:iso:11073:10101 |
202839 ![]() |
MDC_EVT_STAT_AL_TACHAPNEA_DISABL | Definition for base term 3::6230 MDC_EVT_STAT_AL_TACHAPNEA_DISABL is: 1. Tachyapnea alarm is disabled. 2. Tachyapnea alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_TACHYPNEA_AIS_ALARM_OFF instead.] |
urn:iso:std:iso:11073:10101 |
202883 ![]() |
MDC_EVT_STAT_APNEA_AL_DISABL | Definition for base term 3::6274 MDC_EVT_STAT_APNEA_AL_DISABL is: 1. Apnea alarm is disabled. 2. Apnea alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_APNEA_RELATED_AIS_ALARM_OFF instead.] |
urn:iso:std:iso:11073:10101 |
202757 ![]() |
MDC_EVT_STAT_BACKUP_MODE | Definition for base term 3::6148 MDC_EVT_STAT_BACKUP_MODE is: 1. Indication: Device in Backup mode, No Measurement Possible 2. Status: Backup mode. |
urn:iso:std:iso:11073:10101 |
202759 ![]() |
MDC_EVT_STAT_BATT_CHARGING | Definition for base term 3::6150 MDC_EVT_STAT_BATT_CHARGING is: Battery is now being recharged. |
urn:iso:std:iso:11073:10101 |
202765 ![]() |
MDC_EVT_STAT_CALIB_INVIVO_RUNNING | Definition for base term 3::6156 MDC_EVT_STAT_CALIB_INVIVO_RUNNING is: 1. Indication: Calibration of invivo probe in Progress, No Measurement Possible 2. Status: Invivo Calibration running. |
urn:iso:std:iso:11073:10101 |
202767 ![]() |
MDC_EVT_STAT_CALIB_LIGHT_RUNNING | Definition for base term 3::6158 MDC_EVT_STAT_CALIB_LIGHT_RUNNING is: 1. Indication: Calibration of light source in Progress, No Measurement Possible 2. Status: Light Calibration running. |
urn:iso:std:iso:11073:10101 |
202761 ![]() |
MDC_EVT_STAT_CALIB_MODE | Definition for base term 3::6152 MDC_EVT_STAT_CALIB_MODE is: 1. Indication: Device in Calibration mode, No Measurement Possible 2. Calibration Mode or status [NOS]. |
urn:iso:std:iso:11073:10101 |
202769 ![]() |
MDC_EVT_STAT_CALIB_PREINS_RUNNING | Definition for base term 3::6160 MDC_EVT_STAT_CALIB_PREINS_RUNNING is: 1. Indication: Calibration of an optical (or other) sensor prior to insertion of a sensor/catheter 2. Status: Pre-insertion Calibration running. |
urn:iso:std:iso:11073:10101 |
202763 ![]() |
MDC_EVT_STAT_CALIB_RUNNING | Definition for base term 3::6154 MDC_EVT_STAT_CALIB_RUNNING is: 1. Indication: Calibration in Progress, No Measurement Possible 2. {SpO2} Sensor calibrating |
urn:iso:std:iso:11073:10101 |
202821 ![]() |
MDC_EVT_STAT_CHARGING | Definition for base term 3::6212 MDC_EVT_STAT_CHARGING is: 1. Charging state of, e.g., battery 2. Charging state of, e.g., battery. |
urn:iso:std:iso:11073:10101 |
202879 ![]() |
MDC_EVT_STAT_CO2_AL_DISABL | Definition for base term 3::6270 MDC_EVT_STAT_CO2_AL_DISABL is: 1. Carbon dioxide alarm is disabled. 2. Carbon dioxide alarm is disabled. [This term is deprecated; use MDC_EVT_STAT_CO2_AIS_ALARM_OFF instead.] |
urn:iso:std:iso:11073:10101 |
202901 ![]() |
MDC_EVT_STAT_CO2_UNCALIB | Definition for base term 3::6292 MDC_EVT_STAT_CO2_UNCALIB is: 1. Carbon dioxide is not calibrated. 2. The airway CO2 monitor is not calibrated. |
urn:iso:std:iso:11073:10101 |
202877 ![]() |
MDC_EVT_STAT_CO2_WARMING | Definition for base term 3::6268 MDC_EVT_STAT_CO2_WARMING is: 1. Carbon dioxide monitor in warm-up mode 2. The airway CO2 monitor in warm-up mode. |
urn:iso:std:iso:11073:10101 |
202771 ![]() |
MDC_EVT_STAT_CONFIG | Definition for base term 3::6162 MDC_EVT_STAT_CONFIG is: 1. Indication: Configuration in Progress, No Measurement Possible 2. Status: Configuring {*}. |
urn:iso:std:iso:11073:10101 |
202861 ![]() |
MDC_EVT_STAT_CONN | Definition for base term 3::6252 MDC_EVT_STAT_CONN is: 1. Connected state of device, sensor, etc. 2. Connected state of {*} device, sensor, etc. |
urn:iso:std:iso:11073:10101 |
202857 ![]() |
MDC_EVT_STAT_DEPLET | Definition for base term 3::6248 MDC_EVT_STAT_DEPLET is: A sensor, absorber, etc., is depleted. |
urn:iso:std:iso:11073:10101 |
202887 ![]() |
MDC_EVT_STAT_DEV | Definition for base term 3::6278 MDC_EVT_STAT_DEV is: 1. Report of functional status of device 2. Device (functional) status. |
urn:iso:std:iso:11073:10101 |
202885 ![]() |
MDC_EVT_STAT_DEV_BATT_OPERATED | Definition for base term 3::6276 MDC_EVT_STAT_DEV_BATT_OPERATED is: Device is battery operated. |
urn:iso:std:iso:11073:10101 |
202893 ![]() |
MDC_EVT_STAT_DEV_MAINS_OPERATED | Definition for base term 3::6284 MDC_EVT_STAT_DEV_MAINS_OPERATED is: Device is mains-operated. |
urn:iso:std:iso:11073:10101 |
202891 ![]() |
MDC_EVT_STAT_DEV_MODE_ADULT | Definition for base term 3::6282 MDC_EVT_STAT_DEV_MODE_ADULT is: Device is in adult mode. |
urn:iso:std:iso:11073:10101 |
202895 ![]() |
MDC_EVT_STAT_DEV_MODE_COMPUT_CNTRLD | Definition for base term 3::6286 MDC_EVT_STAT_DEV_MODE_COMPUT_CNTRLD is: Device, e.g., pump, is in computer-controlled mode. |
urn:iso:std:iso:11073:10101 |
202889 ![]() |
MDC_EVT_STAT_DEV_MODE_PEDIATRIC | Definition for base term 3::6280 MDC_EVT_STAT_DEV_MODE_PEDIATRIC is: Device is in pediatric mode. |
urn:iso:std:iso:11073:10101 |
202865 ![]() |
MDC_EVT_STAT_DISCONN | Definition for base term 3::6256 MDC_EVT_STAT_DISCONN is: Disconnection of a sensor, device, etc. |
urn:iso:std:iso:11073:10101 |
196711 ![]() |
MDC_EVT_STAT_DISP_STOP | Definition for base term 3::102 MDC_EVT_STAT_DISP_STOP is: The display is stopped. |
urn:iso:std:iso:11073:10101 |
202853 ![]() |
MDC_EVT_STAT_DOOR_CLOS | Definition for base term 3::6244 MDC_EVT_STAT_DOOR_CLOS is: 1. Door in the (sleep measurement) room is closed. 2. Door in the {sleep measurement} room is closed. |
urn:iso:std:iso:11073:10101 |
202829 ![]() |
MDC_EVT_STAT_DOOR_OPEN | Definition for base term 3::6220 MDC_EVT_STAT_DOOR_OPEN is: 1. Door in the (sleep measurement) room is opened. 2. Door in the {sleep measurement} room is opened. |
urn:iso:std:iso:11073:10101 |
202791 ![]() |
MDC_EVT_STAT_ECG_AL_ALL_OFF | Definition for base term 3::6182 MDC_EVT_STAT_ECG_AL_ALL_OFF is: Status: All ECG alarms are off (still need these in France to meet French homologation, despite MDD). |
urn:iso:std:iso:11073:10101 |
202793 ![]() |
MDC_EVT_STAT_ECG_AL_SOME_OFF | Definition for base term 3::6184 MDC_EVT_STAT_ECG_AL_SOME_OFF is: Status: Some ECG alarms are off (still need these in France to meet French homologation, despite MDD). |
urn:iso:std:iso:11073:10101 |
199707 ![]() |
MDC_EVT_STAT_ECG_PACING | Definition for base term 3::3098 MDC_EVT_STAT_ECG_PACING is: Pacer operational and controlling heart rhythm |
urn:iso:std:iso:11073:10101 |
202833 ![]() |
MDC_EVT_STAT_LEARN | Definition for base term 3::6224 MDC_EVT_STAT_LEARN is: 1. Indication: Learning - analyzing waveform 2. The {ECG} signal processing algorithm is in the «learning» state. |
urn:iso:std:iso:11073:10101 |
202869 ![]() |
MDC_EVT_STAT_LIGHTS_IN_ROOM_ON | Definition for base term 3::6260 MDC_EVT_STAT_LIGHTS_IN_ROOM_ON is: 1. Lights in the (sleep measurement) room are switched on. 2. Lights in the {sleep measurement} room are switched on. |
urn:iso:std:iso:11073:10101 |
202797 ![]() |
MDC_EVT_STAT_MODE_SIGH_ACTIVE | Definition for base term 3::6188 MDC_EVT_STAT_MODE_SIGH_ACTIVE is: Sigh mode is active. |
urn:iso:std:iso:11073:10101 |
202841 ![]() |
MDC_EVT_STAT_MODE_TEST | Definition for base term 3::6232 MDC_EVT_STAT_MODE_TEST is: Device or VMD is in test mode. |
urn:iso:std:iso:11073:10101 |
202859 ![]() |
MDC_EVT_STAT_NBP_DEFL_AND_MEAS_BP | Definition for base term 3::6250 MDC_EVT_STAT_NBP_DEFL_AND_MEAS_BP is: 1. NIBP is deflating cuff and measuring blood pressure. 2. Noninvasive blood pressure device is deflating cuff and measuring blood pressure. |
urn:iso:std:iso:11073:10101 |
202831 ![]() |
MDC_EVT_STAT_NBP_INFL_TO_MAX_CUFF_PRESS | Definition for base term 3::6222 MDC_EVT_STAT_NBP_INFL_TO_MAX_CUFF_PRESS is: 1. NIBP is inflating cuff to maximum cuff pressure. 2. Noninvasive blood pressure device is inflating cuff to maximum cuff pressure. |
urn:iso:std:iso:11073:10101 |
202835 ![]() |
MDC_EVT_STAT_OFF | Definition for base term 3::6226 MDC_EVT_STAT_OFF is: 1. Device or VMD is in off condition. 2. Off (e.g. device or VMD is in an off condition) |
urn:iso:std:iso:11073:10101 |
202875 ![]() |
MDC_EVT_STAT_ON | Definition for base term 3::6266 MDC_EVT_STAT_ON is: 1. Device or VMD is in on condition 2. On (e.g. device or VMD is in an on condition) |
urn:iso:std:iso:11073:10101 |
202781 ![]() |
MDC_EVT_STAT_OPT_MOD_SENSOR_CONN | Definition for base term 3::6172 MDC_EVT_STAT_OPT_MOD_SENSOR_CONN is: 1. Indication: Optical sensor connected 2. Status: {SvO2} optical module connected. |
See the full registry of value sets defined as part of FHIR.
Explanation of the columns that may appear on this page:
| Lvl | A few code lists that FHIR defines are hierarchical - each code is assigned a level. For value sets, levels are mostly used to organize codes for user convenience, but may follow code system hierarchy - see Code System for further information |
| Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract') |
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |